Search NASA⌕ Search

SEARCH · Search NASA

Results for “data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a Low Cost Data Acquisition System for the Solid Rocket Booster Program

The Space Transportation System's (STS) Solid Rocket Boosters (SRBs) experience a severe environment during their brief flight. During the last few years several SRB's have sustained noticeable structural damage. The environmental characteristics (vibration, structure, and thermal) encountered by the SRB's during ascent, descent and water impact are in most cases unknown. A developmental flight instrumentation (DFI) system collected data from the SRB's first four flights in the early 1980's, and after the first three flights during the shuttle return-to-flight phase after the Challenger accident. However, the DFI data collected are of low fidelity and do not correlate well with the observed structural damage. The DFI system was evaluated for reuse, but the cost to fly it was prohibitive. The STS is presently scheduled to fly until 2030. To support the STS schedule the avionics on SRB's will be upgraded. The environments on the different sections of the SRB will need to be defined to properly qualify the avionics for multiple flights. The DFI data previously gathered does not provide enough information to properly qualify the avionics. Marshall Space Flight Centers (MSFC) SRB Project Office requested the Science and Engineering Directorate to develop a self contained data acquisition system that could collect data from any area of the booster. This paper summarizes the effort to develop, test, qualify and fly an Enhanced Data Acquisition System (EDAS) using state-of-the-art commercial off the shelf (COTS) equipment. The first flight of this system occurred on shuttle mission STS-91 in June 1998.

Crawford, Kevin↗

The Lick Observatory CCD data acquisition system

An evolving system for CCD data acquisition is described. The electronics are subdivided into those attached to the dewar, a 'smart' controller near the dewar, and a computer connected by serial link to the smart controller. Software for the smart controller is in assembler code, while the data acquisition and on-line analysis software is written in 'C' and uses the UNIX operating system.

Robinson, L. B.↗

Space Shuttle tracking and data acquisition system

NASA's plans for the Space Shuttle tracking and data acquisition system are described. The limitations of the techniques now used for tracking and data acquisition support of earth orbiting spacecraft are discussed. NASA's solution to these limitations, the Tracking and Data Relay Satellite System, is described. The system's geometrical coverage and technical characteristics are explained. Operation of the system for Space Shuttle support is described in overview terms.

Robinson, L. M.↗

Low-power triggered data acquisition system and method

A low-power triggered data acquisition system and method utilizes low-powered circuitry, comparators, and digital logic incorporated into a miniaturized device interfaced with self-generating transducer sensor inputs to detect, identify and assess impact and damage to surfaces and structures wherein, upon the occurrence of a triggering event that produces a signal greater than a set threshold changes the comparator output and causes the system to acquire and store digital data representative of the incoming waveform on at least one triggered channel. The sensors may be disposed in an array to provide triangulation and location of the impact.

Champaigne, Kevin↗

Wind tunnel real-time data acquisition system

The hardware configuration is described for the data acquisition system (DAS) which consists of an analog front end that can process up to 260 channels of data, a multichannel analog-to-digital subsystem that can process up to 50,000 samples of data per second, and a digital computer with standard and nonstandard devices, including graphics capability. Also described are the software configuration of the DAS and complex hardware/software interfaces providing, for example, automatic amplifier gain and offset adjustment for each data channel. Specific DAS applications are summarized, including the real time processing of dynamic deflection data, unsteady pressure measurements, and flutter and buffet data.

Cole, P.↗

Olympus propagation studies in the US: Receiver development and the data acquisition system

Virginia Tech has developed two types of receivers to monitor the Olympus beacons, as well as a custom data acquisition system to store and display propagation data. Each of the receiver designs uses new hybrid analog/digital techniques. The data acquisition system uses a stand alone processor to collect and format the data for display and subsequent processing. The launch of the Olympus satellite with its coherent beacons offers new opportunities to study propagation effects at 12.5, 20, and 30 GHz. At Virginia Tech, the satellite is at 14 degrees in elevation, which allows us to measure low elevation angle effects. However, to make these measurements, a very accurate and stable measurement system is required. Virginia Tech has constructed a complex receiving system which monitors the Olympus beacons and all parameters associated with propagation research. In the current configuration, researchers have developed a receiver which frequency locks to the less fade susceptible 12.5 GHz beacon. Since all beacons on the satellite are driven from a single master oscillator, drift in the 12.5 GHz beacon implies corresponding drifts in the 20, and 30 GHz beacons. The receivers for the 20 and 30 GHz systems derive their frequency locking information from the 12.5 GHz system. This widens the dynamic range of the receivers and allows the receivers to maintain lock in severe fade conditions. In addition to monitoring the beacons, the sky noise is monitored with radiometers at each frequency. The radiometer output is used to set the clear air level for each beacon measurement. Researchers also measure the rain rate with several tipping bucket rain gauges placed along the propagation path.

