Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Evolution of the Deformation Substructure in a Ni-Co-Cr Equiatomic Solid Solution Alloy

The equiatomic NiCoCr alloy exhibits an excellent combination of strength and ductility, even greater than the FeNiCrCoMn high entropy alloy, and also displays a simultaneous increase in strength and ductility with decreasing the testing temperature. To systemically investigate the origin of the exceptional properties of NiCoCr alloy, which are related to the evolution of the deformation substructure with strain, interrupted tensile testing was conducted on the equiatomic NiCoCr single-phase solid solution alloy at both cryogenic and room temperatures at five different plastic strain levels of 1.5%, 6.5%, 29%, 50% and 70%. The evolution of deformation substructure was examined using electron backscatter diffraction (EBSD), transmission Kikuchi diffraction (TKD), conventional transmission electron microscopy (CTEM), diffraction contrast imaging using STEM (DCI-STEM) and atomic resolution scanning transmission electron microscopy. While the deformation substructure mainly consisted of planar dislocation slip and the dissociation of dislocations into stacking faults at small strain levels (≤6.5%), at larger strain levels, additional substructures including nanotwins and a new phase with hexagonal close packed (HCP) lamellae also appeared. The volume fraction of the HCP lamellae increases with increasing deformation, especially at cryogenic temperature. First principles calculations at 0 K indicate that the HCP phase is indeed energetically favorable relative to FCC for this composition. The effects of the nanotwin and HCP lamellar structures on hardening rate and ductility at both cryogenic and room temperature are qualitatively discussed.

Twinning↗

Optomechanical structure for a multifunctional hard x-ray nanoprobe instrument

A multifunctional hard x-ray nanoprobe instrument for characterization of nanoscale materials and devices includes a scanning probe mode with a full field transmission mode. The scanning probe mode provides fluorescence spectroscopy and diffraction contrast imaging. The full field transmission mode allows two-dimensional (2-D) imaging and tomography. The nanoprobe instrument includes zone plate optics for focusing and imaging. The nanoprobe instrument includes a stage group for positioning the zone plate optics. The nanoprobe instrument includes a specimen stage group for positioning the specimen. An enhanced laser Doppler displacement meter (LDDM) system provides two-dimensional differential displacement measurement in a range of nanometer resolution between the zone-plate optics and the sample holder. A digital signal processor (DSP) implements a real-time closed-loop feedback technique for providing differential vibration control between the zone-plate optics and the sample holder.

Shu, Deming↗

ADVANCED-STEM-BASED DEEP LEARNING FOR SEMANTIC SEGMENTATION OF DEFECTS IN STEELS

In this work, we developed a novel deep convolutional neural network (DCNN) model, called DefectNet, for robust and automated semantic segmentation of three crystallographic defects including line dislocations, precipitates and voids commonly observed in structural metals and alloys. In previous work, we established an experimental protocol for a diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) technique and tailored it specifically for imaging defects in popular iron-based structural alloy. Thus, the DefectNet was trained over a small but high-quality DCI STEM defect image sets of a HT-9 martensitic steel before and after neutron irradiation for 111.8 dpa at 412°C. For the defect quantification that typically takes at least half an hour even for an expert, with a good model the machine learning algorithm can produce more reproducible and reliable quantification in a few seconds. This work demonstrates the feasibility of using deep learning algorithms for fast and accurate defect quantitative analysis.

Machine Learning, Radiation effects, Image analysi↗

Simultaneous X-ray diffraction and phase-contrast imaging for investigating material deformation mechanisms during high-rate loading

Using a high-speed camera and an intensified charge-coupled device (ICCD), a simultaneous X-ray imaging and diffraction technique has been developed for studying dynamic material behaviors during high-rate tensile loading. A Kolsky tension bar has been used to pull samples at 1000 s -1 and 5000 s -1 strain-rates for super-elastic equiatomic NiTi and 1100-O series aluminium, respectively. By altering the ICCD gating time, temporal resolutions of 100 ps and 3.37 µs have been achieved in capturing the diffraction patterns of interest, thus equating to single-pulse and 22-pulse X-ray exposure. Furthermore, the sample through-thickness deformation process has been simultaneously imaged via phase-contrast imaging. It is also shown that adequate signal-to-noise ratios are achieved for the detected white-beam diffraction patterns, thereby allowing sufficient information to perform quantitative data analysis diffraction via in-house software ( WBXRD_GUI ). Of current interest is the ability to evaluate crystal d -spacing, texture evolution and material phase transitions, all of which will be established from experiments performed at the aforementioned elevated strain-rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial ({approx}2 {mu}m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonidentified Kikuchi lines with reverse contrast

