Search NASA⌕ Search

SEARCH · Search NASA

Results for “discharge current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Response of lead-acid batteries to chopper-controlled discharge

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses at up to 25 percent compared to constant current discharges at the same average discharge current of 100 A. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-A pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Numerical Simulations of the Partially-Ionized Gas in a 100-A LaB6 Hollow Cathode

Numerical simulations of a hollow cathode with a LaB6 emitter operating at 100 A have been performed for the first time using the 2-D Orificed Cathode (OrCa2D) code. Results for a variety of plasma properties are presented and compared with laboratory measurements. The large size of the device permits peak electron number densities in the cathode interior that are lower than those established in the NSTAR hollow cathode, which operates with a 7.3x lower discharge current and 3.2x lower mass flow rate. Also, despite the higher discharge current in the LaB6 cathode, the maximum electron current density is lower, by 4.2x, than that in the NSTAR cathode due to the larger orifice size. Simulations and direct measurements show that at 12 sccm of xenon flow the peak emitter temperature is in the range of 1594-1630 C. It is also found that the conditions for the excitement of current-driven streaming instabilities and ion-acoustic turbulence (IAT) are satisfied in this cathode, similarly to what was found in the past in its smaller counterparts like the NSTAR cathode. Based on numerical simulations, it has long been argued that these instabilities may be responsible for the anomalously large ion energies that have been measured in these discharges as well as for the enhancement of the plasma resistivity. Confirmation of the presence of IAT in this cathode is presented for the first time in a companion paper.

robotic exploration↗

Effects of an Internally-Mounted Cathode on Hall Thruster Plume Properties

The effects of cathode position on the plume properties of an 8 kW BHT-8000 Busek Hall thruster are discussed. Experiments were conducted at the Jet Propulsion Laboratory (JPL) in a vacuum chamber suitable for the development and qualification of high-power Hall thrusters. Multi-mode Hall thruster operation was demonstrated at operating conditions ranging from 200-500 V discharge voltage, 10-40 A discharge current, and 2-8 kW discharge power. Reductions in plume divergence and increased near-field plume symmetries were found to result from the use of an internally-mounted cathode instead of the traditional externally-mounted configuration. High-current hollow cathodes developed at JPL utilizing lanthanum hexaboride (LaB6) emitters were also demonstrated. Discharge currents up to 100 A were achieved with the cathode operating alone and up to 40 A during operation with the Hall thruster. LaB6 cathodes were investigated because of their potential to reduce overall system cost and risk due to less stringent xenon purity and handling requirements.

electric propulsion↗

Effects of an internally-mounted cathode on hall thruster plume properties

The effects of cathode position on the plume properties of an 8 kW BHT-8000 Busek Hall thruster are discussed. Experiments were conducted at the Jet Propulsion Laboratory (JPL) in a vacuum chamber suitable for the development and qualification of high-power Hall thrusters. Multi-mode Hall thruster operation was demonstrated at operating conditions ranging from 200-500 V discharge voltage, 10-40 A discharge current, and 2-8 kW discharge power. Reductions in plume divergence and increased near-field plume symmetries were found to result from the use of an internally-mounted cathode instead of the traditional externally-mounted configuration. High-current hollow cathodes developed at JPL utilizing lanthanum hexaboride (LaB6) emitters were also demonstrated. Discharge currents up to 100 A were achieved with the cathode operating alone and up to 40 A during operation with the Hall thruster. LaB6 cathodes were investigated because of their potential to reduce overall system cost and risk due to less stringent xenon purity and handling requirements.

Fitzgerald, Dennis J.↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Reconfiguration of an Electrothermal-Arc Plasma Source for In Situ PMI Studies

An electrothermal-arc plasma source (ET-Arc) has been developed to produce transient plasma heat and particle fluxes similar to those produced by edge localized modes onto divertor plasma-facing components in tokamaks. The ET-Arc utilizes a capacitive discharge to send current through a 4-mm-diameter, 9-cm-long capillary source liner. The liner material is ablated to form a high-velocity plasma jet that impacts the target downstream. With the current discharge circuit configuration, pulse lengths are 1 to 2 ms in duration and deliver heat fluxes of 0.25 to 2.1 GW m-2. The plasma was previously characterized with optical emission spectroscopy (OES) on helium emission lines. The He I line ratios were interpreted with collisional radiative analysis to calculate ne and Te. The electron temperature and electron density ranged from Te = 1 to 5 eV and ne = 1022 to 1028 electrons/m3, respectively.

