Search NASA⌕ Search

SEARCH · Search NASA

Results for “data center cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assessment of Coupling One-Dimension and Three-Dimension CFD in Conjugate Heat Transfer Modeling and Simulations for Cooling of Turbine Engine

The CHT (conjugate heat transfer) modeling and simulation work fits under a bigger area in the TTT (Transformational Tools and Technologies) project called “Cooling Tools and Technologies for Combustor and Turbine.” The existing validation data sets such as TTT GRC (Glenn Research Center) THX (Turbulent Heat FLUX) IV experiments will be used to assess the solid/fluid heat transfer development and validation. The experimental configuration was a subsonic convergent nozzle with a square exit blowing a heated exhaust over an effusion-cooled deck. The simulation solutions were obtained and compared to experimental measurements of the profiles of flow velocities and temperatures, as well as deck surface temperatures. Cooling air blowing ratios of 0, 1, and 2 were considered. The three-dimensional cooling tubes were modelled by the medial axis of the cylindrical geometries due to large length over width ratios. It represented a typical coupling of one-dimension and three-dimension simulations of conjugate heat transfer approaches. The surface temperatures on the solid surfaces and the profiles of velocities and temperatures near the surfaces compared to the experimental data were presented.

nonlinear sub-filter stresses↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Review of convectively cooled structures for hypersonic flight

Resurgent interest in development of Aerospace Plane and Orient Express type vehicles promises to stretch structural technology for hypersonic flight vehicles to the uppermost limits. Significant portions of the structure may require active cooling of some type to survive hostile environments. Despite a lack of recent research activity for cooled structures, a significant body of unclassified knowledge exists concerning such structures. Contractual and in-house research conducted mainly by NASA's Langley Research Center during the 60's and 70's on vehicles very similar to the proposed Orient Express has provided a substantial data base for convectively cooled hypersonic flight structures. Specifically, results are presented for regeneratively cooled structural concepts which have a relatively high heat flux capability and use the hydrogen fuel directly as a coolant; and for structural concepts which use a secondary coolant loop to absorb incident heating and then transfer the absorbed heat to the liquid hydrogen fuel as it flows to the engines. Results are presented to indicate application regions in terms of heat flux capability for various concepts and benefits for each concept. Experience gained and costs are discussed in terms of heat flux capability for various concepts and benefits for each concept. Additionally, experience gained and cost involved with design, fabrication, and testing of full-scale convectively cooled structures are discussed.

Shore, Charles P.↗

Atacama Compact Array Measurements of the Molecular Mass in the NGC 5044 Cooling-Flow Group

The fate of cooling gas in the centers of galaxy clusters and groups is still not well understood, as is also the case for the complex processes of triggering star formation in central dominant galaxies, reheating of cooled gas by active galactic nuclei (AGN), and the triggering or “feeding” of supermassive black hole outbursts. We present CO observations of the early-type galaxy NGC 5044, which resides at the center of an X-ray bright group with a moderate cooling flow. For our analysis we combine CO(2−1) data from the 7 m antennae of the Atacama Compact Array (ACA) and the ACA total power array (TP). We demonstrate, using the 7 m array data, that we can recover the total flux inferred from IRAM 30 m single-dish observations, which corresponds to a total molecular mass of about 4 × 10(exp 7) M⨀ Most of the recovered flux is blueshifted with respect to the galaxy rest frame and is extended on kiloparsec-scales, suggesting low filling factor dispersed clouds. We find eight concentrations of molecular gas out to a radius of 10” (1.5 kpc), which we identify with giant molecular clouds. The total molecular gas mass is more centrally concentrated than the X-ray emitting gas but is extended in the northeast-southwest direction beyond the IRAM 30 m beam. We also compare the spatial extent of the molecular gas to the Hα emission: The CO emission coincides with the very bright Hα region in the center. We do not detect CO emission in the fainter Hα regions. Furthermore, we find two CO absorption features spatially located at the center of the galaxy, within 5 pc projected distance of the AGN, infalling at 255 and 265 km s(exp −1) relative to the AGN. This indicates that the two giant molecular clouds seen in absorption are most likely within the sphere of influence of the supermassive black hole.

Galaxy clusters↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Flow dynamics and bending of wide-angle tailed radio sources

The dynamics of tailed radio sources (WATs) is studied on the basis of VLA observations of 11 wide-angle WATs at 6 and 20 cm. These new images, in conjunction with optical and X-ray data, are used to describe the unifying characteristics of this class. WATs are found in centers of clusters without cooling cores, associated with galaxies of low space velocity. They are large sources, extending at least 50 kpc from the cluster center, and they have radio power close to the Fanaroff-Riley I/II break. The surface brightness and spectral distributions are used to model the flow fields and bending dynamics of the sources. Two limiting models are employed: the adiabatic model, in which no in situ energization takes place, and the kinetic model, in which all of the radio luminosity comes from in situ energization. It is found that the sources cannot be bent by the slow galaxy motion in the kinetic model. The sources can be bent by the ram pressure of a slowly moving central galaxy in the adiabatic model.

