Search NASA⌕ Search

SEARCH · Search NASA

Results for “discharge current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preliminary Evaluation of a 10 kW Hall Thruster

A 10 kW Hall thruster was characterized over a range of discharge voltages from 300-500 V and a range of discharge currents from 15-23 A. This corresponds to power levels from a low of 4.6 kW to a high of 10.7 kW. Over this range of discharge powers, thrust varied from 278 mN to 524 mN, specific impulse ranged from 1644 to 2392 seconds, and efficiency peaked at approximately 59%. A continuous 40 hour test was also undertaken in an attempt to gain insight with regard to long term operation of the engine. For this portion of the testing the thruster was operated at a discharge voltage of 500 V and a discharge current of 20 A. Steady-state temperatures were achieved after 3-5 hrs and very little variation in performance was detected.

Jankovsky, Robert S.↗

High-Speed Imaging of the First Kink Mode Instability in a Magnetoplasmadynamic Thruster

One of the biggest challenges to efficient magnetoplasmadynamic thruster (MPDT) operation is the onset of high-frequency voltage oscillations as the discharge current is increased above a threshold value. The onset regime is closely related to magnetohydrodynamic instabilities known as kink modes. This work documents direct observation of the formation and quasi-steady state behavior of an argon discharge plasma in a MPDT operating at discharge currents of 8 to 10 kA for a pulse length of approximately 4 ms. A high-speed camera images the quasi-steady-state operation of the thruster at 26,143 fps with a frame exposure time of 10 micro s. A 0.9 neutral density filter and 488-nm argon line filter with a 10-nm bandwidth are used on separate trials to capture the time evolution of the discharge plasma. Frame-by-frame analysis of the power flux incident on the CCD sensor shows both the initial discharge plasma formation process and the steady-state behavior of the discharge plasma. Light intensity levels on the order of 4-6 W/m2 indicate radial and azimuthal asymmetries in the concentration of argon plasma in the discharge channel. The plasma concentration exhibits characteristics that suggest the presence of a helical plasma column. This helical behavior has been observed in previous experiments that characterize plasma kink mode instabilities indirectly. Therefore, the direct imaging of these plasma kink modes further supports the link between MPDT onset behavior and the excitation of the magnetohydrodynamic instabilities.

Walker, Jonathan A.↗

A model for mercury orificed hollow cathodes - Theory and experiment

A phenomenological model is developed which provides a qualitative description of the basic physical processes taking place within a mercury orifice hollow cathode. This model can be used to predict, to first order, the important cathode operating parameters such as emission length and insert temperature. By assuming an idealized ion production region within which most of the plasma processes are concentrated, the model can be expressed analytically as a simple set of equations which relate cathode dimensions and specifiable operating conditions, such as mass flow rate and discharge current, to such important parameters as insert temperature and plasma properties. A comparison of theoretical and experimental results shows that, if the excited state energy flux is neglected, the model provides relatively accurate predictions of emission length, emission surface temperature, plasma density, and fraction of discharge current due to volume ionization

Siegfried, D. E.↗

LDEF SP-HVDE (space plasma-high voltage drainage experiment) post-flight data on spacecraft leakage current and discharge

Two identical SP-HVDE (Space Plasma-High Voltage Drainage Experiment) trays were designed and fabricated and were flown in the NASA LDEF in the LEO environment. The trays were placed with one near the leading edge and one near the trailing edge, and investigation was performed to compare the environmental interactions on the dielectric samples of the two trays. The original objective was successfully achieved by measuring the first in-flight long term average leakage current through 156 coulometers. Less than 5 percent anomalous behavior of the coulometers were found in the post flight analysis.