Mckeeman, John C.↗

A Unified User-Friendly Instrument Control and Data Acquisition System for the ORNL SANS Instrument Suite

In an effort to upgrade and provide a unified and improved instrument control and data acquisition system for the Oak Ridge National Laboratory (ORNL) small-angle neutron scattering (SANS) instrument suite—biological small-angle neutron scattering instrument (Bio-SANS), the extended q-range small-angle neutron scattering diffractometer (EQ-SANS), the general-purpose small-angle neutron scattering diffractometer (GP-SANS)—beamline scientists and developers teamed up and worked closely together to design and develop a new system. We began with an in-depth analysis of user needs and requirements, covering all perspectives of control and data acquisition based on previous usage data and user feedback. Our design and implementation were guided by the principles from the latest user experience and design research and based on effective practices from our previous projects. In this article, we share details of our design process as well as prominent features of the new instrument control and data acquisition system. The new system provides a sophisticated Q-Range Planner to help scientists and users plan and execute instrument configurations easily and efficiently. The system also provides different user operation interfaces, such as wizard-type tool Panel Scan, a Scripting Tool based on Python Language, and Table Scan, all of which are tailored to different user needs. The new system further captures all the metadata to enable post-experiment data reduction and possibly automatic reduction and provides users with enhanced live displays and additional feedback at the run time. We hope our results will serve as a good example for developing a user-friendly instrument control and data acquisition system at large user facilities.

47 OTHER INSTRUMENTATION↗

Systolic time interval data acquisition system. Specialized cardiovascular studies

The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

Baker, J. T.↗

Upgrading the 14x22 Data Acquisition System (DAS)

The 14-by 22-Foot Subsonic Tunnel recently completed development and installation of a new Data Acquisition System for use in the tunnel and in the Rotor Test Cell (RTC). Planning and development of this new system has been ongoing for several years, and installation was performed over this past year. This effort also required an upgrade of the facility infrastructure to support the upgraded power and cooling requirements. This presentation summarizes the new data acquisition system, improved capabilities, challenges of installation, and proposed future enhancements to the system.

wind tunnel↗

A Description of the Development, Capabilities, and Operational Status of the Test SLATE Data Acquisition System at the National Transonic Facility

The paper will present a brief background of the previous data acquisition system at the National Transonic Facility (NTF) and the reasoning and goals behind the upgrade to the current Test SLATE (Test Software Laboratory and Automated Testing Environments) data acquisition system. The components, performance characteristics, and layout of the Test SLATE system within the NTF control room will be discussed. The development, testing, and integration of Test SLATE within NTF operations will be detailed. The operational capabilities of the system will be outlined including: test setup, instrumentation calibration, automatic test sequencer setup, data recording, communication between data and facility control systems, real time display monitoring, and data reduction. The current operational status of the Test SLATE system and its performance during recent NTF testing will be highlighted including high-speed, frame-by-frame data acquisition with conditional sampling post-processing applied. The paper concludes with current development work on the system including the capability for real-time conditional sampling during data acquisition and further efficiency enhancements to the wind tunnel testing process.

Cramer, Christopher J.↗

100 Gb/s High Throughput Serial Protocol (HTSP) for data acquisition systems with interleaved streaming

Demands on Field-Programmable Gate Array (FPGA) data transport have been increasing over the years as frame sizes and refresh rates increase. As the bandwidths requirements increase the ability to implement data transport protocol layers using "soft" programmable logic becomes harder and start to require harden IP blocks implementation. To reduce the number of physical links and interconnects, it is common for data acquisition systems to require interleaving of streams on the same link (e.g. streaming data and streaming register access). Further, this paper presents a way to leverage existing FPGA harden IP blocks to achieve a robust, low latency 100 Gb/s point-to-point link with minimal programmable logic overhead geared towards the needs of data acquisition systems with interleaved streaming requirements.

