Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reciprocal Space Mapping of Macromolecular Crystals in the Laboratory

The technique of reciprocal space mapping applied to the physical measurement of macromolecular crystals will be described. This technique uses a triple axis diffractometer setup whereby the monochromator is the first crystal, the sample is the second and the third crystal (of the same material as the monochromator) analyzes the diffracted beam. The geometry is such that it is possible to separate mosaic volume effects from lattice strain effects. The deconvolution of the instrument parameters will also be addressed. Results from measurements at Brookhaven National Synchrotron Radiation Source carried out on microgravity and ground-grown crystals will be presented. The required beam characteristics for reciprocal space mapping are also ideal for topographic studies and the first topographs ever recorded from microgravity protein crystal samples will be shown. We are now working on a system which will enable reciprocal space mapping, mosaicity and topography studies to be carried out in the home laboratory. This system uses a rotating anode X-ray source to provide an intense beam then a Bartels double crystal, four reflection monochromator to provide the spectral and geometric beam conditioning necessary such that the instrument characteristics do not mask the measurement. This is coupled to a high precision diffractometer and sensitive detector. Commissioning data and first results from the system will be presented.

Snell, Edward H.↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-pressure flow through test vessel for neutron imaging and neutron diffraction-based strain measurement of geological materials

Neutron scattering and neutron imaging have emerged as powerful methods for experimentally investigating material deformation and fluid flow in the interior of otherwise inaccessible or opaque structures. This paper describes the design and provides example uses of a pressure cell developed for investigating such behaviors within geological materials. The cell can accommodate cylindrical samples with diameters up to 38.1 mm and lengths up to 154 mm. Additionally, ports in the cell and a pressure isolating sleeve around the sample allow the independent application of confining pressure up to 69 MPa and axial pressure up to 34.5 MPa. Furthermore, two material versions of the cell have been manufactured and used to date. An aluminum version is typically used for temperatures below 40 °C, because of its relative transparency to neutrons, while a titanium version, which is comparatively more neutron attenuating, is used for experiments requiring triaxial pressurization under conditions up to 350 °C. The pressure cells were commissioned at the VULCAN engineering diffractometer at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source, and have since been used at the ORNL high flux isotope reactor CG1-D imaging beamline, National Institute of Standard and Technology (NIST) BT-2, and NIST NG6 imaging beamlines.

47 OTHER INSTRUMENTATION↗

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Easy‐to‐Use Custom‐Built Cell for Neutron Powder Diffraction Studies of Rechargeable Batteries

Abstract In operando powder diffraction remains one of the most powerful tools for non‐destructive investigation of battery electrode materials. While in operando X‐ray, especially synchrotron radiation, powder diffraction is by now a routine experimental technique, in operando neutron powder diffraction is still less established. We present a new electrochemical cell for in operando neutron powder diffraction, which is, first and foremost, easy to use, but can also cycle electrode materials under electrochemical conditions close to those achieved using standard laboratory cells. The cell has been designed in multiple sizes, and high‐quality electrochemical and neutron powder diffraction data is presented for sample sizes as low as 48 mg total active material. The cell handles lithium‐ion and sodium‐ion materials equally well, with no difference in how the cell is prepared and assembled. The cell is intended to be used as sample environment at powder diffractometers at the neutron facilities MLZ, ORNL and ACNS.

25 ENERGY STORAGE↗

Simulation of the Impact of Point Defects and Edge Dislocations on X-Ray Diffraction in Hexagonal (Ni,Co) 1+2 x Ti 1– x O 3 Thin Films

In this work, a computer code for simulating high-resolution X-ray diffraction (XRD) data from disordered crystals with arbitrary spatial composition and local lattice parameters is developed. Simulated patterns are compared with the experimental data collected on a single phase, highly crystalline (Ni 0.42 Co 0.58 ) 2.22 Ti 0.39 O 3 solid-solution thin film exhibiting a large number of subsidiary minima. As a case study, the edge dislocations in hexagonal (Ni,Co) 3 O 3 thin films with Burgers vector parallel and perpendicular to the a-axis and c-axis, respectively, are modeled. No peak profiles are assumed and thus issues related to profile fitting are avoided. Both macroscopic features, such as film thickness, and atomic-scale structure, such as dislocations, are simultaneously modeled. Simulations are run on a desktop machine. Commonly applied database-based phase identification routines can result in wrong phase identification, unless intensities are properly modeled. Modeling tools of diffractometer manufacturers are compared with the present approach. An example of how simulated reciprocal lattice patterns can be used to choose relevant measurement geometries in defected thin films is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Functional group effect of chemically modified microcrystalline methyl cellulose on thermoplastic polyurethane composites

