Search NASA⌕ Search

SEARCH · Search NASA

Results for “decay heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Unique safety features and licensing requirements of the NuScale small modular reactor

Small modular reactors (SMR) offer a novel approach to the construction and operation of nuclear power plants. The NuScale VOYGR™ plant uses a simplified SMR design that is based on proven light-water reactor technology with substantial improvements in nuclear safety. It consists of a 250 MWt reactor core housed with other primary system components in an integral reactor pressure vessel surrounded by a steel containment vessel, all of which is immersed in a large pool of water that also serves as the ultimate heat sink. At the core of the NuScale safety case are three primary safety systems: the decay heat removal system, the emergency core cooling system, and the containment. The ability of the NuScale Power Module (NPM) passive safety systems to remove core decay heat for an unlimited duration is demonstrated through analysis of a beyond-design-basis extended loss of AC power with no replenishment of water to the ultimate heat sink or operator actions. The NuScale methodology to evaluate an indefinite loss of AC power uses the proprietary NRELAP5 systems analysis computer code. Analysis results show that the reactor coolant system liquid level above the core is maintained and that containment pressure remains below the vessel design pressure. Once full passive air cooling is established, containment pressure and temperature will decrease over time with decreasing core decay heat. NuScale received standard design approval in September 2020 and design certification in January 2023 for its 50 MWe NPM configured as a 12 module plant. NuScale is currently seeking standard design approval to increase its core power to 250 MWt, nominally 77 MWe per module, in a 6-module plant (VOYGR™-6) configuration. The high-level safety of NuScale’s SMR technology is foundational to a new standard of nuclear power plant resilience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Iodine Effects on Medical Isotope Producer Delay & Guard Bed Temperature and Performance in Support of NA-23 Program

In support of NA-23’s objective to accelerate the establishment of a reliable commercial United States (U.S.) domestic supply of 99Mo produced without the use of highly enriched uranium (HEU), the Pacific Northwest National Laboratory (PNNL) was tasked with modeling the performance of activated carbon delay and guard beds that may be typical for non-HEU 99Mo production processes. The specific tasks accomplished by PNNL included calculations of long-term effects of iodine on delay bed performance and development of a finite element simulation to better understand delay bed performance under various scenarios specifically with radioxenon and radioiodine decay heating of the delay beds. The main issue of interest in this study is understanding the effect of iodine on the abatement performance of the beds if iodine is not sufficiently removed from gases prior to reaching the delay beds. Finite element simulations of delay bed performance were developed using COMSOL Multiphysics® Software. These simulations are based on partial differential equations that describe xenon and iodine adsorption, heat transfer and decay of radioxenon and radioiodine isotopes. Heat transfer in the activated carbon beds is simulated with a heat source tied to the decay of radioactive xenon and iodine species. These simulations were used to investigate delay bed temperature and hold up time using radioxenon and radioiodine activities and flowrates expected from a non-HEU production process. A bounding case scenario was simulated, where all the iodine was released into the delay beds due to insufficient guarding of the delay beds. In addition, preliminary investigations of the guard beds were conducted.

