Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dielectric Fluids for the Direct Forced Convection Cooling of Power Electronics

The future of electrification of vehicles and other systems will require the creation of high-power density power electronics with low junction-to-fluid thermal resistance cooling solutions. One way to create this solution is to move high-heat-flux liquid cooling (single- or two-phase) as close to the power electronics components as possible. One novel approach involves submersion in dielectric fluids as the cooling solution. We first provide the range of fluid properties and develop a figure of merit (FOM) to aid in dielectric fluid selection. Next, we perform computational fluid dynamics/heat transfer (CFD/HT) modeling using single-phase cooling (submerged jet impingement on an enhanced surface) to validate the dielectric fluid FOM. Results of the study show that the developed FOM is a good representation of the performance of the fluids when compared to the results of the CFD/HT analysis. Both FOM and the CFD/HT analysis show that based on pure thermohydraulic considerations, several commercially available fluids present higher performance, on the order of 5% of water. Finally, the FOM can be used to quickly assess the thermohydraulic performance of a dielectric fluid, as well as the secondary application-specific properties such as boiling point, saturation pressure, flash point, and global warming potential, thereby allowing for fluid candidates to be readily compared.

computational fluid dynamics↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

An Update on Cardinal: Toward Full Core Pebble Simulations

The new DOE-NE Center of Excellence for Thermal-fluids applications in Nuclear Energy inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water nuclear Reactors (LWRs) as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single solve-all algorithm for physical fluid flow problems that will span nine orders of magnitude in spatial and temporal scales. To demonstrate the multi-scale philosophy of the center we focus on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkley’s PB-FHR Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid Fluoride salt working fluids - such as Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multi-scale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000/NekRS) and fuel performance (BISON). As part of Center of Excellence ongoing research efforts we have developed Cardinal, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. The present report provides an update on the development of Cardinal with an extension of Cardinal to GPUs. We also perform a first-of-a-kind demonstration simulation on Summit representing a 10x capability increase in terms of pebble count for Cardinal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The effect of direct heating and cooling of heat regulation centers on body temperature

Experiments were done on 28 rabbits in which puncture instruments were left in the brain for 1-2 days until the calori-puncture hyperthermia had passed and the body temperature was again normal. The instrument remaining in the brain was then used as a galvanic electrode and a second fever was produced, this time due to the electrical stimulus. It was concluded that heat is a centrally acting antipyretic and that cold is a centrally acting stimulus which produces hyperpyrexia cold-induced fever.

Barbour, H. G.↗

Transient motion of a confined rarefied gas due to wall heating or cooling

The direct Monte Carlo method is used to simulate the transient motion of a confined rarefied gas as a container wall is rapidly heated or cooled. Results show that, for the rapid wall temperature changes, the gas response is better measured by an acoustic, rather than conduction, timescale, with steady state conditions being achieved after about ten wave crossing times.

Wadsworth, Dean C.↗

Computational and Experimental Investigation of Discrete “W” Turbulators for sCO2 Turbine Internal Cooling

Direct-fired supercritical CO2 (sCO2 ) cycles are of particular interest for power generation due to the potential for higher thermal efficiencies with inherent CO2 capture. Direct fired sCO2 turbines must withstand high temperatures and the density of the working fluid is much higher than conventional Brayton cycles. Based on conventional Brayton cycle applications, internal serpentine cooling channels with ribbed turbulator strips are a common approach to achieve the required cooling, while minimizing coolant utilization. Most of the previous studies of coolant channel heat transfer enhancements have focused on serpentine channels using air as the cooling media at Reynold’s numbers typical of Brayton cycles. This paper investigates the Nusselt number augmentation of coolant channels with no features, ribbed turbulators, and discrete “W” turbulators with surface roughness effects included and CO2 as the coolant. The numerical results are compared to experimental results using CO2 as the cooling media at Reynold’s numbers ranging from 100,000 to 300,000. The results show the Nusselt number augmentation plateaus with increasing Reynolds number, in contrast to the decay observed in prior publications with air as the coolant media. Additionally, the CFD results indicate the discrete “W” geometry provides a 10% increase in Nusselt number augmentation relative to the angled ribbed turbulators.

computational fluid dynamics (CFD)↗

Application of Simulated Reactivity Feedback in Nonnuclear Testing of a Direct-Drive Gas-Cooled Reactor

Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.

