Search NASA⌕ Search

SEARCH · Search NASA

Results for “disinfection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assessment of Silver Based Disinfection Technology for CEV and Future US Spacecraft

Silver biocide offers a potential advantage over iodine, the current state-of-the-art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. As such, silver may reduce the overall complexity and mass of future spacecraft potable water systems, particularly those used to support long duration missions. A primary technology gap identified for the use of silver biocide is one of material compatibility. Wetted materials of construction are required to be selected such that silver ion concentrations can be maintained at biocidally effective levels. Preliminary data on silver biocide depletion rates in heritage spacecraft potable water system wetted-materials of construction has been gathered as part of a multi-phase test project aimed at the characterization of silver based biocide technology through: development of preferred materials lists, investigation of silver biocide forms and delivery methods, down-selection of silver biocide technologies, and integrated testing. A 10% - 20% loss in silver ion concentration per day was observed for acid passivated Nitronic 40 tubing with surface area to volume (S/V) ratios of approximately 4.59 cm-1. The Nitronic 40 tubes were tested both with and without biocide pretreatment. Silver biocide depletion was also observed at approximately 0.1% per day for the first 35 days of exposure to acid passivated Inconel 718 coupon, S/V of approximately 0.14 cm-1. Surface analysis by scanning election microscopy (SEM) suggested deposition of silver metal on both test materials. SEM analysis also provided evidence of potential variability in the passivation process for tube configuration of the Nitronic 40 test apparatus. These preliminary results are presented and discussed herein, along with the current project status.

Callahan, Michael R.↗

Antimicrobial-Coated Granules for Disinfecting Water

Methods of preparing antimicrobialcoated granules for disinfecting flowing potable water have been developed. Like the methods reported in the immediately preceding article, these methods involve chemical preparation of substrate surfaces (in this case, the surfaces of granules) to enable attachment of antimicrobial molecules to the surfaces via covalent bonds. A variety of granular materials have been coated with a variety of antimicrobial agents that include antibiotics, bacteriocins, enzymes, bactericides, and fungicides. When employed in packed beds in flowing water, these antimicrobial-coated granules have been proven effective against gram-positive bacteria, gram-negative bacteria, fungi, and viruses. Composite beds, consisting of multiple layers containing different granular antimicrobial media, have proven particularly effective against a broad spectrum of microorganisms. These media have also proven effective in enhancing or potentiating the biocidal effects of in-line iodinated resins and of very low levels of dissolved elemental iodine.

Akse, James R.↗

Disinfection of Spacecraft Potable Water Systems by Passivation with Ionic Silver

Microbial growth is common on wetted surfaces in spacecraft environmental control and life support systems despite the use of chemical and physical disinfection methods. Advanced control technologies are needed to limit microorganisms and increase the reliability of life support systems required for long-duration human missions. Silver ions and compounds are widely used as antimicrobial agents for medical applications and continue to be used as a residual biocide in some spacecraft water systems. The National Aeronautics and Space Administration (NASA) has identified silver fluoride for use in the potable water system on the next generation spacecraft. Due to ionic interactions between silver fluoride in solution and wetted metallic surfaces, ionic silver is rapidly depleted from solution and loses its antimicrobial efficacy over time. This report describes research to prolong the antimicrobial efficacy of ionic silver by maintaining its solubility. Three types of metal coupons (lnconel 718, Stainless Steel 316, and Titanium 6AI-4V) used in spacecraft potable water systems were exposed to either a continuous flow of water amended with 0.4 mg/L ionic silver fluoride or to a static, pre-treatment passivation in 50 mg/L ionic silver fluoride with or without a surface oxidation pre-treatment. Coupons were then challenged in a high-shear, CDC bioreactor (BioSurface Technologies) by exposure to six bacteria previously isolated from spacecraft potable water systems. Continuous exposure to 0.4 mg/L ionic silver over the course of 24 hours during the flow phase resulted in a >7-log reduction. The residual effect of a 24-hour passivation treatment in 50 mg/L of ionic silver resulted in a >3-log reduction, whereas a two-week treatment resulted in a >4-log reduction. Results indicate that 0.4 mg/L ionic silver is an effective biocide against many bacteria and that a prepassivation of metal surfaces with silver can provide additional microbial control.

Birmele, Michele N.↗

Electrochemical Disinfection Feasibility Assessment Materials Evaluation for the International Space Station

The International Space Station (ISS) Program recognizes the risk of microbial contamination in their potable and non-potable water sources. The end of the Space Shuttle Program limited the ability to send up shock kits of biocides in the event of an outbreak. Currently, the United States Orbital Segment water system relies primarily on iodine to mitigate contamination concerns, which has been successful in remediating the small cases of contamination documented. However, a secondary method of disinfection is a necessary investment for future space flight. Over the past year, NASA Johnson Space Center has investigated the development of electrochemically generated systems for use on the ISS. These systems include: hydrogen peroxide, ozone, sodium hypochlorite, and peracetic acid. To use these biocides on deployed water systems, NASA must understand of the effect these biocides have on current ISS materials prior to proceeding forward with possible on-orbit applications. This paper will discuss the material testing that was conducted to assess the effects of the biocides on current ISS materials.

