Search NASA⌕ Search

SEARCH · Search NASA

Results for “data filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effluent characterization from a conical pressurized fluid bed

To obtain useable corrosion and erosion results it was necessary to have data with several levels of particulate matter in the hot gases. One level of particulate loading was as low as possible so that ideally no erosion and only corrosion occurred. A conical fluidized bed was used to obtain some degree of filtration through the top of the bed which would not be highly fluidized. This would minimize the filtration required for the hot gases or conversely the amount of particulate matter in the hot gases after a given level of filtration by cyclones and/or filters. The data obtained during testing characterized the effluent from the bed at different test conditions. A range of bed heights, coal flows, air flows, limestone flows, and pressure are represented. These tests were made to determine the best operating conditions prior to using the bed to determine erosion and corrosion rates of typical turbine blade materials.

Priem, R. J.↗

Annual Report for Hybrid Plasma Reactor/Filter for Transportable Collective Protection Systems—Phase 1B

Annual report covering the development of a hybrid nonthermal plasma single-pass filtration system for collective protection. This report covers NTP destruction testing on a high priority Toxic Industrial Material and an surrogate for a sulfur containing chemical agent (e.g. mustard), Effects of catalysts in the nonthermal plasma and catalyst poisoning by the sulfur are presented. Also presented are proof-of-principle data for utilizing ozone created in the NTP as a beneficial reactant to destroy adsorbed contaminants in-situ. Catalysts to decompose the ozone within the adsorbent bed are necessary to convert the adsorber into an ozone reactor.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector

Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-209-02: Percent Depth Dose Curves for Fluoroscopic X-Ray Beam Qualities Incorporating Copper Filtration

Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.

60 APPLIED LIFE SCIENCES↗

A virtual source model for Kilo-voltage cone beam CT: Source characteristics and model validation

Purpose: The purpose of this investigation was to study the source characteristics of a clinical kilo-voltage cone beam CT unit and to develop and validate a virtual source model that could be used for treatment planning purposes. Methods: We used a previously commissioned full Monte Carlo model and new bespoke software to study the source characteristics of a clinical kilo-voltage cone beam CT (CBCT) unit. We identified the main particle sources, their spatial, energy and angular distribution for all the image acquisition presets currently used in our clinical practice. This includes a combination of two energies (100 and 120 kVp), two filters (neutral and bowtie), and eight different x-ray beam apertures. We subsequently built a virtual source model which we validated against full Monte Carlo calculations. Results: We found that the radiation output of the clinical kilo-voltage cone beam CT unit investigated in this study could be reproduced with a virtual model comprising of two sources (target and filtration cone) or three sources (target, filtration cone and bowtie filter) when additional filtration was used. With this model, we accounted for more than 97% of the photons exiting the unit. Each source in our model was characterised by a origin distribution in both X and Y directions, a fluence map, a single energy spectrum for unfiltered beams and a two dimensional energy spectrum for bowtie filtered beams. The percentage dose difference between full Monte Carlo and virtual source model based dose distributions was well within the statistical uncertainty associated with the calculations ( {+-} 2%, one standard deviation) in all cases studied. Conclusions: The virtual source that we developed is accurate in calculating the dose delivered from a commercial kilo-voltage cone beam CT unit operating with routine clinical image acquisition settings. Our data have also shown that target, filtration cone, and bowtie filter sources needed to be all included in the model in order to accurately replicate the dose distribution from the clinical radiation beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data From: Influence of Hydrological Perturbations and Riverbed Sediment Characteristics on Hyporheic Zone Respiration of CO2 and N-2, Journal of Geophysical Research-Biogeosciences

This data package contains pumping data (.txt), parameter matrices, and R code (.R, .RData) to perform bootstrapping for parameter selection for the bioclogging model development. The pumping data were collected from the Russian River Riverbank Filtration site located in Sonoma County, California from 2010-2017 from three riverbank collection wells located alongside the study site. The pumping data is directly correlated with water table oscillations, so the code performs these correlations and simulates stochastic versions of water table oscillations. See Metadata Description.pdf for full details on dataset production. This dataset must be used with the R programming language. This dataset and R code is associated with the publication "Influence of Hydrological Perturbations and Riverbed Sediment Characteristics on Hyporheic Zone Respiration of CO2 and N-2"This research was supported by the Jane Lewis Fellowship from the University of California, Berkeley, the Sonoma County Water Agency (SCWA), the Roy G. Post Foundation Scholarship, the U.S. Department of Energy, Office of Science Graduate Student Research (SCGSR) Program, U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research under award DE-AC02-05CH11231, and the UFZ-Helmholtz Centre for Environmental Research, Leipzig, Germany.

