Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Energy Delivery Systems with Verifiable Trustworthiness (Final Report)

Energy Delivery Systems (EDS) must be verified to be free from intrusive and malicious software. One way of verifying this software is to perform device scans to detect malicious code. Because it is possible to have “fileless” malware that exists only in device (volatile) memory, offline scanning and even many forms of online scanning is insufficient for detection. This project (“Verify”) addresses this need by performing direct sampling of memory during device operation to detect unexpected or modified software while not interfering with device operation. The Verify project provides a proof-of-concept of detection by random sampling combined with remote software- and timing-based attestation methods for robust detection of in-memory threats. An external review of Verify was performed by our partner, General Electric (GE), and a summary of their findings is provided.

97 MATHEMATICS AND COMPUTING↗

Smokeless Chimney using Smoke Opacity as a Combustion Control Parameter (CRADA Final Report)

If operated poorly, wood burning heaters can produce large amounts of particulate matter (PM). Although several instruments are available to monitor PM, most require dilution air and are unable to sample directly from a flue due to the high PM concentrations and temperatures. Opacity sensors can measure color, opacity and smoke density from wood heater stacks. They operate by transmitting a light beam through the emission source and measuring the amount of light intensity lost (opacity) and light not reflected (color). Although opacity sensors are used in several areas, none have been thoroughly evaluated or optimized for measuring smoke from wood heaters.

47 OTHER INSTRUMENTATION↗

Hierarchical Modeling to Enhance Spectrophotometry Measurements—Overcoming Dynamic Range Limitations for Remote Monitoring of Neptunium

A robust hierarchical model has been demonstrated for monitoring a wide range of neptunium concentrations (0.75–890 mM) and varying temperatures (10–80 °C) using chemometrics and feature selection. The visible–near infrared electronic absorption spectrum (400–1700 nm) of monocharged neptunyl dioxocation (Np(V) = NpO2+) includes many bands, which have molar absorption coefficients that differ by nearly 2 orders of magnitude. The shape, position, and intensity of these bands differ with chemical interactions and changing temperature. These challenges make traditional quantification by univariate methods unfeasible. Measuring Np(V) concentration over several orders of magnitude would typically necessitate cells with varying path length, optical switches, and/or multiple spectrophotometers. Alternatively, the differences in the molar extinction coefficients for multiple absorption bands can be used to quantify Np(V) concentration over 3 orders of magnitude with a single optical path length (1 mm) and a hierarchical multivariate model. In this work, principal component analysis was used to distinguish the concentration regime of the sample, directing it to the relevant partial least squares regression submodels. Each submodel was optimized with unique feature selection filters that were selected by a genetic algorithm to enhance predictions. Through this approach, the percent root mean square error of prediction values were ≤1.05% for Np(V) concentrations and ≤4% for temperatures. This approach may be applied to other nuclear fuel cycle and environmental applications requiring real-time spectroscopic measurements over a wide range of conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Value of Nodes with Multicommunity Membership for Classification with Graph Convolutional Neural Networks

Sampling is an important step in the machine learning process because it prioritizes samples that help the model best summarize the important concepts required for the task at hand. The process of determining the best sampling method has been rarely studied in the context of graph neural networks. In this paper, we evaluate multiple sampling methods (i.e., ascending and descending) that sample based off different definitions of centrality (i.e., Voterank, Pagerank, degree) to observe its relation with network topology. We find that no sampling method is superior across all network topologies. Additionally, we find situations where ascending sampling provides better classification scores, showing the strength of weak ties. Two strategies are then created to predict the best sampling method, one that observes the homogeneous connectivity of the nodes, and one that observes the network topology. In both methods, we are able to evaluate the best sampling direction consistently.

97 MATHEMATICS AND COMPUTING↗

Dark Energy Survey Year 3 Results: Measuring the Survey Transfer Function with Balrog

Abstract We describe an updated calibration and diagnostic framework, Balrog , used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) data set. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant “source” galaxies and magnification biases of nearer “lens” galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ∼1–8 mmag, but for a small subset of objects, we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. We discuss approaches to extend the current methodology to capture more aspects of the transfer function and reach full coverage of the survey footprint for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

No Galaxy Left Behind: Measuring the Transfer Function of the Dark Energy Survey with Balrog

In this dissertation, we describe a calibration and diagnostic framework called Balrog which was used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) dataset. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with traditional generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant "source" galaxies and magnification biases of nearer "lens" galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the fiducial Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ~1-8 millimagnitudes, but for a small subset of objects we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. Finally, we discuss approaches to extend the current methodology to capture more aspects of the transfer function for future analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-tooth bosonic quantum comb for temporal-correlation sensing

We introduce a two-tooth bosonic quantum comb that captures the sequential interactions between a thermal absorber and a long-lived coherent probe. The comb provides a causal, multi-time description of coherence transport, tracking how the probe records both instantaneous fluctuations and their temporal correlations. Using a process-tensor formulation, we derive closed form expressions showing that interference between the two interaction windows generates a non-monotonic memory response that reflects a fundamental competition between the absorbers thermal population and its dynamical correlations. By sweeping the temporal separation between the interaction windows, the probe directly samples the absorbers population correlator, enabling bosonic noise spectroscopy that discriminates Markovian temperature noise from slow or spectrally structured fluctuations. The approach is readily compatible with circuit-QED platforms and offers a general method for probing fluctuating bosonic environments.

