Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data Compression Algorithm Architecture for Large Depth-of-Field Particle Image Velocimeters

A large depth-of-field particle image velocimeter (PIV) is designed to characterize dynamic dust environments on planetary surfaces. This instrument detects lofted dust particles, and senses the number of particles per unit volume, measuring their sizes, velocities (both speed and direction), and shape factors when the particles are large. To measure these particle characteristics in-flight, the instrument gathers two-dimensional image data at a high frame rate, typically >4,000 Hz, generating large amounts of data for every second of operation, approximately 6 GB/s. To characterize a planetary dust environment that is dynamic, the instrument would have to operate for at least several minutes during an observation period, easily producing more than a terabyte of data per observation. Given current technology, this amount of data would be very difficult to store onboard a spacecraft, and downlink to Earth. Since 2007, innovators have been developing an autonomous image analysis algorithm architecture for the PIV instrument to greatly reduce the amount of data that it has to store and downlink. The algorithm analyzes PIV images and automatically reduces the image information down to only the particle measurement data that is of interest, reducing the amount of data that is handled by more than 10(exp 3). The state of development for this innovation is now fairly mature, with a functional algorithm architecture, along with several key pieces of algorithm logic, that has been proven through field test data acquired with a proof-of-concept PIV instrument.

Bos, Brent↗

Semi-automatic image annotation using 3D LiDAR projections and depth camera data

Efficient image annotation is necessary to utilize deep learning object recognition neural networks in nuclear safeguards, such as for the detection and localization of target objects like nuclear material containers (NMCs). This capability can help automate the inventory accounting of different types of NMCs within nuclear storage facilities. The conventional manual annotation process is labor-intensive and time-consuming, hindering the rapid deployment of deep learning models for NMC identifications. This paper introduces a novel semi-automatic method for annotating 2D images of nuclear material containers (NMCs) by combining 3D light detection and ranging (LiDAR) data with color and depth camera images collected from a handheld scan system. The annotation pipeline involves an operator manually marking new target objects on a LiDAR-generated map, and projecting these 3D locations to images, thereby automatically creating annotations from the projections. The semi-automatic approach significantly reduces manual efforts and the expertise in image annotation that is required to perform the task, allowing deep learning models to be trained on-site within a few hours. The paper compares the performance of models trained on datasets annotated through various methods, including semi-automatic, manual, and commercial annotation services. The evaluation demonstrates that the semi-automatic annotation method achieves comparable or superior results, with a mean average precision (mAP) above 0.9, showcasing its efficiency in training object recognition models. Additionally, the paper explores the application of the proposed method to instance segmentation, achieving promising results in detecting multiple types of NMCs in various formations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Simultaneous Two- and Three-Photon Deep Imaging of Autofluorescence in Bacterial Communities

The intrinsic fluorescence of bacterial samples has a proven potential for label-free bacterial characterization, monitoring bacterial metabolic functions, and as a mechanism for tracking the transport of relevant components through vesicles. The reduced scattering and axial confinement of the excitation offered by multiphoton imaging can be used to overcome some of the limitations of single-photon excitation (e.g., scattering and out-of-plane photobleaching) to the imaging of bacterial communities. In this work, we demonstrate in vivo multi-photon microscopy imaging of Streptomyces bacterial communities, based on the excitation of blue endogenous fluorophores, using an ultrafast Yb-fiber laser amplifier. Its parameters, such as the pulse energy, duration, wavelength, and repetition rate, enable in vivo multicolor imaging with a single source through the simultaneous two- and three-photon excitation of different fluorophores. Three-photon excitation at 1040 nm allows fluorophores with blue and green emission spectra to be addressed (and their corresponding ultraviolet and blue single-photon excitation wavelengths, respectively), and two-photon excitation at the same wavelength allows fluorophores with yellow, orange, or red emission spectra to be addressed (and their corresponding green, yellow, and orange single-photon excitation wavelengths). We demonstrate that three-photon excitation allows imaging over a depth range of more than 6 effective attenuation lengths to take place, corresponding to an 800 micrometer depth of imaging, in samples with a high density of fluorescent structures.

59 BASIC BIOLOGICAL SCIENCES↗

Self-Motion and Depth Estimation from Image Sequences

An image-based version of a computational model of human self-motion perception (developed in collaboration with Dr. Leland S. Stone at NASA Ames Research Center) has been generated and tested. The research included in the grant proposal sought to extend the utility of the self-motion model so that it could be used for explaining and predicting human performance in a greater variety of aerospace applications. The model can now be tested with video input sequences (including computer generated imagery) which enables simulation of human self-motion estimation in a variety of applied settings.

