Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantitative guidance for efficient vertical flow measurements at the sediment–water interface using temperature–depth profiles

Upward discharge to surface water bodies can be quantified using analytical models based on temperature–depth (T-z) profiles. The use of sediment T-z profiles is attractive as discharge estimates can be obtained using point-in-time data that are collected inexpensively and rapidly. Previous studies have identified that T-z methods can only be applied at times of the year when there is significant difference between the streambed–water interface and deeper sediment temperatures (e.g., winter and summer). However, surface water temperatures also vary diurnally, and the influence of these variations on discharge estimates from T-z methods is poorly understood. For this study, synthetic T-z profiles were generated numerically using measured streambed interface temperature data to assess the influence of diurnal temperature variations on discharge estimation and provide insight into the suitable application of T-z methods. Results show that the time of day of data collection can have a substantial influence on vertical flux estimates using T-z methods. For low groundwater discharge fluxes (e.g., 0.1 m d -1 ), daily transience in streambed temperatures led to relatively large errors in estimated flow magnitude and direction. For higher discharge fluxes (1.5 m d -1 ), the influence of transient streambed temperatures on discharge estimates was strongly reduced. Discharge estimates from point-in-time T-z profiles were most accurate when the uppermost point in the T-z profile was near the bed interface daily mean (two time periods daily). Where temperature time series data are available, daily averaged T-z profiles can produce accurate discharge estimates across a wide range of discharge rates. Seasonality in shallow groundwater temperature generally had a negligible influence on vertical flow estimates. Finally, these findings can be used to plan field campaigns and provide guidance on the optimal application of T-z methods to quantify vertical groundwater discharge to surface water bodies.

54 ENVIRONMENTAL SCIENCES↗

Structural and magnetic depth profiles of magneto-ionic heterostructures beyond the interface limit

Electric field control of magnetism provides a promising route towards ultralow power information storage and sensor technologies. The effects of magneto-ionic motion have been prominently featured in the modification of interface characteristics. Here, we demonstrate magnetoelectric coupling moderated by voltage-driven oxygen migration beyond the interface in relatively thick AlO x /GdO x /Co(15 nm) films. Oxygen migration and Co magnetization are quantitatively mapped with polarized neutron reflectometry under electro-thermal conditioning. The depth-resolved profiles uniquely identify interfacial and bulk behaviours and a semi-reversible control of the magnetization. Magnetometry measurements suggest changes in the microstructure which disrupt long-range ferromagnetic ordering, resulting in an additional magnetically soft phase. X-ray spectroscopy confirms changes in the Co oxidation state, but not in the Gd, suggesting that the GdO x transmits oxygen but does not source or sink it. These results together provide crucial insight into controlling magnetism via magneto-ionic motion, both at interfaces and throughout the bulk of the films.

36 MATERIALS SCIENCE↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

Magnetic depth profile of a modulation doped La{sub 1-x}Ca{sub x}MnO{sub 3} exchange-biased system.

Recent magnetometry measurements in modulation-doped La{sub 1-x}Ca{sub x}MnO{sub 3} suggested that a net magnetization extends from the ferromagnetic layers into the adjacent antiferromagnet layers. Here we test this hypothesis by polarized neutron reflectometry, which allows us to determine the depth resolved magnetization profile. From fits to the reflectivity data we find that the additional magnetization does not occur at the ferromagnetic/antiferromagnetic interfaces, but rather in a thin region of the first antiferromagnetic layer adjacent to the interface with the substrate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The advancement of a technique using principal component analysis for the non-intrusive depth profiling of radioactive contamination

A non-intrusive technique using principal component analysis, to infer the depth of the fission fragment caesium-137, when it is buried under silica sand has been described. Using energy variances within different {gamma}-ray spectra, a complete depth model was produced for a single caesium-137 source buried under 1 mm depths ranging between 5-50 mm. This was achieved using a cadmium telluride detector and a bespoke phantom. In this paper we describe the advancement of the technique by further validating it using blind tests for applications outside of the laboratory, where not only the depth (z) but also the surface (x, y) location of {gamma}-ray emitting contamination is often poorly characterised. At present the technique has been tested at the point of maximum activity above the entrained {gamma}-ray emitting source (where the optimal x, y location is known). This is not usually practical in poorly characterized environments where the detector cannot be conveniently placed at such an optimal location to begin with and scanning at multiple points around the region of interest is often required. Using a uniform scanning time, the point of maximum intensity can be located by sampling in terms of total count rate, and converging on this optimal point of maximum intensity. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical depth profiling in thin SiON layers

The internal structure of SiON films is extracted electrically, demonstrating an efficient, noncontact, nondestructive means for depth compositional analysis in gate oxides. The electrical data, obtained using x-ray photoelectron spectroscopy (XPS) based controlled surface charging (CSC), are compared with independent time of flight secondary ion mass spectroscopy and angle resolved XPS data. Inhomogeneous composition with significant nitrogen enrichment at the top of the oxide layer is observed. Capabilities of the CSC method in treating heterostructures of poor chemical contrast are discussed.

36 MATERIALS SCIENCE↗

Ion microscopy with resonant ionization mass spectrometry : time-of-flight depth profiling with improved isotopic precision.

