Search NASA⌕ Search

SEARCH · Search NASA

Results for “data systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Determination of monitor unit check tolerances based on a comparison with measurement and treatment planning system data

ABSTRACT: This work describes the experimental validation of treatment planning system monitor unit (MU) calculations against measurement for a range of scenarios. This, together with a comparison of treatment planning system MUs and an independent MU check method, allows the derivation of confidence intervals for the check process. Data were collected for open and 60° motorized wedge fields using an Elekta Synergy linac at 6 and 8 MV using homogeneous and heterogeneous phantoms. Masterplan (Version 4.0) pencil-beam and collapsed cone algorithms were used for the primary MU calculations with full inhomogeneity correction. Results show that both algorithms agree with measurement to acceptable tolerance levels in the majority of the cases studied. The confidence interval for the pencil-beam algorithm MU against an independent check was determined as + 1.6% to −3.4%. This is modified to + 2.3% to −2.5% when data collected with low-density heterogeneities are removed as this algorithm is not used clinically for these cases. The corresponding interval for the collapsed cone algorithm was + 1.2% to −4.3%, indicating that an offset tolerance for the independent check is appropriate. Analysis of clinical conformal treatment plan data generated using the pencil-beam algorithm (1393 beams) returned 93% of beams within the independent check tolerance. Similarly, using the collapsed cone algorithm as the primary MU calculation, 77% (of 1434 beams) were within the confidence interval.

61 RADIATION PROTECTION AND DOSIMETRY↗

Community Emissions Data System

CEDS produces consistent estimates of global air emissions species data during the industrial era (1750 - present).

Source record↗

Mining Building Energy Management System Data Using Fuzzy Anomaly Detection and Linguistic Descriptions

Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD) based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Return On Investment of Engineered Geothermal Systems Data

The project provides an updated Energy Return on Investment (EROI) for Enhanced Geothermal Systems (EGS). Results incorporate Argonne National Laboratory's Life Cycle Assessment and base case assumptions consistent with other projects in the Analysis subprogram. EROI is a ratio of the energy delivered to the consumer to the energy consumed to build, operate, and decommission the facility. EROI is important in assessing the viability of energy alternatives. Currently EROI analyses of geothermal energy are either out-of-date, of uncertain methodology, or presented online with little supporting documentation. This data set is a collection of files documenting data used to calculate the Energy Return On Investment (EROI) of Engineered Geothermal Systems (EGS) and erratum to publications prior to the final report. Final report is available below, or from the OSTI web site (http://www.osti.gov/geothermal/). Data in this collections includes the well designs used, input parameters for GETEM, a discussion of the energy needed to haul materials to the drill site, the baseline mud program, and a summary of the energy needed to drill each of the well designs. EROI is the ratio of the energy delivered to the customer to the energy consumed to construct, operate, and decommission the facility. Whereas efficiency is the ratio of the energy delivered to the customer to the energy extracted from the reservoir.

15 GEOTHERMAL ENERGY↗

Performance Analysis: Issues Tracking System Data through June 2013

This report presents the results from an analysis of issues and assessments in LLNL’s Issues Tracking System (ITS). The analysis is conducted to identify issues that may require additional management attention and noncompliances that may not have been previously identified that meet the threshold for reporting to the DOE Noncompliance Tracking System (NTS) or to the DOE Safeguards and Security Information Management System (SSIMS). This report includes ITS data within the DOE Office of Enforcement regulated subjects through June 2013. The analysis in this report primarily focuses on deficiencies identified in the last twelve months. The analysis of issues concluded that data for 17 of the 25 Office of Enforcement regulated safety/security subjects were within expected variation. The data for eight met a common test and were discussed further. Three of the eight safety subjects met an action limit and were analyzed to resolution. Analysis of data from one of the safety subjects where a common test was met identified a potential safety related significant or programmatic (systemic) noncompliance with the LLNL work planning and control process. Additional analysis is needed to make a final determination. Note: Since the analysis of WPC deficiencies (through June 2013) was completed, a noncompliance evaluation was also completed in November 2013 and included more recent WPC deficiencies. The analysis of ITS data through June 2013, and the results of the noncompliance evaluation completed in November 2013 led to LLNL filing a programmatic noncompliance report to the NTS in January 2014 titled, Programmatic noncompliance with topical areas within LLNL’s Work Planning and Control process.

