Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction in time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Line profile analysis of dislocation densities of the δ-phase 239 Pu-2.0 at%Ga alloy using neutron diffraction

Time-of-flight neutron diffraction measurements were conducted at ambient conditions to study microstructures of the δ-phase 239 Pu-2at% Ga alloy. Based on the line profile analysis of diffraction data we derived dislocation densities using a correction routine to account for the anisotropic strain broadening. Our results show here that the average dislocation density in the as-received sample, previously treated at cryogenic temperatures, is five times higher than the dislocation density measured after annealing the sample, indicating that the neutron instrumentation used in this work has sufficient resolution to detect the dislocation density changes in different sample processing. These results are also in reasonably good agreement with the dislocation densities previously reported based on TEM observations and x-ray diffraction data, suggesting that the simple correction routines applied in this work have a fairly good fidelity for deriving important microstructural information such as dislocation density for elastically highly anisotropic δ-phase 239 Pu-Ga alloys.

36 MATERIALS SCIENCE↗

In-situ Time-Resolved Neutron Diffraction Measurements of Microstructure Variations during Friction Stir Welding in a 6061-T6 Aluminum Alloy

The microstructure change is one of the most important research areas in the friction stir welding (FSW). However, direct observation of microstructure changes during FSW has been extremely challenging because many measurement techniques are inapplicable. Recently developed in-situ time-resolved neutron diffraction methodology, which drastically improves the temporal resolution of neutron diffraction, enables to observe the transient microstructure changes during FSW. We installed a portable FSW system in the Spectrometer for MAterials Research at Temperature and Stress (SMARTS) at Los Alamos Neutron Science Center and the FSW was made on 6.35mm-thickness 6061-T6 Al alloy plate. At the same time, the neutron beam was centered on the mid-plane of the Al plate at 8 mm from the tool center (underneath the tool shoulder) and the diffraction peak was continuously measured during welding. The peak broadening analysis has been performed using the Williamson-Hall Method. The result shows that the dislocation density of about 3.2 x 10^15 m-2 duing FSW, which is the significant increse compared to the before (4.5 x 10^14 m-2) and after (4.0 x 10^14 m-2) the FSW. The quantitatively analysis of the grain structure can provide an insight to understand the transient variation of the microstructure during FSW.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying Dynamic Signal Spread in Real-Time High-Energy X-ray Diffraction

Abstract Measured intensity in high-energy monochromatic X-ray diffraction (HEXD) experiments provides information regarding the microstructure of the crystalline material under study. The location of intensity on an areal detector is determined by the lattice spacing and orientation of crystals so that changes in the heterogeneity of these quantities are reflected in the spreading of diffraction peaks over time. High temporal resolution of such dynamics can now be experimentally observed using technologies such as the mixed-mode pixel array detector (MM-PAD) which facilitates in situ dynamic HEXD experiments to study plasticity and its underlying mechanisms. In this paper, we define and demonstrate a feature computed directly from such diffraction time series data quantifying signal spread in a manner that is correlated with plastic deformation of the sample. A distinguishing characteristic of the analysis is the capability to describe the evolution from the distinct diffraction peaks of an undeformed alloy sample through to the non-uniform Debye–Scherrer rings developed upon significant plastic deformation. We build on our previous work modeling data using an overcomplete dictionary by treating temporal measurements jointly to improve signal spread recovery. We demonstrate our approach in simulations and on experimental HEXD measurements captured using the MM-PAD. Our method for characterizing the temporal evolution of signal spread is shown to provide an informative means of data analysis that adds to the capabilities of existing methods. Our work draws on ideas from convolutional sparse coding and requires solving a coupled convex optimization problem based on the alternating direction method of multipliers.

Engineering↗

Shedding Light on the Photochemistry of Coinage-Metal Phosphorescent Materials: A Time-Resolved Laue Diffraction Study of an Ag I -Cu I Tetranuclear Complex

The triplet excited state of a new crystalline form of a tetranuclear coordination d 10 –d 10 -type complex, Ag 2 Cu 2 L 4 (L = 2-diphenylphosphino-3-methylindole ligand), containing Ag I and Cu I metal centers has been explored using the Laue pump–probe technique with ≈80 ps time resolution. The relatively short lifetime of 1 μs is accompanied by significant photoinduced structural changes, as large as the Ag1···Cu2 distance shortening by 0.59(3) Å. The results show a pronounced strengthening of the argentophilic interactions and formation of new Ag···Cu bonds on excitation. Theoretical calculations indicate that the structural changes are due to a ligand-to-metal charge transfer (LMCT) strengthening the Ag···Ag interaction, mainly occurring from the methylindole ligands to the silver metal centers. QM/MM optimizations of the ground and excited states of the complex support the experimental results. Comparison with isolated molecule optimizations demonstrates the restricting effect of the crystalline matrix on photoinduced distortions. The work represents the first time-resolved Laue diffraction study of a heteronuclear coordination complex and provides new information on the nature of photoresponse of coinage metal complexes, which have been the subject of extensive studies.

