Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

Improved Control Strategy of Grid Interface for EV High-Power Dynamic Wireless Charging

This paper proposes a control strategy for the grid interface converter in high-power dynamic wireless charging system (DWCS) to address two issues on distribution network integration. Due to the unique pulsating load profile of DWCS, load transient response capability is critical for the grid interface to maintain the dc-bus voltage stable. Besides, the inherent unbalanced situation of distribution network would lead to 2nd-order oscillations on the dc-bus voltage, which would further affect the stable operation of the entire system. In this paper, the DWCS model is developed, and the relationship between the dc-bus voltage and the input/output power is analyzed. Based on the developed model, a control strategy based on direct power control is presented. Both simulation results and hardware-in-the-loop (HIL) results demonstrate that the proposed control strategy not only improves load transient response capability, but also eliminates the 2nd-order oscillations on the dc-bus voltage under imbalanced distribution network conditions.

Zeng, Rong↗

SolarPlus Optimizer: Integrated Control of Solar, Batteries, and Flexible Loads for Small Commercial Buildings

Building-level microgrids may be a key strategy to unlock the combined potential of flexible loads, renewable generation, and energy storage. However, few software options exist for integrated control of building loads and other distributed energy resources at this scale. The commercial software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice. The SolarPlus Optimizer (SPO) is an open-source building-level microgrid control platform that uses Model Predictive Control to optimize both building loads and behind-the-meter energy storage to reduce energy bills and increase demand flexibility. This paper evaluates the capabilities of SPO in a small commercial building in Northern California under multiple electricity tariffs and demand response scenarios. Comparing SPO operation with an emulated battery and baseline operation employing a commercial optimization service, SPO reduced electricity bills by an estimated 7.3% in summer, 3.2% in spring, and 3.7% in winter. In a “load shape” scenario meant to counter the “duck curve”, SPO achieved 71% fewer violations from the load signal than the baseline control method. During a three hour long load shed event, SPO reduced cooling and refrigeration load by 38%. This research shows significant potential to provide load flexibility for building-level microgrids for this type of control systems. Finally, the paper discusses the future direction of research on open-source control systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

Priority-enabled Load Balancing for Dispersed Computing

Opportunistic managed access to local in-network compute resources can improve the performance of distributed applications and reduce the dependence on shared network resources. Instead of backhauling application data to a centralized cloud data center for processing, networked services may be adaptively and continuously dispersed into shared compute resources that are closer to the source of need. While this approach has several benefits, support for mission-aware access to computation is often an afterthought, and is implemented as a brittle extension over traditional load-balancer solutions.In this work, we investigate the design of two priority-aware resource allocation strategies and two load-balancing dispatching strategies as first class citizens in an open-source dispersed computing middleware. We present a control theoretic analysis of these load-balancing primitives to identify weaknesses and strengths in our design, and recommend future directions. In parallel, we prototype two priority-aware allocation algorithms to validate our priority predictions. In initial experiments our prototype shows substantial gains in processing prioritized load. Finally, we make our source-code and experimental configurations open source.

Paulos, Aaron↗

Numerical Modelling of a Two-Body Point Absorber Featuring Variable Geometry

This work presents a novel wave energy converter (WEC) device concept that incorporates variable geometry modules into a two-body point absorber type WEC. The variable geometry modules consist of air inflatable bags in the surface float and a water inflatable ring in the reaction body. The variable geometry floats are able to provide greater control over the device hydrodynamics; they can be inflated or deflated to emphasize either power absorption or load shedding. The device geometry is controlled in a quasi-static fashion, while the power take-off (PTO) unit is controlled on a wave-to-wave timescale. The surface float is tethered directly to the submerged reaction body through PTO tether lines. A linear time-domain analysis, conducted using open-source Wave Energy Converter (WEC-Sim) software, was used to estimate the absorbed power of the WEC in sea states defined by the Wave Energy Prize. WEC power performance was weighted against the expected capital cost of building the load bearing structure of the device, providing an estimated ACE value. The inclusion of the variable geometry modules was shown to be effective in altering the device geometry to improve power capture with a near proportional increase in expected costs, providing a nearly constant power-to-cost ratio.

cost of energy↗

Model-based real-time surface heat flux and temperature estimation for the DIII-D tokamak

A control-oriented model for monitoring of wall power flux densities on the DIII-D tokamak has been successfully implemented and validated experimentally. Future reactors will have to withstand severe steady state high heat flux loads on plasma-facing components (PFCs). Due to the difficulty of directly-measuring local heat fluxes on these components, monitoring and protection of PFCs during the plasma discharge can benefit from simplified physics-based real-time (RT) functional models to estimate and guide heat load control. As a first step into the development, a control-oriented model for monitoring of wall power flux densities and temperatures on DIII-D tokamak has been successfully implemented. The paper discusses the experimental demonstration and comparison of the 2-D model-based wall heat flux algorithm on the DIII-Dinner wall limiter (IWL) against infra-red camera heat flux measurements for limited plasma configurations. The paper also reports on the benchmarking of the field line tracing environment, SMITER, developed at ITER organization on DIII-D tokamak against experimental IR diagnostic data and the derivation of the component shaping weighting factors for the 2-D model-based approach. Here, the extension of the model-based approach for surface temperature estimation on the DIII-D IWL is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aeroservoelastic Stability of a Floating Wind Turbine