54 ENVIRONMENTAL SCIENCES↗

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Reverse Osmosis (RO) are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in (ultra-filtration) UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square error (RMSE) metric. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent covariates across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is studied for both direct and recursive RF modelling approaches across increasing forecast horizons. Accurate prediction of initial TMP is critical for optimizing RO operations, as it enables the development of robust modelling frameworks by accurately estimating membrane fouling trends, thereby enhancing process efficiency and long-term reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Long-Term Statistical Process Monitoring of an Ultrafiltration Water Treatment Process

As water treatment technology has improved, the amount of available process data has substantially increased, making real-time, data-driven fault detection a reality. One shortcoming of the fault detection literature is that methods are usually evaluated by comparing their performance on hand-picked, short-term case studies, which yields no insight into long-term performance. In this work, we first evaluate multiple statistical and machine learning approaches for detrending process data. Then, we evaluate the performance of a PCA-based fault detection approach, applied to the detrended data, to monitor influent water quality, filtrate quality, and membrane fouling of an ultrafiltration membrane system for indirect potable reuse. Based on two short case studies, the adaptive lasso detrending method is selected, and the performance of the multivariate approach is evaluated over more than a year. The method is tested for different sets of three critical tuning parameters, and we find that for long-term, autonomous monitoring to be successful, these parameters should be carefully evaluated. However, in comparison with industry standards of simpler, univariate monitoring or daily pressure decay tests, multivariate monitoring produces substantial benefits in long-term testing.

ammonia↗

Ion Exchange Testing with SRF Resin FY2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.0, which was prepared and approved in response to the Test Specification 24590 PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590 PTF TEF RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Hanford Tank Waste Treatment and Immobilization Pl↗

Ion Exchange Testing with SRF Resin FY 2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.01, which was prepared and approved in response to the Test Specification 24590-PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590-PTF-TEF-RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Ion exchange↗

Developing Waste-Driven Design Requirements for Filtration and Ion-Exchange at the Hanford LAWPS Facility - 16394

The United States Department of Energy is building the Low Activity Waste Pretreatment System (LAWPS) at the Hanford site near Richland, Washington to treat liquid tank waste. The primary unit operations are filtration for solids removal and ion-exchange for cesium-137 removal. The properties of the stored waste are diverse, therefore the design requirements need to allow for a variety of feeds from the Hanford tank farms. However, it is not cost effective to allow a few rare feeds to define the requirements when there are other options for treating the rare wastes. The waste-derived design requirements were based on trends from this data. The primary feed requirements that will drive filtration and ion-exchange performance are solids content of the feed, cesium to sodium ratio, and potassium concentration. Additionally, aluminum and total organic carbon (TOC) concentrations are considered for flammable gas generation. For the cesium and potassium concentrations, the available experimental data was collected, sorted, and compared against the historic requirements. The design basis for cesium and potassium feed parameters developed here enveloped all but a couple outlier tanks. A review of available grab sample data indicates that occasionally the samples would have up to 0.8 wt% solids concentration. One single sample had 3.3 wt% solids concentration. These solids concentrations were assigned as the nominal and upper bounding solids concentrations. Flammable gas generation does not directly impact the ion exchange process throughput but does impact the design safety requirements, thus TOC and aluminum concentrations (which are inputs to the flammable gas calculations) were examined in a similar way, but were paired together through a simplified correlation to reach an upper bounding value of 0.6 wt% TOC*Al{sup 0.4}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Processing corrections for Skylab photographic imagery

Camera filters were inadvertently omitted from the six-channel multispectral photographic camera (S190A) during the exposure of the first roll of film from each channel on the final manned Skylab mission. Each of the films was overexposed and degraded as a result of the filter omissions. Explained are the techniques used by the NASA/JSC Photographic Technology Division to evaluate and process those films. These or similar techniques can be used in other photographic multispectral remote sensing applications in which black-and-white infrared and panchromatic or color infrared film are degraded due to loss of filtration or to overexposure. Results prove that data may be salvaged after camera exposure errors are made thus saving the expense of reacquiring data.