Yaung, J. Y.↗

LDEF SP-HVDE (Space Plasma-High Voltage Drainage Experiment) post-flight results: Leakage current and discharge

TRW designed and fabricated two identical SP-HVDE trays which were flown in the NASA LDEF (Long Duration Exposure Facility) for 5.75 years in the LEO (low earth orbit) environment. One tray was placed near the leading edge and one near the trailing edge, and investigations were performed to compare the environmental interactions on the dielectric samples of the two trays. Each tray consisted of six assemblies with Kapton dielectric samples of varying thicknesses (i.e., 2 mils, 3 mil, and 5 mils) biased under +/- 300 V, +/- 500 V, and +/- 1000 V. The original objective was successfully achieved by measuring the first in-flight average leakage current through the samples. Less than 5 percent of the post-flight coulometers behaved anomalously. The data should be valuable to the design and evaluation of spacecraft with high voltage systems. M/D (micrometeoroid and debris) impacts over the dielectric samples were examined using a SEM (Scanning Electron Microscope) and an EDS (Energy Dispersive x-ray Spectrometer). These impact sites were sprayed by silver which were most likely caused either by the impact or a 'local ESD' (electrostatic discharge).

Yaung, J. Y.↗

LEO spacecraft leakage current and discharging phenomena - TRW LDEF SP-HVDE (space plasma-high voltage drainage experiment)

Two identical SP-HVDE trays were flown in the NASA 5.75-year LDEF (Long Duration Exposure Facility), one near the leading edge and the other near the trailing edge, in the LEO (low earth orbit) environment. Each experiment tray consisted of six assemblies with each made of Kapton dielectric samples of varying thicknesses (i.e., 2 mils, 3 mils, and 5 mils) biased under +/- 300 V, +/- 500 V, and +/- 1000 V. The objectives have been successfully achieved by measuring the first post-flight long-term (i.e. roughly 8-month experiment) average leakage current through 95 percent measurable coulombmeters and surface materials.

Yaung, J. Y.↗

Response of nickel to zinc cells to electric vehicle chopper discharge waveforms

The preliminary results of simulated electric vehicle chopper controlled discharge of a Nickel/Zinc battery shows delivered energy increases of 5 to 25 percent compared to constant current discharges of the same average current. The percentage increase was a function of chopper frequency, the ratio of peak to average current, and the magnitude of the discharge current. Because the chopper effects are of a complex nature, electric vehicle battery/speed controller interaction must be carefully considered in vehicle design to optimize battery performance.

Cataldo, R. L.↗

Extended Wear Testing of the 12-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first wear test of the 12 kW Advanced Electric Propulsion System (AEPS) intended to isolate the impact of discharge current on component wear rates. Testing was led by Aerojet Rocketdyne and performed with the AEPS Engineering Test Unit 2 (ETU-2) thruster. In total, approximately 860 hours of operation were accumulated split between operating conditions of 600 V/9 kW, 600 V/11 kW, and 600 V/12 kW. Thruster performance and stability were invariant throughout the wear test for all thruster throttle conditions and shown to be equal to the values previously measured with ETU-2. Inner front pole cover erosion rates were found to be invariant to discharge current as the measurements at all three operating conditions were equal to within the empirical uncertainty. Outer front pole cover erosion rates were found to be equal for the 600 V/9 kW and 600 V/12 kW conditions with operation at 600 V/11 kW yielding elevated erosion rates. Overall, the data shows that the AEPS thruster design has a high probability of meeting lifetime and performance requirements as the design proceeds to flight production and qualification.

Jason D Frieman↗

Extended Wear Testing of the 12-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first wear test of the 12 kW Advanced Electric Propulsion System (AEPS) intended to isolate the impact of discharge current on component wear rates. Testing was led by Aerojet Rocketdyne and performed with the AEPS Engineering Test Unit 2 (ETU-2) thruster. In total, approximately 860 hours of operation were accumulated split between operating conditions of 600 V/9 kW, 600 V/11 kW, and 600 V/12 kW. Thruster performance and stability were invariant throughout the wear test for all thruster throttle conditions and shown to be equal to the values previously measured with ETU-2. Inner front pole cover erosion rates were found to be invariant to discharge current as the measurements at all three operating conditions were equal to within the empirical uncertainty. Outer front pole cover erosion rates were found to be equal for the 600 V/9 kW and 600 V/12 kW conditions with operation at 600 V/11 kW yielding rates that were comparable to those on the inner front pole cover. Overall, the data shows that the AEPS thruster design has a high probability of meeting lifetime and performance requirements as the design proceeds to flight production and qualification.