Rodriquez, Branelle↗

Evaluation of Low-Pressure Cold Plasma for Disinfection for ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 10 to 100 Pa were used to optimize plasma parameters to achieve acceptable kill rates for 3 bacteria, Bacillus cereus, E. coli and Bacillus pumulis SAFR-32 and one fungi, Aspergillus niger. These tests were done on produce and metal coupons to simulate medical equipment. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure shows that the bacteria spores have been physically affected, as their size has gotten smaller and the appearance has changed.

Hintze, Paul E.↗

Evaluation of Low-Pressure Cold Plasma for Disinfection of ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 0.10 to 1.0 mbar were used to optimize plasma parameters. Tests were done on produce and metal coupons to simulate medical equipment. Escherichia coli was used as the challenge organism on produce and Bacillus pumilus SAFR-32 was used on metal surfaces. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure show that the bacteria spores have been physically affected, as their size has gotten smaller and their appearance has changed.

Hintze, Paul E.↗

BioMoSS: Biocidal MoS2 for Disinfection of Spacecraft Potable Water Systems

It has been reported in the literature that few-layered, vertically-aligned molybdenum disulfide (FLV-MoS2) can produce biocidal agents for water disinfection with great effectiveness under visible light excitation. The nano-structure, with limited layers and small domain size increases the band gap of the MoS2 in the visible region such that visible light can be used to drive the production of reactive oxygen species (ROS) for biocidal control. This paper will present the BioMoSS (biocidal MoS2) for space applications concept and present initial results of the investigation into turning the FLV-MoS2 into a viable biocidal system.

Delzeit, Lance↗

Plasma-induced inactivation of Staphylococcus aureus biofilms: The role of atomic oxygen and comparison with disinfectants and antibiotics

Microbial biofilms are of critical concern because of their recalcitrance to antimicrobials. Cold atmospheric plasmas (CAP) represent a promising biofilm remediation strategy as they generate reactive oxygen and nitrogen species (RONS), but mechanisms underpinning CAP-biofilm interactions remain unknown. We assess the impact of treatment modality on biofilm inactivation and show that CAP killing of Staphylococcus aureus biofilms is dependent on treatment conditions, including solution chemistry. In dry treatments, biofilms are locally ablated due to plasma-produced O flux. For saline-submerged biofilms, while we show that ClO – is generated at high concentrations in larger treatment volumes, CAP inactivation at low ClO – concentrations implicates other reaction pathways. Finally, we demonstrate CAP efficacy over conventional antimicrobials, underscoring its promise as a biofilm treatment approach.

60 APPLIED LIFE SCIENCES↗

Self-Disinfecting Polymeric Coatings

A novel derivative of a previously-published polymeric material has been synthesized and developed into an easily-sprayable coating. Surface characterization of coatings confirm correct elemental presence, and viral assays reveal quantitative elimination of MS2 bacteriophage and Phi6 bacteriophage, surrogates used for SARS-CoV-2, in as little as 5 minutes upon contact. Furthermore, an N95 mask was dip-coated in the polymer solution and analyzed through microscopy and filtration efficacy testing. Though coating was successful, electrostatic interactions between mask layers and polymer reduced filtration efficacy significantly. As such, we expect the current results of this work to be applicable on non-respiratory PPE and on solid substrates of commonly-touched surfaces for rapid self-decontamination.

59 BASIC BIOLOGICAL SCIENCES↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

Inactivation of Human Coronavirus by FATHHOME’s Dry Sanitizer Device: Rapid and Eco-Friendly Ozone-Based Disinfection of SARS-CoV-2

The pandemic of SARS-CoV-2/COVID-19 was reported in December 2019 in Wuhan, China. Pertaining to its high transmissibility and wide host adaptability, this unique human coronavirus spread across the planet inflicting 115 million people and causing 2.5 million deaths (as of March 3rd, 2021). Limited or negligible pre-existing immunity to multiple SARS-CoV-2 variants has resulted in severe morbidity and mortality worldwide, as well as a record-breaking surge in the use of medical-surgical supplies and personal protective equipment. In response to the global need for effective sterilization techniques, this study evaluated the virucidal efficacy of FATHHOME’s self-contained, ozone-based dry-sanitizing device, by dose and time response assessment. We tested inactivation of human coronavirus, HCoV-OC43, a close genetic model of SARS-CoV-2, on porous (N95 filtering facepiece respirator/FFR) and nonporous (glass) surfaces. We started our assays with 20 ppm-10 min ozone exposure, and effectively reduced 99.8% and 99.9% of virus from glass and N95 FFR surfaces, respectively. Importantly, the virus was completely inactivated, below the detection limit (over 6-log10 reduction) with 25 ppm-15 min ozone exposure on both tested surfaces. As expected, a higher ozone exposure (50 ppm-10 min) resulted in faster inactivation of HCoV-OC43 with 100% inactivation from both the surfaces, with no residual ozone present after completion of the 5-min post exposure recapture cycle and no measurable increase in ambient ozone levels. These results confirmed that FATHHOME’s device is suitable for rapid decontamination of SARS-CoV-2- from worn items, frequently touched items, and PPE including N95 FFRs, face shields, and other personal items. View Full-Text

59 BASIC BIOLOGICAL SCIENCES↗