Self-Organizing Map-Based Resilience Quantification and Resilient Control of Distribution Systems Under Extreme Events

Due to climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution system operators (DSO) to ensure that there is uninterrupted power supply to critical loads in their networks. To embed resilience into DSO's decision-making, resilience needs to be first quantified and then integrated into the system-level optimization. Therefore, this paper first develops a novel self-organizing map (SOM) based method (called SomRes) to quantify the time-varying resilience index of a system that can leverage the powerful classification property of SOMs and removes some of the disadvantages of subjective weight assignment methods. Using SomRes, a resilient resource allocation and operational dispatch algorithm is further developed to enhance system resilience against extreme events by considering the SomRes resilience index directly as the feedback. Here, the proposed resilience quantification approach is benchmarked with a state-of-the-art approach and the efficacy of the proposed resilient dispatch algorithm is demonstrated through several deterministic and statistical case studies on the IEEE 123-bus distribution system. Simulation studies show that the proposed SomRes quantification method is an appropriate indicator of system resilience, and the resilient resource allocation and dispatch strategy can significantly reduce critical load shedding under varying event propagation scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AFECS. Multi-Agent Framework for Experiment Control Systems

AFECS is a pure Java based software framework for designing and implementing distributed control systems. AFECS creates a control system environment as a collection of software agents behaving as finite state machines. These agents can represent real entities, such as hardware devices, software tasks, or control subsystems. A special control oriented ontology language (COOL), based on RDFS (Resource Definition Framework Schema) is provided for control system description as well as for agent communication. AFECS agents can be distributed over a variety of platforms. Agents communicate with their associated physical components using range of communication protocols, including tcl-DP, cMsg (publish-subscribe communication system developed at Jefferson Lab), SNMP (simple network management protocol), EPICS channel access protocol and JDBC.

99 GENERAL AND MISCELLANEOUS↗

Optimal Energy Storage Schedules for Load Leveling and Ramp Rate Control in Distribution Systems

Continued integration of distributed energy resources (DERs) into the grid, such as solar PVs, at a large-scale, contributes into the famous Duck Curve. New DER management algorithms are therefore deemed necessary to alleviate rapid variations within net load profiles of distribution systems. Herein this paper proposes a process to determine the optimal energy storage schedules for leveling the distribution circuit feederhead net load. A series of sensitivity analyses shows how the proposed method can be used to determine the optimal energy storage schedules with different capacities, state of charge requirements, and net load ramp rate limitations.

25 ENERGY STORAGE↗

A New Cryogenic Control System for the Vertical Test Area at Jefferson Lab

The Vertical Test Area at Jefferson Lab, consisting of eight vertical dewars, recently received a major upgrade by replacing the original (1995) cryogenic control system. A new, state-of-the-art, distributed control system (DC S) based on Programmable Logic Controllers (PLCs) was installed and commissioned. The new system increases facility throughput, reliability and cryogenic efficiency, while improving safety. The system employs a touchscreen graphical user interface and a highly redundant architecture on an Ethernet backbone.

Davis, K.↗

Fault diagnosis and fault tolerant control for T-S fuzzy stochastic distribution systems subject to sensor and actuator faults

The problem of fault diagnosis (FD) and fault tolerant control (FTC) for a class of Takagi-Sugeno (T-S) fuzzy stochastic distribution control (SDC) systems subject to sensor and actuator faults is discussed in this paper. First, fuzzy logic models are used to approximate the output probability density function (PDF). Next, an adaptive augmented state/fault diagnosis observer is proposed to estimate the system state, sensor and the actuator faults simultaneously. New expected weights based on the sensor fault estimation information and a PI-type fuzzy feedback fault tolerant (FT) controller are designed to compensate the effect of sensor fault and actuator fault simultaneously. When the sensor fault occurs, the expected objective is redesigned to compensate the sensor fault. Meanwhile, the PI controller can compensate the effect of actuator fault, and the output PDF of the system can still track the desired PDF after the fault occurs. Finally, an example of quality distribution control in chemical reaction process is given to confirm the effectiveness of the algorithm.

42 ENGINEERING↗

Neutron Source Facility Training Simulator Based on EPICS

A plant operator training simulator is developed for training the plant operators as well as for design verification of plant control system (PCS) and plant protection system (PPS) for the Kharkov Institute of Physics and Technology Neutron Source Facility. The simulator provides the operator interface for the whole plant including the sub-critical assembly coolant loop, target coolant loop, secondary coolant loop, and other facility systems. The operator interface is implemented based on Experimental Physics and Industrial Control System (EPICS), which is a comprehensive software development platform for distributed control systems. Since its development at Argonne National Laboratory, it has been widely adopted in the experimental physics community, e.g. for control of accelerator facilities. This work is the first implementation for a nuclear facility. The main parts of the operator interface are the plant control panel and plant protection panel. The development involved implementation of process variable database, sequence logic, and graphical user interface (GUI) for the PCS and PPS utilizing EPICS and related software tools, e.g. sequencer for sequence logic, and control system studio (CSS-BOY) for graphical use interface. For functional verification of the PCS and PPS, a plant model is interfaced, which is a physics-based model of the facility coolant loops implemented as a numerical computer code. The training simulator is tested and demonstrated its effectiveness in various plant operation sequences, e.g. start-up, shut-down, maintenance, and refueling. It was also tested for verification of the plant protection system under various trip conditions.