Electron diffraction patterns of silicon in transmission with contrast reversal from bright to dark for an unidentified Kikuchi line along its length have been obtained. The contrast reversal of an unidentified line is explained within the elementary mechanism of Kikuchi pattern formation taking into account the Kikuchi electron double diffraction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring the Links between Structural Distortions, Orbital Ordering, and Multipolar Magnetic Ordering in Double Perovskites Containing Re(VI) and Os(VII)

A combination of high-resolution powder diffraction techniques and solid-state NMR has been employed to explore the links between crystal structure, orbital ordering, and magnetism in three isostructural double perovskites containing transition metal ions with a 5d 1 configuration. In Ba 2 ZnReO 6 , both neutron and synchrotron X-ray powder diffraction data reveal a cubic-to-tetragonal transition at 23 K that breaks the degeneracy of the t 2g orbitals and leads to a pattern of orbital ordering that stabilizes magnetic ordering when the sample is cooled below 16 K. Similar behavior is observed in Ba 2 MgReO 6 , with an orbital ordering temperature of 33 K and a magnetic ordering temperature of 18 K. Prior theoretical works suggest that the pattern of orbital order seen in the P42/mnm space group is needed to stabilize the heavily canted antiferromagnetism of these compounds. Unfortunately, powder diffraction data is not sensitive enough to differentiate between the I4/mmm and P42/mnm structural models, as the distortions are too subtle to be unambiguously identified from either neutron or synchrotron X-ray powder diffraction methods. In contrast, both diffraction and 7 Li NMR data indicate that Ba 2 LiOsO 6 retains the cubic structure down to 1.7 K. The antiferromagnetic ground state and lack of any sign of orbital ordering in Ba 2 LiOsO 6 provide compelling evidence that the electronically driven tetragonal distortion seen in Ba2ZnReO6, and Ba2MgReO6 is intimately linked to the magnetic ordering seen in those compounds. The absence of magnetic reflections in high intensity neutron powder diffraction data collected on Ba 2 MgReO 6 strongly suggests ordering of multipolar moments on Re(VI), likely ferro-octupolar ordering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image contrast of diffraction-limited telescopes for circular incoherent sources of uniform radiance

A simple approximate formula is derived for the background intensity beyond the edge of the image of uniform incoherent circular light source relative to the irradiance near the center of the image. The analysis applies to diffraction-limited telescopes with or without central beam obscuration due to a secondary mirror. Scattering off optical surfaces is neglected. The analysis is expected to be most applicable to spaceborne IR telescopes, for which diffraction can be the major source of off-axis response.

Shackleford, W. L.↗

Dislocation contrast on X-ray topographs under weak diffraction conditions

The contrast of dislocations in 4H-SiC crystals shows distinctive features on grazing-incidence X-ray topographs for diffraction at different positions on the operative rocking curve. Ray-tracing simulations have previously been successfully applied to describe the dislocation contrast at the peak of a rocking curve.The present work shows that the dislocation images observed under weak diffraction conditions can also be simulated using the ray-tracing method. Furthermore, these simulations indicate that the contrast of the dislocations is dominated by orientation contrast. Analysis of the effective misorientation reveals that the dislocation contrast in weak-beam topography is more sensitive to the local lattice distortion, consequently enabling information to be obtained on the dislocation sense which cannot be obtained from the peak.

36 MATERIALS SCIENCE↗

An assessment of the contributing factors to the superior properties of a nanostructured steel using in situ high-energy x-ray diffraction.

In contrast to most nanostructured materials, outstanding mechanical property has been demonstrated in a nanostructured metastable austenitic steel, owing to the new characteristics of deformation-induced martensitic transformation. In this paper, by employing an in situ high-energy X-ray diffraction technique, we explore these characteristics by examining factors from the load partitioning, Lueders banding, to texture development. It was found that the martensitic transformation was mainly driven through Lueders band propagation. Marked load transfer takes place from austenite to martensite as Lueders band propagates, and continues into the homogeneous deformation regime. The texture development is mostly contributed by martensitic transformation, but dislocation-based plasticity also plays a role. The effective load partitioning along with the deformability of martensite promotes sample ductility.

