Search NASA⌕ Search

SEARCH · Search NASA

Results for “design for X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments

We present DENNIS (Diffraction Experiment desigN and aNalysiS): a graphical software tool useful for the design and analysis of dynamic x-ray diffraction experiments, such as those performed on the Z Pulsed Power Facility, Thor Pulsed Power Generator, and Dynamic Compression Sector (DCS) of the Advanced Photon Source. DENNIS provides rapid powder and single-crystal diffraction pattern predictions and powder diffraction pattern image integration in three-dimensional geometries. Additional features include crystallographic information file reading, image processing, and synthetic diffraction pattern image generation. We overview the software's capabilities, detail the prediction and integration methodologies, and provide example implementations on Z and DCS experiments.

47 OTHER INSTRUMENTATION↗

Electrochemical exsolution of metal nanoparticles from perovskite oxide upon electrolysis

Here, this study presents a comprehensive investigation into the electrochemical reduction of LSCF perovskite during electrolysis, aiming to understand the exsolution of metal nanoparticles. The exsolution of metal nanoparticles from perovskite electrodes can significantly enhance their electrochemical performance in electrolysis. By applying cathodic polarization to the perovskite oxide electrode, the exsolution process was shown to be electrochemically induced within a few minutes. Additionally, a user-designed X-ray absorption spectroscopy operando cell was employed to analyze the edge energy change of the B-site atoms during electrolysis. The electrochemical reduction of perovskite and the subsequent exsolution of the B-site metal nanoparticles were investigated by scanning the cell voltage, providing an understanding of the electrochemical behavior during electrolysis. The electrochemical switching point, characterized by a decrease in the incremental area-specific resistance, was identified. This study offers valuable insights into the electrochemical exsolution process of metal nanoparticles from perovskite oxide electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEM/EBSD Characterization of Baffle-Former Bolts Designated for High Energy X-ray Microscopy Studies at the Advanced Photon Source

This report documents the microstructural and surface characterization of two high-fluence baffle-former bolts (BFBs) harvested from a commercial pressurized water reactor (PWR) after nearly four decades of service. These bolts experienced extreme conditions including high neutron fluence, elevated temperatures, corrosive primary water, and sustained mechanical loads, all of which contribute to degradation mechanisms such as irradiation-assisted stress corrosion cracking (IASCC). Using scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), the study assessed bulk and near-surface microstructures, grain boundary characteristics, and in-service oxide layers. The results revealed significant differences between bolts exposed to 41 dpa and 29 dpa, including differences in recrystallization extent, deformation structures, and oxidation morphology. These findings establish critical baseline data for integration with advanced synchrotron-based high-energy X-ray microscopy (HEXM) and computational crystal plasticity models. Ultimately, the work supports improved mechanistic understanding and predictive capability regarding the long-term performance of reactor core internal components.

Lach, Tim [Oak Ridge National Laboratory (ORNL), O↗

Design of an amplitude-splitting hard x-ray delay line with subnanoradian stability

We propose the design and analysis of a hard x-ray split-delay optical arrangement that combines diffractive and crystal optics. Transmission gratings are employed to achieve the much-desired amplitude splitting and recombination of the beam. Asymmetric channel-cut crystals are utilized to tune the relative delay time. The use of a dispersion-compensation arrangement of the crystals allows the system to achieve subnanoradian pointing stability during a delay scan. It further minimizes wavefront distortion and preserves the pulse front and pulse duration. We analyze the performance of a prototype design that can cover a delay time range of 15 ps with a sub-20 fs time resolution at 10 keV. We anticipate that this system can fully satisfy the very demanding stability requirements for performing split-pulse x-ray photon correlation spectroscopy measurements for the investigation of fast atomic scale dynamics in complex disordered matter.

47 OTHER INSTRUMENTATION↗

Design, fabrication, and testing of diamond axicons for X-ray microscopy applications

This work presents the design, fabrication, and experimental validation of a refractive diamond axicon for X-ray beam shaping. The diamond axicon was developed to overcome the limitations of polymer-based axicons particularly for application in Transmission X-ray Microscopy (TXM) systems, offering superior mechanical strength, thermal stability, and radiation resistance, making it ideal for synchrotron applications. The axicon was fabricated using femtosecond laser ablation and tested at 11 keV under various coherence conditions. Results demonstrated that the axicon efficiently transformed the X-ray beam into a ring-shaped profile with over 80% transmission. Simulations confirmed the experimental findings and highlighted the potential for further improvements. This work paves the way for the use of diamond axicons in next-generation synchrotron facilities, with future efforts focusing on optimizing fabrication and testing the axicon in full TXM systems.

Samadi, Nazanin↗

Designing Multiscale Porous Metal by Simple Dealloying with 3D Morphological Evolution Mechanism Revealed via X-ray Nano-tomography

Designing materials with multiscale, hierarchical structure is critical to drive the advancement of new technology. Specifically, porous metals with multiscale porosity from nanometer to micrometer sizes would lead to enhanced physical and chemical properties—the micron-sized pores can increase the effective diffusivity of ion transport within the porous media, and the nano-sized pores provide high specific surface area, enabling functionalities that are unique to nanoporous metals. A new ternary precursor alloy selection concept utilizing the different mixing enthalpies is demonstrated in this work for the design of multiscale, bimodal porous copper from a simple, one-step dealloying of Cu–Fe–Al ternary alloy. The nanoporosity in the bimodal porous structure is formed from dealloying of the Cu-rich phase, whereas the microporosity is controlled by dissolving the Fe-rich phase, determined by both the initial Fe particle size and sintering profile. In addition to advancing the materials design method, the multiscale pore formation during dealloying was directly visualized and quantified via an interrupted in situ synchrotron X-ray nano-tomography. The 3D morphological analysis on tortuosity showed that the presence of the microporosity can compensate the increase of the diffusion path length due to nanoporosity, which facilitates diffusion within the porous structure. Altogether the focus of the work is to introduce a new strategy to design multiscale porous metals with enhanced transport properties, and sheds light on the fundamental mechanisms on the 3D morphological evolution of the system using advanced synchrotron X-ray nano-tomography for future materials development and applications.

