Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting nanowire single-photon detector enhanced near-infrared II portable confocal microscopy for tissue imaging with indocyanine green

In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.

Liu, Yifan (ORCID:0000000328877704)↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a neutron multiplicity measurement with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26 ton Gadolinium (Gd)-loaded water Cherenkov detector located on the Booster Neutrino Beam line at Fermilab. Its main goals are the measurement of the neutron multiplicity in neutrino-nucleus interactions as well as the cross-section of Charged Current Quasi-Elastic (CCQE) neutrino interactions on water. Besides the physics goals, the experiment also aims to be a testbed for new technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillators (WbLS). This thesis presents a preliminary measurement of the neutron multiplicity with {ANNIE}, using an analysis conducted on a fraction of the 2021 beam year. As preparatory measures, the efficiency of ANNIE's Front Muon Veto (FMV) was determined to be {$\bar{\varepsilon}_{\mathrm{FMV}} = (95.6 \pm 1.6)\%$} while the average efficiency for active scintillator paddles in the Muon Range Detector (MRD) was found to be {$\bar{\varepsilon}_ {\mathrm{MRD}} = (92.1 \pm 7.9)\%$}. Furthermore, the simulation framework used for ANNIE was validated and adapted to reproduce the experimental data by comparing the detector response for samples of Michel electrons, Americium Beryllium neutrons, and through-going muons. The analysis finds average neutron yields of {$\bar{n}_{\mathrm{data}} (\mathrm{beam}) = (0.272 \pm 0.010_{\mathrm{stat}})$} for an inclusive set of all identified muon neutrino candidates and {$\bar{n}_{\mathrm{data}} (\mathrm{beam,FV}) = (0.287 \pm 0.044_{\mathrm{stat}})$ for interactions which happened inside of the Fiducial Volume of ANNIE, which was optimized to increase the neutron detection acceptance. The presented neutron multiplicity values represent the number of detected neutrons after all event selection cuts and are not yet corrected for the neutron detection efficiency. An equivalent analysis on a simulated beam sample predicts neutron yields of $\bar{n}_{\mathrm{MC}}(\mathrm{beam}) = (0.515 \pm 0.0 07_{\mathrm{stat}})$ and $\bar{n}_{\mathrm{MC}}(\mathrm{beam,FV}) = (0.627 \pm 0.031_{\mathrm{stat}})$, indicating that the models tend to overpredict the number of neutrons produced in such interactions. Systematic errors have been briefly considered to contribute {$\sigma_{\mathrm{sys,FMV}} \sim 0.01\,$neutrons/$\nu$-interaction} due to the slight FMV inefficiency and {$\sigma_{\mathrm{sys,n}} \sim 0.05\,$neutrons/$\nu$-interaction} due to the neutron detection efficiency. Simulation studies further highlighted the importance of neutron detection in Diffuse Supernova Background (DSNB) searches. A combination of neutron tagging and Convolutional Neural Networks was found to reduce the most relevant Neutral Current Quasi-Elastic (NCQE) interaction background below the signal level, achieving a Signal-to-Background ratio of 4:1. In a further study, we investigated the positive impact of a deployment of a WbLS target on the energy reconstruction in ANNIE. WbLS provides a scintillation signal from hadronic recoils in addition to the charged lepton that can be included in neutrino energy reconstruction. It was found that a deployed WbLS volume in ANNIE improves the neutrino energy reconstruction from 14\% to 12\%, with the potential of going beyond this if more sophisticated reconstruction algorithms are developed in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced antireflection for back-illuminated silicon photomultipliers to detect faint light

Silicon photomultipliers have attracted increasing attention for detecting low-density light in both scientific research and practical applications in recent years; yet the photon losses due to reflection on the light-sensitive planar silicon surface considerably limit its photon detection efficiency. Here we demonstrate an advanced light trapping feature by developing the multi-layer antireflection coatings and the textured silicon surface with upright random nano-micro pyramids, which significantly reduces the reflection of faint light in a wide spectrum, from ultraviolet to infrared. Integrating this advanced photon confinement feature into next-generation back-illuminated silicon photomultiplier would increase the photon detection efficiency with significantly lower reflection and much more active areas. This advanced design feature offers the back-illuminated silicon photomultiplier broader application opportunities exemplified in the emerging scenarios such as nuclear medical imaging, light detection and ranging for autonomous driving, detection of scintillation light in ionizing radiation, as well as high energy physics.