07 ISOTOPE AND RADIATION SOURCES↗

SCALE 6.2.4 Validation: Reactor Physics

This report is the third volume in a report series documenting the validation of SCALE 6.2.4, which is used herein with ENDF/B-VII.1 libraries, for nuclear criticality safety, reactor physics, and radiation shielding applications. This report focuses on validating SCALE capabilities that affect reactor physics applications. The experimental data used as basis for validation consists of measurement data for nuclide inventory, decay heat, and full-core experiments and include the following: 1. radiochemical assay measurements of 40 nuclides of importance to burnup credit, decay heat, and radiation shielding in 169 light-water reactor (LWR) spent nuclear fuel samples that cover burnups up to 70 GWd/MTU and initial enrichments up to 4.9% 235 U; 2. full-assembly decay heat measurements for 236 LWR assemblies with: a. initial fuel enrichments up to 4% 235 U, b. assembly burnups of 5–51 GWd/MTU, and c. cooling times after discharge in the 2- to 27-year range (of importance to spent nuclear fuel storage, transportation, and disposal); and 3. pulse fission irradiations for fissionable materials at cooling times of interest to severe accident analyses (<10 5 s). Validation examples for full-core analysis are based on startup experiments for the Watts Bar Nuclear Unit 1 (WBN1) pressurized water reactor (PWR) and two high-temperature gas-cooled reactor (HTGR) benchmarks for the HTR-10 pebble bed and the prismatic HTTR reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period October 2022-March 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary heat transport system to ensure temperatures in the reactor systems, structures and components with significant safety margins during normal operation and design basis accident scenarios. This third semi-annual report summarized the progress made at Argonne on the two tasks during the first half of FY23. As a part of the RCCS design task, a design process for the water panel and the system configuration was performed to improve the thermal performance of the RCCS. The updated water panel design had achieved enhanced thermal performance with 0.96 MWth capability with major design updates made in structural interfaces with the RPV and initial configuration of the water tanks. The loop configuration of the RCCS has been proposed to have two independently working loops for system redundancy. A water panel material study was performed focusing on the use of carbon steel in water systems. Additional modeling strategies of primary system thermal fluids analyses were developed to meet modeling needs that are not well suited for the 1D-3D assembly level approach. The first of these is a reduced order assembly model, in which fuel centered unit cells are used to represent a fuel assembly. The 2D approach used in this model is much more computationally efficient, making this model useful for full core transient scenarios where fuel to coolant heat transfer is still the dominant flow path. The next model is the 3D core conduction model to be used to analyze decay heat removal in loss of primary system flow scenarios. Because these scenarios require a large domain to be modeled, a homogenized core model is being pursued to reduce the required computational costs. To accurately model decay heat scenarios it is necessary to couple a RCCS model to the 3D core conduction model. A simplified case is presented to demonstrate how the coupling methodology will be applied to the full core 3D conduction model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Activation Analysis for the Inboard Region of FNSF Using SERPENT

This study describes an application of the SERPENT 2 code with the TENDL-2017 nuclear data library and the latest available model features of the Fusion Energy System Studies–Fusion Nuclear Science Facility (FNSF), to evaluate the activation of components after shutdown at 1, 10, and 100 years, assuming a plant lifetime of 8.5 full-power years. The primary parameters evaluated include the specific activity, decay heat, and waste disposal rating (WDR). The specific activity and decay heat are calculated with SERPENT 2 using a 360-deg model of the FNSF, while the WDR is calculated and classified based on the waste disposal limits established by the U.S. Nuclear Regulatory Commission under 10 CFR 61.55 as well as by using the Fetter approach. A python-based script developed for a previous high-level waste classification and analysis study was implemented and adapted to this research to calculate the WDR by comparing nuclide concentrations to the values established in 10 CFR 61.55 to generate a waste classification for each component surveyed. As only three short-lived isotopes have limitations for classifications beyond Class A, of which only 63Ni is present in appreciable quantities, there is a limit to the amount that short-lived isotopes contribute to the most significant waste analyzed here. In most cases, a handful of long-lived isotopes can be problematic, such as 59Ni and 94Nb, for example, which are solely responsible for multiple Class C classifications. The results herein reported heavily depend on the specific materials and mass/volume fractions in the specific model used in this study, which has changed and evolved since the inception of the FNSF concept and past studies. Furthermore, the more significant contributions of this study may be the development of a modeling and simulation toolkit and a strategy to perform these calculations, so to help evaluate and optimize future fusion facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Depletion Chain Simplification With Pseudo-Nuclides to Model Decay Effects

This work introduces the novel usage of pseudo-nuclides to model decay effects which are otherwise absent from simplified depletion libraries. Pseudo-nuclides are artificial nuclides which, when added to a simplified depletion library, can preserve quantities of interest such as decay energy release or decay photon activity which are otherwise significantly under-predicted by simplified libraries. Several dozen pseudo-nuclides are capable of accurately modeling decay effects of hundreds of short-lived radionuclides. The computational resources needed to model the decay effects in depletion systems with simplified depletion libraries with pseudo-nuclides are significantly less than those needed when using simplified depletion libraries without pseudo-nuclides. When compared to the similar method of decay heat precursors for a given system, pseudo-nuclides allow for smaller depletion libraries to be generated because of their ability to more accurately model the fission product irradiation effect on decay heat.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of SCALE and MELCOR for a generic pebble bed fluoride high-temperature reactor