Bragg-Sitton, S. M.↗

Toward Cooling Uniformity: Investigation of Spiral, Sweeping Holes, and Unconventional Cooling Paradigms

Surface infrared thermography, hotwire anemometry, and thermocouple surveys were performed on two new film cooling hole geometries: spiral/rifled holes and fluidic sweeping holes. Ways to quantify the efficacy of novel cooling holes that are asymmetric, not uniformly spaced or that show variation from hole to hole are presented. The spiral holes attempt to induce large-scale vorticity to the film cooling jet as it exits the hole to prevent the formation of the kidney shaped vortices commonly associated with film cooling jets. The fluidic sweeping hole uses a passive in-hole geometry to induce jet sweeping at frequencies that scale with blowing ratios. The spiral hole performance is compared to that of round holes with and without compound angles. The fluidic hole is of the diffusion class of holes and is therefore compared to a 777 hole and square holes. A patent-pending spiral hole design showed the highest potential of the nondiffusion type hole configurations. Velocity contours and flow temperature were acquired at discreet cross-sections of the downstream flow field. The passive fluidic sweeping hole shows the most uniform cooling distribution but suffers from low span-averaged effectiveness levels due to enhanced mixing. The data was taken at a Reynolds number of 11,000 based on hole diameter and freestream velocity. Infrared thermography was taken for blowing ratios of 1.0, 1.5, 2.0, and 2.5 at a density ratio of 1.05. The flow inside the fluidic sweeping hole was studied using 3D unsteady RANS. A section on ideas for future work is included that addresses issues of quantifying cooling uniformity and provides some ideas for changing the way we think about cooling such as changing the direction of cooling or coupling acoustic devices to cooling holes to regulate frequency.

Shyam, Vikram↗

Terrestrial radiative cooling: Using the cold universe as a renewable and sustainable energy source

Photonic materials designed at wavelength scales have enabled a range of emerging energy technologies, from solid-state lighting to efficient photovoltaics that have transformed global energy landscapes. Daytime passive radiative cooling materials shed heat from the ground to the cold universe by taking advantage of the terrestrial thermal radiation that is as large as the renewable solar energy. Newly developed photonic materials permit subambient cooling under direct sunshine, and their applications are expanding rapidly enabled by scalable manufacturing. We review here the recent advancement of daytime subambient radiative cooling materials, which allow energy-efficient cooling and are paving the way toward technologies that harvest the coldness from the universe as a new renewable energy source.

Science & Technology - Other Topics↗

Cardinal: A Lower-Length-Scale Multiphysics Simulator for Pebble-Bed Reactors

This paper demonstrates a multiphysics solver for pebble-bed reactors, in particular, for Berkeley’s pebble-bed -fluoride-salt-cooled high-temperature reactor (PB-FHR) (Mark I design). The FHR is a class of advanced nuclear reactors that combines the robust coated particle fuel form from high-temperature gas-cooled reactors, the direct reactor auxiliary cooling system passive decay removal of liquid-metal fast reactors, and the transparent, high-volumetric heat capacitance liquid-fluoride salt working fluids (e.g., FLiBe) from molten salt reactors. This fuel and coolant combination enables FHRs to operate in a high-temperature, low-pressure design space that has beneficial safety and economic implications. The PB-FHR relies on a pebble-bed approach, and pebble-bed reactors are, in a sense, the poster child for multiscale analysis. Relying heavily on the MultiApp capability of the Multiphysics Object-Oriented Simulation Environment (MOOSE), we have developed Cardinal, a new platform for lower-length-scale simulation of pebble-bed cores. The lower-length-scale simulator comprises three physics: neutronics (OpenMC), thermal fluids (Nek5000/NekRS), and fuel performance (BISON). Cardinal tightly couples all three physics and leverages advances in MOOSE, such as the MultiApp system and the concept of MOOSE-wrapped applications. Moreover, Cardinal can utilize graphics processing units for accelerating solutions. In this paper, we discuss the development of Cardinal and the verification and validation and demonstration simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid-Cooled Heat Sink Optimization for Thermal Imbalance Mitigation in Wide-Bandgap Power Modules

Power semiconductor die layout in substrates used in power modules is generally optimized for minimum electrical parasitics (e.g., stray inductance) by considering the minimum spacing between dies for thermal decoupling. The layout assumes sufficient heat spreading and transfer from dies to the cooling structure. For module designs using a direct substrate cooling method, the base plate is removed, leading to a steady-state thermal asymmetry in the power module due to insufficient heat spreading/transfer. This causes significant temperature differences among the devices. Such unintentional thermal asymmetries can lead to undesirable asymmetries in power conversion among semiconductor devices, which impact reliability. This article proposes a thermal imbalance mitigation method that uses evolutionary optimized liquid-cooled heat sinks to improve the thermal loading among devices.

