Search NASA⌕ Search

SEARCH · Search NASA

Results for “digitized waveform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Neutron Energy Measurements in Emergency Response Applications

We present significant results in recent advances in the measurement of neutron energy. Neutron energy measurements are a small but significant part of radiological emergency response applications. Mission critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the case of searching for special nuclear materials, neutron energy information from an unknown source can be of importance. At the Remote Sensing Laboratory (RSL) of National Security Technologies, LLC, a series of materials, viz., liquid organic scintillator (LOS), Lithium Gadolinium Borate (LGB) or Li6Gd(BO3)3 in a plastic matrix, a recently developed crystal of Cesium Lithium Yttrium Chloride, Cs2LiYCl6: Ce (called CLYC)[1], and normal plastic scintillator (BC-408) with 3He tubes have been used to study their effectiveness as a portable neutron energy spectrometer. Comparisons illustrating the strengths of the various materials will be provided. Of these materials, LGB offers the ability to tailor its response to the neutron spectrum by varying the isotopic composition of the key constituents (Lithium, Gadolinium [Yttrium], and Boron). All three of the constituent elements possess large neutron capture cross section isotopes for highly exothermic reactions. These compounds of composition Li6Gd(Y)(BO3)3 can be activated by Cerium ions Ce3+. CLYC, on the other hand, has a remarkable gamma response in addition to superb neutron discrimination, comparable to that of Europium-doped Lithium Iodide (6LiI: Eu). Comparing these two materials, CLYC has higher light output (4500 phe/MeV) than that from 6LiI: Eu and shows better energy resolution for both gamma and neutron pulse heights. Using CLYC, gamma energy pulses can be discriminated from the neutron signals by simple pulse height separation. For the cases of both LGB and LOS, careful pulse shape discrimination is needed to separate the gamma energy signals from neutron pulses. Both analog and digital methods have been applied to obtain a clear gamma and neutron energy spectrum in a mixed radiation field. A waveform digitizer manufactured by Agilent Technology Inc. has been successfully used to digitize the signal and separate the gamma and neutron signals to obtain a high gamma rejection ratio. These results along with some interesting data from a plastic (BC-408) and 3He dual gamma-neuron detector will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Laser Altimeter Return Waveforms Over Complex Vegetation Using High-Resolution Elevation Data

The upcoming generation of laser altimeters record the interaction of emitted laser radiation with terrestrial surfaces in the form of a digitized waveform. We model these laser altimeter return waveforms as the sum of the reflections from individual surfaces within laser footprints, accounting for instrument-specific properties. We compare over 1000 modeled and recorded waveform pairs using the Pearson correlation. We show that we reliably synthesize the vertical structure information for vegetation canopies contained in a medium-large diameter laser footprint from a high-resolution elevation data set.

Blair, J. Bryan↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Modeling Surface Structure Derived from Laser Altimeter Return Waveforms Using High-Resolution Elevation Data

The upcoming generation of operational spaceborne laser altimeters (i.e VCL and GLAS) record the interaction of emitted laser radiation with terrestrial surfaces in the form of a digitized waveform. We show that we can accurately model return laser altimeter waveforms as the sum of the reflections from individual surfaces within laser footprints. In one case, we predict return waveforms using high resolution elevation data generated by a small-footprint laser altimeter in a dense tropical forest. We compare over 3000 modeled and recorded waveform pairs using the Pearson correlation. The modeled and recorded waveforms are highly correlated, with a mean correlation of 0.90 and a median of 0.95. The mean correlation is highly dependent on the relative positions of the data sets. By shifting the relative locations of the two compared data sets, we infer that the data are colocated to within 0.4$\sim$m horizontally and 0.12$\sim$m vertically. The high degree of correlation shows that we can reliably synthesize the vertical structure information measured by medium-large footprint laser altimeters for complex, dense vegetation.