This paper presents the development and application of SCALE and MELCOR models for a fluoride salt-cooled high-temperature reactor (FHR) based on publicly available specifications. SCALE version 6.3beta15 was used to generate power distributions and decay heat curves, and MELCOR version 2.2.18019 was used to calculate the thermal hydraulic response of an assumed FHR primary system. Here, an approach was developed for determining the equilibrium state of the core using depletion of a core slice model and blending of fuel compositions at different burnups to provide three-dimensional fuel composition in the core. Results compared between a core with entirely fresh fuel and one with an equilibrium fuel composition revealed that the equilibrium core led to lower steady-state temperatures but slower cooldown during a loss of flow accident (LOFA). A sensitivity study was then conducted to explore the transient response of our FHR system to variations in thermal hydraulic parameters of the system using the equilibrium core. The inlet temperature, graphite thermal conductivity, and SCRAM time all provided significant control over peak fuel and coolant temperatures. Uncertainties in radionuclide decay data in SCALE were used to perform a decay heat sensitivity study, and we found that uncertainties in decay heat led to negligible impact on peak temperatures during the course of the transient. In all cases evaluated, the observed peak fuel temperatures remained approximately 700 K below anticipated failure limits for the LOFA.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD-Chemical Model of One-Third Scale Demonstration of DOE Sealed Canister with ATR Fuel

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. A demonstration case for these DOE sealed canisters will be eventually performed with a one-third scale mockup that has been instrumented with thermocouples and gas concentration probes. This study seeks to model the planned canister for validation of the previously developed model, such that confidence in its long-term prediction can be increased. The deployment of the instrumented lid for online monitoring in intended for a period of 10+ years based on previous monitoring of commercial fuel storage; however, the model is still run for the previously used 50-year storage periods. This case is modeled with a G-value using a bi-linear function such that it decreases at higher dose rates to be consistent with experiments. Validation efforts of the model would likely revolve around the results for the 1st year, so the results of this timeframe are also highlighted. For dried fuel of the nominal decay heat (18W), the predicted hydrogen concentration is 0.19% after 1 year, 0.91% after 10 years, and 2.8% after 50 years, with a maximum pressure of 1.26 atm. Consistent with previous modeling, the decay heat of the fuel is the main factor that influences the results. For undried fuel in pure helium, the hydrogen concentration ranges from 0.23 to 1.2% after 1 year, 1.25-6.2% after 10 years and 8.8 to 18.84% after 50 years. For dried fuel in pure helium the hydrogen concentration ranges from 0.06% to 0.34% after 1 year, 0.35-2.11% after 10 years and 0.95 to 6.6% after 50 years. While long-term results in the presence of residual air are mostly the same, early reactions with O 2 can delay significant production of H 2 until it is consumed to form more water vapor, lowering the range to 0.14 to 1.0% after 1 year. The maximum absolute pressure that is reached across any scenario is 2.06 atm. In the event of residual air, the presence of nitric acid is possible in the range of 18-131 ppm after 1 year, 174-1180 ppm after 10 years, and 586-3500 ppm after 50 years. As long as the fuel is sufficiently dried, or of nominal decay heat, a 4% lower flammability limit of hydrogen will not be reached within a 10-year monitoring period.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Thermal-Hydraulic Effects of Dry Storage Canister Helium Backfill Loss Using the Horizontal Dry Cask Simulator

A previous investigation produced data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) was designed to generate this benchmark data and add to the existing knowledge base. The objective of the previous HDCS investigation was to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for a wide range of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate was of particular importance. The previous investigation explored these parameters using helium backfill at 100 kPa and 800 kPa pressure as well as air backfill with a series of simulated decay heats. The helium tests simulated a horizontal dry cask storage system at normal storage conditions with either atmospheric or elevated backfill pressure, while the air tests simulated horizontal storage canisters following a complete loss of helium backfill, in which case the helium would be replaced by air. The present HDCS investigation adds to the previous investigation by exploring steady-state conditions at various stages of the loss of helium backfill from a horizontal dry cask storage system. This is achieved by using helium/air blends as a backfill in the HDCS and running a series of tests using various simulated decay heats to explore the effects of relative helium/air molar concentration on the thermal response of a simulated horizontal dry cask storage system. A total of twenty tests were conducted where the HDCS achieved steady state for various assembly powers, representative of decay heat. The power levels tested were 0.50, 1.00, 2.50, and 5.00 kW. All tests were run at 100 kPa vessel pressure. The backfill gases used in these tests are given in this report as a function of mole fraction of helium (He), balanced by air: 1.0, 0.9, 0.5, 0.1, and 0.0 He. Steady-state conditions (where the steady-state start condition is defined as where the change in temperature with respect to time for the majority of HDCS components is less than or equal to 0.3 K/h) were achieved for all test cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-Neutron Transmutation of Used Nuclear Fuel (Final Report)