HERMeS↗

Experimental Investigation of Electron Cloud Containment in a Nonuniform Magnetic Field

Dense clouds of electrons were generated and studied in an axisymmetric, nonuniform magnetic field created by a short solenoid. The operation of the experiment was similar to that of a low-pressure (approximately 0.000001 Torr) magnetron discharge. Discharge current characteristics are presented as a function of pressure, magnetic field strength, voltage, and cathode end-plate location. The rotation of the electron cloud is determined from the frequency of diocotron waves. In the space charge saturated regime of operation, the cloud is found to rotate as a solid body with frequency close to V sub a/phi sub a where V sub a is the anode voltage and phi suba is the total magnetic flux. This result indicates that, in regions where electrons are present, the magnetic field lines are electrostatic equipotentials (E bar, B bar = 0). Equilibrium electron density distributions suggested by this conditions are integrated with respect to total ionizing power and are found consistent with measured discharge currents.

Eninger, J. E.↗

Iodine Hall Thruster Propellant Feed System for a CubeSat

There has been significant work recently in the development of iodine-fed Hall thrusters for in-space propulsion applications.1 The use of iodine as a propellant provides many advantages over present xenon-gas-fed Hall thruster systems. Iodine is a solid at ambient temperature (no pressurization required) and has no special handling requirements, making it safe for secondary flight opportunities. It has exceptionally high ρI sp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing system level advantages over mid-term high power electric propulsion options. Iodine provides thrust and efficiency that are comparable to xenonfed Hall thrusters while operating in the same discharge current and voltage regime, making it possible to leverage the development of flight-qualified xenon Hall thruster power processing units for the iodine application. Work at MSFC is presently aimed at designing, integrating, and demonstrating a flight-like iodine feed system suitable for the Hall thruster application. This effort represents a significant advancement in state-of-the-art. Though Iodine thrusters have demonstrated high performance with mission enabling potential, a flight-like feed system has never been demonstrated and iodine compatible components do not yet exist. Presented in this paper is the end-to-end integrated feed system demonstration. The system includes a propellant tank with active feedback-control heating, fill and drain interfaces, latching and proportional flow control valves (PFCV), flow resistors, and flight-like CubeSat power and control electronics. Hardware is integrated into a CubeSat-sized structure, calibrated and tested under vacuum conditions, and operated under under hot-fire conditions using a Busek BHT-200 thruster designed for iodine. Performance of the system is evaluated thorugh accurate measurement of thrust and a calibrated of mass flow rate measurement, which is a function of reservoir temperature/pressure, the flow resistors, and the setting of the PFCV. The calibration is performed using independent flow control monitoring techniques, providing an in situ measure of the flowrate as a function of controllable parameters. The reservoir temperature controls the iodine sublimation rate, providing propellant to ths thruster by pressurizing the propellant feed system to approx.1-2 psi. Control of the temperature and the PFCV are used to maintain reservoir pressure and keep the thruster discharge current constant.

Polzin, Kurt A.↗

High-Power Performance of a 100-kW Class Nested Hall Thruster

Operations of a three-channel 100-kW class nested Hall thruster at total power levels from 5 to 102 kW and discharge currents from 16 to 247 A were successful. The thruster was operated in all seven available channel combinations at discharge voltages of 300, 400, and 500 V and at current densities that were 0.60 and 0.95 of the nominal value. Additional test points were also collected at 1.20 the nominal current density. The thruster was throttled through a total of forty-six unique operating conditions. At each condition, thruster performance was measured using a high-power thrust stand designed to measure up to 8 N of thrust. From these thrust measurements, specific impulse and efficiency were calculated. All seven channel combinations showed similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.42 N at 99 kW, 400 V discharge voltage. Total efficiency values 0.54 to 0.67, and total specific impulse ranged from 1800 seconds to 2650 seconds. Discharge current oscillations were also measured. Generally these oscillations increased on the inner and middle channels during multi-channel mode but stayed roughly a constant fraction of the channel discharge current for the outer channel in both single- and multi-channel operation. We also found that the thrust of the three channels firing together was not significantly higher than the sum of each channel _ring individually, a result that differs from what was found previously for nested Hall thrusters.