Park, Young Soo↗

Vacuum system of the cyclotrons in VECC, Kolkata

The vacuum system of the K=130 Room Temperature Cyclotron (RTC) (operational since 1978) has been recently modernized and the same of the K{sub bend}=520 Superconducting Cyclotron (SCC), currently under commissioning, is being deployed for remote monitoring and control. The vacuum system of RTC is designed to achieve and maintain vacuum level of 2 X 10{sup -6} mbar inside 23 m{sup 3} volume of Resonator tank and DEE tank. This has been upgraded by replacing several valves, Freon units, gauges and pumps. The relay based manual control system has been replaced by PLC based automated system. The SCC vacuum system also has an elaborate arrangement comprising of turbo molecular pumping modules with associated isolation valves and characteristic gauges. This paper describes essential elements, typically used to obtain high (1X10{sup -7} mbar) vacuum using rotary pumps, diffusion pumps and cold traps/turbo-molecular pumps and other system components such as valves, gauges and baffles. The supervisory control methodology/scheme of both the vacuum systems, developed in-house using EPICS (Experimental Physics and Industrial Control System), a standard open-source software tool for designing distributed control system, is also elaborated here. (author)

43 PARTICLE ACCELERATORS↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

Cloud-based control for power distribution system

Unique systems, methods, techniques and apparatuses for cloud-based control for power distribution systems are disclosed. One exemplary embodiment is a system comprising a microprocessor-based power management system in operative communication with a plurality of buildings located remotely from the power management system and a plurality of communication interface devices provided at corresponding ones of the plurality of buildings. The power management system is structured to perform a plurality of building unit-specific optimizations, evaluate a net power demand on the electrical power grid, reduce the net power demand on the electrical power grid while minimizing disruption to the resident-defined preference parameters, and transmit to each of the plurality of interface devices the one or more additional control commands corresponding to the specific building at which each interface device is provided.

Feng, Xiaoming↗

An Automated, Disruption-Tolerant Device Authentication and Key Management Framework for Critical Systems

Key management is critical to secure operation. Distributed control systems, such as Supervisory Control and Data Acquisition (SCADA) systems, have unique operational requirements that make conventional key management solutions less effective and burdensome. In this paper a novel Kerberos based framework for automated, disruption-tolerant key management for control system environments is presented. Experimental tests and their results are presented to quantify expected performance overhead of this approach. In addition, Zeek sensor analytics are presented to monitor the health and security of the key management framework operation.

Edgar, Thomas W.↗

An Automated Disruption-Tolerant Key Management Framework for Critical Systems

Key management is critical to secure operation. Distributed control systems, such as Supervisory Control and Data Acquisition (SCADA) systems, have unique operational requirements that make conventional key management solutions less effective and burdensome. This paper presents a novel Kerberos-based framework for automated, disruption-tolerant key management for control system environments. Here, experimental tests and their results are presented to quantify the expected performance overhead of this approach. Additionally, Zeek sensor analytics are presented to aid in monitoring the health and security of the key management framework operation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Survey on stochastic distribution systems: A full probability density function control theory with potential applications

Complex systems seen either in general engineering practice or economics are subjected to ever increased uncertainties that are mostly represented as random variables or parameters, and the characteristics of random variables are represented by their probability density functions (PDFs). Controlling their PDFs means to shape their stochastic distributions and in general it would provide a full treatment for system analysis and operational control and optimization. This leads to the development of stochastic distribution control (SDC) systems theory in the past decades, where the original aim of the controller design is to realize a shape control of the distributions of certain random variables in their PDFs sense for some engineering processes. Indeed, once the PDFs of these random variables or parameters are used to describe their distribution characters, the control task is to obtain control signals so that the output PDFs of stochastic systems are made to follow their target PDFs. The subject of SDC was initially originated for non-Gaussian stochastic control systems design but has found a wide spectrum of applications in general systems in terms of data-driven modeling, analysis, signal processing (filtering), data mining via multivariable statistics, decision-making (optimization) for systems subjected to uncertainties and even in economics. In this context, SDC constitutes an effective primer tool for complex system analysis, control and operational optimizations. In this review paper, a detailed survey of the developments on the research of SDC systems will be made together with their wide spectrum applications and future perspectives.

42 ENGINEERING↗

EPICS-DDS

This paper presents a new extension to EPICS, approaching the Data Distributed Service (DDS) interface based on the Channel Access protocol. DDS is the next generation of middleware industrial standards, bringing a data-centric publish-subscribe paradigm to distributed control systems. In comparison with existing middleware technologies, the data-centric approach is able to provide a consistent consolidated model supporting difference data dissemination scenarios and integrating many important issues, such as quality of service, user-specific data structures, and others. The paper considers different features of the EPICS-DDS layer in the context of the high-level accelerator environment.

