Search NASA⌕ Search

SEARCH · Search NASA

Results for “dc fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Considerations for a Medium-Voltage DC Electrolysis Testbed

Here we present the results of a study focused on the feasibility of using Medium Voltage DC (MVDC) power distribution from wind power generation to electrolyzers for hydrogen production. This approach, using hybrid energy generation in a MVDC microgrid, offers many advantages. These include possible improvements in efficiency, reliability and installation cost compared to a more typical state-of-the-art AC distribution configuration. It also eliminates the need for transformers, which have recently been subject to price volatility and availability concerns. This study highlights the practical feasibility of MVDC distribution networks for integrating various energy sources, offering improved efficiency and reduced system complexity compared to conventional AC-based solutions. Future work will focus on enhancing fault protection strategies, scaling the system to larger renewable installations, and conducting hardware implementation at the National Renewable Energy Laboratory's (NREL) Flatirons Campus (FC). In the sections that follow we show that a DC Collection and Distribution System (DC CDS) reduces the losses associated with the electrical conversion / distribution process relative to a state-of-the-art AC approach, improving overall efficiency by 5%. On the qualitative side, reducing the number of conversion stages is likely to improve reliability, reduce capital investment cost, and enable simpler control algorithms to be used, and reduced risk of instabilities and malfunctions.

08 HYDROGEN↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of Physics-Based 0-10Hz Strong Motion Using High Performance Computing Supporting Refinements to Regional Ground Motion Models for the Central Eastern US

In collaboration with the U.S. Nuclear Regulatory Commission (NRC) the LLNL has developed a computationally efficient simulation platform designed to perform physics-based ground motion simulations for crustal earthquakes in the Stable Continental Regions of Central and Eastern US (CEUS), using high-performance computing. The main objective of the earthquake simulations was to use synthetic ground motion to provide constrains to refinements of existing ergodic Ground Motion Models (GMMs), for large magnitude earthquakes and near-fault distances, for which these models are less reliable. Physics-based broadband (0-10Hz) ground motion simulations were used to estimate the near-fault ground motion amplitudes and within event and between-event variabilities associated with fault rupture characteristics. In our simulations we used a 3D regional velocity model that was based on Saikia’s 1D velocity model (1994). In simulations performed during the first stage of this project the Saikia’s velocity model demonstrated better performance in modelling high frequency regional wave propagation for the CEUS region recorded during the Mw5.0 November 7, 2016, Cushing Oklahoma (Taylor et al., 2017), and Mw5.8 September 3, 2016, Pawnee Oklahoma earthquakes. The proposed regional 3D model includes random perturbations to the 1D background model using the stochastic scheme of Pitarka and Mellors (2021). In addition, validation analysis of the rupture generator and regional wave propagation models, using comparisons with different GMMs for Mw6.5 and Mw7.0 scenario earthquakes in the CEUS region resulted in a very good match between the simulated and empirical ground motion models. For the purposes of seismic hazard assessment at the existing and planned nuclear power plants, NRC is interested in studies aimed at improving the current ground motion models (GMM) for both Stable Continental Regions (SCR) in the Central and Eastern US and Active Crustal Regions (ACR) in the Western US. Due to lack of recorded data, these improvements require synthetic data for short fault distances and large magnitude earthquakes for which the existing recorded data is not enough to uniquely constrain the GMMs. The need for simulations and strong motion data is especially critical for the CEUS region where we do not have recorded data from potentially large damaging earthquakes with moment magnitudes 6.0 and higher. In this the project, we focused on 10Hz simulations of Mw7.0 scenario earthquakes with strike slip and thrust faulting mechanisms. We used more than 50 Mw7.0 earthquake rupture scenarios to investigate the ground motion uncertainty due to unknown earthquake rupture parameters, in particular, the slip distribution, rupture velocity, and faulting mechanism, and their implication on ground motion amplification due to forward rupture directivity effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison and Discussion on Shortcircuit Protections for Silicon-Carbide MOSFET Modules: Desaturation Versus Rogowski Switch-Current Sensor

Survivability of silicon-carbide (SiC) mosfet modules during short circuit (SC) is essential for modern power electronics systems due to large economic implications. SiC mosfet modules exhibit narrow SC withstand times and generally much lower SC robustness than silicon (Si) insulated-gate bipolar transistors (IGBTs). This puts a critical concern on their utilization, further stressing the importance of reliable protection. This article presents a comprehensive analysis and discussion on the SiC mosfet module SC protection and performance comparison between conventional desaturation detection, previously used for Si IGBT protection, and Rogowski switch-current sensor (RSCS) detection. In addition, this article presents the experimental design for soft turn-off as a reaction to the SC detection to avoid excessive overshoots during the abrupt turn-off of the SC current. To perform different types of SC with various fault inductances on different temperatures, and for the sake of fair comparison under the same conditions, a gate-driver unit for 1.2 kV SiC mosfet half-bridge modules is developed containing both detection methods. The results demonstrate that both methods are successful in protecting the module in all SC types, with superiority of the RSCS detection and concerns for desaturation detection in high-inductance and high dc-bus voltage SC events.