O'Donoghue, Aileen A.↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

Yonkers Urban Development: Utilizing NASA Earth Observations to Identify Environmental and Social Drivers of Urban Heat Vulnerability and Model Urban Cooling Interventions in Yonkers, New York

The City of Yonkers, New York, is located directly north of the Bronx in Westchester County and currently hosts a population of nearly 200,000. In response to increasing hot-weather episodes, the risk of heat-related illnesses and mortality is disproportionately affecting neighborhoods in Yonkers historically subjected to race-based housing segregation. NASA DEVELOP collaborated with Groundwork Hudson Valley to determine regions within Yonkers that are experiencing the most intense urban heat island effects, identify and rank sociodemographic and environmental determinants of increasing community-level vulnerability, map these vulnerabilities as a combined vulnerability index, complete a proximity analysis of walkability to local cooling centers and health facility locations, and model potential cooling strategies. The study area consisted of Yonkers, NY and the analyses used data from 2015-2020 (June through August). The project utilized NASA Earth observation products including Landsat 4 and 5 Thematic Mapper (TM), Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Terra Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). We assessed the benefits of different heat-mitigation scenarios by utilizing the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model. Results from these analyses can be used by Groundwork Hudson Valley, supporting the New York State’s Climate Safe Communities Certifiable Planning Actions, expanding knowledge on the relationship between historic redlining and environmental equity, and informing their Climate Safe Neighborhoods initiative to identify and prioritize mitigation efforts to abate the worst impacts of extreme heat.

Jillian Walechka↗

Project S'COOL

The Students Clouds Observations On-Line or S'COOL project was piloted in 1997. It was created with the idea of using students to serve as one component of the validation for the Clouds and the Earth's Radiant Energy System (CERES) instrument which was launched with the Tropical Rainfall Measuring Mission (TRMM) in November, 1997. As part of NASA's Earth Science Enterprise CERES is interested in the role clouds play in regulating our climate. Over thirty schools became involved in the initial thrust of the project. The CERES instrument detects the location of clouds and identifies their physical properties. S'COOL students coordinate their ground truth observations with the exact overpass of the satellite at their location. Their findings regarding cloud type, height, fraction and opacity as well as surface conditions are then reported to the NASA Langley Distributed Active Archive Center (DAAC). The data is then accessible to both the CERES team for validation and to schools for educational application via the Internet. By March of 1998 ninety-three schools, in nine countries had enrolled in the S'COOL project. Joining the United States participants were from schools in Australia, Canada, France, Germany, Norway, Spain, Sweden, and Switzerland. The project is gradually becoming the global project envisioned by the project s creators. As students obtain the requested data useful for the scientists, it was hoped that students with guidance from their instructors would have opportunity and motivation to learn more about clouds and atmospheric science as well.

Green, Carolyn J.↗

An investigation of Ekman upwelling in the North Atlantic

The spatial and temporal variability of the North Atlantic Ekman upwelling fields on seasonal and interannual time scales is investigated on the basis of surface winds from the Fleet Numerical Oceanography Center for 1979-1986. A pronounced minimum in the basin-wide monthly mean vertical Ekman velocities during 1981-1982 is found. It is shown that the primary source of the interannual signal was the region off NW Africa in the vicinity of the Guinea Dome. Other sectors of the basin experienced no significant interannual trends. Hydrographic data and SST data from the NW Africa sector for 1981-1986 indicate a cooling trend beginning in late 1982, consistent with increased upwelling. The fall and winter seasons' mixed layers at the center of the Guinea Dome were deeper in 1984 and 1985 than in previous years. The potential impact of large interannual variations in Ekman upwelling on basin-wide primary productivity is discussed.

Mcclain, Charles R.↗

Low-Cost Tracking Ground Terminal Designed to Use Cryogenically Cooled Electronics

A computer-controlled, tracking ground terminal will be assembled at the NASA Glenn Research Center at Lewis Field to receive signals transmitted by the Glenn's Direct Data Distribution (D3) payload planned for a shuttle flight in low Earth orbit. The terminal will enable direct data reception of up to two 622-megabits-per-second (Mbps) beams from the space-based, K-band (19.05-GHz) transmitting array at an end-user bit error rate of up to 10(exp -12). The ground terminal will include a 0.9-m-diameter receive-only Cassegrain reflector antenna with a corrugated feed horn incorporating a dual circularly polarized, K-band feed assembly mounted on a multiaxis, gimbaled tracking pedestal as well as electronics to receive the downlink signals. The tracking system will acquire and automatically track the shuttle through the sky for all elevations greater than 20 above the horizon. The receiving electronics for the ground terminal consist of a six-pole microstrip bandpass filter, a three-stage monolithic microwave integrated circuit (MMIC) amplifier, and a Stirling cycle cryocooler (1 W at 80 K). The Sterling cycle cryocooler cools the front end of the receiver, also known as the low-noise amplifier (LNA), to about 77 K. Cryocooling the LNA significantly increases receiver performance, which is necessary so that it can use the antenna, which has an aperture of only 0.9 m. The following drawing illustrates the cryoterminal.