Perrone, John↗

Depth-First Search Image Chasing

This presentation contains results from work on an active NNSS Site-directed research and development (SDRD) project: NLV-019-20. It describes a new algorithm for "few-angle tomography", which can be used to reconstruct an approximation to an object from limited quantities or radiographs under specific conditions. This presentation is an initial documentation of research results thus-far, and we would like to share these methods with colleagues at Lawrence Livermore National Lab who have an expertise in the area of few-angle tomography. Sharing this presentation will be done via email and or teleconference amongst DoE personnel. In the future, we would also like to share these results with collaborators from Academia as well.

97 MATHEMATICS AND COMPUTING↗

Constraining primordial non-Gaussianity from DESI quasar targets and Planck CMB lensing

We detect the cross-correlation between 2.7 million DESI quasar targets across 14,700 deg 2 (180 quasars deg -2 ) and Planck 2018 CMB lensing at ~30σ. We use the cross-correlation on very large scales to constrain local primordial non-Gaussianity via the scale dependence of quasar bias. The DESI quasar targets lie at an effective redshift of 1.51 and are separated into four imaging regions of varying depth and image quality. We select quasar targets from Legacy Survey DR9 imaging, apply additional flux and photometric redshift cuts to improve the purity and reduce the fraction of unclassified redshifts, and use early DESI spectroscopy of 194,000 quasar targets to determine their redshift distribution and stellar contamination fraction (2.6%). Due to significant excess large-scale power in the quasar autocorrelation, we apply weights to mitigate contamination from imaging systematics such as depth, extinction, and stellar density. We use realistic contaminated mocks to determine the greatest number of systematic modes that we can fit, before we are biased by overfitting and spuriously remove real power. We find that linear regression with one to seven imaging templates removed per region accurately recovers the input cross-power, f NL and linear bias. As in previous analyses, our fNL constraint depends on the linear primordial non-Gaussianity bias parameter, b Φ = 2(b - p)δ c assuming universality of the halo mass function. We measure f NL = -26 +45 -40 with p = 1.6 (f NL = -18 +29 -27 with p = 1.0), and find that this result is robust under several systematics tests. Future spectroscopic quasar cross-correlations with Planck lensing can tighten the f NL constraints by a factor of 2 if they can remove the excess power on large scales in the quasar auto power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Particle-Image Velocimeter Having Large Depth of Field

An instrument that functions mainly as a particle-image velocimeter provides data on the sizes and velocities of flying opaque particles. The instrument is being developed as a means of characterizing fluxes of wind-borne dust particles in the Martian atmosphere. The instrument could also adapted to terrestrial use in measuring sizes and velocities of opaque particles carried by natural winds and industrial gases. Examples of potential terrestrial applications include monitoring of airborne industrial pollutants and airborne particles in mine shafts. The design of this instrument reflects an observation, made in field research, that airborne dust particles derived from soil and rock are opaque enough to be observable by use of bright field illumination with high contrast for highly accurate measurements of sizes and shapes. The instrument includes a source of collimated light coupled to an afocal beam expander and an imaging array of photodetectors. When dust particles travel through the collimated beam, they cast shadows. The shadows are magnified by the beam expander and relayed to the array of photodetectors. Inasmuch as the images captured by the array are of dust-particle shadows rather of the particles themselves, the depth of field of the instrument can be large: the instrument has a depth of field of about 11 mm, which is larger than the depths of field of prior particle-image velocimeters. The instrument can resolve, and measure the sizes and velocities of, particles having sizes in the approximate range of 1 to 300 m. For slowly moving particles, data from two image frames are used to calculate velocities. For rapidly moving particles, image smear lengths from a single frame are used in conjunction with particle- size measurement data to determine velocities.