Zhu, Shaojiang [Fermilab]↗

Fisher Forecasting for the DESC with $\texttt{Augur}$

The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) has begun its ten-year survey of the entire visible southern hemisphere. To ensure robust cosmological measurements, computationally inexpensive investigations of modeling choices must be made to gauge the performance of proposed cosmological analyses. In this paper, we introduce the $\texttt{Augur}$ tool of the Dark Energy Science Collaboration (DESC), which provides Fisher forecasts for cosmological inference for the LSST using software frameworks designed for DESC science. We test the pipeline by comparing it to forecasts produced by external code and direct sampling of the posterior via nested sampling methods, finding good agreement between all methods. We additionally investigate a range of modeling and hyperparameter choices for a 3$\times$2pt investigation in harmonic space, providing users with diagnostics to obtain reliable forecasts. $\texttt{Augur}$ will be continually updated to be compatible with the other tools in the DESC software ecosystem as additional probes and functionality become available.

Rogozenski, Paul [Carnegie Mellon U.; Arizona U.] ↗

Assessment of Bulk Oxygen Capacity and Transient Redox Behavior of Foamed Lanthanum Strontium Manganese Perovskites

Synthesis of solar thermochemical hydrogen (STCH) production redox materials with engineered structures, for example, replica foams, can enable efficient heat and mass transport and are critical for scaled-up systems. Prior work has motivated the use of lanthanum strontium manganese (LSM)-type perovskites as foamed STCH materials, but the effect of their morphology on bulk and kinetic behavior has not been reported. In this work, replica and direct foamed samples of La 0.65 Sr 0.35 MnO 3-δ (LSM35) were fabricated and compared to synthesized powders and dense monoliths, and similarly synthesized CeO 2-δ (ceria) foams, regarding their specific reaction rates and bulk oxygen capacity/H 2 yields. Changes in oxygen capacity (Δδ) and reaction rates were measured between 1200 °C and 1400 °C by using fixed ratios of steam and hydrogen during both reduction and oxidation steps, allowing for analysis under practical high conversion conditions. Results suggest bulk behavior and reaction rates of the foamed LSM materials are comparable to their powder analogues. Differences in reaction rates were observed only when replica foamed samples were subjected to rapid laser heating (emulating conditions expected in solar furnaces), which is expected but has not been demonstrated at such a small scale. Here, foamed samples were further subjected to 50 redox cycles at 1400 °C to evaluate their stability. Results show no statistically significant decrease in hydrogen production for any of the foamed samples, but the direct foamed samples became brittle with time. Together, these results demonstrate the viability of replica foamed LSM perovskites for integration in scaled-up STCH systems.

08 HYDROGEN↗

Sample changers for direct geometry neutron chopper spectrometers

The advent of higher flux neutron sources has made the use of sample changers appropriate across the instrument suites at neutron scattering facilities. We examine the efficiency, design, and operation of two sample changers used at the thermal chopper spectrometers at the Spallation Neutron Source. We also present case studies of sample holders designed to accommodate multiple single crystal or powder samples for the Cold Neutron Chopper Spectrometer at the Spallation Neutron Source. [This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).]

Stone, Matthew B. [Oak Ridge National Laboratory (↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Characterization of the biofilm landscape of Bacillus subtilis by spatial microproteomics

Bulk proteomics has been demonstrated to differentiate subpopulations within bacterial colonies, yet advanced analyses by mass spectrometry imaging (MSI) hold even greater promise for the future. This technology can enable high-throughput spatial phenotyping that can reshape biological discovery by providing visualization of components of various biomolecular mechanisms. With high mass resolving power and high spatial resolution analyses being routine, we can confidently enable intact protein imaging directly from samples with minimal preparation. Pairing those analyses with bulk experimental libraries can provide high confidence in annotations of post-translational modifications (PTMs) and truncations. Revealing PTM localization within the samples unlocks a direct window into unknown biology at the microscale. However, top-down proteomics (TDP) is not commonplace for microbial species, largely due to challenges in identifying detected peptides and proteins; considering the theoretical proteome of even the well-studied model bacterium Bacillus subtilis was only partially mapped recently. With little still known about the form and function of many of these proteins – let alone proteoforms, where PTMs and truncations of the same protein may possess unique physiological roles – there is a wealth of work to be done. Here we jointly apply TDP and MSI to describe the microscale spatial proteomic landscape within B. subtilis and further demonstrate the feasibility of detecting differentiated subpopulations through proteoforms across the biofilm landscape.