36 MATERIALS SCIENCE↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation furnace for synchrotron dark-field x-ray microscopy experiments

We present a multi-purpose radiation furnace designed for x-ray experiments at synchrotrons. The furnace is optimized specifically for dark-field x-ray microscopy (DFXM) of crystalline materials at beamline ID06 of the European Synchrotron Radiation Facility. The furnace can reach temperatures above 1200 °C with a thermal stability better than 10 °C, with heating and cooling rates up to 30 K/s. The non-contact heating design enables samples to be heated either in air or in a controlled atmosphere contained within a capillary tube. The temperature was calibrated via the thermal expansion of an α-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the radiation furnace. In the current configuration of the beamline, this furnace can be used for DFXM, near-field x-ray topography, bright-field x-ray nanotomography, high-resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure single crystal of aluminum.

Yildirim, C. (ORCID:0000000249690685)↗

Dispersion Caused by the Penetration Effect in X-ray Compressors

Chirped X-ray pulse compression is a promising approach for generating ultra-short X-ray free electron laser (XFEL) pulses. The design of X-ray pulse compressors requires the careful control of group delay dispersion (GDD), which plays a critical role in achieving optimal compression. However, the penetration dispersion of crystals and multilayers can induce an extra GDD, which may result in over-compression or under-compression. In this study, we investigate the penetration dispersion of crystals and multilayers theoretically and numerically. Our results indicate that the extra GDD induced by the penetration effect increases as the bandwidth of the rocking curve decreases. Moreover, the extra GDD is nonlinear and can be mitigated by optimizing the configuration of X-ray pulse compressors. This work provides insights into the dispersion compensation and configuration optimization of X-ray pulse compressors, which are essential for generating ultra-short XFEL pulses.

47 OTHER INSTRUMENTATION↗

Heavy ion beam probe for Wendelstein 7-X measurement capabilities as projected through its design

A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.

Instruments & Instrumentation↗

X-ray crystal structure of a designed rigidified imaging scaffold in the ligand-free conformation

Imaging scaffolds composed of designed protein cages fused to designed ankyrin repeat proteins (DARPins) have enabled the structure determination of small proteins by cryogenic electron microscopy (cryo-EM). One particularly well characterized scaffold type is a symmetric tetrahedral assembly composed of 24 subunits, 12 A and 12 B, which has three cargo-binding DARPins positioned on each vertex. Here, the X-ray crystal structure of a representative tetrahedral scaffold in the apo state is reported at 3.8 Å resolution. The X-ray crystal structure complements recent cryo-EM findings on a closely related scaffold, while also suggesting potential utility for crystallographic investigations. As observed in this crystal structure, one of the three DARPins, which serve as modular adaptors for binding diverse `cargo' proteins, present on each of the vertices is oriented towards a large solvent channel. The crystal lattice is unusually porous, suggesting that it may be possible to soak crystals of the scaffold with small (≤30 kDa) protein cargo ligands and subsequently determine cage–cargo structures via X-ray crystallography. The results suggest the possibility that cryo-EM scaffolds may be repurposed for structure determination by X-ray crystallography, thus extending the utility of electron-microscopy scaffold designs for alternative structural biology applications.

59 BASIC BIOLOGICAL SCIENCES↗

Our teams design high-resolution MeV x-ray radiography systems for National security missions [Poster]

The NNSS has been at the forefront of custom high-fidelity x-ray/gamma radiographic imaging solutions that serve our national security for over five decades. Our radiography team utilizes expertise in physics modeling and analysis, along with optical, mechanical, and electrical design, in close collaboration with our customers, to develop imaging methods and capabilities that go beyond their needs. Conceptual designs are developed through R&D efforts to provide solutions for the specific problem at hand. Field systems are designed and built in-house, then qualified utilizing a range of facilities across the National Security Enterprise. Radiographic imaging systems are deployed by our team in the most challenging environments. The NNSS has a strong math and programming team that provides novel on-site image analysis methods that extract crucial information from data returned in field tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of proton deflectometry with in situ x-ray fiducial for magnetized high-energy-density systems

We report a design and implementation of proton deflectometry with an in situ reference x-ray image of a mesh to precisely measure non-uniform magnetic fields in expanding plasmas at the OMEGA and OMEGA EP laser facilities. The technique has been developed with proton and x-ray sources generated from both directly driven capsule implosions and short pulse laser–solid interactions. The accuracy of the measurement depends on the contrast of both the proton and x-ray images. Here we present numerical and analytic studies to optimize the image contrast using a variety of mesh materials and grid spacings. Our results show clear enhancement of the image contrast by factors of four to six using a high Z mesh with large grid spacing. This leads to further improvement in the accuracy of the magnetic field measurement using this technique in comparison with its first demonstration at the OMEGA laser facility [Rev. Sci. Instrum. 93, 023502 (2022) [CrossRef]].

47 OTHER INSTRUMENTATION↗