72 records · Page 4

Investigation at near-sonic speed of some effects of humidity on the longitudinal aerodynamic characteristics of an NASA supercritical wing research airplane model

The Langley 8-foot transonic pressure tunnel was used in an effort to determine the effects of humidity at near-sonic speed on the longitudinal aerodynamic characteristics and wing pressure distributions of an area-rule research airplane model with an NASA supercritical wing. Effects of dewpoint at the normal tunnel operating stagnation temperature of 48.9 C (120 F) and effects of stagnation temperature at a relatively high dewpoint of 15.6 C (60 F) were investigated. The test tunnel stagnation pressure was 101 325 N/sq m (1 atmosphere).

Jordan, F. L., Jr.↗

Hot-salt stress-corrosion of titanium alloys as related to turbine operation

In an effort to simulate typical compressor operating conditions of current turbine engines, special test facilities were designed. Air velocity, air pressure, air dewpoint, salt deposition temperature, salt concentration, and specimen surface condition were systematically controlled and their influence on hot-salt stress-corrosion evaluated. The influence of both continuous and cyclic stress-temperature exposures was determined. The relative susceptibility of a variety of titanium alloys in commonly used heat-treated conditions was determined. The effects of both environmental and material variables were used to interpret the behavior of titanium alloys under hot-salt stress-corrosion conditions found in jet engines and to appraise their future potential under such conditions.

Gray, H. R.↗

HCl in rocket exhaust clouds - Atmospheric dispersion, acid aerosol characteristics, and acid rain deposition

Both measurements and model calculations of the temporal dispersion of peak HCl (g + aq) concentration in Titan III exhaust clouds are found to be well characterized by one-term power-law decay expressions. The respective coefficients and decay exponents, however, are found to vary widely with meteorology. The HCl (g), HCl (g + aq), dewpoint, and temperature-pressure-altitude data for Titan III exhaust clouds are consistent with accurately calculated HCl/H2O vapor-liquid compositions for a model quasi-equilibrated flat surface aqueous aerosol. Some cloud evolution characteristics are also defined. Rapid and extensive condensation of aqueous acid clearly occurs during the first three min of cloud rise. Condensation is found to be intensified by the initial entrainment of relatively moist ambient air from lower levels, that is, from levels below eventual cloud stabilization. It is pointed out that if subsequent dilution air at stabilization altitude is significantly drier, a state of maximum condensation soon occurs, followed by an aerosol evaporation phase.

Pellett, G. L.↗

Structural analysis of stratocumulus convection

The 1 and 20 Hz data are examined from the Electra flights made on July 5, 1987. The flight legs consisted of seven horizontal turbulent legs at the inversion, midcloud, and below clouds, plus 4 soundings made within the same period. The Rosemont temperature sensor and the top and bottom dewpoint sensors were used to measure temperature and humidity at 1 Hz. Inversion structure and entrainment; local dynamics and large scale forcing; convective elements; and decoupling of cloud and subcloud are discussed in relationship to the results of the Electra flight.

Siems, S. T.↗

Carbon dioxide/dewpoint monitor

The portable Carbon Dioxide/Dewpoint Monitor was designed to permit measurements of carbon dioxide partial pressure and dewpoint and ambient gas temperature at any place within the Saturn Workshop. It required no vehicle interface other than storage. All components necessary for operation, including battery power source, were incorporated in the instrument.

Luczkowski, S.↗

Equations for the determination of humidity from dewpoint and psychrometric data

A general expression based on the Claperon-Clausius differential equation that relates saturation vapor pressure, absolute temperature, and the latent heat of transformation was derived that expresses saturation vapor pressure as a function of absolute temperature. This expression was then used to derive general expressions for vapor pressure, absolute humidity, and relative humidity as functions of either dewpoint and ambient temperature or psychrometric parameters. Constants for all general expressions were then evaluated to give specific expressions in both the international system of units and U.S. customary units for temperatures above and below freezing.

Parish, O. O.↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Relative susceptibility of titanium alloys to hot-salt stress-corrosion

Susceptibility of titanium alloys to hot-salt stress-corrosion cracking increased as follows: Ti-2Al-11Sn-5Zr-0.2Si(679), Ti-6Al-2Sn-4Zr-2Mo(6242), Ti-6Al-4V(64), Ti-6Al-4V-3Co(643), Ti-8Al-1Mo-1V(811), and Ti-13V-11Cr-3A1(13-11-3). The Ti-5Al-6Sn-2Zr-1Mo-0.25Si(5621S) alloy was both the least and most susceptible depending on heat treatment. Such rankings can be drastically altered by heat-to-heat and processing variations. Residual compressive stresses and cyclic exposures also reduce susceptibility to stress-corrosion. Simulated turbine-engine compressor environmental variables such as air velocity, pressure, dewpoint, salt concentration, and salt deposition temperature have only minor effects. Detection of substantial concentrations of hydrogen in all corroded alloys confirmed the existence of a hydrogen embrittlement mechanism.