42 ENGINEERING↗

Boron Nitride Solid-State Neutron Detectors

The goal of this project is to build upon the work performed under the Texas Tech IDEAS project (DE-AR0000964 monitored by Dr. Isik Kizilyalli) to bring the developed B-10 enriched hexagonal boron nitride (h- 10 BN or 10 BN or BN) semiconductor neutron detector technology to the next level of maturity. In comparison to He-3 ( 3 He) gas detectors, BN neutron detectors possess all the intrinsic advantages of semiconductor devices: light weight, compact size, fast response speed, high spatial resolution, high temperature and low voltage operation capability, ease of mass production via existing semiconductor infrastructures, low cost of operation and maintenance, flexible form factors, and durability. The project will develop a prototype h- 10 BN neutron detector as a potential replacement for the 3 He gas neutron detectors (LND 25185 or equivalent) used in various neutron survey meters currently produced and commercialized by Ludlum Measurements, Inc. (LMI). To increase the overall detection efficiency, it is essential to maximize the collection efficiency of charge carriers (electrons and holes) generated by the nuclear reaction, which demands a further push to achieve 10 BN epilayers with improved material quality. The material growth processes will be guided by characterization of structural, optical, and electrical properties of h-BN. Selective devices will be calibrated at LMI. During ARPA-E supporting period, the key material parameters of h-BN produced by metal organic chemical vapor deposition (MOCVD), including the layer thickness, mobility-lifetime product, surface recombination field and detector size for maintaining a high charge collection efficiency all have been improved by several orders of magnitude. These improvements have enabled the realization of high-performance h 10BN semiconductor thermal neutron detectors. Presently, h- 10 BN thermal neutron detectors developed under ARPA-E’s support hold the record high detection efficiency among all solid-state detectors at 59%. With further development in manufacturing, there is no question that h-BN detectors will replace the traditional He-3 gas detectors in certain application areas by offering obvious advantages of semiconductor technologies over gas detectors and opportunities for users to dedicate the scarce and expensive supply of He-3 gas to other application areas where substitutes of He-3 gas are not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

First evaluation of fast neutron imaging with LiInSe 2 semiconductors

Fast neutron imaging is a powerful tool to investigate elemental/isotopic compositions of objects, supporting both scientific studies as well as cargo scanning. Current neutron imaging systems are faced with challenges associated with timing, detection efficiency, and/or spatial resolution. Here, we report on the use of a semiconducting lithium indium diselenide neutron sensor coupled to a Timepix ASIC for fast neutron imaging. Using a 15 cm thick copper knife edge, the spatial resolution of the neutron imager was found to be 1.55 mm for 9 MeV neutrons. In conclusion, the experimental detection efficiency at 9 MeV was in general agreement with calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton reconstruction with the TOTEM Roman pot detectors for high- β * LHC data

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β* data-taking period at $\sqrt({s})$ = 13 TeV in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method of creating structure for particle detection in time projection chambers and photodetectors

Time projection chambers are useful for high energy particle physics, nuclear physics, and astronomy. To enhance the particle detection efficiency and performance of the projection chambers functional bilayer thin film coatings based on the atomic layer deposition method are utilized. Coating material selection is based on Auger neutralization process ion induced electron emission from metallic surfaces (e.g., Mo or W) combined with a high secondary electron emission coefficient. Application of high secondary electron emission materials (e.g., MgO and CaF2) enhances the multiplication of these emitted electrons from ion induction processes. Therefore, using suitable bilayer coatings the overall TPC signal detection efficiency can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Characterization of Optically Smooth BREAD parts

The Broadband Reflector Experiment for Axion Detection is a dish antenna experiment probing the axion and dark photon parameter space in the [1 μeV, 1 eV] mass range, or [.02, 200] THz frequency range. In the pilot design for the InfraBREAD model, the dish antenna includes an optically smooth coaxial parabolic reflector to focus incoming photons in the near Infrared spectrum, created by the spontaneous photoconversion of axions and dark photons, onto a Superconducting Nanowire Single Photon Detector at the focus point of the reflector. As the pilot begins as a dark photon detector, sensitivity estimates hypothesize that it could cover unprobed parameter space in the search for the dark photon. Because of this, it is of critical importance that the reflector and SNSPD be placed at the correct points in the dish antenna, as previous work has shown that in addition to the focal spot of the photons being smeared to an area larger than the SNSPD, detection efficiency is s ensitive to shifts on the millimeter scale. In order to constrain this barrier to efficiency, the reflector had its focal spot, roughness, and length of surface waves measured by lasers in an optical bench setup. Results show the focal point diverging slightly from its theorized position in the antenna, while uncertainty in the height at which the detector should be placed was constrained to 10s of microns, the uncertainty in radial position could not be constrained to smaller than the detector given the methods used. Results for the roughness and surface wavelength show that the reflector was uniformly machined in a diamond-turning process used to fabricate optically smooth parts, as well as support a roughly 90% detection efficiency, reinforcing the sensitivity estimates presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Toward achieving cost-effective hexagonal BN semi-bulk crystals and BN neutron detectors via halide vapor phase epitaxy

