Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Deviations from the Porter-Thomas Distribution due to Nonstatistical 𝛾 Decay below the 150 Nd Neutron Separation Threshold

We introduce a new method for the study of fluctuations of partial transition widths based on nuclear resonance fluorescence experiments with quasimonochromatic linearly polarized photon beams below particle separation thresholds. It is based on the average branching of decays of 𝐽=1 states of an even-even nucleus to the 2$^{+}_{1}$ state in comparison to the ground state. Between 5 and 7 MeV, a constant average branching ratio for 𝛾 decays from 1 − states of 0.490(16) is observed for the nuclide 150 Nd. Assuming 𝜒 2 -distributed partial transition widths, this average branching ratio is related to a degree of freedom of 𝜈 = 1.93⁢(12), rejecting the validity of the Porter-Thomas distribution, requiring 𝜈 = 1. The observed deviation can be explained by nonstatistical effects in the 𝛾-decay behavior with contributions in the range of 9.4(10)% up to 94(10)%.

150 ≤ A ≤ 189↗

Deviation from Debye-Waller behavior in single crystalline freestanding Ni⁢ O membranes studied via ultrafast electron diffraction

Here, we realize single-crystal freestanding Ni⁢O films on Si⁢N membranes, enabling thin-film scattering experiments with little or no substrate background signal. These membrane samples provide a critical platform for performing ultrafast electron diffraction (UED) to probe the response of the lattice to laser excitation. We show that epitaxial Ni⁢O films on a water-soluble Sr 2 ⁢Ca⁢Al 2⁢ O 6 buffer layer on Sr⁢Ti⁢O 3 substrates can be transferred as freestanding films to the Si⁢N membranes while maintaining the epitaxial character of the films. An above-gap photoexcitation (𝜆 =266 nm) incident on the sample stimulates an initial lattice response of the order of 1.1 ps, followed by the persistence of this state for more than 20 ps. We observe typical Debye-Waller behavior in peaks with 𝑞 above the (220) family, but a distinct deviation from this behavior is seen in low-𝑞 peaks. We relate this behavior to a dynamic decrease in sample mosaicity in response to the optical pump of the order of 3% that endures for approximately 4 ps. We suspect that this dynamic mosaicity is due to laser-induced strain propagation. This work demonstrates the viability of the thin-film transfer method for UED and paves the way for the study of the dynamic response of antiferromagnetic thin-film oxides.

Wisser, Jacob J. [Stanford Univ., CA (United State↗

Testing deviations from GR at cosmological scales including dynamical dark energy, massive neutrinos, functional or binned parametrizations, and spatial curvature

Here we introduce a new version of the Integrated Software in Testing General Relativity (ISiTGR) which is a patch to the software CAMB and CosmoMC . ISiTGR is intended to test deviations from GR at cosmological scales using cosmological datasets. While doing so, it allows for various extensions to the standard flat Λ cold dark matter model. In this new release, we have support for the following: (1) dynamical dark energy parametrizations with a constant or time-dependant equation of state; (2) a consistent implementation of anisotropic shear to model massive neutrinos throughout the full formalism; (3) multiple commonly used parametrizations of modified growth (MG) parameters; (4) functional, binned and hybrid time and scale dependencies for all MG parameters; (5) spatially flat or curved backgrounds. ISiTGR is designed to allow cosmological analyses to take full advantage of ongoing and future surveys to test simultaneously or separately various extensions to the standard model. We describe here the formalism and its implementation in the cosmic microwave background (CMB) code, the Integrated Sachs-Wolfe effect, and the 3 × 2 point statistics. Next, we apply ISiTGR to current datasets from Planck-2018, Planck-2015, Dark Energy Survey YR1 release, baryonic acoustic oscillations (BAO), redshift space distortions (BAO/RSD) from the BOSS Data Release 12, the 6DF Galaxy Survey and the SDSS Data Release 7 Main Galaxy Sample, and Supernova from the Pantheon compilation, joint SNLS/SDSS data analysis and the Hubble Space Telescope. We derive constraints on MG parameters for various combinations of the five features above and find that general relativity is consistent with current datasets in all cases.