99 GENERAL AND MISCELLANEOUS↗

Interpretation of vadose zone monitoring system data near Engineered Trench 1

The E-Area Vadose Zone Monitoring System (VZMS) includes lysimeter sampling points at many locations alongside and angling beneath the Engineered Trench #1 (ET1) disposal unit footprint. The sampling points for ET1 were selected for this study because collectively they showed consistently higher tritium (H-3) concentrations than lysimeters associated with other trench units. The VZMS tritium dataset for ET1 from 2001 through 2015 comprises concentrations at or near background levels at approximately half of locations through time, concentrations up to about 600 pCi/mL at a few locations, and concentrations at two locations that have exceeded 1000 pCi/mL. The highest three values through 2015 were 6472 pCi/mL in 2014 and 4533 pCi/mL in 2013 at location VL-17, and 3152 pCi/mL in 2007 at location VL-15. As a point of reference, the drinking water standard for tritium and a DOE Order 435.1 performance objective in the saturated zone at the distant 100-meter facility perimeter is 20 pCi/mL. The purpose of this study is to assess whether these elevated concentrations are indicative of a general trend that could challenge 2008 E-Area Performance Assessment (PA) conclusions, or are isolated perturbations that when considered in the context of an entire disposal unit would support PA conclusions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tsunami Early Warning From Global Navigation Satellite System Data Using Convolutional Neural Networks

Abstract We investigate the potential of using Global Navigation Satellite System (GNSS) observations to directly forecast full tsunami waveforms in real time. We train convolutional neural networks to use less than 9 min of GNSS data to forecast the full tsunami waveforms over 6 hr at select locations, and obtain accurate forecasts on a test data set. Our training and test data consists of synthetic earthquakes and associated GNSS data generated for the Cascadia Subduction Zone using the MudPy software, and corresponding tsunami waveforms in Puget Sound computed using GeoClaw. We use the same suite of synthetic earthquakes and waveforms as in earlier work where tsunami waveforms were used for forecasting, and provide a comparison. We also explore varying the number of GNSS stations, their locations, and their observation durations.

Rim, Donsub↗

Black Swift Technologies S0 Uncrewed Aircraft System Data

This dataset includes atmospheric measurements obtained with the Black Swift Technologies S0 uncrewed aircraft system at the ARM SGP facility and a nearby mesonet site (Marshall). Flights were conducted over a one-week period, alongside platforms deployed by the University of Nebraska - Lincoln.

54 ENVIRONMENTAL SCIENCES↗

Cs-137 Body-burdens in Wild Pigs on the Department of Energy's Savannah River Site: Determination of an Appropriate Framework for Spatiotemporal Analysis of Hunter Dose Tracking System Data

The Savannah River Site (SRS) is a U.S. Department of Energy facility with an area of 310 square miles. Since its opening in 1951, SRS has produced and processed nuclear materials for national defense and industrial purposes. These activities have resulted in the release of radiocesium (Cs-137) which has led to contamination of associated streams, floodplains, man-made reservoirs, soil and vegetation. Contamination is spread to wild pigs as they move about SRS, consume vegetation, drink water and wallow in soil. SRS provides annual deer hunts open to the public in which wild pigs may be taken as well. The Cs-137 concentration of each animal is determined before it is released to the hunter for consumption and a cumulative dose is retained for each individual hunter. These tasks are accomplished using the Hunter Dose Tracking System (HDTS). The data collected on SRS by the HDTS for White-Tailed deer has been extensively analyzed. A repeatable method for calculating the background radiocesium body burden for the SRS deer population was established by Gaines and Novak (2009,2016). This model was framed using Cs-137 contamination obtained via gamma over-flight data, the decay rate of radiocesium and the historical behavior observed in the SRS deer population. These parameters were used in a spatiotemporal analysis to estimate background Cs-137 body burdens (from global fallout, etc.), as well as the effect SRS activities may have. The purpose of this project is to modify the framework to represent the behavior of the wild pig population on SRS such that HDTS data collected may be analyzed similarly. The 2018 data were collected via the HDTS in the field to screen wild pigs dispatched by Forest Service - Savannah River. These data will provide insight for an analysis of seasonal variance in the body burdens of the SRS wild pig population. The HDTS quickly provided Cs-137 concentrations in the field, as well as automatically updated the electronic database. Space: Historically, the average home range of wild pigs on the Savannah River Site has been reported at approximately six square miles. This range was confirmed accurate as of July 2018, with the observed minimum and maximum at one and ten square miles respectively. This range was geoprocessed using ArcMap to project buffers based on 1991 gamma over-flight data. The buffers were constructed to originate at all Cs-137 contamination point coordinates and protrude outward in all directions for 1.5, 2.45 and 6 square miles. While the 2.45 mile buffer is theoretically representative of potential hog exposure based on the average home range, it does not consider the possibility of home ranges not uniform in shape. Therefore, the 1.5 and 6 mile buffers were also constructed as visual aids for determining the appropriate hunt compartments for background level considerations. The SRS is divided into numbered hunt compartments of varying size and shape. These compartment numbers are used during sponsored hunts to record the location in which a wild pig was dispatched. Time: The Gaines report determined deer analysis should be carried out at the half-decade level for the best representation of true body burdens. This is due to the impact natural factors, such as drought or flood, can have on the bioaccumulation of Cs-137. To determine the appropriate time scale for hog analysis, all available data was totaled and averaged at 1, 2, 3 and 7 year increments. The annual averages and running average are provided. The appropriate compartments for the determination of the SRS hog population background level should be: 2, 3, 4, 9, 10, 14 and 15. Hogs dispatched within other compartments are most likely exposed to Cs-137 contamination and should not be included in the background level. The current dataset is small, but was still able to demonstrate the relationship between where hogs on SRS and the Cs-137 body burdens they incur. Geoprocessing the data using the average home range of wild pigs highlighted the importance of collecting additional samples from areas surrounding SRS if an accurate background is to be determined. When the average concentration of Cs-137 in pigs from background compartments is compared against that of pigs from contaminated compartments, a significant difference can be seen. A Table provides a summary of the analyzed data from the 15 years processed thus far.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Detection of Anomalies in Battery Energy Storage System Data

