Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector array readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background(CMB)science depend on increasing the number of sensitive detectorsobserving the sky. New instruments deploy large arrays of superconducting transition-edge sensor(TES)bolometers tileddensely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers andsimplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexingfactor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, whichemploys microwave SQUID multiplexing(μmux). Simons Observatory will use 49 modules containing 70,000bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design,presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor.The median white noise of each readout channel is 65pA Hz. This impacts the projected SO mapping speed by<8%,which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. Wediscuss the measured performance in the context of SO science requirements, which are exceeded.

Heather McCarrick↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Ideal Integrating Bolometer

We describe a new 'ideal integrator' bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, Alan↗

Ideal Integrating Bolometer

We describe a new "ideal integrator" bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, A.↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a TES-Based Anti-Coincidence Detector for Future X-ray Observatories

Microcalorimeters onboard future x-ray observatories require an anti-coincidence detector to remove environmental backgrounds. In order to most effectively integrate this anticoincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We will present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine↗

Development of a TES-Based Anti-Coincidence Detector for Future X-Ray Observations

Microcalorimeters onboard future x-ray observatories require an anticoincidence detector to remove environmental backgrounds. In order to most effectively integrate this anti-coincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine N.↗

Novel multiplexing technique for detector and mixer arrays

Future space submillimeter telescopes will require large-format imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is combatible with large numbers of cryogenic detectors elements.

submillimeter↗

Development of 256 x 256 Element Impurity Band Conduction Infrared Detector Arrays for Astronomy

This report describes the work performed on a one and a half year advance technology program to develop Impurity Band Conduction (IBC) detectors with very low dark current, high quantum efficiency, and with good repeatable processes. The program fabricated several epitaxial growths of Si:As detecting layers from 15 to 35 microns thick and analyzed the performance versus the thickness and the Arsenic concentration of these epitaxial layers. Some of the epitaxial runs did not yield because of excessive residual impurities. The thicker epitaxial layers and the ones with higher Arsenic concentration resulted in good detectors with low dark currents and good quantum efficiency. The program hybridized six detector die from the best detector wafers to a low noise, 256 x 256 readout array and delivered the hybrids to NASA Ames for a more detailed study of the performance of the detectors.

Domingo, George↗

The Santa Barbara Research Center multimodule shortwave IR linear array and scene simulator

Alignment test results and scene simulator imagery are presented for a 1 x 1280 element linear assembly consisting of 5 end-butted modules. The modules include a Si readout chip, a 256 element photovoltaic HgCdTe detector array, and a Si/sapphire carrier. At 145 K, the operation of the LPE shortwave HgCdTE detector array yielded Resistance Area products of 420,000 ohm-sq cm. The results demonstrate the ability to fabricate high-performance, long linear multimodule shortwave IR focal planes for space applications.

Cizdziel, Philip↗

CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

X-ray↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