Search NASA⌕ Search

SEARCH · Search NASA

Results for “discriminant analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multivariate data analysis approach to understand magnetic properties of perovskite manganese oxides

Here we apply statistical multivariate data analysis techniques to obtain some insights into the complex structure-property relations in antiferromagnetic (AFM) and ferromagnetic (FM) manganese perovskite systems, AMnO{sub 3}. The 131 samples included in the present analyses are described by 21 crystal-structure or crystal-chemical (CS/CC) parameters. Principal component analysis (PCA), carried out separately for the AFM and FM compounds, is used to model and evaluate the various relationships among the magnetic properties and the various CS/CC parameters. Moreover, for the AFM compounds, PLS (partial least squares projections to latent structures) analysis is performed so as to predict the magnitude of the Neel temperature on the bases of the CS/CC parameters. Finally, so-called PLS-DA (PLS discriminant analysis) method is employed to find out the most influential/characteristic CS/CC parameters that differentiate the two classes of compounds from each other. - Graphical abstract: Statistical multivariate data analysis techniques are applied to detect structure-property relations in antiferromagnetic (AFM) and ferromagnetic (FM) manganese perovskites. For AFM compounds, partial least squares projections to latent structures analysis predict the magnitude of the Neel temperature on the bases of structural parameters only. Moreover, AFM and FM compounds are well separated by means of so-called partial least squares discriminant analysis method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

What are the best radar wavelengths, incidence angles and polarizations for geologic applications? A statistical approach

Linear discriminant analysis of multifrequency and multipolarization radar scatterometer data of lava flows and sedimentary rocks indicates that the lava flows can be separated by age and the sedimentary rocks can be discriminated from one another. The optimum wavelengths, polarizations and incidence angles among those available for these problems was determined by the discriminant analysis program. For separation of the lava flows, shorter wavelengths, smaller incidence angles and horizontal polarization are best. A SIR-C radar configuration could provide nearly complete discrimination of these lava flows. Conversely, the longer wavelengths, larger incidence angles and vertical polarization was preferred for sedimentary rocks, perhaps due to the slight vegetation cover. Satisfactory classification of sedimentary rocks requires more radar data than for the lavas. These results are potentially useful both for radar system configuration and for geological applications. The method developed here may provide a rationale for user specification of imaging system parameters.

Blom, R.↗

Source Attribution of Cyanides using Anionic Impurity Profiling, Stable Isotope Ratios, Trace Elemental Analysis and Chemometrics

Chemical attribution signatures (CAS) for chemical threat agents (CTAs) are being investigated to provide an evidentiary link between CTAs and specific sources to support criminal investigations and prosecutions. In a previous study, anionic impurity profiles developed using high performance ion chromatography (HPIC) were demonstrated as CAS for matching samples from eight potassium cyanide (KCN) stocks to their reported countries of origin. Herein, a larger number of solid KCN stocks (n = 13) and, for the first time, solid sodium cyanide (NaCN) stocks (n = 15) were examined to determine what additional sourcing information can be obtained through anion, carbon stable isotope, and elemental analyses of cyanide stocks by HPIC, isotope ratio mass spectrometry (IRMS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), respectively. The HPIC anion data was evaluated using the variable selection methods of Fisher-ratio (F-ratio), interval partial least squares (iPLS), and genetic algorithm-based partial least squares (GAPLS) and the classification methods of partial least squares discriminate analysis (PLSDA), K nearest neighbors (KNN), and support vector machines discriminate analysis (SVMDA). In summary, hierarchical cluster analysis (HCA) of anion impurity profiles from multiple cyanide stocks from six reported country of origins resulted in cyanide samples clustering into three groups: Czech Republic, Germany, and United States, independent of the associated alkali metal (K or Na). The three country groups were independently corroborated by HCA of cyanide elemental profiles and corresponded to countries with known solid cyanide factories. Both the anion and elemental CAS are believed to originate from the aqueous alkali hydroxides used in cyanide manufacture. Carbon stable isotope measurements resulted in two clusters: Germany and United States (the single Czech stock grouped with United States stocks). The carbon isotope CAS is believed to originate from the carbon source and process used to make the HCN utilized in cyanide synthesis. Classification errors for two validation studies using anion impurity profiles collected over five years on different instruments were as low as zero for KNN and SVMDA, demonstrating the excellent reliability (so far) of using anion impurities for matching a cyanide sample to its country of manufacture (i.e., factory). Variable selection reduced errors for those classification methods having errors greater than zero with iPLS-forward selection, and F-ratio typically providing the lowest errors. Finally, using anion profiles to match cyanides to a specific stock or stock group resulted in cross-validation errors ranging from zero to 5.3%.