Jarzembska, Katarzyna N.↗

Diffraction at a time grating in above-threshold ionization: The influence of the Coulomb potential

We analyze the photoelectron emission spectrum in atomic above-threshold ionization by a linearly polarized short-laser pulse. Direct electrons can be characterized by both intracycle and intercycle interferences. The former results from the coherent superposition of two different electron trajectories released in the same optical cycle, whereas the latter is the consequence of the superposition of multiple trajectories released in different cycles. In the present article, a semiclassical analytical expression for the complete (both intracycle and intercycle) interference pattern is derived. We show that the recently proposed semiclassical description in terms of a diffraction process at a time grating remains qualitatively unchanged in the presence of the long-range Coulomb potential. The latter causes only a phase shift of the intracycle interference pattern. We verify the predictions of the semiclassical model by comparison with full three-dimensional (3D) time-dependent Schroedinger equation (TDSE) solutions. One key finding is that the subcycle interference structures originating from trajectories launched within a time interval of less than 1 femtosecond should be experimentally observable also in low-resolution spectra for longer multicycle pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION↗

Multi-scale time-resolved electron diffraction: A case study in moiré materials

Ultrafast-optical-pump — structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. Here we deploy a hybrid pixel array direct electron detector to perform ultrafast electron diffraction experiments on a WSe 2 /MoSe 2 2D heterobilayer, resolving the weak features of diffuse scattering and moiré superlattice structure without saturating the zero order peak. Enabled by the detector’s high frame rate, we show that a chopping technique provides diffraction difference images with signal-to-noise at the shot noise limit. Finally, we demonstrate that a fast detector frame rate coupled with a high repetition rate probe can provide continuous time resolution from femtoseconds to seconds, enabling us to perform a scanning ultrafast electron diffraction experiment that maps thermal transport in WSe 2 /MoSe 2 and resolves distinct diffusion mechanisms in space and time.

36 MATERIALS SCIENCE↗

Time-Resolved Electron Diffraction from Selectively Aligned Molecules

We experimentally demonstrate ultrafast electron diffraction from transiently aligned molecules in the absence of external (aligning) fields. A sample of aligned molecules is generated through photodissociation with femtosecond laser pulses, and the diffraction pattern is captured by probing the sample with picosecond electron pulses shortly after dissociation - before molecular rotation causes the alignment to vanish. In our experiments the alignment decays with a time constant of 2.6{+-}1.2 ps.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Quantitative Analysis of Room Temperature Recrystallization Kinetics in Electroplated Copper Films using High Resolution X-ray Diffraction

Time-resolved in situ x-ray diffraction measurements were used to study the room-temperature recrystallization kinetics of electroplated copper thin films with thicknesses between 400 and 1000 nm. The thinnest films exhibited limited recrystallization and subsequent growth of grains, while recrystallized grains in the thicker films grew until all as-plated microstructure was consumed. For all films, recrystallized grains that belonged to the majority texture component, <111>, started growing after the shortest incubation time. These grains exhibited volumetric growth until they achieved the film thickness. After this point the growth mode became planar, with the <111>-type grains growing in the plane of the film. Grains with the <111> direction normal to the film surface started growing after the <111>-type grains switched to planar growth. However, the planar growth of this texture component finished at the same time as the growth of the <111> grains. Profile fitting of the 111 peak permitted the separation of the diffraction signals from recrystallized and as-plated grain populations. The average strains in these two populations, calculated from the peak position of the corresponding {l_brace}111{r_brace} reflections, were different, indicating a heterogeneous stress state within this texture component. The increasing volume fraction of recrystallized <111> grains with time was monitored via the variation in the diffracted intensity. This variation could be represented by the Johnson-Mehl-Avrami-Kolmogorov model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing the Effects of Etch-induced Material Modification on the Crystallization Properties of Nitron Doped Ge2Sb2Te5