42 ENGINEERING↗

Anomalous Ferromagnetic Behavior in Orthorhombic Li 3 Co 2 SbO 6

Monoclinic Li 3 Co 2 SbO 6 has been proposed as a Kitaev spin liquid candidate and investigated intensively, whereas the properties of its polymorph, the orthorhombic phase, are less known. In this work, we report the magnetic properties of orthorhombic Li 3 Co 2 SbO 6 as revealed by dc and ac magnetic susceptibility, muon spin relaxation (μSR), and neutron diffraction measurements. Successive magnetic transitions at 115, 89, and 71 K were observed in the low-field dc susceptibility measurements. The transitions below T N (115 K) are suppressed at higher applied fields. However, zero-field ac susceptibility measurements reveal distinct frequency-independent transitions at about 114, 107, 97, 79, and 71 K. A long-range magnetic ordered state was confirmed by specific heat, μSR, and neutron diffraction measurements, all indicating a single transition at about 115 K. The discrepancy between different measurements is attributed to possible stacking faults and/or local disorders of the ferromagnetic zigzag chains, resulting in ferromagnetic boundaries within the overall antiferromagnetic matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid-Tied PV Inverter with Oversized Power Module to Increase its Low-Voltage Ride Through (LVRT) Capabilities and VAR Support

This paper proposes a novel design for grid-tied 3-ph Photovoltaic (PV) inverter to improve its low-voltage ride through (LVRT) response while significantly increasing its voltampere reactive (VAR) support during voltage sags. The literature available on LVRT for PV inverters can be grouped in solutions that dissipate the excess energy and those that temporary stores this energy. This paper proposes a third solution; oversizing inverter hardware components to safely transferring all the energy excess back to while maintaining the semiconductor under the maximum temperature limits. The advantages of the proposed approach are: 1) Improved LVRT capabilities and stable dc-link voltage control at MPP during sags. 2) Increased VAR support during voltage sags. 3) Increased use of renewable energy as all active power is injected back to the grid during voltage sags. Finally, the proposed solution is more cost effective compared with solutions that incorporate energy storage because only a few inverter components are required to be oversized. This paper also presents a detailed power loss analysis, which determined that that oversizing the power semiconductors has minimal impact in the inverter losses while significatively reducing the diode and IGBT conduction losses during both normal operation and grid fault conditions.

Ferrari Maglia, Max↗

Utah FORGE: Phase 3 Magnetotelluric (MT) Data

New high-quality tensor MT data at 122 sites, including the vertical magnetic field and utilizing ultra-remote referencing, have been acquired over the Utah FORGE project area. The results will be used to delineate the densities of faults and fractures in crystalline basement rocks, to define the heat sources, and to derive baseline 3D resistivity structure for later MT monitoring of temporal changes in resistivity structure following well stimulation in the EGS reservoir. There are three files here related to Utah FORGE magnetotelluric (MT) data acquisition and processing. The FORGE MT EDIs zip file contains the observed MT responses in industry-standard EDI format. For each site, there is an EDI response file that utilized a local independent reference for noise cancellation, and a file that utilized a distant reference cancelling noise associated with the DC transmission line of the Delta IPP passing down the west side of Milford Valley. These two site files could be merged as appropriate. The FORGE Model Cell Center file contains the model volume of the 3D Forge MT inversion for characterizing the resistivity structure in the project area. It was derived using finite element inversion methodology described in Wannamaker et al, in the attached FORGE Phase3 Geophysics paper, from the MT observation EDI files. It is ASCII format (.dat) and entries are defined at top of the file in a simple x-y-z-Rho listing in UTM coordinates. The element layers drape the topography so the Rho value layers are not purely horizontal slices. This greatly simplifies the listing.

15 GEOTHERMAL ENERGY↗

Determining circuit model parameters from operation data for PV system degradation analysis: $\mathrm{PVPRO}$

Physics-based circuit parameters like series and shunt resistance are essential to provide insights into the degradation status of photovoltaic (PV) arrays. However, calculating these parameters typically requires a full current-voltage characteristic (I-V curve), the acquisition of which involves specific measurement devices and costly methods. Thus, I-V curves of the PV system level are often not available. Here this paper proposes a methodology (PVPRO) to estimate these I-V curve parameters using only operation (string-level DC voltage and current) and weather data (irradiance and temperature). PVPRO first performs multi-stage data pre-processing to remove noisy data. Next, the time-series DC data are used to fit an equivalent circuit single-diode model (SDM) to estimate the circuit parameters by minimizing the differences between the measured and estimated values. In this way, the time evolutions of the SDM parameters are obtained. We evaluate PVPRO on synthetic datasets and find an excellent estimation of both SDM and the key I-V parameters (e.g., open-circuit voltage, short-circuit current, maximum power, etc.) with an average relative error of 0.55%. The performance, especially the extracted degradation rate of parameters, is robust to various measurement noises and the presence of faults. In addition, PVPRO is applied to a 271 kW PV field system. The relative error between the real and estimated operation voltage and current is less than 1%, suggesting that degradation trends are well captured. PVPRO represents a promising open-source tool to extract the time-series degradation trends of key PV parameters from routine operation data.

14 SOLAR ENERGY↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