43 PARTICLE ACCELERATORS↗

Development and application of FPGA-based logic controller - 357

The control systems of nuclear power plants contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance for analog-based protection systems may be difficult as analog parts become obsolete or hard to obtain. Various studies have been conducted to address this control system hardware obsolescence issue. Those control systems of nuclear power plants have been replaced with modern digital control systems such as the programmable logic controller (PLC) and the distributed control system (DCS). The central processing unit (CPU)- based platforms such as the PLC and the DCS require an operating system (OS) and application software, and thus they might result in a common-cause failure when a problem occurs in the operating system or application software. The field programmable gate array (FPGA) is highlighted as an alternative to the conventional protection or control systems. This paper presents the development of an FPGA-based logic controller (FLC) and a diverse protection system (DPS) with the FLC platform. Protection functions for the DPS were implemented in FPGAs without any CPU or OS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control room consolidation at Hanford tank farms for improved conduct of operation - 15345

Washington River Protection Solutions (WRPS) manages the underground waste storage tanks at the Hanford site in Washington State on behalf of the DOE Office of River Protection. There are 177 tanks distributed among 18 tank farms spread across an area of desert scrub covering about 20 square miles. A single evaporator facility supports the tanks to provide waste reduction activities. Farms and associated equipment, including exhausters, have been operated locally since installation. Upgrades over time introduced limited automation, but using inconsistent platforms, and providing isolated control locations around the farms. However, as the Tank Farms move from maintenance operations to production operations, with increased numbers of waste transfers and evaporator campaigns, and also prepare for integration with the adjacent Hanford Waste Treatment Plant, then operational improvements were planned and are being implemented. Infrastructure improvement projects included upgrades of control systems to a common platform, and installation of a fiber optic based local area network to the majority of farms, which together provided a distributed control system supporting tank farms. This new infrastructure provided the basis to propose consolidation of control and monitoring operations to a single location. More than a single location, the new Central Control Room was to increase effectiveness of operations by providing full status of all activities being performed across the Tank Farms and the Evaporator. The recent addition of productivity e-tools also would provide capability for management, supervisors and operators to make informed decisions regarding facility operations, through custom online applications designed to provide real time information derived from operational data. For example, tracking turnover activities between shifts, and maintaining compliance with limited conditions for operations. The Central Control Room would also have a single supervisor able to effectively manage the status of all assets and processes. The expected benefits of this arrangement include increased operator utility, increased situational awareness, improved response time for upset conditions, improvement in operator environment, and reductions in operating costs. The projected ROI for the Central Control Room when fully operational was projected to be about two years based on reduced costs from freeing up operations staff to perform other work plus the time and material savings realized by operations being performed with increased situational awareness. So the Central Control Room would become a hub for monitoring and controlling facility operations while responding to real time information affecting productivity and performance, from a centralized location customized to a fresh working environment. Over a 14-month period, WRPS developed the concept and engineering, procured over 500 items, modified and installed in renovated building, and completed transition and testing of this new Central Control Room, turning over the initial phase to Operations for 24/7 use in April 2014. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Early implementation of digital upgrades on simulators - 347

An important aspect of successful Nuclear Power Plant (NPP) digital control system upgrade projects is to upgrade the Operator Training Simulator (OTS) or a related Engineering Simulator (ES), prior to installation of the Distributed Control System (DCS) on the plant allowing for early testing of the digital controls/HMI and for early training of the plant operators while maintaining OTS configuration management (i.e. OTS in sync with the plant's current design). Experience has shown that early implementation of digital upgrades on the OTS and/or an ES can reduce plant startup duration (related to digital systems commissioning) and ensure operators are proficient with the new digital systems to ensure safe and reliable plant operation. Including simulators in the design process offers many benefits including early identification of design deficiencies, testing deficiency fixes, developing and validating plant procedures and supporting human factors engineering, to name a few. Implementing digital upgrades on the OTS is also a regulatory requirement driven by the ANSI/ANS-3.5-2009 standard (Nuclear Power Plant Simulators for Use in Operator Training and Examination) if the new DCS affects actions to be taken by the plant operator in the main control room. This paper presents the benefits of implementing digital upgrades on the OTS and/or ES prior to plant implementation. The various simulator implementation strategies (stimulation, emulation, simulation or a hybrid solution) and selection factors are discussed. The paper also covers four (4) case studies demonstrating how digital upgrades can be implemented on simulators. The first case study covers the implementation of a Siemens offgas Programmable Logic Controller (PLC) system on the Enrico Fermi OTS (Michigan). The second case study covers the implementation of a GE main generator excitation system on the Cernavoda OTS (Romania). The third case study covers the implementation of a Siemens main feedwater control system on the Callaway OTS and ES (Missouri). The final case study covers the implementation of the non-safety related and safety related DCS on the Nuclear New Build (NNB) Hongyanhe Phase I dual-purpose OTS/ES (China). (authors)