36 MATERIALS SCIENCE↗

Gain-phase grating based on spatial modulation of active Raman gain in cold atoms

In order to obtain an atomic grating which can diffract light into the high-order directions more efficiently, a gain-phase grating (GPG) based on the spatial modulation of active Raman gain is theoretically presented. This grating is induced by a pump field and a standing wave in ultracold atoms, and it not only diffracts a weak probe field propagating along a direction normal to the standing wave into the high-order directions, but also amplifies the amplitude of the zero-order diffraction. In contrast with electromagnetically induced grating or electromagnetically induced phase grating, the GPG has larger diffraction efficiencies in the high-order directions. Hence it is more suitable to be utilized as an all-optical router in optical networking and communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analyzer-based X-ray phase contrast imaging using the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut crystal

An analyzer-based X-ray phase contrast imaging experiment employing the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut analyzer crystal has been implemented and tested in a geometry similar to that used in conventional radiography. The high angular stability requirements were overcome using specially designed crystals and a closed-loop feedback intensity system, monitoring the intensity of the diffracted h-beam. Analyzer-based images (ABis) taken at different angular positions on the forward-diffracted o-beam rocking curve show different contrasts, as expected. However, the ABis did not show sharp borders. This was closely investigated by X-ray topography and Δ d / d mapping and was attributed to the stresses caused by the analyzer crystal's own weight in the bulk. Further investigation of the crystal design using finite element analysis coupled with dynamical theory of X-ray diffraction is envisaged.

Honnicke, Marcelo Goncalves (ORCID:000000033276432↗

Digital lock-in detection of site-specific magnetism in magnetic materials

The polarization and diffraction characteristics of x-rays incident upon a magnetic material are manipulated to provide a desired magnetic sensitivity in the material. The contrast in diffracted intensity of opposite helicities of circularly polarized x-rays is measured to permit separation of magnetic signals by element type and by atomic environment. This allows for the direct probing of magnetic signals from elements of the same species in nonequivalent atomic environments to better understand the behavior and characteristics of permanent magnetic materials. By using known crystallographic information together with manipulation of the polarization of x-rays having energies tuned near element-specific electronic excitations and by detecting and comparing the incident and diffracted photons at the same frequency, more accurate magnetic measurements can be made over shorter observation periods.

36 MATERIALS SCIENCE↗

Diffraction enhance x-ray imaging for quantitative phase contrast studies

Conventional X-ray imaging based on absorption contrast permits limited visibility of feature having small density and thickness variations. For imaging of weakly absorbing material or materials possessing similar densities, a novel phase contrast imaging techniques called diffraction enhanced imaging has been designed and developed at imaging beamline Indus-2 RRCAT Indore. The technique provides improved visibility of the interfaces and show high contrast in the image forsmall density or thickness gradients in the bulk. This paper presents basic principle, instrumentation and analysis methods for this technique. Initial results of quantitative phase retrieval carried out on various samples have also been presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, fabrication, and characterization of diffraction gratings for neutron phase contrast imaging

We have developed a neutron phase contrast imaging method based on a grating interferometer setup. The principal constituents are two absorption gratings made of gadolinium and a phase modulating grating made of silicon. The design parameters of the setup, such as periodicity, structure heights of the gratings, and the distances between the gratings, are calculated. The fabrication of each grating is described in detail. The produced diffraction gratings were finally characterized within the setup, by locally evaluating the produced contrast (visibility) in each detector pixel, resulting in a visibility map over the whole grating size. An averaged value of 23% is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH-CONTRAST STELLAR OBSERVATIONS WITHIN THE DIFFRACTION LIMIT AT THE PALOMAR HALE TELESCOPE

We report on high-accuracy high-resolution (<20 mas) stellar observations obtained with the Palomar Fiber Nuller (PFN), a near-infrared ({approx_equal}2.2 {mu}m) interferometric coronagraph installed at the Palomar Hale telescope. The PFN uses destructive interference between two elliptical (3 m Multiplication-Sign 1.5 m) sub-apertures of the primary to reach high dynamic range inside the diffraction limit of the full telescope. In order to validate the PFN's instrumental approach and its data reduction strategy, based on the newly developed 'Null Self-Calibration' (NSC) method, we observed a sample of eight well-characterized bright giants and supergiants. The quantity measured is the source astrophysical null depth, or equivalently the object's visibility at the PFN 3.2 m interferometric baseline. For the bare stars {alpha} Boo, {alpha} Her, {beta} And, and {alpha} Aur, PFN measurements are in excellent agreement with previous stellar photosphere measurements from long baseline interferometry. For the mass-losing stars {beta} Peg, {alpha} Ori, {rho} Per, and {chi} Cyg, circumstellar emission and/or asymmetries are detected. Overall, these early observations demonstrate the PFN's ability to measure astrophysical null depths below 10{sup -2} (limited by stellar diameters), with 1 {sigma} uncertainties as low as a few 10{sup -4}. Such visibility accuracy is unmatched at this spatial resolution in the near-infrared and translates into a contrast better than 10{sup -3} within the diffraction limit. With further improvements anticipated in 2011/2012, a state-of-the-art infrared science camera and a new extreme adaptive optics system, the PFN should provide a unique tool for the detection of hot debris disks and young self-luminous sub-stellar companions in the immediate vicinity of nearby stars.

79 ASTRONOMY AND ASTROPHYSICS↗