Blair, J. Bryan↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DSP Algorithms for Fission Fragment and Prompt Fission Neutron Spectroscopy

Digital signal processing (DSP) algorithms are in high demand for modern nuclear fission investigation due to importance of increase the accuracy of fissile nuclear data for new generation of nuclear power stations. DSP algorithms for fission fragment (FF) and prompt fission neutron (PFN) spectroscopy are described in the present work. The twin Frisch-grid ionization chamber (GTIC) is used to measure the kinetic energy-, mass- and angular distributions of the FF in the {sup 252}Cf(SF) reaction. Along with the neutron time-of-flight (TOF) measurement the correlation between neutron emission and FF mass and energy is investigated. The TOF is measured between common cathode of the GTIC and the neutron detector (ND) pulses. Waveform digitizers (WFD) having 12 bit amplitude resolution and 100 MHz sampling frequency are used for the detector pulse sampling. DSP algorithms are developed as recursive procedures to perform the signal processing, similar to those available in various nuclear electronics modules, such as constant fraction discriminator (CFD), pulse shape discriminator (PSD), peak-sensitive analogue-to-digital converter (pADC) and pulse shaping amplifier (PSA). To measure the angle between FF and the cathode plane normal to the GTIC a new algorithm is developed having advantage over the traditional analogue pulse processing schemes. Algorithms are tested by comparing the numerical simulation of the data analysis of the {sup 252}Cf(SF) reaction with data available from literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

The Prompt Fission Neutron Spectrum of 235 U(n,f) below 2.5 MeV for Incident Neutrons from 0.7 to 20 MeV

New prompt fission neutron spectrum measurements are reported for 235 U(n,f) reactions induced by neutrons with energies from 0.7 to 20 MeV. These measurements cover outgoing neutron energies from 2.5 MeV down to 10 keV, using an array of 6 Li-glass scintillators for neutron detection and a double time-of-flight technique. The neutrons were produced at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. A detailed MCNP ® model of the experimental equipment and the surrounding room was used to interpret the experimental results. Backgrounds were measured in situ, making use of the time-dependent singles rates of the various detectors with asynchronous readout from waveform digitizers. The results presented here have been included in a re-evaluation of the fission neutron spectra for this fissioning system, a description of which is presented elsewhere in this issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of an array of PbF 2 Cherenkov crystals with large-area SiPM readout

Here, the electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF 2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 - 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes versus energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 10 -4 per hour.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of ADC non-linearities on the sensitivity to sterile keV neutrinos with a KATRIN-like experiment

Here, ADC non-linearities are a major systematic effect in the search for keV-scale sterile neutrinos with tritium β-decay experiments like KATRIN. They can significantly distort the spectral shape and thereby obscure the tiny kink-like signature of a sterile neutrino. In this work we demonstrate various mitigation techniques to reduce the impact of ADC non-linearities on the tritium β-decay spectrum to a level of < ppm. The best results are achieved with a multi-pixel (≥ 10 4 pixels) detector using full waveform digitization. In this case, active-to-sterile mixing angles of the order of sin 2 θ = 10 –7 would be accessible from the viewpoint of ADC non-linearities. With purely peak-sensing ADCs a comparable sensitivity could be reached with highly linear ADCs, sufficient non-linearity corrections or by increasing the number of pixels to ≥ 10 5 .

74 ATOMIC AND MOLECULAR PHYSICS↗

Mu2e Calorimeter Readout System

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads , neutron flux of 10 12 n(1MeVeq)/cm 2 , magnetic field of 1T and in vacuum level of 10 -4 Torr . A description of the readout system and qualification tests is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise signal identification in time projection chamber data using deep learning model

Deep learning has been employed in various scientific fields and has provided promising results. Here, in this study, a deep learning classifier was implemented to improve the quality of data obtained from a time projection chamber. Digital waveforms of the detected signals were classified into the following three categories: particles, noises, and particles piled up with noises. A simple 1-dimensional convolutional neural network was developed for the classification. The model demonstrated an excellent performance on the test dataset. Its practical performance was also examined using track images and particle identification plots by comparing the original and clean data without the noise signals. The comparison clearly showed that the deep learning model improved the quality of data. The current study presents an effective application of the deep learning model for the time projection chamber data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