Lindquist, Elizabeth G.↗

A 50 cm diameter annular ion engine

An ion engine design is presented which uses an annular geometry as a means of achieving large engine diameters and hence, high thrust levels. Preliminary results are discussed for discharge-only operation of a 50-cm-diameter annular ion engine. Measured operating parameters presented include discharge current and voltage characteristics, discharge chamber ion current distribution, engine body temperatures, plasma flatness parameter effects and total integrated grid ion current.

Aston, Graeme↗

An analysis of the frequency characteristics of corona discharge at low pressure

Corona discharge is becoming more of a concern now that the space program is looking at higher power and voltage requirements for future missions. Improved detection methods for studying corona discharge will increase the knowledge base of how this phenomenon occurs, what effects it has on power systems, and how it is affected by outside influences. A better understanding of corona discharge will enable designers to improve on the space applications of insulation and dielectrics, and develop proper detection techniques. A test system was designed and constructed to measure the frequency spectrum of corona discharge current in low pressure. Various test samples in different arrangements were energized by ac voltage until corona discharge occurred. This same test was repeated at different pressures. The results indicate that the frequency spectrum of the discharge current changes with a change in pressure. At low pressures, the discharge frequency spectrum is concentrated in a narrow band with a peak at 17 kHz. As the pressure is increased, the spectral width increases to include components across a much broader band. Other tests were performed to correlate the frequency spectrum data to the shape of the discharge pulse and the physical appearance of the glow discharge.

T Gregory Lewis↗

Preliminary Development and Testing of a Self-Injecting Gallium MPD Thruster

Discharge current and terminal voltage measurements were performed on a gallium electromagnetic thruster at discharge currents in the range of 20-54 kA. It was found that the arc impedance has a value of 6-7 m(Omega) at peak current. The absence of high-frequency oscillations in the terminal voltage trace indicates lack of the "onset" condition often seen in MPD arcs, suggesting that a sufficient number of charge carriers are present for current conduction. The mass ablated per pulse was not measured experimentally; however the mass flow rate was calculated using an ion current assumption and an anode power balance. Measurement of arc impedance predicts a temperature of 3.5 eV which from Saha equilibrium corresponds to Z = 2.0 - 3.5, and assuming Z = 2 yields an Isp of 3000 s and thrust efficiency of 50%.

Thomas, Robert E.↗

Low-Power Operation and Plasma Characterization of a Qualification Model SPT-140 Hall Thruster for NASA Science Missions

Hall thruster systems based on commercial product lines can potentially lead to lower cost electric propulsion (EP) systems for deep space science missions. A 4.5-kW SPT-140 Hall thruster presently under qualification testing by SSL leverages the substantial heritage of the SPT-100 being flown on Russian and US commercial satellites. The Jet Propulsion Laboratory is exploring the use of commercial EP systems, including the SPT-140, for deep space science missions, and initiated a program to evaluate the SPT-140 in the areas of low power operation and thruster operating life. A qualification model SPT-140 designated QM002 was evaluated for operation and plasma properties along channel centerline, from 4.5 kW to 0.8 kW. Additional testing was performed on a development model SPT-140 designated DM4 to evaluate operation with a Moog proportional flow control valve (PFCV). The PFCV was commanded by an SSL engineering model PPU-140 Power Processing Unit (PPU). Performance measurements on QM002 at 0.8 kW discharge power were 50 mN of thrust at a total specific impulse of 1250 s, a total thruster efficiency of 0.38, and discharge current oscillations of under 3% of the mean current. Steady-state operation at 0.8 kW was demonstrated during a 27 h firing. The SPT-140 DM4 was operated in closed-loop control of the discharge current with the PFCV and PPU over discharge power levels of 0.8-4.5 kW. QM002 and DM4 test data indicate that the SPT-140 design is a viable candidate for NASA missions requiring power throttling down to low thruster input power.

Garner, Charles E.↗

Characterizing Electrical Arc Behavior in Ion Engines

Gridded ion engines represent a class of electric thrusters characterized by high propulsive efficiency and high total impulse capabilities. These engines operate by applying high voltage to multi-aperture electrodes, thereby electrostatically accelerating plasma to generate thrust. Within the course of normal operations, periodic occurrences of high voltage breakdowns manifest within the thruster. These breakdowns constitute an inherent aspect of operation, with observations indicating a diminishing frequency and total count over the thruster's operational lifespan. To safeguard the propulsion system during such occurrences, the power processing unit (PPU) employs an automated arc extinction sequence, termed "recycle," which is triggered upon detection of an over-current condition. The initial phase of this sequence involves momentarily deactivating the high voltage and reducing the discharge current to a predetermined level, minimizing plasma impingement as the ion beam is defocused. The high voltage is subsequently reapplied, and the discharge current is returned to its nominal value. The entire sequence typically spans approximately 800 milliseconds. Throughout a recycle event, the propulsion system experiences various current and voltage transients as the arc current traverses the system and different power supplies are toggled on and off.