The chemical and structural effects of processing on the crystallization of nitrogen doped Ge{sub 2}Sb{sub 2}Te{sub 5} is examined via x-ray photoelectron spectroscopy (XPS), x-ray absorption spectroscopy (XAS), time resolved laser reflectivity, and time resolved x-ray diffraction (XRD). Time resolved laser reflectivity and XRD show that exposure to various etch and ash chemistries significantly reduces the crystallization speed while the transition temperature from the rocksalt to the hexagonal phase is increased. XPS and XAS attribute this to the selective removal and oxidization of N, Ge, Sb, and Te, thus altering the local bonding environment to the detriment of device performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary time-of-flight neutron diffraction study of human deoxyhemoglobin

In order to investigate the role of the protonation states of protein residues in O{sub 2} binding, large crystals of deoxy HbA (∼20 mm{sup 3}) were grown in D{sub 2}O under anaerobic conditions for neutron diffraction studies. Human hemoglobin (HbA) is an intricate system that has evolved to efficiently transport oxygen molecules (O{sub 2}) from lung to tissue. Its quaternary structure can fluctuate between two conformations, T (tense or deoxy) and R (relaxed or oxy), which have low and high affinity for O{sub 2}, respectively. The binding of O{sub 2} to the heme sites of HbA is regulated by protons and by inorganic anions. In order to investigate the role of the protonation states of protein residues in O{sub 2} binding, large crystals of deoxy HbA (∼20 mm{sup 3}) were grown in D{sub 2}O under anaerobic conditions for neutron diffraction studies. A time-of-flight neutron data set was collected to 1.8 Å resolution on the Protein Crystallography Station (PCS) at the spallation source run by Los Alamos Neutron Science Center (LANSCE). The HbA tetramer (64.6 kDa; 574 residues excluding the four heme groups) occupies the largest asymmetric unit (space group P2{sub 1}) from which a high-resolution neutron data set has been collected to date.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast structural dynamics of UV photoexcited cis , cis -1,3-cyclooctadiene observed with time-resolved electron diffraction

Conjugated diene molecules are highly reactive upon photoexcitation and can relax through multiple reaction channels that depend on the position of the double bonds and the degree of molecular rigidity. Understanding the photoinduced dynamics of these molecules is crucial for establishing general rules governing the relaxation and product formation. Here, in this study, we investigate the femtosecond time-resolved photoinduced excited-state structural dynamics of cis,cis-1,3-cyclooctadiene, a large-flexible cyclic conjugated diene molecule, upon excitation with 200 nm using mega-electron-volt ultrafast electron diffraction and trajectory surface hopping dynamics simulations. We tracked the photoinduced structural changes from the Franck–Condon region through the conical intersection seam to the ground state. Our findings revealed a novel primary reaction coordinate involving ring distortion, where the ring stretches along one axis and compresses along the perpendicular axis. The nuclear wavepacket remains compact along this reaction coordinate until it reaches the conical intersection seam, and it rapidly spreads as it approaches the ground state, where multiple products are formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating High Field Phases of the Multiferroic MnWO4 with a Pulsed Magnetic Field and Time of Flight Neutron Laue Diffraction

We have combined time-of-flight neutron Laue diffraction and pulsed high magnetic fields at the Spallation Neutron Source to study the phase diagram of the multiferroic material MnWO4. The control of the field-pulse timing enabled an exploration of magnetic Bragg scattering through the time dependence of both the neutron wavelength and the pulsed magnetic field. This allowed us to observe several magnetic Bragg peaks in different field-induced phases of MnWO4 with a single instrument configuration. These phases were not previously amenable to neutron diffraction studies due to the large fields involved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct observations of shock-induced melting in a porous solid using time-resolved x-ray diffraction

Here in this work we provide direct evidence of shock-induced melting and associated kinetics in a porous solid (aluminum powder) using time-resolved x-ray diffraction. Unambiguous evidence of melting in 50% porous aluminum (Al) powder samples, shocked to peak pressures between ~13 - 19 GPa, was provided by the broadening of the Debye-Scherrer ring corresponding to the (111) peak. Shocked Al powder did not melt completely in any of our experiments within the durations of measurement. Incomplete (partial) melting of the powder, even after several hundreds of nanoseconds of shock loading, provides insights into thermal transport with Al powder particles under high-pressure dynamic loading. Such insights are quite valuable for developing well-constrained melting models and thermodynamic equations of state for porous Al and other porous solids relevant to planetary and materials science.

36 MATERIALS SCIENCE↗