chemical forensics↗

Geologic mapping using LANDSAT data

The feasibility of automated classification for lithologic mapping with LANDSAT digital data was evaluated using three classification algorithms. The two supervised algorithms analyzed, a linear discriminant analysis algorithm and a hybrid algorithm which incorporated the Parallelepiped algorithm and the Bayesian maximum likelihood function, were comparable in terms of accuracy; however, classification was only 50 per cent accurate. The linear discriminant analysis algorithm was three times as efficient as the hybrid approach. The unsupervised classification technique, which incorporated the CLUS algorithm, delineated the major lithologic boundaries and, in general, correctly classified the most prominent geologic units. The unsupervised algorithm was not as efficient nor as accurate as the supervised algorithms. Analysis of spectral data for the lithologic units in the 0.4 to 2.5 microns region indicated that a greater separability of the spectral signatures could be obtained using wavelength bands outside the region sensed by LANDSAT.

Siegal, B. S.↗

Multisensor classification of sedimentary rocks

A comparison is made between linear discriminant analysis and supervised classification results based on signatures from the Landsat TM, the Thermal Infrared Multispectral Scanner (TIMS), and airborne SAR, alone and combined into extended spectral signatures for seven sedimentary rock units exposed on the margin of the Wind River Basin, Wyoming. Results from a linear discriminant analysis showed that training-area classification accuracies based on the multisensor data were improved an average of 15 percent over TM alone, 24 percent over TIMS alone, and 46 percent over SAR alone, with similar improvement resulting when supervised multisensor classification maps were compared to supervised, individual sensor classification maps. When training area signatures were used to map spectrally similar materials in an adjacent area, the average classification accuracy improved 19 percent using the multisensor data over TM alone, 2 percent over TIMS alone, and 11 percent over SAR alone. It is concluded that certain sedimentary lithologies may be accurately mapped using a single sensor, but classification of a variety of rock types can be improved using multisensor data sets that are sensitive to different characteristics such as mineralogy and surface roughness.

Evans, Diane↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multivariate analysis of gamma spectra to characterize used nuclear fuel

Abstract—The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in used nuclear fuel reprocessing facilities to support process verification and validation. The MIP Monitor applies multivariate analysis to gamma spectroscopy of reprocessing streams in order to detect small changes in the gamma spectrum, which may indicate changes in process conditions. This research extends the MIP Monitor by characterizing a used fuel sample after initial dissolution according to the type of reactor of origin (pressurized or boiling water reactor), initial enrichment, burn up, and cooling time. Simulated gamma spectra were used to develop and test three fuel characterization algorithms. The classification and estimation models employed are based on the partial least squares regression (PLS) algorithm. A PLS discriminate analysis model was developed which perfectly classified reactor type. Locally weighted PLS models were fitted on-the-fly to estimate continuous fuel characteristics. Burn up was predicted within 0.1% root mean squared percent error (RMSPE) and both cooling time and initial enrichment within approximately 2% RMSPE. This automated fuel characterization can be used to independently verify operator declarations of used fuel characteristics and inform the MIP Monitor anomaly detection routines at later stages of the fuel reprocessing stream to improve sensitivity to changes in operational parameters and material diversions.

Multivariate Analysis for Characterization of Used↗

Benchmark data on the separability among crops in the southern San Joaquin Valley of California

Landsat MSS data were input to a discriminant analysis of 21 crops on each of eight dates in 1979 using a total of 4,142 fields in southern Fresno County, California. The 21 crops, which together account for over 70 percent of the agricultural acreage in the southern San Joaquin Valley, were analyzed to quantify the spectral separability, defined as omission error, between all pairs of crops. On each date the fields were segregated into six groups based on the mean value of the MSS7/MSS5 ratio, which is correlated with green biomass. Discriminant analysis was run on each group on each date. The resulting contingency tables offer information that can be profitably used in conjunction with crop calendars to pick the best dates for a classification. The tables show expected percent correct classification and error rates for all the crops. The patterns in the contingency tables show that the percent correct classification for crops generally increases with the amount of greenness in the fields being classified. However, there are exceptions to this general rule, notably grain.