Bos, Brent↗

Comparison of Coincident Multiangle Imaging Spectroradiometer and Moderate Resolution Imaging Spectroradiometer Aerosol Optical Depths over Land and Ocean Scenes Containing Aerosol Robotic Network Sites

The Multiangle Imaging Spectroradiometer (MISR) and the Moderate Resolution Imaging Spectroradiometer (MODIS), launched on 18 December 1999 aboard the Terra spacecraft, are making global observations of top-of-atmosphere (TOA) radiances. Aerosol optical depths and particle properties are independently retrieved from these radiances using methodologies and algorithms that make use of the instruments corresponding designs. This paper compares instantaneous optical depths retrieved from simultaneous and collocated radiances measured by the two instruments at locations containing sites within the Aerosol Robotic Network (AERONET). A set of 318 MISR and MODIS images, obtained during the months of March, June, and September 2002 at 62 AERONET sites, were used in this study. The results show that over land, MODIS aerosol optical depths at 470 and 660 nm are larger than those retrieved from MISR by about 35% and 10% on average, respectively, when all land surface types are included in the regression. The differences decrease when coastal and desert areas are excluded. For optical depths retrieved over ocean, MISR is on average about 0.1 and 0.05 higher than MODIS in the 470 and 660 nm bands, respectively. Part of this difference is due to radiometric calibration and is reduced to about 0.01 and 0.03 when recently derived band-to-band adjustments in the MISR radiometry are incorporated. Comparisons with AERONET data show similar patterns.

Moderate Resolution Imaging Spectroradiometer (MOD↗

Viscous relaxation of impact craters on icy planetary surfaces - Determination of viscosity variation with depth

Spacecraft images show that the icy Galilean satellites have surfaces with very low topographic relief. Impact craters on Ganymede and Callisto are anomalously shallow and are characterized by sharp well-defined rims and domed floors. These morphological characteristics can be explained by viscous relaxation of topography on an icy crust in which the viscosity is uniform or decreases with depth. Under these conditions, large craters relax more rapidly than small craters, therefore explaining a possible underabundance of large craters. Viscous relaxation on an icy crust that is thin compared to the crater diameter or on a thick icy crust in which viscosity increases with depth could not produce this crater morphology and would result in the more rapid relaxation of small craters rather than large craters. The results of this study suggest that more detailed analysis of relaxing impact crater morphology may resolve the rate of viscosity decrease with depth and so provide evidence on the interior thermal evolution of icy planetary bodies.

Parmentier, E. M.↗

Ultra-compact Imaging Technology (CRADA Final Report)

As part of the Cyclotron Road program, Synopic (formerly FlatCam LLC) sought to investigate the benefits of its depth-sensitive imaging techniques. The basic principle involved using a thin mask specially designed to encode light reaching a sensor, in conjunction with optimized computational algorithms, in such a manner that allowed for both miniaturization of imaging systems and improved computation toward high resolution, three-dimensional imaging. By thoroughly exploring the resolution, mask/optical design, and algorithmic capabilities of our depth sensitive technology, we expand the potential applications for (but not limited to) medical, consumer and industrial purposes. The project aimed to develop new imaging systems by building on previous work and using 1) materials capable of modulating and 2) sensors capable of measuring visible and longer wavelengths. Preliminary research was conducted to design, fabricate and characterize imaging systems with the goal of improving resolution, enhancing single capture, three-dimensional imaging, and extending depth of field of captured images. The primary goal was to determine whether adapting the depth-sensitive imaging system is feasible, and early results are promising.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: A pilot ex vivo study

Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped with a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that ultimately may allow US-based real-time intraoperative dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crack Offset Measurement With the Projected Laser Target Device

The device and associated analysis methodology summarized in this report were developed for the purpose of estimating the size of discontinuities in the surface of the foam that covers the Space Shuttle External Tank. These surface offsets are thought to be due to subsurface cracks in the foam insulation. The mathematical analysis and procedure described here provide a method to quantity the dimensions of the crack offset in a direction perpendicular to the surface, making use of the projected laser target device (PLTD) tool and a laser line projector. The keys to the construction and use of the PLTD are the following geometrical design requirements: Laser dots are on a square grid: length on a side. Laser beams are perpendicular to projected surface. Beams are parallel out to the distance being projected. The PLTD can be used to (1) calibrate fixed cameras of unknown magnification and orientation (far-field solution); (2) provide equivalent calibration to multiple cameras, previously achieved only by the use of known target points, for example, in 3.D foreign-object debris tracking on a fixed launch platform; (3) compute scaling for conventional 2.D images, and depth of field for 3.D images (near-field solution); and (4) in conjunction with a laser line projector, achieve accurate measurements of surface discontinuity (cracks) in a direction perpendicular to the surface.

Source record↗