79 ASTRONOMY AND ASTROPHYSICS↗

A Penalty Scheme for Mitigating Uninstructed Deviation of Generation Outputs From Variable Renewables in a Distribution Market

With rapid growth of distributed renewable generation, the establishment of electricity distribution markets has attracted widespread concerns. Different from existing transmission grid-scale electricity markets, an electricity distribution market is featured by numerous small-scale prosumers, and zero marginal cost and intermittency of renewable generation units. Against this background, this paper first extends an average pricing market (APM) mechanism for pricing renewable generation outputs with zero marginal cost in the distribution network concerned. Then, to mitigate the uninstructed volatility of renewable generation outputs and power demand, a penalty scheme is proposed for deviations between the real-time demand/output and market cleared bid/offer, with frequency regulation service (FRS) from energy storage systems (ESSs) considered. It is proved that the market volatility can be well controlled within an expected limit through properly setting the penalty prices for load demand and generation output fluctuations. Also, with this mechanism a non-negative market surplus could always be attained. Case studies are carried out to demonstrate the feasibility and efficiency of the proposed distribution market mechanism and penalty scheme.

electricity distribution market↗

SU-F-P-37: Implementation of An End-To-End QA Test of the Radiation Therapy Imaging, Planning and Delivery Process to Identify and Correct Possible Sources of Deviation

Purpose: To implement an end-to-end QA test of the radiation therapy imaging, planning and delivery process, aimed to assess the dosimetric agreement accuracy between planned and delivered treatment, in order to identify and correct possible sources of deviation. To establish an internal standard for machine commissioning acceptance. Methods: A test involving all steps of the radiation therapy: imaging, planning and delivery process was designed. The test includes analysis of point dose and planar dose distributions agreement between TPS calculated and measured dose. An ad hoc 16 cm diameter PMMA phantom was constructed with one central and four peripheral bores that can accommodate calibrated electron density inserts. Using Varian Eclipse 10.0 and Elekta XiO 4.50 planning systems, IMRT, RapidArc and 3DCRT with hard and dynamic wedges plans were planned on the phantom and tested. An Exradin A1SL chamber is used with a Keithley 35617EBS electrometer for point dose measurements in the phantom. 2D dose distributions were acquired using MapCheck and Varian aS1000 EPID.Gamma analysis was performed for evaluation of 2D dose distribution agreement using MapCheck software and Varian Portal Dosimetry Application.Varian high energy Clinacs Trilogy, 2100C/CD, 2000CR and low energy 6X/EX where tested.TPS-CT# vs. electron density table were checked for CT-scanners used. Results: Calculated point doses were accurate to 0.127% SD: 0.93%, 0.507% SD: 0.82%, 0.246% SD: 1.39% and 0.012% SD: 0.01% for LoX-3DCRT, HiX-3DCRT, IMRT and RapidArc plans respectively. Planar doses pass gamma 3% 3mm in all cases and 2% 2mm for VMAT plans. Conclusion: Implementation of a simple and reliable quality assurance tool was accomplished. The end-to-end proved efficient, showing excellent agreement between planned and delivered dose evidencing strong consistency of the whole process from imaging through planning to delivery. This test can be used as a first step in beam model acceptance for clinical use.

60 APPLIED LIFE SCIENCES↗

The physical mechanism of the deviation of cathode thermionic emission from the Schottky law

The deviation of the I–V characteristics of cathode materials in microwave devices from the Schottky law is caused by the occurrence of drift and diffusion of oxygen vacancies in barium-oxide crystallites, which are emission-active components of the cathode materials. The processing of experimental dependences using the proposed mathematical tools makes it possible to determine the barium-oxide-crystallite thickness and diffusivity of oxygen vacancies. The known diffusivity allows determining the presence of microimpurities in barium oxide, which affect its emission properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The NSLS-II Components Relative Alignment Deviation Estimate

The alignment of NSLS-II components will be conducted under the constraint of survey control network. The control network system is categorized as outside, primary and secondary control networks, and all of them have random errors due to measurement random errors. In the error propagation point of view, they all will contribute to the final positioning accuracy of each component in global sense. However, as the global positioning requirement is relative loose (i.e. ± 3mm for storage ring), relative positioning accuracy is what we really concern. In this situation, only secondary control network will contribute as only secondary monuments will be employed to direct the adjustment of components. Other error sources include instrument setup error, adjustment residuals and slab movement etc. This article will analyze the maximum relative deviation of 3 positions in one cell’s region, which is a simulation of 1 ID and 2 Vacuum chamber positions.

43 PARTICLE ACCELERATORS↗

Analytic Binary Alloy Volume–Concentration Relations and the Deviation from Zen’s Law

Alloys expand or contract as concentrations change, and the resulting relationship between atomic volume and alloy content is an important property of the solid. While a well-known approximation posits that the atomic volume varies linearly with concentration (Zen’s law), the actual variation is more complicated. Here we use the apparent size of the solute (solvent) atom and the elasticity to derive explicit analytical expressions for the atomic volume of binary solid alloys. Two approximations, continuum and terminal, are proposed. Deviations from Zen’s law are studied for 22 binary alloy systems.