Wald, Lawrence W.↗

S'COOL Provides Research Opportunities and Current Data for Today's Technological Classroom

NASA's Students' Cloud Observations On-Line (S'COOL) project, a hands-on educational project, was an innovative idea conceived by the scientists in the Radiation Sciences Branch at NASA Langley Research Center, Hampton, Virginia, in 1996. It came about after a local teacher expressed the idea that she wanted her students to be involved in real-life science. S'COOL supports NASA's Clouds and the Earth's Radiant Energy System (CERES) instrument, which was launched on the Tropical Rainforest Measuring Mission (TRMM) in November, 1997, as part of NASA's Earth Science Enterprise. With the S'COOL project students observe clouds and related weather conditions, compute data and note vital information while obtaining ground truth observations for the CERES instrument. The observations can then be used to help validate the CERES measurements, particularly detection of clear sky from space. In addition to meeting math, science and geography standards, students are engaged in using the computer to obtain, report and analyze current data, thus bringing modern technology into the realm of classroom, a paradigm that demands our attention.

Green, Carolyn J.↗

NEXUS-DC: Nuclear Energy eXpedition for US Data Centers [Slides]

This presentation covers the growing interest in utilizing nuclear power to satisfy the increasing energy demands of data centers in the United States, emphasizing the factors that accelerate reactor deployment. It addresses clean and reliable energy needs, highlights the importance of power supply redundancy for reliability, and discusses challenges and solutions related to cooling, waste heat reuse, and techno-economics. Additionally, it includes a strength, weakness, opportunities and threat analysis and emphasizes community engagement and collaboration for accelerating regulatory approvals and reactor deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal analysis of wildfires and effects on global ecosystem cycling

Biomass combustion plays an important role in the earth's biogeochemical cycling. The monitoring of wildfires and their associated variables at global scales is feasible and can lead to predictions of the influence of combustion on biogeochemical cycling and tropospheric chemistry. Remote sensing data collected during the 1985 California wildfire season indicate that the information content of key thermal and infrared/thermal wave band channels centered at 11.5 microns, 3.8 microns, and 2.25 microns are invaluable for discriminating and calculating fire related variables. These variables include fire intensity, rate-of-spread, soil cooling recovery behind the fire front, and plume structure. Coinciding Advanced Very High Resolution Radiometer (AVHRR) data provided information regarding temperature estimations and the movement of the smoke plume from one wildfire into the Los Angeles basin.

Ambrosia, Vincent G.↗

ExaDigiT/RAPS

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. RAPS either simulates workloads or replays historical workloads from system telemetry, and is able to predict dynamic energy consumption, as well as interact with the cooling model to predict cooling system behavior. Such a tool can be used together with reinforcement learning algorithms to provide an end-to-end optimization tool for data centers.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗

An experimental summary of plasma arc exposures of space shuttle high-temperature reusable surface insulation tile array with a single missing tile (conducted at the Ames Research Center)

A space shuttle high temperature reusable surface insulation (HRSI) tile array with a single missing or lost tile was exposed to a hot gas simulated reentry environment to investigate the heating conditions in and around the vicinity of the missing HRSI tile. Heat flux and pressure data for the lost tile condition were obtained by the use of a water cooled lost tile calibration model. The maximum aluminum substrate temperature obtained during the simulated reentry was 128 C (263 F). The lost tile calibration data indicated a maximum heat flux in the lost tile cavity region of 63 percent of the upstream reference value. This test was conducted at the Ames Research Center in the 20 MW semielliptical thermal protection system (TPS) pilot plasma arc test facility.

Galanter, S. A.↗

Amorphous magnetism in f.c.c. Vicalloy II

The results of magnetization and Mossbauer experiments are described which give evidence for superparamagnetism in the quenched face-centered-cubic (gamma) phase of the ternary system Fe .34, C .52, V .14 (Vicalloy II). Magnetometer data are given which clearly show that splat-cooled Vicalloy II does not exhibit long-range magnetic order. These data together with the Mossbauer data indicate that short-range magnetic ordering occurs which is temperature-dependent with coalescence of magnetic clusters over a limited temperature range. The model presented reasonably accounts for the observed effects and indicates that this ternary system is superparamagnetic down to 4.2 K.

Cusick, J. P.↗