Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hunting for Light Dark Matter with the NOvA Detector

Direct detection of dark matter is the ultimate goal of experimental physics. NOvA Near detector may becapable to put an upper limit on the lightweight dark matter (LDM) particle production, in the 120-GeVproton-nucleus collisions, engaged in producing the high-intensity NuMI neutrino beam. We summarizethe approach used in the search for the elastic, dark matter - electron scattering in the Near Detector, andbriefly mention two other efforts to observe the elusive dark matter interactions, with the NOvA detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for lepton-flavour-violating decays of the Higgs and Z bosons with the ATLAS detector

Direct searches for lepton flavour violation in decays of the Higgs and Z bosons with the ATLAS detector at the LHC are presented. The following three decays are considered: H → eτ, H → μτ, and Z → μτ. The searches are based on the data sample of proton–proton collisions collected by the ATLAS detector corresponding to an integrated luminosity of 20.3 fb –1 at a centre-of-mass energy of √s = 8 TeV. No significant excess is observed, and upper limits on the lepton-flavour-violating branching ratios are set at the 95% confidence level: Br(H → eτ) < 1.04%, Br(H → μτ) < 1.43%, and Br(Z → μτ) < 1.69 × 10 –5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter raining on DUNE and other large volume detectors

Direct detection is a powerful means of searching for particle physics evidence of dark matter (DM) heavier than about a GeV with o(kiloton) volume, low-threshold detectors. In many scenarios, some fraction of the DM may be boosted to large velocities enhancing and generally modifying possible detection signatures. We investigate the scenario where 100% of the DM is boosted at the Earth due to new attractive long-range forces. This leads to two main improvements in detection capabilities: (1) the large boost allows for detectable signatures of DM well below a GeV at large-volume neutrino detectors, such as DUNE, Super-K, Hyper-K, and JUNO, as possible DM detectors, and (2) the flux at the Earth’s surface is enhanced by a focusing effect. In addition, the model leads to a significant anisotropy in the signal with the DM flowing dominantly vertically at the Earth’s surface instead of the typical approximately isotropic DM signal. We develop the theory behind this model and also calculate realistic constraints using a detailed GENIE simulation of the signal inside detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

a-Si:H TFT-silicon hybrid low-energy x-ray detector

Direct conversion crystalline silicon X-ray imagers are used for low-energy X-ray photon (4-20 keV) detection in scientific research applications such as protein crystallography. In this paper, we demonstrate a novel pixel architecture that integrates a crystalline silicon X-ray detector with a thin-film transistor amorphous silicon pixel readout circuit. We describe a simplified two-mask process to fabricate a complete imaging array and present preliminary results that show the fabricated pixel to be sensitive to 5.89-keV photons from a low activity Fe-55 gamma source. Furthermore, this paper presented can expedite the development of high spatial resolution, low cost, direct conversion imagers for X-ray diffraction and crystallography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗

Light Dark Matter Detection with Hydrogen-Rich Targets and Low-$T_c$ TES Detectors

Direct detection of nuclear scatterings of sub-GeV dark matter (DM) particles favors low-Z nuclei. Hydrogen nucleus, which has a single proton, provides the best kinematic match. The characteristic nuclear recoil energy is boosted by a factor of a few tens from those for larger nuclei used in traditional Weakly Interacting Massive Particles searches. Furthermore, hydrogen is optimal for detecting spin-dependent nuclear scatterings of sub-GeV DM, where large parameter space still remains unconstrained yet. In this paper, we first introduce several hydrogen-rich targets, which emit two classes of signals under kinetic excitations. One class of the signals is infrared photons, which are from fundamental vibrational and rotational modes of molecules and at several characteristic wavelengths. Another is acoustic phonons and optical phonons that decay into acoustic phonons. Then we discuss the technical status and future researches of low-T c transition-edge sensor (TES) detectors, which measure the infrared photons and acoustic phonons with desirable sensitivities. Utilization of hydrogen-rich targets and ultra-sensitive low-T c TES detectors for light DM detection requires both theoretical modeling and experimental prototyping.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-crystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} detectors for direct detection of microwave radiation

We test radiation detectors made from single-crystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+x} flakes put on oxidized Si substrates. The 100-nm-thick flakes are lithographically patterned into 4×12 μm{sup 2} large rectangles embedded in thin-film log-spiral antennas. The SiO{sub 2} layer weakens the thermal link between the flakes and the bath. Two modes of radiation detection have been observed. For a bolometric type of sensors a responsivity of ∼300 V/W and a noise equivalent power of 30 nW/√(Hz) has been deduced at 70 K. Much more sensitive is the non-bolometric device showing characteristics similar to a Golay-type detector while being at least a thousand times faster. Making smaller (sub-μm) structures is expected to significantly improve the performance of these devices and makes them very competitive among other microwave and terahertz detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large-Angle Rocking Beam Electron Diffraction of Large Unit Cell Crystals Using Direct Electron Detector

