Search NASA⌕ Search

SEARCH · Search NASA

Results for “deep stall”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

61 records · Page 4

Store separation from cavities at supersonic flight speeds

An experimental investigation has been conducted to determine the aerodynamic characteristics of a typical wing-control missile configuration during separation from a box-type cavity having depth to length ratios (D/L) ranging from 0.088 to 0.225. The cavity was located in a splitter plate that spanned the low Mach number test section of the Langley Unitary Plan Wind Tunnel. Aerodynamic characteristics are presented for Mach 2.36 and a free-stream unit Reynolds number of 2,000,000/ft. For the shallow cavity (D/L = 0.088), large interactions existed between the cavity and the flat plate flow field, which resulted in unfavorable separation characteristics for the missile model. For the deep cavity (D/L = 0.225), the flat plate flow field essentially bridged the cavity, resulting in minor interactions and favorable separation characteristics for the missile model.

Stallings, R. L., Jr.↗

Effects of surface baroclinicity on frontal overrunning along the central Gulf coast

Along the United States Gulf coast and over the northern Gulf of Mexico, frontal overrunning occurs frequently. Cyclogenesis over the Gulf is often associated with this type of weather system. Effects of baroclinic fields on frontal overrunning are investigated from synoptic and climatological points of view. It is found that, from October through April, the orientation of the shelf break is a very important baroclinic characteristic because fronts tend to stall there rather than at the physical coastline. To further substantiate this deduction dynamically, the local geostrophic vorticity field over the western Louisiana-upper Texas shelf region is estimated monthly. The correlation coefficient between the vorticity field and the frequency of frontal overrunning along the central Gulf coast was 0.86. For forecasting applications, a simple formula is provided to estimate this local vorticity from the temperature difference between Lake Charles, Louisiana, and buoy station 42002 in the deep Gulf.

Hsu, S. A.↗

A Historical Systems Study of Liquid Rocket Engine Throttling Capabilities

This is a comprehensive systems study to examine and evaluate throttling capabilities of liquid rocket engines. The focus of this study is on engine components, and how the interactions of these components are considered for throttling applications. First, an assessment of space mission requirements is performed to determine what applications require engine throttling. A background on liquid rocket engine throttling is provided, along with the basic equations that are used to predict performance. Three engines are discussed that have successfully demonstrated throttling. Next, the engine system is broken down into components to discuss special considerations that need to be made for engine throttling. This study focuses on liquid rocket engines that have demonstrated operational capability on American space launch vehicles, starting with the Apollo vehicle engines and ending with current technology demonstrations. Both deep throttling and shallow throttling engines are discussed. Boost and sustainer engines have demonstrated throttling from 17% to 100% thrust, while upper stage and lunar lander engines have demonstrated throttling in excess of 10% to 100% thrust. The key difficulty in throttling liquid rocket engines is maintaining an adequate pressure drop across the injector, which is necessary to provide propellant atomization and mixing. For the combustion chamber, cooling can be an issue at low thrust levels. For turbomachinery, the primary considerations are to avoid cavitation, stall, surge, and to consider bearing leakage flows, rotordynamics, and structural dynamics. For valves, it is necessary to design valves and actuators that can achieve accurate flow control at all thrust levels. It is also important to assess the amount of nozzle flow separation that can be tolerated at low thrust levels for ground testing.

Betts, Erin M.↗

Measurements of store forces and moments and cavity pressures for a generic store in and near a box cavity at subsonic and transonic speeds

An experimental force and moment study was conducted in the Langley 8-Foot Transonic Pressure Tunnel for a generic store in and near rectangular box cavities contained in a flat-plate configuration at subsonic and transonic speeds. Surface pressures were measured inside the cavities and on the flat plate. The length-to-height ratios were 5.42, 6.25, 10.83, and 12.50. The corresponding width-to-height ratios were 2.00, 2.00, 4.00, and 4.00. The free-stream Mach number range was from 0.20 to 0.95. Surface pressure measurements inside the cavities indicated that the flow fields for the shallow cavities were either closed or transitional near the transitional/closed boundary. For the deep cavities, the flow fields were either open or near the open/transitional boundary. The presence of the store did not change the type of flow field and had only small effects on the pressure distributions. For transitional or open transitional flow fields, increasing the free-stream Mach number resulted in large reductions in pitching-moment coefficient. Values of pitching-moment coefficient were always much greater for closed flow fields than for open flow fields.

Stallings, Robert L., Jr.↗

Measurements of forces, moments, and pressures on a generic store separating from a box cavity at supersonic speeds

An experimental investigation was conducted to measure the forces, moments, and pressure distributions on the generic store separating from a rectangular box cavity contained in a flat plate surface at supersonic speeds. Pressure distributions inside the cavity and oil flow and vapor-screen photographs of the cavity flow field were also obtained. The measurements were obtained for the store separating from a flat plate surface, from two shallow cavities having length to depth ratios (L/h) of 16.778 and 12.073, and from a deep cavity having L/h = 6.730. Measurements for the shallow cavities were obtained both with and without rectangular doors attached to sides of the cavities. The tests were conducted at free stream Mach numbers of 1.69, 2.00 and 2.65 for a free stream Reynolds number per foot of 2 x 10(exp 6). Presented here are a discussion of the results, a complete tabulation of the pressure data, figures of both the pressure and force and moment data, and representative oil flow and vapor screen photographs.

Stallings, Robert L., Jr.↗

Unsteady viscous calculations of supersonic flows past deep and shallow three-dimensional cavities

Computational simulations were performed for supersonic, turbulent flows over deep and shallow three-dimensional cavities. The width and the depth of these cavities were fixed at 2.5 in. and 0.5 in., respectively. Length-to-depth ratio of the deep cavity was 6 and that of the shallow cavity was 16. Freestream values of Mach number and Reynolds number were 1.50 and 2.0 x 10 to the 6th/ft., respectively, at a total temperature of 585 R. The thickness of the turbulent boundary layer at the front lip of the cavity was 0.2 in. Simulations of these oscillatory flows were generated through time-accurate solutions of Reynolds-averaged full Navier-Stokes equations using the explicit MacCormack scheme. The solutions are validated through comparisons with experimental data. The features of open and closed cavity flows and effects of the third dimension are illustrated through computational graphics.

Baysal, O.↗

Supersonic axial-force characteristics of a rectangular-box cavity with various length-to-depth ratios in a flat plate

A wind-tunnel investigation has been conducted at Mach numbers of 1.50, 2.16, and 2.86 to obtain axial-force data on a metric rectangular-box cavity with various length-to-depth ratios. The model was tested at angles of attack from -4 deg to -2 deg. The results are summarized to show variations in cavity axial-force coefficient for deep- and shallow-cavity configurations with detached and attached cavity flow fields, respectively. The results of the investigation indicate that for a wide range of cavity lengths and depths, good correlations of the cavity axial-force coefficients (based on cavity rear-face area) are obtained when these coefficients are plotted as a function of cavity length-to-depth ratio. Abrupt increases in the cavity axial-force coefficients at an angle of attack of 0 deg. reflect the transition from an open (detached) cavity flow field to a closed (attached) cavity flow field. Cavity length-to-depth ratio is the dominant factor affecting the switching of the cavity flow field from one type to the other. The type of cavity flow field (open or closed) is not dependent on the test angles of attack except near the critical value of length-to-depth ratio.

Blair, A. B., Jr.↗