Virtual Resonance and Frequency Difference Generation by van der Waals Interaction
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
MicroBooNE is a surface-level liquid argon time projection chamber neutrino detector taking data on the Booster Neutrino Beamline at Fermilab. By matching signals from an internal photomultiplier tube (PMT) system and an external cosmic ray tagger (CRT) in time, MicroBooNE can reject cosmic ray backgrounds. In order to achieve the best PMT flash - CRT hit time matching resolution, the relative time drift in the clock frequencies used by these two systems needs to be calibrated.
Lower hybrid current drive (LHCD) is one of the major approaches maintaining long pulse discharges on EAST. There are two lower hybrid (LH) systems on EAST launching waves at 4.6 GHz and 2.45 GHz into the plasma, respectively, and the input power of the 4.6 GHz wave is typically dominant. Here, the synergy of the two waves and the modification of the power deposition of the 4.6 GHz wave by coupling the 2.45 GHz wave are investigated theoretically. According to the phase space analysis, the wave propagation domains of the two LH waves always overlap substantially with each other for typical LHCD experimental parameters on EAST, indicating that the coupling between them might be strong. Ray-tracing/Fokker-Planck simulations for a LH current drive experiment on EAST show that the change of the power deposition profile due to the coupling could be understood by the rise and fall of the tails of the parallel electron distribution functions on different flux surfaces. If either the injected wave power at 2.45 GHz is comparable with that at 4.6 GHz or the incident N ∥ of the 2.45 GHz wave reaches a high value (e.g., $5.7/\sqrt{T_{e,0}}$), the power deposition profile of the 4.6 GHz wave can be modified greatly due to the coupling with the 2.45 GHz wave. With the parameters compatible with the ability of the LH wave system on EAST, injection of the 2.45 GHz wave can still modify the power deposition profile of the 4.6 GHz wave significantly by combining those two approaches. Finally, it is shown how a 4.6 GHz wave which cannot be Landau damped when injected alone is absorbed in low density plasmas with a magnetic shear reversal configuration in the presence of a 2.45 GHz wave.
Recent advancements in X-ray light sources enable element-sensitive nonlinear spectroscopies for probing molecular chirality. We simulate X-ray absorption spectroscopy, X-ray circular dichroism (XCD), and nonlinear optical/X-ray SFG and DFG (OX SFG/DFG) signals for two prototypical chiral molecules, fenchone and cysteine. Furthermore, our multireference simulations reproduce experimental data and reveal how novel X-ray spectroscopies exploit the site- and element-sensitivity of X-rays to uncover molecular asymmetry. The XCD spectra show strong asymmetries at chiral centers, while distant atoms contribute weaker signals. The OX SFG/DFG signals, under fixed resonant optical excitation, strongly depend on the core and valence excitations. This allows us to introduce two-dimensional (2D) chirality-sensitive valence-core spectroscopy, which provides insight into the overlap between valence orbitals and local molecular asymmetry. Finally, our estimates using realistic laser and X-ray pulse parameters demonstrate that such nonlinear experiments are feasible at XFELs, offering a promising tool for investigating chiral molecules.
We demonstrate dynamic recovery of blurred images caused by atmospheric turbulence. In particular, using a phase-conjugate wave generated by a second-order nonlinear crystal or composite, we restore the original quality of the image after the optical radiation forming the image propagates through the turbulent atmosphere. One of the key elements for our experiment is a rotating phase plate being placed in the beam path for simulating turbulent atmosphere. Using the nonlinear composite, we demonstrate that the image recovery is insensitive to the polarization of the optical radiation forming the image.
We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.
In magnetic confinement fusion, toroidicity-induced Alfvén eigenmodes (TAEs) are well-studied, weakly stable solutions of the linearized ideal magnetohydrodynamic equations. Driven unstable by suprathermal populations of energetic particles, TAE pose a key vulnerability to the confinement of high-energy alpha particles generated by fusion reactions. Hence, it is paramount to understand TAE dynamics if a working reactor is to be realized. In this work, we detect and characterize signatures of nonstationary nonlinear coupling between TAE using a novel, time-resolved bispectral analysis; results are supported by analytic signal of band-passed data. Crucially, a stationary phase relationship between two TAE and a nascent low frequency fluctuation is observed precisely when the triple product of magnetic fluctuation amplitudes is enhanced. Local mode number and frequency spectrum, gleaned from beam-emission spectroscopy, corroborates simultaneous satisfaction of nonlinear matching conditions, and provides a tool to identify theorized pathways of energy transfer, e.g. TAE parametric instability.
Explore the source record for details and available documents.
High-sensitivity detection of formaldehyde (CH2O) at 3.5315 micrometers (2831.64 cm-1) is reported with a diode-laser-pumped, fiber-coupled, periodically poled LiNbO3 spectroscopic source. This source replaced the Pb-salt diode laser Dewar assembly of an existing tunable diode-laser absorption spectrometer designed for ultrasensitive detection of CH2O. Spectra are recorded with 2f-modulation spectroscopy and zero-air rapid background subtraction. Initial measurements reported here, determined from multiple measurements of a flowing 7.7 parts per billion by volume (ppbv, parts in 10(9)) CH2O in air mixture, indicate replicate precisions as low as 0.24 ppbv.
This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.
Abstract not provided.
Methods have been developed to combine signals of various frequencies in a manner to produce clearer images in the presence of noise. Ground Penetrating Radar (GPR) scans at various frequencies are no exception. Methods using an optimization problem solver, the Expectation-Maximization (EM) Algorithm, define weights used to perform the task of combining GPR scans. In this paper, we explore using the Gaussian Mixture Model (GMM) feature of the EM Algorithm on GPR scans taken at various heights above ground ("Stand Off' GPR). This method demonstrates the same measured improvement toward producing a cleaner image as GPR scans taken at ground level using the same EM Algorithm method.
Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.
Explore the source record for details and available documents.