Presently, thermal neutron detectors fabricated from boron-10 enriched hexagonal boron nitride (h-10BN) ultrawide bandgap semiconductor grown by metal organic chemical vapor deposition (MOCVD) hold the record high detection efficiency among all solid-state detectors at 59%. To overcome the short comings of MOCVD growth, including inherently low growth rate and unavoidable impurities such as carbon in metal organic source, we demonstrate here the growth of natural hexagonal boron nitride (h-BN) semi-bulk wafers using halide vapor phase epitaxy (HVPE), which is an established technique for producing GaN semi-bulk crystals at a high growth rate. Electrical transport characterization results revealed that these HVPE grown materials possess an electrical resistivity of 1 × 1013 Ω cm, and a charge carrier mobility and lifetime product of 2 × 10−4 cm2/V s. Detectors fabricated from a 100 μm thick h-BN wafer have demonstrated a thermal neutron detection efficiency of 20%, corresponding to a charge collection efficiency of ∼60% at an operating voltage of 500 V. This initial demonstration opens the door for mass producing high efficiency h-BN semiconductor neutron detectors at a reduced cost, which could create unprecedented applications in nuclear energy, national security, nuclear waste monitoring and management, the health care industry, and material sciences.

Physics↗

Probing and controlling oxygen impurity diffusion in h -BN semi-bulk crystals

Combining its unique features of ultrawide bandgap (UWBG) and two-dimensional nature, h-BN has been explored for emerging applications such as deep ultraviolet optoelectronic devices and single photon emitters. One of the unusual applications of h-BN is for solid-state neutron detectors by utilizing the property of high thermal neutron capture cross section of B-10 as well as its UWBG properties. Although a record high detection efficiency of 59% has been attained by h-BN detectors, the understanding/minimization of defects and impurities is still needed to further advance the h-BN material and detector technologies. We report metal organic chemical vapor deposition growth and oxygen (O) impurity diffusion in thick h-BN. The diffusion coefficient (D) of O impurities has been measured via the evolution of an oxygen related emission with the etching depth, providing a value of D of ∼ 2 × 10−13 cm2/s at 1450 °C and supporting the interpretation that oxygen in h-BN is a substitutional donor. A multiple-buffer-layer approach was employed to mitigate to a certain degree the issue of oxygen diffusion from sapphire substrate during growth. It was demonstrated that the performance of h-BN neutron detectors fabricated from the wafer incorporating multiple buffer layers was significantly improved, as manifested by the enhanced thermal neutron detection efficiency. The advancement of the crystal growth technology of h-BN semi-bulk crystals creates applications in optoelectronic and power electronic devices utilizing the UWBG semiconductor properties of h-BN, while high efficiency h-BN neutron detectors have the potential to supplant the traditional He-3 gas detectors in various application areas by offering the obvious advantages of UWBG semiconductor technologies.

Physics↗

DeepMerge – II. Building robust deep learning algorithms for merging galaxy identification across domains

In astronomy, neural networks are often trained on simulation data with the prospect of being used on telescope observations. Unfortunately, training a model on simulation data and then applying it to instrument data leads to a substantial and potentially even detrimental decrease in model accuracy on the new target dataset. Simulated and instrument data represent different data domains, and for an algorithm to work in both, domain-invariant learning is necessary. Here we employ domain adaptation techniques— Maximum Mean Discrepancy (MMD) as an additional transfer loss and Domain Adversarial Neural Networks (DANNs)— and demonstrate their viability to extract domain-invariant features within the astronomical context of classifying merging and non-merging galaxies. Additionally, we explore the use of Fisher loss and entropy minimization to enforce better in-domain class discriminability. We show that the addition of each domain adaptation technique improves the performance of a classifier when compared to conventional deep learning algorithms. We demonstrate this on two examples: between two Illustris-1 simulated datasets of distant merging galaxies, and between Illustris-1 simulated data of nearby merging galaxies and observed data from the Sloan Digital Sky Survey. The use of domain adaptation techniques in our experiments leads to an increase of target domain classification accuracy of up to ~20%. With further development, these techniques will allow astronomers to successfully implement neural network models trained on simulation data to efficiently detect and study astrophysical objects in current and future large-scale astronomical surveys.

galaxies: interactions↗