electric propulsion↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Physics of Micro-Pinches

This project focused on using pulsed-power-driven techniques to study the coupling of high-energy-density (HED) magnetic fields to HED matter in the laboratory. Specifically, we studied a phenomenon known as "micro-pinching" to obtain HED conditions on a modest, university-scale pulsed-power driver: the 1-MA, 100-ns MAIZE linear transformer driver (LTD) facility at the University of Michigan. We used the "X-pinch" platform as a means of generating micro-pinch HED plasmas. An X-pinch is formed when two or more wires are crossed into the shape of an 'X' and a large electrical current is driven through the wires. This creates an intense electrical current density at the crossing point of the wires. Associated with this current density is an intense magnetic field and an intense magnetic field pressure. The magnetic field pressure compresses and heats the wire material into the HEDP regime. The use of an X-pinch platform ensures that the micro-pinch HED plasma will form in a well-controlled location, which helps with diagnostics alignment. This platform allowed us to explore the extreme plasma conditions and magnetic field pressures that can be generated with compact pulsed-power technology and intensely focused discharge currents. Understanding the limits of intensely focused discharge currents could have an enormous impact on HED science, especially when one considers the scaling of these platforms to the 30-MA Z facility at Sandia National Laboratories, where pressures well in excess of 1 Gbar could be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A mathematical approach for evaluating nickel-hydrogen cells

A mathematical equation is presented which gives a quantitative relationship between time-voltage discharge curves, when a cell's ampere-hour capacity is determined at a constant discharge current. In particular the equation quantifies the initial exponential voltage decay; the rate of voltage decay; the overall voltage shift of the curve and the total capacity of the cell at the given discharge current. The results of 12 nickel-hydrogen boiler plate cells cycled to 80 percent depth-of-discharge (DOD) are discussed in association with these equations.

Leibecki, H. F.↗

Temporal Fluctuations in a 100-A LaB6 Hollow Cathode

The temporal fluctuations in the near plume of a 100-Amperes LaB6 (Lanthanum hexaboride) hollow cathode are experimentally investigated. At high currents, turbulent oscillations may contribute to two of the anomalous processes of hollow cathode operation - anomalous resistivity and the production of energetic ions. A detailed study of the properties of the oscillations in a high current cathode is necessary to determine the impact of the fluctuation spectrum on these two effects. In this investigation, a probe array is employed to measure the amplitude and dispersion of axial modes in the plume while a retarding potential analyzer yields estimates of the radial ion energy distribution. The onset of the ion acoustic turbulence (IAT) is observed at high current values, and the character of the turbulent spectrum is shown to agree with weak turbulent theory: the amplitude of the spectrum decreases with flow rate but increases with discharge current. Estimates of the anomalous collision frequency based on experimental observations indicate that the IAT collision frequency can exceed the classical collision frequency at sufficiently high discharge current densities. Additionally, the onset of the IAT is shown to be correlated with the appearance of a high energy ion tail and that the energy in this tail is comparable to the energy in the experimentally-observed IAT.

production of ions↗

Power and energy capacity tradeoffs in an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) can provide energy storage and produce electrical power from low-grade waste heat instead of electricity. The use of all-aqueous copper-based electrolytes has recently produced higher power densities than those achieved using previous TRAB approaches based on reversible metal deposition and dissolution processes, but further gains are possible in power and energy density. We investigated the limitations of power and energy density and how they are impacted by the electrolyte composition and discharge currents. By increasing the ammonia concentration from 1 to 5 M, the power density of the battery increased from 11.2 to 28.5 mW cm –2 , but the energy density decreased from 0.56 to 0.31 Wh L –1 . Increasing discharge current densities from 4 to 12.5 mA cm –2 increased the average power density during discharge from 2.4 to 5.9 mW cm –2 without appreciable losses in energy density. Increasing the copper concentration from 0.1 to 0.5 M increased both energy density to 2.15 Wh L –1 and energy efficiency to 2.2% but did not substantially impact the power density. Furthermore, these results represent the highest performance metrics achieved for a low-grade waste heat to electricity system.

25 ENERGY STORAGE↗