Morse, A.↗

Effect of radiance-to-reflectance transformation and atmosphere removal on maximum likelihood classification accuracy of high-dimensional remote sensing data

Many analysis algorithms for high-dimensional remote sensing data require that the remotely sensed radiance spectra be transformed to approximate reflectance to allow comparison with a library of laboratory reflectance spectra. In maximum likelihood classification, however, the remotely sensed spectra are compared to training samples, thus a transformation to reflectance may or may not be helpful. The effect of several radiance-to-reflectance transformations on maximum likelihood classification accuracy is investigated in this paper. We show that the empirical line approach, LOWTRAN7, flat-field correction, single spectrum method, and internal average reflectance are all non-singular affine transformations, and that non-singular affine transformations have no effect on discriminant analysis feature extraction and maximum likelihood classification accuracy. (An affine transformation is a linear transformation with an optional offset.) Since the Atmosphere Removal Program (ATREM) and the log residue method are not affine transformations, experiments with Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data were conducted to determine the effect of these transformations on maximum likelihood classification accuracy. The average classification accuracy of the data transformed by ATREM and the log residue method was slightly less than the accuracy of the original radiance data. Since the radiance-to-reflectance transformations allow direct comparison of remotely sensed spectra with laboratory reflectance spectra, they can be quite useful in labeling the training samples required by maximum likelihood classification, but these transformations have only a slight effect or no effect at all on discriminant analysis and maximum likelihood classification accuracy.

Hoffbeck, Joseph P.↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

A Ricin Forensic Profiling Approach Based on a Complex Set of Biomarkers

A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant ( Ricinus communis ) cultivars by four different sample preparation methods (PM1 – PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods and robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of a test set of ricin preparations were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved.

Fredriksson, Sten-Åke (ORCID:0000000237131990)↗

A method for the precision mass measurement of the stop quark at the international linear collider.

Many supersymmetric models predict new particles within the reach of the next generation of colliders. For an understanding of the model structure and the mechanism(s) of symmetry breaking, it is important to know the masses of the new particles precisely. In this article the measurement of the mass of the scalar partner of the top quark (stop) at an e{sup +}e{sup -} collider is studied. A relatively light stop is motivated by attempts to explain electroweak baryogenesis and can play an important role in dark matter relic density. A method is presented which makes use of cross-section measurements near the pair-production threshold as well as at higher center-of-mass energies. It is shown that this method not only increases the statistical precision, but also greatly reduces the systematic uncertainties, which can be important. Numerical results are presented, based on a realistic event simulation, for two signal selection strategies: using conventional selection cuts, and using an Iterative Discriminant Analysis (IDA). Our studies indicate that a precision of {Delta}m{tilde t}{sub 1} = 0.42 GeV can be achieved, representing a major improvement over previous studies. While the analysis of stops is particularly challenging due to the possibility of stop hadronization, the general procedure could be applied to the mass measurement of other particles as well. We also comment on the potential of the IDA to discover a stop quark in this scenario, and we revisit the accuracy of the theoretical predictions for the neutralino relic density.

43 PARTICLE ACCELERATORS↗

Differences in fecal microbial metabolites and microbiota of children with autism spectrum disorders

Evidence supporting that gut problems are linked to ASD symptoms has been accumulating both in humans and animal models of ASD. Gut microbes and their metabolites may be linked not only to GI problems but also to ASD behavior symptoms. Despite this high interest, most previous studies have looked mainly at microbial structure, and studies on fecal metabolites are rare in the context of ASD. Thus, we aimed to detect fecal metabolites that may be present at significantly different concentrations between 21 children with ASD and 23 neurotypical children and to investigate its possible link to human gut microbiome. Using NMR spectroscopy and 16S rRNA gene amplicon sequencing, we examined metabolite profiles and microbial compositions in fecal samples, respectively. Of the 59 metabolites detected, isopropanol concentrations were significantly higher in feces of children with ASD after multiple testing corrections. We also observed similar trends of fecal metabolites to previous studies; children with ASD have higher fecal p-cresol and possibly lower GABA concentrations. In addition, Fisher Discriminant Analysis (FDA) with leave-out-validation suggested that a group of metabolites- caprate, nicotinate, glutamine, thymine, and aspartate- may potentially function as a biomarker to separate ASD participants from the neurotypical group (78% sensitivity and 81% specificity). Consistent with our previous Arizona cohort study, we also confirmed lower gut microbial diversity and reduced relative abundances of Prevotella copri in children with ASD. After multiple testing corrections, we also learned that relative abundances of Feacalibacterium prausnitzii and Haemophilus parainfluenzae were lower in feces of children with ASD. Despite a relatively short list of fecal metabolites, the data in this study support that children with ASD have altered metabolite profiles in feces when compared with neurotypical children and warrant further investigation of metabolites in larger cohorts.