Hall, Scott J.↗

Evaluation of advanced high rate Li-SOCl2 cells

Under NASA sponsorship, JPL is developing advanced, high rate Li-SOCl2 cells for future space missions. As part of this effort, Li-SOCl2 cells of various designs were examined for performance and safety. The cells differed from one another in several aspects, such as: nature of carbon cathode, catalysts, cell configuration, case polarity, and safety devices. Performance evaluation included constant-current discharge over a range of currents and temperatures. Abuse-testing consisted of shortcircuiting, charging, and over-discharge. Energy densities greater than 300 Wh/Kg at the C/2 rate were found for some designs. A cell design featuring a high-surface-area carbon cathode was found to deliver nearly 500 Wh/Kg at moderate discharge rates. Temperature influenced the performance significantly.

Deligiannis, F.↗

Discharge stabilization studies of CO laser gas mixtures in quasi-steady supersonic flow

Experiments were conducted to study the applicability of a double discharge stabilization scheme in conditions appropriate for high energy CO lasers in supersonic flows. A Ludwieg tube impulse flow facility and a ballasted capacitor bank provided essentially steady flow and discharge conditions (d.c.) for times longer than ten electrode length-flow transit times. Steady, arc-free, volume discharges were produced in a Mach 3 test cavity using an auxiliary discharge to stabilize the main discharge in N2 and He/CO mixture. A signigicant result is the lack of observed plasma E/N changes in response to auxiliary discharge current changes. Also, where glow discharges were obtained, the energy loading achieved was very much less than the threshold level required for laser operation.

Srinivasan, G.↗

Design model for the baffle aperture region of a hollow cathode thruster

A current balance on the main discharge chamber of an electron bombardment thruster is carried out. It is shown that the discharge current is the sum of the net cathode emission current, the beam current, and the ion current to cathode potential surfaces. Measurements of ion currents outside the virtual anode surface in a SERT II divergent magnetic field thruster show that relatively few ions cross this surface. This implies that ions are directed preferentially toward the anode and cathode pole pieces. A simple theoretical model useful as an aid in the design of the baffle aperture region of a hollow cathode equipped thruster is developed. The electron diffusion process through the aperture is modeled in accordance with the Bohm diffusion theory. The model is shown to yield consistent results for a given thruster geometry over substantial changes in operating conditions. The model's design usefulness is limited by a factor of two uncertainty observed over different thruster/cathode region geometries and by the accuracy to which the plasma parameters required as inputs to the model can be specified.

Brophy, J. R.↗

Charging and discharging characteristics of dielectric materials exposed to low- and mid-energy electrons

Charging and discharging characteristics of dielectric samples exposed to 1-25 keV and 25-100 keV electrons in a laboratory environment are reported. The materials examined comprised OSR, Mylar, Kapton, perforated Kapton, and Alphaquartz, serving as models for materials employed on spacecraft in geosynchronous orbit. The tests were performed in a vacuum chamber with electron guns whose beams were rastered over the entire surface of the planar samples. The specimens were examined in low-impedance-grounded, high-impedance-grounded, and isolated configurations. The worst-case and average peak discharge currents were observed to be independent of the incident electron energy, the time-dependent changes in the worst case discharge peak current were independent of the energy, and predischarge surface potentials are negligibly dependent on incident monoenergetic electrons.

Coakley, P.↗

Evaluation of nickel-hydrogen battery for space application

Results of electrical space qualification tests of nickel-hydrogen battery type HR 23S are presented. The results obtained for the nickel-cadmium battery type VO 23S are similar except that the voltage level and the charge conservation characteristics vary significantly. The electrical and thermal characteristics permit predictions of the following optimal applications: charge coefficient in the order of 1.3 to 1.4 at 20C; charge current density higher than C/10 at 20C; discharge current density from C/10 to C/3 at 20C; maximum discharge temperature: OC; storage temperature: -20C.

Billard, J. M.↗