36 MATERIALS SCIENCE↗

Hubble Parameter and Baryon Acoustic Oscillation Measurement Constraints on the Hubble Constant, the Deviation from the Spatially Flat ΛCDM Model, the Deceleration–Acceleration Transition Redshift, and Spatial Curvature

We construct a complete collection of reliable Hubble parameter H(z) data to redshift z ≤ 2.36 and use them with the Gaussian Process approach to determine continuous H(z) functions for various data subsets. From these continuous H(z)'s, summarizing across the data subsets considered, we find H 0 ~ 67 ± 4 km s–1 Mpc–1, more consistent with the recent lower values observed using a variety of techniques. In most data subsets, we see a cosmological deceleration–acceleration transition at 2σ significance, with the data subsets transition redshifts varying over $0.33\lt {z}_{\mathrm{da}}\lt 1.0$ at 1σ significance. We discover that the flat-ΛCDM model is consistent with the H(z) data to a z of 1.5 to 2.0, depending on data subset considered, with 2σ deviations from flat-ΛCDM above this redshift range. Using the continuous H(z) with baryon acoustic oscillation distance-redshift observations, we constrain the current spatial curvature density parameter to be ${{\rm{\Omega }}}_{K0}=-0.03\pm 0.21$, consistent with a flat universe, but the large error bar does not rule out small values of spatial curvature that are now under debate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deviations from maximal entanglement for eigenstates of the Sachdev-Ye-Kitaev model

We consider mid-spectrum eigenstates of the Sachdev-Ye-Kiteav (SYK) model. We prove that for subsystems whose size is a constant fraction of the system size, the entanglement entropy deviates from the maximum entropy by at least a positive constant. This result highlights the difference between the entanglement entropy of mid-spectrum eigenstates of the SYK model and that of random states.

Disordered Systems and Neural Networks (cond-mat.d↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On Large Deviations for Sums of i.i.d. Bernoulli Random Variables

Tail probabilities are studied for the binomial distribution. The Hoeffding inequality is sharpened in this particular case through estimating an integral factor in the Esscher transform, which is omitted in Hoeffding’s proof. This approach was already used by Talagrand (1995) in the general case. However, our results are much more precise. In particular, all involved constants are given in the explicit form.

97 MATHEMATICS AND COMPUTING↗

Radiation Oncology and Online Patient Education Materials: Deviating From NIH and AMA Recommendations

Purpose: Physicians encourage patients to be informed about their health care options, but much of the online health care–related resources can be beneficial only if patients are capable of comprehending it. This study's aim was to assess the readability level of online patient education resources for radiation oncology to conclude whether they meet the general public's health literacy needs as determined by the guidelines of the United States National Institutes of Health (NIH) and the American Medical Association (AMA). Methods: Radiation oncology–related internet-based patient education materials were downloaded from 5 major professional websites (American Society for Radiation Oncology, American Association of Physicists in Medicine, American Brachytherapy Society, (RadiologyInfo.org), and Radiation Therapy Oncology Group). Additional patient education documents were downloaded by searching for key radiation oncology phrases using Google. A total of 135 articles were downloaded and assessed for their readability level using 10 quantitative readability scales that are widely accepted in the medical literature. Results: When all 10 assessment tools for readability were taken into account, the 135 online patient education articles were written at an average grade level of 13.7 ± 2.0. One hundred nine of the 135 articles (80.7%) required a high school graduate's comprehension level (12th-grade level or higher). Only 1 of the 135 articles (0.74%) met the AMA and NIH recommendations for patient education resources to be written between the third-grade and seventh-grade levels. Conclusion: Radiation oncology websites have patient education material written at an educational level above the NIH and AMA recommendations; as a result, average American patients may not be able to fully understand them. Rewriting radiation oncology patient education resources would likely contribute to the patients' understanding of their health and treatment options, making each physician-patient interaction more productive and efficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Involved-Field Radiation Therapy Protocol Deviations in Pediatric Versus Adolescent and Young Adults With Hodgkin Lymphoma: A Report From the Children's Oncology Group AHOD0031

The presented protocol for pediatric intermediate-risk Hodgkin lymphoma evaluated the use of a dose-intensive chemotherapy regimen (ABVE-PC [doxorubicin, bleomycin, vincristine, etoposide, cyclophosphamide, prednisone]) with response-based therapy augmentation (addition of DECA [dexamethasone, etoposide, cisplatin, cytarabine]) or therapy reduction (elimination of radiation).

62 RADIOLOGY AND NUCLEAR MEDICINE↗