47 OTHER INSTRUMENTATION↗

A distributed data acquisition system for aeronautics test facilities

The NASA Lewis Research Center is in the process of installing a new data acquisition and display system. This new system will provide small and medium sized aeronautics test facilities with a state-of-the-art real-time data acquisition and display system. The new data system will provide for the acquisition of signals from a variety of instrumentation sources. They include analog measurements of temperatures, pressures, and other steady state voltage inputs; frequency inputs to measure speed and flow; discrete I/O for significant events, and modular instrument systems such as multiplexed pressure modules or electronic instrumentation with a IEEE 488 interface. The data system is designed to acquire data, convert it to engineering units, compute test dependent performance calculations, limit check selected channels or calculations, and display the information in alphanumeric or graphical form with a cycle time of one second for the alphanumeric data. This paper describes the system configuration, its salient features, and the expected impact on testing.

Fronek, Dennis L.↗

A distributed data acquisition system for aeronautics test facilities

The NASA Lewis Research Center is in the process of installing a new data acquisition and display system. This new system will provide small and medium sized aeronautics test facilities with a state-of-the-art real-time data acquisition and display system. The new data system will provide for the acquisition of signals from a variety of instrumentation sources. They include analog measurements of temperatures, pressures, and other steady state voltage inputs; frequency inputs to measure speed and flow; discrete I/O for significant events, and modular instrument systems such as multiplexed pressure modules or electronic instrumentation with a IEEE 488 interface. The data system is designed to acquire data, convert it to engineering units, compute test dependent performance calculations, limit check selected channels or calculations, and display the information in alphanumeric or graphical form with a cycle time of one second for the alphanumeric data. This paper describes the system configuration, its salient features, and the expected impact on testing.

Fronek, Dennis L.↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New High Channel-Count, High Scan-Rate, Data Acquisition System for the NASA Langley Transonic Dynamics Tunnel

A data acquisition system upgrade project, known as AB-DAS, is underway at the NASA Langley Transonic Dynamics Tunnel. AB-DAS will soon serve as the primary data system and will substantially increase the scan-rate capabilities and analog channel count while maintaining other unique aeroelastic and dynamic test capabilities required of the facility. AB-DAS is configurable, adaptable, and enables buffet and aeroacoustic tests by synchronously scanning all analog channels and recording the high scan-rate time history values for each data quantity. AB-DAS is currently available for use as a stand-alone data system with limited capabilities while development continues. This paper describes AB-DAS, the design methodology, and the current features and capabilities. It also outlines the future work and projected capabilities following completion of the data system upgrade project.

Ivanco, Thomas G.↗

High frequency data acquisition system for space shuttle main engine testing

The high frequency data acquisition system developed for the Space Shuttle Main Engine (SSME) single engine test facility at the National Space Technology Laboratories is discussed. The real time system will provide engineering data for a complete set of SSME instrumentation (approx. 100 measurements) within 4 hours following engine cutoff, a decrease of over 48 hours from the previous analog tape based system.

Lewallen, Pat↗

ASRC Aerospace Corporation Selects Dynamically Reconfigurable Anadigm(Registered Trademark) FPAA For Advanced Data Acquisition System

Anadigm(registered trademark) today announced that ASRC Aerospace Corporation has designed Anadigm's dynamically reconfigurable Field Programmable Analog Array (FPAA) technology into an advanced data acquisition system developed under contract for NASA. ASRC Aerospace designed in the Anadigm(registered trademark) FPAA to provide complex analog signal conditioning in its intelligent, self-calibrating, and self-healing advanced data acquisition system (ADAS). The ADAS has potential applications in industrial, manufacturing, and aerospace markets. This system offers highly reliable operation while reducing the need for user interaction. Anadigm(registered trademark)'s dynamically reconfigurable FPAAs can be reconfigured in-system by the designer or on the fly by a microprocessor. A single device can thus be programmed to implement multiple analog functions and/or to adapt on-the-fly to maintain precision operation despite system degradation and aging. In the case of the ASRC advanced data acquisition system, the FPAA helps ensure that the system will continue to operating at 100% functionality despite changes in the environment, component degradation, and/or component failures.

Mata, Carlos T.↗