Data analytics is pivotal in assessing the technical characteristics and performance of Battery Energy Storage Systems (BESS), underpinning BESS modeling, optimization, and control. However, raw datasets frequently harbor anomalies from measurement errors and equipment malfunctions, impacting BESS reliability and analysis accuracy To address the challenge, this paper presents a novel methodology for the rapid detection of anomalous charge or discharge cycles within BESS operational data, expediting the cleaning process while ensuring data integrity. We’ve collected diverse and comprehensive real-world BESS operational datasets in collaboration with the Electric Power Research Institute and multiple Washington State utilities. These datasets serve dual roles: enabling comprehensive data exploration and analysis for understanding underlying challenges and method development, while also acting as a vital validation resource, demonstrating practical effectiveness. The proposed method detects anomalies and aids in their resolution, improving system performance characterization precision. It also reveals recurring data anomaly sources, offering insights for data collection and handling enhancement. Practitioners can gain valuable insights from the identified anomalous cycles in the real-world datasets along with the investigative process for root cause analyses and essential data cleaning steps.

Crawford, Aladsair J.↗

Engineering-Scale Integrated Energy System Data Projection Demonstration via the Dynamic Energy Transport and Integration Laboratory

The objective of this study is to demonstrate and validate the Dynamic Energy Transport and Integration Laboratory (DETAIL) preliminary scaling analysis using Modelica language system-code Dymola. The DETAIL preliminary scaling analysis includes a multisystem integral scaling package between thermal-storage and hydrogen-electrolysis systems. To construct the system of scaled equations, dynamical system scaling (DSS) was applied to all governing laws and closure relations associated with the selected integral system. The existing Dymola thermal-energy distribution system (TEDS) facility and high-temperature steam electrolysis (HTSE) facility models in the Idaho National Laboratory HYBRID repository were used to simulate a test case and a corresponding scaled case for integrated system HYBRID demonstration and validation. The DSS projected data based on the test-case simulations and determined scaling ratios were generated and compared with scaled case simulations. The preliminary scaling analysis performance was evaluated, and scaling distortions were investigated based on data magnitude, sequence, and similarity. The results indicated a necessity to change the normalization method for thermal storage generating optimal operating conditions of 261 kW power and mass flow rate of 6.42 kg/s and the possibility of reselecting governing laws for hydrogen electrolysis to improve scaling predictive properties. To enhance system-scaling similarity for TEDS and HTSE, the requirement for scaling validation via physical-facility demonstration was identified.

08 HYDROGEN↗

Acceptance Equipment System Data Acquisition and Processing Utility

My internship at Sandia National Laboratories took place in the Department of Sensors and Embedded Systems, which is tasked with, among many things, the non-destructive testing of thermal batteries. The Acceptance Equipment System (AES) is a flexible rack system designed to electrically test thermal batteries individually for internal defects before they are stored in the battery stock pile. Aside from individual testing, data acquired by the AES is used for many things including trending and catching outliers within the tolerance levels of a particular battery type, allowing for the development of more refined acceptance requirements and testing procedures.