Environmental Molecular Sciences Laboratory↗

Metal mixtures in urban and rural populations in the US: The Multi-Ethnic Study of Atherosclerosis and the Strong Heart Study

Background: Natural and anthropogenic sources of metal exposure differ for urban and rural residents. We searched to identify patterns of metal mixtures which could suggest common environmental sources and/or metabolic pathways of different urinary metals, and compared metal-mixtures in two population-based studies from urban/sub-urban and rural/town areas in the US: the Multi-Ethnic Study of Atherosclerosis (MESA) and the Strong Heart Study (SHS). Methods: We studied a random sample of 308 White, Black, Chinese-American, and Hispanic participants in MESA (2000–2002) and 277 American Indian participants in SHS (1998–2003). We used principal component analysis (PCA), cluster analysis (CA), and linear discriminant analysis (LDA) to evaluate nine urinary metals (antimony [Sb], arsenic [As], cadmium [Cd], lead [Pb], molybdenum [Mo], selenium [Se], tungsten [W], uranium [U] and zinc [Zn]). For arsenic, we used the sum of inorganic and methylated species (∑As). Results: All nine urinary metals were higher in SHS compared to MESA participants. PCA and CA revealed the same patterns in SHS, suggesting 4 distinct principal components (PC) or clusters (∑As-U-W, Pb-Sb, Cd-Zn, Mo-Se). In MESA, CA showed 2 large clusters (∑As-Mo-Sb-U-W, Cd-Pb-Se-Zn), while PCA showed 4 PCs (Sb-U-W, Pb-Se-Zn, Cd-Mo, ∑As). LDA indicated that ∑As, U, W, and Zn were the most discriminant variables distinguishing MESA and SHS participants. Conclusions: In SHS, the ∑As-U-W cluster and PC might reflect groundwater contamination in rural areas, and the Cd-Zn cluster and PC could reflect common sources from meat products or metabolic interactions. Among the metals assayed, ∑As, U, W and Zn differed the most between MESA and SHS, possibly reflecting disproportionate exposure from drinking water and perhaps food in rural Native communities compared to urban communities around the US. - Highlights: • We identified and compared environmental sources of urinary metals in MESA and SHS. • ∑As-U-W in SHS may reflect groundwater contamination in rural areas. • Cd-Zn in SHS may reflect common sources from meat products or metabolic interaction. • ∑As, U, W, and Zn differed the most between MESA and SHS participants.

54 ENVIRONMENTAL SCIENCES↗

The association between vaginal microbiota disorders and early missed abortion: A prospective study

Abstract Introduction The objective of this study was to explore the association between disordered vaginal microbiota and missed abortion to ascertain potential causes of missed abortion related to vaginal microbiology. Material and methods This study was a prospective cohort study with a comparison group (reference group). Vaginal secretions from the posterior fornix of women in the early stages of pregnancy were collected in the Xiangya Third Hospital of Central South University in Changsha, Hunan, China, from November 2018 to November 2019. A total of 54 cases of missed abortion (case group) and 50 cases of normal pregnancy requiring induced abortion (reference group) were analyzed. Bacterial DNA was extracted, hybridized with gene‐specific primers, and then detected using a bacterial chip. The composition and relative abundance of vaginal microbiota in the two groups were compared using α‐diversity analysis, β‐diversity analysis, and the linear discriminant analysis effect size method. Results The α‐diversity analysis showed that the Simpson index of the case group was lower than that of the reference group, whereas the Shannon index in the case group was higher. The relative abundance of Firmicutes in the case group (42.52%) was lower than in the reference group (51.03%, p < 0.05), as was the relative abundance of Lactobacillus (case group 16.51%, reference group 23.00%; p < 0.05). Interestingly, levels of Mycoplasma genitalium and Ureaplasma were lower in the case group ( p < 0.05). The relative abundance of Lactobacillus crispatus , Lactobacillus jensenii , and Lactobacillus gasseri was also significantly lower in the case group than in the reference group ( p < 0.05). The pathways enriched in the case group were predominantly related to metabolism, whereas the genetics‐related pathways were predominantly enriched in the reference group. Conclusions Bacteria are more diverse and unevenly distributed in patients with missed abortion. Decreases in the proportion of vaginal Lactobacillus and changes in Lactobacillus species in these patients may increase the chance of genital tract pathogenic bacterial infection. To our knowledge, our study was the first to observe that a decrease of Firmicutes levels in the vaginal microbiota might impair energy metabolism and have an association with missed abortion.

Sun, Dan↗

Radar image processing for rock-type discrimination

Image processing and enhancement techniques for improving the geologic utility of digital satellite radar images are reviewed. Preprocessing techniques such as mean and variance correction on a range or azimuth line by line basis to provide uniformly illuminated swaths, median value filtering for four-look imagery to eliminate speckle, and geometric rectification using a priori elevation data. Examples are presented of application of preprocessing methods to Seasat and Landsat data, and Seasat SAR imagery was coregistered with Landsat imagery to form composite scenes. A polynomial was developed to distort the radar picture to fit the Landsat image of a 90 x 90 km sq grid, using Landsat color ratios with Seasat intensities. Subsequent linear discrimination analysis was employed to discriminate rock types from known areas. Seasat additions to the Landsat data improved rock identification by 7%.

Blom, R. G.↗