The problem of negative damping undermines the aeroservoelastic stability of floating offshore wind turbines. The negative damping problem is most prevalent around rated wind speed, where the sensitivity of thrust to wind speed is the largest. This paper investigates the implementation of peak shaving, a controller feature that limits the rated thrust by pitching the blades before rated wind speed is reached. Two controller designs are investigated: a de-tuned controller and a nacelle-feedback controller. A time-domain metric is defined, inspired by Lyapunov theory, in order to compute and assess the stability of floating offshore wind turbines. The model of the International Energy Agency 15-MW reference wind turbine mounted on the University of Maine VolturnUS-S floater is simulated in HAWC2 with the National Renewable Energy Laboratory reference open-source controller. Peak shaving is applied to the two controller designs and stability is assessed. According to the chosen metric, peak shaving does not improve the stability of the system. This is due to the trade-off between loads and error tracking: although the loads and displacements in the fore-aft direction of the turbine are reduced, the rotor-speed tracking is poorer, which increases the shaft torsion fatigue load.

17 WIND ENERGY↗

A Data-Driven Algorithm for Enabling Delay Tolerance in Resilient Microgrid Controls Using Dynamic Mode Decomposition

The increased implementation of smart grid technologies in the power distribution grid presents unique opportunities that enable resiliency, but also brings challenges motivating needs for novel solutions and mitigation techniques. The bi-directional power and data flow allow for the grid to operate with increased resiliency, which is the ability to avoid discontinuity of service to end-use loads during extreme events. However, in applications where control of the distribution grid or microgrid relies on communication networks, the degradation of communication systems in the form of loss or high latency can cause maloperation and result in loss of end-use loads. Here this paper presents a novel framework to enable delay tolerance of centralized microgrid control schemes to mitigate communication system latency impacts and guarantee successful control action. We demonstrate the delay tolerance on a control scheme that operates a battery energy storage system (BESS) to offset the sudden loss of generation and maintain system frequency. During periods of severely degraded communication system performance, the proposed delay-tolerant algorithm compensates for the latency by utilizing a data-driven model generated at the device level using dynamic mode decomposition (DMD) to determine the performance of the communications. The DMD technique predicts the system’s frequency using device-level terminal measurements and provides updated control signals. The HELICS cosimulation platform evaluates the cyber-physical interaction of the power system model in GridLAB-D, the centralized control agent in Python, and the discrete network model in NS-3. The framework is tested and validated on the IEEE-123 node system modified to represent a networked remote microgrid model, and the results show an improvement in the dynamic performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modelling and assessing the near-wake representation and turbulence behaviour of control-oriented wake models

Due to the interaction between the wake of an upstream turbine on a downstream turbine, power losses and increased fatigue loads occur. By yawing the upstream turbine with regard to the wind direction, one can potentially reduce the power losses of the downstream turbine and reduce the fatigue loads. The evolution of the wake depends on the pressure gradient within the near-wake region and the turbulent kinetic energy and must be incorporated in existing wake steering algorithms to provide an accurate estimation of the wake flow. This paper will show a first approach to implement a near-wake model and a turbulence model in the curled wake model within the controls-oriented framework FLORIS. The near-wake model is based on an analytical expression of the velocity profile to model the pressure gradient. Furthermore, two turbulence models are incorporated within the curled wake model based on a Gaussian-distribution and a mixing length formulation. The adapted curled wake model is then assessed with the measurement data acquired in the wind tunnel at ForWind – University of Oldenburg. The evaluation of the models show good agreement for the velocity deficit and representation of the near-wake region. Furthermore, the turbulent kinetic energy behaved as expected in comparison to other work, showing a ring of high turbulent kinetic energy at non-yawed condition which is deflected to a curled shape at large yaw angles with the turbulence model based on a mixing length formulation.

FLORIS↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Understanding Impacts of Frequency Calculations on Underfrequency Load Shedding

Power system fundamental frequency-dependent protection decisions and control decisions are increasingly common in the distribution system space. Understanding the algorithms used in frequency measurements is critical to understanding the decisions made by the many intelligent electronic devices in the power system. These decisions are critically important for reliability analysis for interconnected power systems as they bear directly on resource planning to mitigate under-frequency conditions that would result in under-frequency load shedding (UFLS). This work aims to improve the understanding of frequency measurement algorithms, evaluate the intelligent electronic devices that use frequency measurements for decision making, and understand the algorithms' direct impact on frequency related decision making. First, this work presents background information on the use of frequency measurements in protection logic, specifically UFLS. Second, the paper presents a relay hardware evaluation test bed used to detect and protect systems from under-frequency events. Finally, the paper presents the dynamic events used to evaluate commercially available, off-the-shelf relay equipment and the results from the relay evaluation.