Microcrystalline cellulose (MCC) is a promising bio-based filler for lightweight yet mechanically high-performance eco-polymer composites because of its low density and high biocompatibility. However, intermolecular hydrogen bonding among MCC is stronger than the polymer–filler interactions, which deteriorate the mechanical properties of the composites. Herein, we investigated the effects of functional groups on the mechanical properties of composites by scrutinizing chemically modified microcrystalline methyl cellulose (m-MMC) with three different substitution levels of hydroxyl group to hydroxypropyl (HP) group: no-, low-, and high-level substitution (HP-0, HP-low, and HP-high). The degree of HP substitution of m-MMC was quantitatively measured by CP/MAS NMR analysis. The relatively bulky HP groups interrupted the filler–filler intermolecular interactions and reduced the crystallinity and density of m-MMC, as evident from X-ray diffractometer and pycnometer data, respectively. For scalable production of the composites, the m-MMC were compounded with thermoplastic polyurethane (TPU) by a twin-screw extruder at concentrations between 0.5 and 10 wt%. Despite its low filler concentration, the toughness of m-MMC/TPU composites was remarkably enhanced, up to 28% (229.2 to 294.4 MJ/m 3 ) at 0.5 wt% loading of HP-low, owing to the enhanced polymer–filler interactions. In conclusion, the fundamental understanding on structure–property relationships will provide insights for designing of mechanically robust yet eco-friendly polymer composites.

composites↗

IMAGINE: The neutron protein crystallography beamline at the high flux isotope reactor

IMAGINE is a high intensity, quasi-Laue neutron crystallography beamline developed at the 85 MW High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This state-of-the-art facility for neutron-diffraction enables neutron protein structures to be determined at or near atomic resolutions from crystals with volumes of < 1 mm 3 and unit cell edges of < 150 Å. The beamline features include elliptical focusing mirrors that deliver neutrons into a 2.0 × 3.2 mm 2 focal spot at the sample position, and variable short and long wavelength cutoff optics that provide automated exchange between multiple wavelength configurations. The beamline is equipped with a single-axis goniometer, neutron-sensitive cylindrical image plate detector and room temperature and cryogenic sample environments. This article describes the beamline components, the diffractometer and the data collection and data analysis protocols that are used, and outlines the protein deuteration, crystallization and conventional crystallography capabilities that are available to users at ORNL's neutron facilities. We also present examples of the scientific questions being addressed at this beamline and highlight important findings in enzyme chemistry that have been made possible by IMAGINE.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron diffraction discriminates between models for the nanoarchitecture of graphene sheets in glassy carbon

Glassy carbon is a chemically inert, biocompatible, disordered material with the graphene sheet as its basic building block. Structural characterisation techniques have so far been unable to provide definitive distinction between the many proposed models for its structure. Computer based simulation methods have made a step forward by predicting structure from interaction potentials, but the results are sensitive to the choice of the potential. Here we use the white neutron beam of the Spallation Neutron Source at Oak Ridge National Laboratory coupled with the SNAP time-of-flight diffractometer to sample the reciprocal space of glassy carbon and calculate accurate radial distribution functions. From the radial distribution information, we determine graphene sheet dimensions, registration, curvature, and assess defect content to rank the proposed structures in terms of their agreement with experimental data. In this work, we find that the recent models derived from empirical potentials give the best agreement.

36 MATERIALS SCIENCE↗

Neutron diffraction probing hydrogen in monoclinic H 2 VOPO 4

Light hydrogen atoms are resolvable with neutrons; however, the massive incoherent background inhibits the diffraction quality. To improve the signal, isotope treatment by deuteration becomes a prerequisite for a successful crystallographic understanding of hydrogen-containing materials by neutron diffraction. Thanks to the low-background and high-resolution time-of-flight neutron diffractometer, this work demonstrates a direct and successful measurement of high-quality neutron diffraction patterns of H 2 VOPO 4 powders, a precursor of a high-capacity alkali-ion battery cathode. The Rietveld refinement identifies the hydrogen coordinates, occupancy, and thermal parameters in the H 2 VOPO 4 lattice. Finally, the result highlights the unique capability of neutron diffraction for the structure characterization of hydrogen-containing materials, potentially without requiring costly and possibly artifact-inducing deuteration for neutron diffraction.