Gray, H. R.↗

An assessment of VAS-derived retrievals and parameters used in thunderstorm forecasting

VAS satellite retrievals and derived parameters used in forecasting severe local storms were evaluated against corresponding radiosonde values. VAS products were also compared with the first-guess input to the retrieval algorithm. The evaluation methodology was to pair each radiosonde observation with the closest VAS retrieval within 50 km during a four-month period in 1986. VAS temperatures agreed closely with radiosonde values; dewpoints showed less agreement. Sounding differences were poorly correlated with the number of pixels from which the retrievals were prepared. VAS discrepancies usually were not well correlated with first-guess errors. Horizontal gradients of VAS products were stronger than those from radiosondes. VAS precipitable water agreed better with ground truth than did dewpoints at individual levels, but VAS thicknesses were not much improved. Results for severe storms forecasting parameters indicated that discrepancies increased with the amount of manipulation required during computation. The lifted index showed the best agreement; positive bouyant energy showed poor comparisons.

Fuelberg, Henry E.↗

High-Performance Miniature Hygrometer

Relatively inexpensive hygrometer that occupies volume less than 4 in.(3) measures dewpoints as much as 100 degrees C below ambient temperatures, with accuracy of 0.1 degrees C. Field tests indicate accuracy and repeatability identical to those of state-of-the-art larger dewpoint hygrometers. Operates up to 100 times as fast as older hygrometers, and offers simplicity and small size needed to meet cost and performance requirements of many applications.

Van Zandt, Thomas R.↗

An evaluation and comparison of vertical profile data from the VISSR Atmospheric Sounder (VAS)

A statistical evaluation is used to compared vertical profiles of temperature and moisture derived from VISSR Atmospheric Sounder (VAS) with three different algorithms to that of corresponding rawinsonde measurements for a clear cold environment. To account for time and space discrepancies between the data sets, rawinsonde data were adjusted to be representative of the satellite sounding times. Both rawinsonde and satellite sounding data were objectively analyzed onto a mesoscale grid. These grid point values were compared at 50 mb pressure increments from the surface up to 100 mb. The data were analyed for horizontal and vertical structure, representatives of derived parameters, and significant departure (improvement) from the apriori (first guess) information. Results indicate some rather strong temperature and moisture biases exist in the satellite soundings. Temperature biases of 1 to 4 C and dewpoint biases of 2 to 6 C generally occur in layers where strong inversions are present and vary with time as these atmospheric features evolve. The biases also changes as a function retrieval scheme suggesting limitations and restrictions on the applications of the various techniques. Standard temperature deviations range from 1 to 2 C for each retrieval scheme with maximum values around 800 and 400 mb. Derived parameters (precipitable water and thickness) suffer from similar biases, though to a somewhat lesser extent. Gradients of basic and derived parameters are generally weaker but have good horizontal structure where magnitudes of the parameters are relatively strong. Integrated thermal (temperature) and moisture (precipitable water) parameters show mixed results.

Jedlovec, G. J.↗

An evaluation and comparison of vertical profile data from the VISSR Atmospheric Sounder (VAS)

A statistical evaluation is used to compared vertical profiles of temperature and moisture derived from VISSR Atmospheric Sounder (VAS) with three different algorithms to that of corresponding rawinsonde measurements for a clear cold environment. To account for time and space discrepancies between the data sets, rawinsonde data were adjusted to be representative of the satellite sounding times. Both rawinsonde and satellite sounding data were objectively analyzed onto a mesoscale grid. These grid point values were compared at 50 mb pressure increments from the surface up to 100 mb. The data were analyzed for horizontal and vertical structure, representatives of derived parameters, and significant departure (improvement) from the apriori (first guess) information. Results indicate some rather strong temperature and moisture biases exist in the satellite soundings. Temperature biases of 1 to 4 C and dewpoint biases of 2 to 6 C generally occur in layers where strong inversions are present and vary with time as these atmospheric features evolve. The biases also changes as a function retrieval scheme suggesting limitations and restrictions on the applications of the various techniques. Standard temperature deviations range from 1 to 2 C for each retrieval scheme with maximum values around 800 and 400 mb. Derived parameters (precipitable water and thickness) suffer from similar biases, though to a somewhat lesser extent. Gradients of basic and derived parameters are generally weaker but have good horizontal structure where magnitudes of the parameters are relatively strong. Integrated thermal (temperature) and moisture (precipitable water) parameters show mixed results.