COMTRADE↗

Dynamically Learning Incentives for Load Control

As electrical generation becomes more distributed and volatile, and loads become more uncertain, controllability of distributed energy resources (DERs), regardless of their ownership status, will be necessary for grid reliability. Grid operators lack direct control over end-users' grid interactions, such as energy usage, but incentives can influence behavior -- for example, an end-user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. A key challenge in studying such incentives is the lack of data about human behavior, which usually motivates strong assumptions, such as distributional assumptions on compliance or rational utility-maximization. In this paper, we propose a general incentive mechanism in the form of a constrained optimization problem -- our approach is distinguished from prior work by modeling human behavior (e.g., reactions to an incentive) as an arbitrary unknown function. We propose feedback-based optimization algorithms to solve this problem that each leverage different amounts of information and/or measurements. We show that each converges to an asymptotically stable incentive with (near)-optimality guarantees given mild assumptions on the problem. Finally, we evaluate our proposed techniques in voltage regulation simulations on standard test beds. We test a variety of settings, including those that break assumptions required for theoretical convergence (e.g., convexity, smoothness) to capture realistic settings. In this evaluation, our proposed algorithms are able to find near-optimal incentives even when the reaction to an incentive is modeled by a theoretically difficult (yet realistic) function.

demand response↗

Pseudoelastic deformation in Mo-based refractory multi-principal element alloys

Phase diagrams supported by density functional theory methods can be crucial for designing high-entropy alloys that are subset of multi-principal-element alloys. We present phase and property analysis of quinary (MoW) x Zr y (TaTi) 1-x-y refractory high-entropy alloys from combined Calculation of Phase Diagram (CALPHAD) and density-functional theory results, supplemented by molecular dynamics simulations. Both CALPHAD and density-functional theory analysis of phase stability indicates a Mo-W-rich region of this quinary has a stable single-phase body-centered-cubic structure. We report first quinary composition from Mo-W-Ta-Ti-Zr family of alloy with pseudo-elastic behavior, i.e., hysteresis in stress-strain. Our analysis shows that only Mo-W-rich compositions of Mo-W-Ta-Ti-Zr, i.e., Mo+W, show reproducible hysteresis in stress-strain responsible for pseudo-elastic behavior. The (MoW) 85 Zr 7.5 (TaTi) 7.5 was down-selected based on temperature-dependent phase diagram analysis and molecular dynamics simulations predicted elastic behavior that reveals twinning-assisted pseudoelastic behavior. While mostly unexplored in body-centered-cubic crystals, twinning is a fundamental deformation mechanism that competes against dislocation slip in crystalline solids. Furthermore, this alloy shows identical cyclic deformation characteristics during uniaxial < 100 > loading, i.e., the pseudoelasticity is isotropic in loading direction. Additionally, a temperature increase from 77 to 1,500 K enhances the elastic strain recovery in load-unload cycles, offering possibly control to tune the pseudoelastic behavior.

36 MATERIALS SCIENCE↗

Load balancing for multi-beam additive manufacturing systems

As powder bed fusion (PBF) additive manufacturing (AM) becomes a more mature field, system configurations are gradually moving away from the classic single heat source, layer-by-layer system configurations towards unconventional system configurations that offer higher throughput. Higher throughput systems allow PBF systems to be considered for a larger variety of industrial applications. However, the inclusion of multiple heat sources, or beams, also increases the complexity of the control schemes needed. For multi-beam systems with overlapping fields of view, the distribution of workload, or load balancing, across these beams directly affects the total print time for a build. Additionally, the probability of any beam failing in a multi-beam system increases with the number of beams. While manual methods of load balancing and dealing with beam failures are reasonable for current generation multi-beam systems, as system configurations become more complex, manual methods will become prohibitively inefficient. Here, this paper introduces two different ways to load balance multi-beam systems of various configuration types, regardless of their complexity, which are highly performant. A consequence of this performance is the enablement of on-the-fly load balancing in the event a beam fails, thus improving system robustness.

36 MATERIALS SCIENCE↗

Computational Methods to Characterize Panel Loading Conditions for Accelerated Testing

Panel cracking and degradation due to wind loading are known to have a detrimental effect on power output. Recreating these damaging conditions in a controlled experimental setting requires an understanding of the loads being generated at the panel surface as a function of both wind speed, wind direction, and panel orientation. To better understand these relationships, a computational fluid dynamics (CFD) simulation package was constructed using an open-source Python library for solving partial differential equations with the finite element method. This CFD package allows the simulated wind speed and panel orientation of a multi-panel array to be easily changed and provides the capability to measure the traction forces at discrete points along the sun-facing and ground-facing surface of an interior panel residing in the wake of one or more upstream panels. A parameter exploration was performed in which the panel angle was varied in even increments from -70 deg to 70 deg and the wind speed was varied from 2 to 30 m/s. During post processing, the measured traction along the panel surface was averaged spatially and interpreted as a time-varying signal, where further processing of this signal yielded the root mean square amplitude and a characteristic frequency associated with the loading. This study found that higher wind speeds are generally associated with increased amplitude of loading and that the panel orientation angle can significantly exacerbate or mitigate this loading. These outcomes are presented along with current work on higher-fidelity verification simulations and recommendations for performing accelerated experimental testing.

loading↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