The primary goal of this study is to develop a national facility concept for transmuting long-lived fission products (LLFP) to substantially reduce the disposal impact by minimizing the need for a geologic-timescale repository. As a charter for this study, the national transmutation facility was required to reduce the radiotoxicity and decay heat of LLFP isotopes by at least 90% relative to their values at discharge from a commercial LWR, while consuming less than 10% of the reactor's energy. The identified LLFP isotopes are Se-79, Zr-93, Tc-99, I-129, Sn-126, and Cs-135, whose radiotoxicity is about 99% of the total radiotoxicity of all fission products at 1,000 years. Approximately ~72 kg of LLFPs is discharged every year from a 1,000 MWe commercial or advanced nuclear reactor. First, LLFP transmutation options with non-neutron beams (photons and protons) were explored. The study concluded that LLFP transmutation is feasible with high-energy, high-intensity photons or protons, but impractical on an engineering scale due to low transmutation rates and the high energy requirements to produce the desired photon or proton beams. As alternatives, LLFP transmutation options with neutrons from fission, fusion, and spallation reactions were additionally explored. The transmutation options using advanced critical reactors are attractive only for selective LLFP isotopes because the production rates of several LLFP isotopes (Zr-93, Sn-126, and Cs-135) from fission reactions are larger than the transmutation rates. The transmutation options with only spallation neutrons are favorable to transmute all LLFP isotopes, but as a tradeoff, the net transmutation rates are reduced. The national transmutation facility concept was developed following an exploration of transmutation options using various incident particles. The proposed national LLFP transmutation comprises a dedicated molten-salt reactor (MSR), a proton accelerator, and a spallation neutron-based transmuter. The MSR power was set at 300 MWt and 120 MWe, with the thermal power approximately 10% of that of a commercial 1,000 MWe PWR. The electricity generated by the MSR powers the accelerator and transmuter. The accelerator produces 1 GeV, 30 mA protons, which are introduced into the spallation neutron-based transmuter. The spallation neutron-based transmuter consists of a central spallation target and LLFP target pins merged in a heavy water tank. The six LLFP isotopes are separated into two groups. Tc-99, I-129, and Se-79, having larger neutron cross sections, belong to group A, while Zr-93, Sn126, and Cs-135, having smaller neutron cross sections, belong to group B. Then, for effective transmutation, LLFPs in groups A and B are transmuted in the dedicated MSR and in a spallation neutron-based transmuter, respectively. The estimated capital cost of the national transmutation facility is approximately $\$$3.1B, and its annual O&M cost is expected to be ~$\$$182M. Radiotoxicity and decay heat of LLFPs were calculated and compared with those of the original LLFPs. It was assumed that the targets were made with elementwise LLFP rather than isotopic LLFP, owing to the potentially high cost of isotopic separation from used nuclear fuels. The decay heat of LLFPs can be reduced by more than 90% using a single national transmutation facility. However, radiotoxicity decreases by 79–84%, which does not meet the transmutation performance requirement, primarily because Cs-135 is produced rather than depleted. Thus, to meet the design requirement, Cs-135 should be separated from other Cs isotopes and irradiated in a spallation neutron-based transmuter. Then, radiotoxicity decreases by ~92%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated power-following control for nuclear thermal propulsion startup and shutdown using MOOSE-based applications

This paper describes an investigation of various automated control strategies applied to a full-core multiphysics Griffin/Bison/RELAP-7 model of a prototypical nuclear thermal propulsion system. In all cases, control is achieved by actuating control drums based on the demanded power and predicted quantities from the numerical model. One key finding is that hybrid proportional integral derivative controllers – a novel type of controller that uses both power and reactivity predicted signals – can demonstrate a level of performance rivaling that of period-generated control. The former requires parameter tuning, while the latter mostly necessitates providing reactivity coefficients and temperature rates of change, which could be very challenging to accurately measure in real-time. In addition, decay heat plays an important role in determining cooling requirements during cooldown phases. A decay heat model, accounting for burn time and throttling, was derived, and is incorporated within the model to simulate the steady-state and shutdown phases and satisfyingly follow the power demand. However, temperature overshoots and non-constant specific impulse during throttling will necessitate further improvements.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preconceptual Design of Irradiated Fuel Salt Management System