25 ENERGY STORAGE↗

A Case Study Correlating Innovative Gamma Ray Scanning Detection Systems Data to Surface Soil Gamma Spectrometry Results - 13580

HydroGeoLogic (HGL), Inc. completed a United States Environmental Protection Agency (USEPA) study to characterize radiological contamination at a site near Canoga Park, California. The characterized area contained 470 acres including the site of a prototype commercial nuclear reactor and other nuclear design, testing, and support operations from the 1950's until 1988 [1]. The site history included radiological releases during operation followed by D and D activities. The characterization was conducted under an accelerated schedule and the results will support the project remediation. The project has a rigorous cleanup to background agenda and does not allow for comparison to risk-based guidelines. To target soil sample locations, multiple lines of evidence were evaluated including a gamma radiation survey, geophysical surveys, historical site assessment, aerial photographs, and former worker interviews. Due to the time since production and decay, the primary gamma emitting radionuclide remaining is cesium-137 (Cs-137). The gamma ray survey covered diverse, rugged terrain using custom designed sodium iodide thallium-activated (NaI(Tl)) scintillation detection systems. The survey goals included attaining 100% ground surface coverage and detecting gamma radiation as sensitively as possible. The effectiveness of innovative gamma ray detection systems was tested by correlating field Cs-137 static count ratios to Cs-137 laboratory gamma spectrometry results. As a case study, the area encompassing the former location of the first nuclear power station in the U. S. was scanned, and second by second global positioning system (GPS)-linked gamma spectral data were evaluated by examining total count rate and nuclide-specific regions of interest. To compensate for Compton scattering from higher energy naturally occurring radionuclides (U-238, Th-232 and their progeny, and K-40), count rate ratios of anthropogenic nuclide-specific regions of interest to the total count rate were calculated. From the scanning data, locations with observed Cs-137 ratios exceeding six standard deviations above the mean ratio were mapped in high resolution [2]. Field teams returned to those locations to collect static count measurements using the same detection systems. Soil surface samples were collected at 30 locations and analyzed for Cs-137. An exponential correlation was identified between Cs-137 concentrations in surface soil and field-scanned Cs-137 ratios. The data indicate field minimum detectable concentration (MDC) of Cs-137 at 0.02 Bq/g (0.5 pCi/g) or lower depending on contaminant distribution in soil. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Analysis: Issues Tracking System Data through September 2011

This report presents the results from an analysis of issues and assessments in LLNL’s Issues Tracking System (ITS). The analysis is conducted to identify issues that may require additional management attention and noncompliances that may not have been previously identified that meet the threshold for reporting to the DOE Noncompliance Tracking System (NTS) or to the DOE Safeguards and Security Information Management System (SSIMS).

99 GENERAL AND MISCELLANEOUS↗

Performance Analysis: Issues Tracking System Data through June 2012

This report presents the results from an analysis of issues and assessments in LLNL’s Issues Tracking System (ITS). The analysis is conducted to identify issues that may require additional management attention and noncompliances that may not have been previously identified that meet the threshold for reporting to the DOE Noncompliance Tracking System (NTS) or to the DOE Safeguards and Security Information Management System (SSIMS).

99 GENERAL AND MISCELLANEOUS↗

Operation and Maintenance of PV Systems: Data Science, Analysis, and Standards

This effort improves the effectiveness and reduce uncertainty in O&M cost through four primary objectives/tasks: 1) institutionalize standards for reliability and availability reporting for large PV power plants; 2) bridge systemic O&M knowledge gaps around important topics affecting O&M; 3) characterize systemic failure modes and patterns and accelerate O&M experiential learning cycles using field data; and 4) establish a baseline understanding of UPVS O&M cost drivers. Key results of this effort include publication of IEC standards, published topical papers on O&M topics, training, and characterize field data for climate- and service-related patterns (additional details below). Integrating these results serves to reduce performance risk and facilitate improvement in the way solar projects are operated and maintained. Results are well received and two publications are among the most successful SETO publications at NREL ("Model of Operation and Maintenance Costs for Photovoltaic Systems with over 40,000 downloads and "Best Practices in Operation and Maintenance of PV Systems, 3rd Ed." with over 90,000 downloads).

14 SOLAR ENERGY↗

Natural Systems Data Package for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This document summarizes the available information regarding the natural system (vadose zone and saturated zone) at the active trenches of the 200 West Area and 200 East Area Low-Level Burial Grounds (LLBGs). This information is relevant for developing the natural system fate and transport model for the update of the active trenches performance assessment. This document presents a description of the major features, events, and processes of the natural system at the active trenches of the 200 West Area and 200 East Area LLBGs that involves the geologic features or framework, and the vadose zone and groundwater flow and transport system. The description of the geologic features includes the following items: geologic setting, major structural features, major hydrostratigraphic units, and geologic framework. The discussion concerning vadose zone flow and transport at the active trenches of the 200 West Area and 200 East Area LLBGs includes the following topics: vadose zone features, events, and processes relevant to the development of the vadose zone conceptual model; hydrogeologic units and conditions; factors affecting moisture movement; and flow and transport properties of major units. The discussion concerning the groundwater flow and transport system in the vicinity of the active trenches of the 200 West Area and 200 East Area LLBGs includes the following topics: saturated zone features, events, and processes relevant to the saturated zone conceptual model; hydrogeologic units; groundwater flow conditions; and flow and transport properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