Lockwood, H. E.↗

Soluble and Particulate Mercury Deployment of Analytical Method for the Savannah River Site Liquid Waste System

Savannah River National Laboratory (SRNL) developed, tested, and deployed in a radiological containment unit (CU) an analytical method for quantifying particulate total mercury and soluble total mercury in radioactive samples such as the those generated by the dilution of Savannah River Site (SRS) High-Level Waste. This method relies on direct mercury analysis and other associated capabilities for matrix independent quantification of total mercury in solids or liquids (i.e., any sample that can be introduced into the instrument oven for pyrolysis to release all mercury for measurement). The matrix independence allows for discreet measurements of the starting sample, the collected particulates and the filtrate liquid, thus enabling a mass balance quality check. For example, an analysis of a diluted sample from the SRS liquid waste system (LWS) resulted in a measured total mercury value of 55.0 mg Hg/L and a nearly matching calculated total mercury value of 55.1 mg Hg/L (± 20% 2σ) from the summation of measured soluble mercury (47.8 mg Hg/L ± 20% 2σ) and measured particulate mercury (7.26 mg Hg/L ± 20% 2σ). The advantages of the particulate-soluble mercury analysis method are: waste minimization using small radioactive liquid volumes, minimal radiological sample processing and reduced handling steps protective of workers (ALARA) and improved data quality, syringe filter technology which eliminates vacuum filtration and the potential loss of volatile species, small diameter filters (13 mm nominal to 25 mm if needed to avoid clogging) and small disposable poly filter holders (no need to clean) which minimize waste, flexibility provided for a range of starting concentrations, particulate-soluble ratios, and sample matrix conditions, soluble and particulate are measured results that, when summed, and are in good agreement with the total mercury measurement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Ultra-filtration(UF) units are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square (RMSE) metric. Accurate prediction of initial TMP is critical for optimizing CCRO operations, as it enables the development of robust modelling frameworks that enhance process efficiency and reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Efficacy of fixed filtration for rapid kVp-switching dual energy x-ray systems

Purpose: Dose efficiency of dual kVp imaging can be improved if the two beams are filtered to remove photons in the common part of their spectra, thereby increasing spectral separation. While there are a number of advantages to rapid kVp-switching for dual energy, it may not be feasible to have two different filters for the two spectra. Therefore, the authors are interested in whether a fixed added filter can improve the dose efficiency of kVp-switching dual energy x-ray systems. Methods: The authors hypothesized that a K-edge filter would provide the energy selectivity needed to remove overlap of the spectra and hence increase the precision of material separation at constant dose. Preliminary simulations were done using calcium and water basis materials and 80 and 140 kVp x-ray spectra. Precision of the decomposition was evaluated based on the propagation of the Poisson noise through the decomposition function. Considering availability and cost, the authors chose a commercial Gd{sub 2}O{sub 2}S screen as the filter for their experimental validation. Experiments were conducted on a table-top system using a phantom with various thicknesses of acrylic and copper and 70 and 125 kVp x-ray spectra. The authors kept the phantom exposure roughly constant with and without filtration by adjusting the tube current. The filtered and unfiltered raw data of both low and high energy were decomposed into basis material and the variance of the decomposition for each thickness pair was calculated. To evaluate the filtration performance, the authors measured the ratio of material decomposition variance with and without filtration. Results: Simulation results show that the ideal filter material depends on the object composition and thickness, and ranges across the lanthanide series, with higher atomic number filters being preferred for more attenuating objects. Variance reduction increases with filter thickness, and substantial reductions (40%) can be achieved with a 2× loss in intensity. The authors’ experimental results validate the simulations, yet were overall slightly worse than expectation. For large objects, conventional (non-K-edge) beam hardening filters perform well. Conclusions: This study demonstrates the potential of fixed K-edge filtration to improve the dose efficiency and material decomposition precision for rapid kVp-switching dual energy systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