Sahu, Raj↗

Actively Cooled SLMS(TM) Technology for HEL Applications

Mr. Jacoby is the Chief Scientist for Schafer's Lightweight Optical Systems business area with twenty four years experience in laser and optical systems for space and military applications. He and colleague Dr. Goodman conceived and developed Silicon Lightweight Mirrors (SLMS(TM)) technologies for space applications from the extreme UV to FAR IR wavelengths. Schafer has demonstrated two different methods for actively cooling our Silicon Lightweight Mirrors (SLMS(TM)) technology. Direct internal cooling was accomplished by flowing liquid nitrogen through the continuous open cell core of the SLMS(TM) mirror. Indirect external cooling was accomplished by flowing liquid nitrogen through a CTE matched Cesic square-tube manifold that was bonded to the back of the mirror in the center. Testing was done in the small 4-foot thermal/vacuum chamber located at the NASA/MSFC X-Ray Calibration Facility. Seven thermal diodes were located over the front side of the 5 inch diameter mirror and one was placed on the outlet side of the Cesic manifold. Results indicate that the mirror reaches steady state at 82K in less than four minutes for both cooling methods. The maximum temperature difference of the eight diodes was less than 200 mK when the mirror was internally cooled and covered with MLI to insulate it from the large 300 K aluminum plate that was used to mount it.

Jacoby, Marc T.↗

Two-point and multiple-point spot heating and cooling

Apparatus and methods for producing thermal comfort using two point or multipoint heating or cooling that is applied to portion of a human body part to produce a warm or cool sensation over a larger area than that where the heating or cooling is directly applied. The body is induced to heat or cool itself by adjusting its neutral temperature setpoints. Increased warming perception from two-point, multipoint, and switching point stimulation causes downward adaptation in the neutral skin temperature of the user. Because spot heating and cooling sources operate at higher temperature differences from the skin than do area sources, they create a stronger perceived thermal sensation for the same power consumption. Point heating or cooling, rather than whole-area heating, can result in power savings and cost savings while improving occupant comfort.

Arens, Edward↗

Nucleation and growth of plagioclase and the development of textures in a high-alumina basaltic melt

Detailed experiments on the nucleation and growth of plagioclase from an igneous melt are carried out to characterize the magma prior to cooling. It is shown that the nature of the melt directly preceding cooling has a strong effect on texture development, regardless of the origin of the melt. The number, size, and shape of the crystals present in a melt upon extrusion can have a drastic effect on the final textures present in the resulting rocks. Conditions necessary for the formation of poikilitic, intersertal, and porphyritic textures in basaltic rocks are defined.

Nabelek, P. I.↗

A One-dimensional Heat Transfer Model for a Cooled Airfoil in a Direct-fired Supercritical CO 2 Turbine

A one-dimensional (1-D) heat transfer model was developed to predict the performance of a cooled airfoil for a supercritical carbon dioxide (sCO 2 ) turbine. The model included the effects of film cooling effectiveness, thermal barrier coating thickness, and internal Nusselt number augmentation. Trends for overall cooling effectiveness versus heat load parameter were obtained for over twelve unique thermal management schemes. The study found that adding a thermal barrier coating was the most effective scheme for increasing the airfoil overall cooling effectiveness. Internal cooling technologies have diminishing returns as the heat transfer coefficient augmentation increases past a factor of five, however the sensitivity of overall cooling effectiveness to heat transfer augmentation scales by a factor of 1.3 when a thermal barrier coating is introduced. Film cooling is seen as a long-term research area which will be inevitably explored as direct sCO 2 systems develop a market presence. However, the model indicates that realizable film cooling effectiveness levels yield a smaller improvement in overall cooling effectiveness than a thermal barrier coating.

42 ENGINEERING↗

Single and Double-Sided Jet Impingement Cooling for SiC-Based Power Modules

Efficient thermal management of power electronics systems is crucial for higher reliability. With the miniaturization of systems, high-loss-density electronics require cooling systems that can extract a large amount of heat. This study explored a liquid-jet-impingement-based direct substrate cooling system for single-sided and double-sided cooling to improve heat extraction efficiency and improve the power density by reducing the volume and mass. The cooling system was implemented for a SiC-based direct bonded copper substrate. Numerical simulations were performed to determine the effects of nozzle diameter, the number of nozzles, and nozzle array orientation on single-sided cooling and thermal performance gain over double-sided cooling. A novel manifold design was proposed that reduced the volume and mass of the manifold and still achieved the target power density. The performance of the proposed design was compared with the pin-fin-based cooling system used in the BMW I3 module, and a comparative analysis was done.

Barua, Himel↗