There are four generally mutually exclusive requirements that plague many mass spectrometric measurements of trace constituents: (1) the small size (limited by the depth probed) of many interesting materials requires high useful yields to simply detect some trace elements, (2) the low concentrations of interesting elements require efficient discrimination from isobaric interferences, (3) it is often necessary to measure the depth distribution of elements with high surface and low bulk contributions, and (4) many applications require precise isotopic analysis. Resonant ionization mass spectrometry has made dramatic progress in addressing these difficulties over the past five years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring the depth profiles of strain/composition in AlGaN-graded layer by high-resolution x-ray diffraction

Here, we demonstrate X-ray fitting through kinematical simulations of the intensity profiles of symmetric reflections for epitaxial compositionally graded layers of AlGaN grown by molecular beam epitaxy pseudomorphically on [0001]-oriented GaN substrates. These detailed simulations depict obvious differences between changes in thickness, maximum concentration, and concentration profile of the graded layers. Through comparison of these simulations with as-grown samples, we can reliably determine these parameters, most important of which are the profiles of the concentration and strain which determine much of the electrical properties of the film. In addition to learning about these parameters for the characterization of thin film properties, these fitting techniques create opportunities to calibrate growth rates and control composition profiles of AlGaN layers with a single growth rather than multiple growths as has been done traditionally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetometry and transport data complement polarized neutron reflectometry in magnetic depth profiling

Exchange coupled magnetic hard layer/soft layer thin films show a variety of complex magnetization reversal mechanisms depending on the hierarchy of interaction strengths within and between the films. Magnetization reversal can include uniform rotation, soft layer biasing, as well as exchange spring behavior. We investigate the magnetization reversal of a CoPt/Permalloy/Ta/Permalloy heterostructure. Here, Stoner-Wohlfarth-type uniform magnetization rotation of the virtually free Permalloy layer and exchange spring behavior of the strongly pinned Permalloy layer are found in the same sample. We investigate the complex magnetization reversal by polarized neutron reflectometry, magnetometry, and magneto-transport. The synergy of combining these experimental methods together with theoretical modeling is key to obtain the complete quantitative depth resolved information of the magnetization reversal processes for a multilayer of mesoscopic thickness.

36 MATERIALS SCIENCE↗

Compositional analysis and depth profiling of thin film CrO{sub 2} by heavy ion ERDA and standard RBS: a comparison

Chromium dioxide (CrO{sub 2}) thin film has generated considerable interest in applied research due to the wide variety of its technological applications. It has been extensively investigated in recent years, attracting the attention of researchers working on spintronic heterostructures and in the magnetic recording industry. However, its synthesis is usually a difficult task due to its metastable nature and various synthesis techniques are being investigated. In this work a polycrystalline thin film of CrO{sub 2} was prepared by electron beam vaporization of Cr{sub 2}O{sub 3} onto a Si substrate. The polycrystalline structure was confirmed through XRD analysis. The stoichiometry and elemental depth distribution of the deposited film were measured by ion beam nuclear analytical techniques heavy ion elastic recoil detection analysis (ERDA) and Rutherford backscattering spectrometry (RBS), which both have relative advantage over non-nuclear spectrometries in that they can readily provide quantitative information about the concentration and distribution of different atomic species in a layer. Moreover, the analysis carried out highlights the importance of complementary usage of the two techniques to obtain a more complete description of elemental content and depth distribution in thin films. - Graphical abstract: Heavy ion elastic recoil detection analysis (ERDA) and Rutherford backscattering spectrometry (RBS) both have relative advantage over non-nuclear spectrometries in that they can readily provide quantitative information about the concentration and distribution of different atomic species in a layer. Highlights: Black-Right-Pointing-Pointer Thin films of CrO{sub 2} have been grown by e-beam evaporation of Cr{sub 2}O{sub 3} target in vacuum. Black-Right-Pointing-Pointer The composition was determined by heavy ion-ERDA and RBS. Black-Right-Pointing-Pointer HI-ERDA and RBS provided information on the light and heavy elements, respectively.

36 MATERIALS SCIENCE↗

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x10{sup 14} ions cm{sup -2}. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm{sup -1} compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced {sup 12}C(d,p){sup 13}C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ion implanted silicon. Various implantations with N{sub 2}, O{sub 2}, NO, NO{sub 2} and Pb ions were performed with and without cooling of the liquid nitrogen trap. Simultaneous detection of ppm-level concentrations of {sup 12}C, {sup 16}O and {sup 14}N enables highly sensitive measurement of impurities that may be incorporated during the fabrication process, transport of the samples and/or storage of the samples in air.

36 MATERIALS SCIENCE↗

Depth profile of a time-reversal focus in an elastic solid

The out-of-plane velocity component is focused on the flat surface of an isotropic solid sample using the principle of time reversal. This experiment is often reproduced in the context of nondestructive testing for imaging features near the surface of the sample. However, it is not clear how deep the focus extends into the bulk of the sample and what its profile is. In this paper, this question is answered using both numerical simulations and experimental data. The profiles of the foci are expressed in terms of the wavelengths of the dominant waves, based on the interpretation of the Lamb’s problem and the use of the diffraction limit.

36 MATERIALS SCIENCE↗