We report a large-angle rocking beam electron diffraction (LARBED) technique for electron diffraction analysis. Diffraction patterns are recorded in a scanning transmission electron microscope (STEM) using a direct electron detector with large dynamical range and fast readout. We use a nanobeam for diffraction and perform the beam double rocking by synchronizing the detector with the STEM scan coils for the recording. Using this approach, large-angle convergent beam electron diffraction (LACBED) patterns of different reflections are obtained simultaneously. By using a nanobeam, instead of a focused beam, the LARBED technique can be applied to beam-sensitive crystals as well as crystals with large unit cells. Here, this paper describes the implementation of LARBED and evaluates the performance using silicon and gadolinium gallium garnet crystals as test samples. We demonstrate that our method provides an effective and robust way for recording LARBED patterns and paves the way for quantitative electron diffraction of large unit cell and beam-sensitive crystals.

4DSTEM↗

Integrated treatment of detector arrays for source tracking.

Illicit radioactive sources can potentially appear in a wide range of public venues. One element in a plan for managing such sources involves searching for them in venues at risk and tracking them in real time when they are detected. A treatment of source tracking using multiple directional detectors in a probabilistic framework is given. The performance of a prototype directional detector based on these methods was characterized in the laboratory. Instances where the performance of a directional detector is not immune to the effects of shielding are identified.

07 ISOTOPE AND RADIATION SOURCES↗

The Usefulness of Three-Dimensional Angiography with a Flat Panel Detector of Direct Conversion Type in a Transcatheter Arterial Chemoembolization Procedure for Hepatocellular Carcinoma: Initial Experience

The purpose of this study was to assess the usefulness of a three-dimensional (3D) angiography system using a flat panel detector of direct conversion type in treatments with subsegmental transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCCs). Thirty-six consecutive patients who underwent hepatic angiography were prospectively examined. First, two radiologists evaluated the degree of visualization of the peripheral branches of the hepatic arteries on 3D digital subtraction angiography (DSA). Then the radiologists evaluated the visualization of tumor staining and feeding arteries in 25 patients (30 HCCs) who underwent subsegmental TACE. The two radiologists who performed the TACE assessed whether the additional information provided by 3D DSA was useful for treatments. In 34 (94.4%) of 36 patients, the subsegmental branches of the hepatic arteries were sufficiently visualized. The feeding arteries of HCCs were sufficiently visualized in 28 (93%) of 30 HCCs, whereas tumor stains were sufficiently visualized in 18 (60%). Maximum intensity projection images were significantly superior to volume recording images for visualization of the tumor staining and feeding arteries of HCCs. In 27 (90%) of 30 HCCs, 3D DSA provided additional useful information for subsegmental TACE. The high-quality 3D DSA with flat panel detector angiography system provided a precise vascular road map, which was useful for performing subsegmental TACE .of HCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The DarkSide Multiton Detector for the Direct Dark Matter Search

A wide range of astronomical evidence implies the existence of Dark Matter, but as yet the nature of this major component of the Universe is completely unknown. A leading candidate explanation is that Dark Matter is composed of Weakly Interacting Massive Particles (WIMPs) formed in the early universe and gravitationally clustered together with the standard baryonic matter. Such WIMPs could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The predicted collision rates are very low and require ultra-low background detectors with large (0.1 { 10 tons) target masses, located in deep underground sites to reduce the background produced by neutrons from cosmic ray muons [1{4].

Dark Matter↗

Dual Gamma Neutron Directional Elpasolite Detector

Some applications, particularly in homeland security, require detection of both neutron and gamma radiation. Typically, this is accomplished with a combination of two detectors registering neutrons and gammas separately. We have investigated a new type of neutron/gamma (n/γ) directional detection capability. We explored a new class of scintillator, cerium (Ce)-doped Elpasolites such as Cs2LiYCl6:Ce (CLYC), Cs2LiLaCl6 (CLLC), Cs2LiLaBr6:Ce (CLLB), or Cs2LiYBr6:Ce (CLYB). These materials are capable of providing energy resolution as good as 2.9% at 662 keV (FWHM), which is better than that of NaI:Tl. Because they contain 6Li, Elpasolites can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 GEEn MeV. Thus, very effective pulse height discrimination is possible. In addition, the core-to-valence luminescence (CVL) provides Elpasolites with different temporal responses under gamma and neutron excitation, and, therefore, may be exploited for effective pulse shape discrimination. For instance, the CLLC emission consists of two main components: (1) CVL spanning from 220 nm to 320 nm and (2) Ce emission found in the range of 350 to 500 nm. The former emission is of particular interest because it appears only under gamma excitation. It is also very fast, decaying with a 2 ns time constant. The n/γ discrimination capability of Elpasolite detectors may be optimized by tuning the cerium doping content for maximum effect on n/γ pulse shape differences. The resulting Elpasolite detectors have the ability to collect neutron and gamma data simultaneously, with excellent discrimination. Further, an array of four of these Elpasolites detectors will perform directional detection in both the neutron and gamma channels simultaneously.