bacterial biofilms↗

In Situ Synchrotron X-ray Micro-Diffraction Investigation of Elastic Strains in Laminated Ti-Al Composites

Spatially resolved elastic strains in the bulk interior of a laminated Ti-Al metal composite were studied during in situ tensile loading at strains up to 1.66% by a synchrotron-based micro-diffraction technique, namely differential aperture X-ray microscopy (DAXM). For both Al and Ti grains, deviatoric elastic strains were estimated based on polychromatic X-ray microbeam diffraction, while lattice strains along the normal direction of the tensile sample were directly measured using monochromatic X-ray microbeam diffraction. The estimated deviatoric strains show large spatial variations, and the mean values are consistent with the external loading conditions, i.e., increasing tensile strain along the tensile direction and increasing compressive strain along the sample normal with increasing loading. The directly measured lattice strains also show large spatial variations, although the magnitude of this variation is smaller than that for the estimated deviatoric strain. The directly measured lattice strains in Ti grains are largely consistent with the external loading, whereas those in Al grains are in contradiction with the external loading. The causes of the experimental results are discussed and related to both the laminated microstructure of the composite material and the limitations of the techniques.

36 MATERIALS SCIENCE↗

Whole genome sequencing of Mycobacterium bovis directly from clinical tissue samples without culture

Advancement in next generation sequencing offers the possibility of routine use of whole genome sequencing (WGS) for Mycobacterium bovis (M. bovis) genomes in clinical reference laboratories. To date, the M. bovis genome could only be sequenced if the mycobacteria were cultured from tissue. This requirement for culture has been due to the overwhelmingly large amount of host DNA present when DNA is prepared directly from a granuloma. To overcome this formidable hurdle, we evaluated the usefulness of an RNA-based targeted enrichment method to sequence M. bovis DNA directly from tissue samples without culture. Initial spiking experiments for method development were established by spiking DNA extracted from tissue samples with serially diluted M. bovis BCG DNA at the following concentration range: 0.1 ng/μl to 0.1 pg/μl (10 –1 to 10 –4 ). Library preparation, hybridization and enrichment was performed using SureSelect custom capture library RNA baits and the SureSelect XT HS2 target enrichment system for Illumina paired-end sequencing. The method validation was then assessed using direct WGS of M. bovis DNA extracted from tissue samples from naturally (n = 6) and experimentally (n = 6) infected animals with variable Ct values. Direct WGS of spiked DNA samples achieved 99.1% mean genome coverage (mean depth of coverage: 108×) and 98.8% mean genome coverage (mean depth of coverage: 26.4×) for tissue samples spiked with BCG DNA at 10 –1 (mean Ct value: 20.3) and 10 –2 (mean Ct value: 23.4), respectively. The M. bovis genome from the experimentally and naturally infected tissue samples was successfully sequenced with a mean genome coverage of 99.56% and depth of genome coverage ranging from 9.2× to 72.1×. The spoligoyping and M. bovis group assignment derived from sequencing DNA directly from the infected tissue samples matched that of the cultured isolates from the same sample. Our results show that direct sequencing of M. bovis DNA from tissue samples has the potential to provide accurate sequencing of M. bovis genomes significantly faster than WGS from cultures in research and diagnostic settings.

59 BASIC BIOLOGICAL SCIENCES↗

Integration and Demonstration of Monitoring, Modeling, and Prediction of DV-1 Amendment Performance at the Bench Scale: DV-1 Amendment Demonstration

During fiscal years 2024 and 2025, the U.S. Department of Energy’s Hanford Field Office commissioned Pacific Northwest National Laboratory to conduct applied research aimed at reducing the cost, time, and uncertainty associated with in situ treatment of vadose zone contaminants at the Hanford Site. This report outlines the integration of three key research efforts into a meso-scale demonstration designed to advance field-scale solutions that aim to (1) optimize the delivery of chemical amendments to contaminated soils, (2) reduce uncertainty in amendment delivery performance assessment using advanced monitoring techniques, and (3) provide real-time insights into when and where amendment-induced precipitation reactions occur in the subsurface. To achieve these objectives, the tank-scale (~ 1 cubic meter) Geophysical Imaging of Flow and Transport (GIFT) system was developed. GIFT enables experimental testing of amendment delivery while incorporating automated multi-modal monitoring approaches, including pressure measurements, direct fluid sampling, and remote time-lapse geophysical imaging. The data generated from these monitoring techniques will serve as inputs for a generative artificial-intelligence-driven digital twin – a numerical simulation model designed to honor observed data while quantifying uncertainty in simulation accuracy. Using this simulator, researchers will refine an amendment injection strategy to maximize delivery efficiency within a low-permeability soil zone. Monitoring data will be interpreted through simulated outputs to enhance understanding of the injection process. The efficacy of this integrated approach will be evaluated through direct sampling at the conclusion of the experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