36 MATERIALS SCIENCE↗

An investigation on the structural stability of $\mathrm{ZIF}$-8 in water versus water-derived oxidative species in aqueous environment

We report the zeolitic-imidazolate-framework-8 (ZIF-8) is one of the extensively studied metal-organic frameworks (MOF) materials because of its unique structure. For its potential applicability in numerous fields, it becomes crucial to have detailed studies on the structural stability of ZIF-8, especially in aqueous environments. A number of studies have been conducted to investigate the breakdown process of the ZIF-8 structure in water; which is known as the hydrolysis of ZIF-8. However, those studies reported different opposing experimental observations on the role of water on the structural stability of ZIF-8, which created obscurity in understanding this phenomenon. This study explored the effects of different water-derived species on the structural stability of ZIF-8; specifically, examined the effects of only water and water with different oxidative species that may be generated by water molecules' dissociation under external energy or catalyst presence. To this effort, we experimentally probed the physical and chemical structural changes of ZIF-8 in DI water and three different solutions of hydrogen peroxides (H 2 O 2 ); taking H 2 O 2 as the source of oxidative species. To assess the changes in elemental compositions, chemical bonds, functional groups, crystal structure, and morphology, all the samples were analyzed by X-ray photoelectron spectroscopy (XPS), energy-dispersive x-ray (EDX) spectroscopy, Fourier Transform Infrared (FTIR) spectroscope, X-ray diffractometer (XRD), and scanning electron microscope (SEM). Significant structural changes in ZIF-8 occurred mainly in the presence of oxidative species in water. Notably, oxidative species' concentration exceeding 1 M heightened the deformation of the ZIF-8 structure.

36 MATERIALS SCIENCE↗

High temperature neutron diffraction investigation of U 3 Si 2

The U-Si system is actively undergoing studies due to its promise as a component of an accident tolerant nuclear fuel. In this work, the crystal structure of the U 3 Si 2 compound in the U-Si system was investigated as a function of temperature from room temperature to 1298 K for a sample of approximately 42.02 at.% Si composition and 1373 K for a sample with approximately 42.10 at.% Si using high temperature time-of-flight neutron diffraction on the High-Pressure Preferred Orientation (HIPPO) diffractometer at Los Alamos Neutron Science Center (LANSCE). The simultaneous Rietveld refinement of five histograms from the five HIPPO detector backs (40°, 60°, 90°, 120°, and 145°) provided datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of a homogeneity range, two sample compositions were analyzed, a 40.02 at.% Si (near stoichiometric) and a potentially hyperstoichiometric (40.10 at.% Si) sample. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were found indicative of a single phase sample and the ability of the U 3 Si 2 compound to accommodate nonstoichiometry, suggesting that the U 3 Si 2 compound is not a line compound confirming previous determinations. However, the differences observed in the average coefficient of linear thermal expansion identified between the two compositions warrant future investigation.

36 MATERIALS SCIENCE↗

Characterizing mineralization on low carbon steel exposed to aerated and degassed synthetic hydraulic fracture fluids

This study investigates the mineralization occurring at the interface between injected hydraulic fracturing fluids and steel production casing during the shut-in period of unconventional shale wells. Mild steel coupons were reacted with synthetic hydraulic fracturing fluids with varying base fluid and dissolved gas concentrations. Experiments were carried out in an autoclave system set at 50 °C and 2000 PSI for 2 and 14 days. Physical and mineralogical changes to the steel coupons’ surface were characterized using an FEI Quanta 600 field emission gun (FEG) scanning electron microscope (SEM) and a PANalytical XPert Pro diffractometer. Barite precipitation occurred ubiquitously during the first 48 hours in all experimental scenarios. Sulfate radicals created from degradation and reduction of ammonium persulfate breakers facilitate barite formation. Concomitant barite and corrosion related precipitates on the sample surfaces suggest iron hydroxy salts act as nucleation sites for mineral scale growth. These results suggest hydraulic fracturing fluids may have deleterious effects on the wellbore before production of the well begins.

36 MATERIALS SCIENCE↗