Jedlovec, G. J.↗

Quartz-crystal-oscillator hygrometer

Measuring device, which eliminates complex and expensive optical components by electronically sensing dewpoint of water vapor in gas, employs piezoelectric crystal oscillator, supportive circuitry, temperature regulators, and readout.

Kruger, R.↗

Investigation of some effects of humidity on aerodynamic characteristics on a 10-percent-thick NASA supercritical airfoil

An investigation was conducted in the Langley 8-foot transonic pressure tunnel to determine the effects of wind-tunnel humidity on the aerodynamic characteristics of a 10-percent-thick NASA supercritical airfoil. Effects of dewpoint variation from 267 K (20 F) to 294 K (70 F) were investigated. The tunnel stagnation temperature was 322 K (120 F) and the stagnation pressure was 0.1013 MN/09 m (1 atm).

Jordan, F. L., Jr.↗

A case study on the application of geosynchronous satellite infrared data to estimate soil moisture

The use of GOES IR temperature data to estimate soil moisture content is discussed and demonstrated, modifying the procedure proposed by Wetzel et al. (1984) to provide for incorporation of independent measurements of vegetation biomass, geostrophic wind speed, and surface dewpoint. Data acquisition, processing, and the statistical approach employed are described; data for Kansas and Nebraska during a six-day period in July 1978 are analyzed; and a statistical relationship between observed surface temperature and antecedent precipitation index is established. The results are presented in tables, graphs, and maps, and the regression procedure is found to predict antecedent precipitation with statistically significant precision.

Woodward, R. H.↗

Life of a Six-Hour Hurricane

Hurricane Claudette developed from a weak vortex in 6 h as deep convection shifted from downshear into the vortex center, despite ambient vertical wind shear exceeding 10 m/s. Six hours later it weakened to a tropical storm, and 12 h after the hurricane stage a circulation center could not be found at 850 hPa by aircraft reconnaissance. At hurricane strength the vortex contained classic structure seen in intensifying hurricanes, with the exception of 7-12 C dewpoint depressions in the lower troposphere upshear of the center. These extended from the 100-km radius to immediately adjacent to the eyewall, where equivalent potential temperature gradients reached 6 K/km. The dry air was not present prior to intensification, suggesting that it was associated with vertical shear-induced subsidence upshear of the developing storm. It is argued that weakening of the vortex was driven by cooling associated with the mixing of dry air into the core, and subsequent evaporation and cold downdrafts. Evidence suggests that this mixing might have been enhanced by eyewall instabilities after the period of rapid deepening. The existence of a fragile, small, but genuinely hurricane-strength vortex at the surface for 6 h presents difficult problems for forecasters. Such a "temporary hurricane" in strongly sheared flow might require a different warning protocol than longer-lasting hurricane vortices in weaker shear.

Shelton, Kay L.↗

Improved dewpoint-probe calibration

Relatively-simple pressure-control apparatus calibrates dewpoint probes considerably faster than conventional methods, with no loss of accuracy. Technique requires only pressure measurement at each calibration point and single absolute-humidity measurement at beginning of run. Several probes can be calibrated simultaneously and points can be checked above room temperature.

Stephenson, J. G.↗

Calibration and Data Retrieval Algorithms for the NASA Langley/Ames Diode Laser Hygrometer for the NASA Trace-P Mission

This paper describes the procedures and algorithms for the laboratory calibration and the field data retrieval of the NASA Langley / Ames Diode Laser Hygrometer as implemented during the NASA Trace-P mission during February to April 2000. The calibration is based on a NIST traceable dewpoint hygrometer using relatively high humidity and short pathlength. Two water lines of widely different strengths are used to increase the dynamic range of the instrument in the course of a flight. The laboratory results are incorporated into a numerical model of the second harmonic spectrum for each of the two spectral window regions using spectroscopic parameters from the HITRAN database and other sources, allowing water vapor retrieval at upper tropospheric and lower stratospheric temperatures and humidity levels. The data retrieval algorithm is simple, numerically stable, and accurate. A comparison with other water vapor instruments on board the NASA DC-8 and ER-2 aircraft is presented.

Podolske, James R.↗