radiation detectors, neutron detectors, scintillat↗

Evaluation of the neutron background in a direct WIMP detector with neutron veto system based on Gd-doped liquid scintillator

A direct WIMP (Weakly Interacting Massive Particle) detector with a neutron veto system is designed to better reject neutrons. Two experimental configurations are studied in the present paper: one is for an Xe detector enclosed in a Gd-loaded scintillator and the other one is for an Xe detector placed inside a reactor neutrino detector. The Gd-doped liquid scintillator (or the neutrino detector) is used as a neutron veto device. The neutron backgrounds for the two experimental designs have been estimated using Geant4 simulations. The results show that the neutron backgrounds can decrease to O(0.1) events per year per tonne of liquid Xenon. We calculate the sensitivities to spin-independent WIMP-nucleon elastic scattering. An exposure of one tonne × year could reach a cross-section of about 6 × 10{sup −11} pb.

79 ASTRONOMY AND ASTROPHYSICS↗

The Case for Space-Borne Far-Infrared Line Surveys

The combination of sensitive direct detectors and a cooled aperture promises orders of magnitude improvement in the sensitivity and survey time for far-infrared and submillimeter spectroscopy compared to existing or planned capabilities. Continuing advances in direct detector technology enable spectroscopy that approaches the background limit available only from space at these wavelengths. Because the spectral confusion limit is significantly lower than the more familiar spatial confusion limit encountered in imaging applications, spectroscopy can be carried out to comparable depth with a significantly smaller aperture. We are developing a novel waveguide-coupled grating spectrometer that disperses radiation into a wide instantaneous bandwidth with moderate resolution (R ~ 1000) in a compact 2-dimensional format. A line survey instrument coupled to a modest cooled single aperture provides an attractive scientific application for spectroscopy with direct detectors. Using a suite of waveguide spectrometers, we can obtain complete coverage over the entire far-infrared and sub-millimeter. This concept requires no moving parts to modulate the optical signal. Such an instrument would be able to conduct a far-infrared line survey 10 6 times faster than planned capabilities, assuming existing detector technology. However, if historical improvements in bolometer sensitivity continue, so that photon-limited sensitivity is obtained, the integration time can be further reduced by 2 to 4 orders of magnitude, depending on wavelength. The line flux sensitivity would be comparable to ALMA, but at shorter wavelengths and with the continuous coverage needed to extract line fluxes for sources at unknown redshifts. For example, this capability would break the current spectroscopic bottleneck in the study of far-infrared galaxies, the recently discovered, rapidly evolving objects abundant at cosmological distances.

Bock, J. J.↗

Review of Dark Matter Direct Detection Using Cryogenic Detectors

The direct detection of the Universe's Dark Matter is one of the key questions in particle astrophysics. Cryogenic based detectors offer advantages in low radioactive backgrounds, target mass, sensitivity to the small energy depositions and rejection of possible background sources. I will summarize the main experimental approaches, including both cryogenic crystal and liquid targets and the options pursued for their signal readout. Recent advances from around the world and prospects for future proposed experiments will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact, directional neutron detectors capable of high-resolution nuclear recoil imaging

We report on the design, production, and performance of compact 40-cm3 Time Projection Chambers (TPCs) that detect fast neutrons by measuring the three-dimensional (3D) ionization distribution of nuclear recoils in 4 He:CO 2 gas at atmospheric pressure. We use these detectors to characterize the fast-neutron flux inside the Belle II detector at the SuperKEKB electron–positron collider in Tsukuba, Japan, where the primary design constraint is a small form factor. We find that the TPCs meet or exceed all design specifications, and are capable of measuring the 3D surface shape and charge density profile of ionization clouds from nuclear recoils and charged tracks in exquisite detail. Scaled-up detectors based on the detection principle demonstrated here may be suitable for directional dark matter searches, measurements of coherent neutrino–nucleus scattering, and other experiments requiring precise detection of neutrons or nuclear recoils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