The National Reactor Innovation Center was established by the U.S. Department of Energy to accelerate the demonstration and deployment of advanced nuclear reactors. To meet this mission, the National Reactor Innovation Center has developed the Laboratory for Operations and Testing in the U.S. (LOTUS) to support the first fast-spectrum molten salt reactor demonstration. The goal of this research is to understand the system requirements that may be applied to a molten salt reactor experiment in the LOTUS test bed and to perform systems analyses and preconceptual development of a storage container for the management of the irradiated molten salt fuel. This study proposes a set of irradiated fuel salt management processes for the molten salt reactor, from defueling to storage or disposal. For that, the historic Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has served as a crucial source of data for a mock application. This paper proposes a potential geometry for storing irradiated fuel salt based on MSRE data and the Monte Carlo N-Particle radiation transport code. The geometry was analyzed for criticality safety under abnormal situations, such as water ingress and interaction between containers. Based on the determined configuration of the storage system, the decay heat produced from the irradiated fuel salts was calculated to provide a reasonable time scale of the dormancy period. Using the same geometry assumed above, the neutron and gamma dose rates from the irradiated fuel salt at the end of the dormancy period were estimated, which will be useful for understanding the handling and radiation protection requirements for handling the irradiated fuel salt. Lastly, a reactor in the LOTUS test bed could use chloride-based fuel as opposed to the fluoride-based fuel used in MSRE. Thus, a literature study provided data to understand the similarities and differences between the characteristics of fluoride- and chloride-based salts in terms of salt chemistry, material characteristics, postirradiation behavior, neutronics, thermal hydraulics, and heat removal. This study, together with the proposed irradiated fuel salt management processes, preliminary criticality calculations, decay heat, and dose rate estimates, provides a strong basis for future investigation into the management of irradiated fuel salts generated during molten salt reactor technology demonstrations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for Thermal Annealing of Zr-Alloy Cladding During Dry Storage

In January 2025, the U.S. Department of Energy (DOE) sponsored a technical workshop with fuel vendors that provided a forum for increased collaboration on backend fuel cycle research. The workshop reviewed observations of thermal annealing of irradiated zirconium alloys in simulated dry storage conditions and discussed implications to the industry’s interest in reducing wet storage to optimize operational flexibility and the expected trend of increasing discharge burnup (and decay heats), which could lead to an increase in dry storage temperatures. One approach to accommodate increased decay heats in dry storage is to increase the regulatory temperature limit during dry storage, which is now 400°C. However, this could lead to thermal annealing of the cladding, which will tend to increase creep rates, creep strains, and ductility while decreasing yield strength. These considerations are compounded by bonding between the pellet and cladding at high burnup, which results in the pellet carrying more load during fuel rod deformations, especially in bending, which is the dominant deformation phenomenon in canister drop analyses. Because the U.S. Nuclear Regulatory Commission (NRC) recommends yield strength as a primary failure criterion for accident analyses in storage and transportation, particularly for canister drop scenarios, the purpose of the workshop was to develop options for alternative failure criterion that could replace yield strength in canister drop analyses. Topics discussed were (1) the regulatory framework, (2) the effect of thermal annealing on microhardness and tensile properties of cladding materials, (3) the effect of thermal annealing on fuel rod failure during bending, bending fatigue, and pinch loading, and (4) an alternative failure criterion for canister drop analyses. This paper provides a summary of the key discussions and outcomes of the workshop

Cantonwine, Paul [ORNL] (ORCID:0009000522247033)↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ring Model Development and Validation for Prismatic HTGR Core Thermal-hydraulics and Safety Analysis

Because of the complex core geometry, prismatic high temperature gas-cooled reactors (prismatic HTGRs) often exhibit complex thermal fluid behaviors during both normal operating and transient conditions. Most HTGR designs rely on passive safety system for decay heat removal, such as the reactor cavity cooling system (RCCS). During postulated accidents like Pressurized Conduction Cooldown (PCC) event, the decay heat is first radially transferred from the core region to the reactor vessel outer surface, then to the RCCS cooling panels. The peak fuel temperature is controlled by heat transfer mechanisms with two distinctive characteristic length scales, i.e., the core-wise effective heat conduction and local heat conduction in the fuel pellet scale. As both length scales are essential to determine the fuel temperature, from the modeling perspective, computer codes must be able to capture heat transfer in both scales. This is challenging for both computational fluid dynamics (CFD) tools because of extremely large amount of computation resources required, and for system analysis codes because of the challenge to model the complex core geometry. Under the support of DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, efforts have been pursued to support HTGR technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior during safety-related transients. In our previous studies, the ring model was adopted in SAM and further developed to simulate the normal operating condition and a PCC event using the MHTGR-350 design of General Atomics as the reference design. This current work represents a continuation of these previous efforts, and the focus is to critically review and examine simplifications and assumptions made to develop the ring model, and to perform code validation using experimental data from an integral-effect test facility, the High Temperature Test Facility (HTTF) at the Oregon State University. In this study, the test PG-27 from the HTTF test suite was selected for code validation purpose. The test PG-27 is a transient test designed to simulate the PCC event of the MHTGR design. Very good agreements between SAM prediction and experimental measurements were found in both coolant and solid structure temperatures during the transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