A Controllable Distributed Energy Resource Transformer-Based Grounding Scheme for Microgrids
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract not provided.
Not provided.
Considerable geographical separation between various phasor measurement unit sensor suites used in the wide-area damping control architecture results in time delays with varying steady-state and stochastic components. The consequences of asymmetric latent sensors used in a standard feedback configuration are presented, indicating that asymmetry of the delay provides not only a previously suspected modification to the argument of the loop transmission function, but also a potentially substantial impact on its modulus. Under particular delay configurations, the controller may experience the introduction of varying crossovers in the loop transmission, resulting in a shifting of control bandwidth and previously unconsidered (in)stability characteristics (e.g., alteration of relative stability margins). With consideration to the theoretical results provided, the optimal sensor location based on delay characteristics is provided. Finally, results of the study indicate that it is most frequently best practice to act on the most current sample in the feedback channel, rather than wait for precise time alignment of the delayed sensor.
Not provided.
The new superconducting Linear Coherent Light Source (LCLS-II) at the SLAC National Accelerator Laboratory will be an upgrade to LCLS, the world’s first hard X-ray free-electron laser. LCLS-II is in an advanced stage of construction with equipment for both Cryoplants as well as more than half of the 37 cryomodules onsite. Jefferson Lab (JLab) is a partner lab responsible for building half of the LCLS-II cryomodules. Hence the Low Energy Recirculation Facility (LERF) at JLab was used to stage and test LCLS-II cryomodules before shipping them to SLAC. LERF was set up to test two cryomodules at a time. LERF used LCLS-II cryogenic controls instrumentation racks, Programmable Logic Controllers (PLC) controls and Experimental Physics and Industrial Control System (EPICS) Input/Output Controllers (IOCs) with the intention to use the LERF setup to check-out and verify cryogenic controls for LCLS-II. The cryogenic controls first utilized at LERF would then be replicated for controlling all 37 cryomodules via an EPICS user interface. This paper discusses the cryogenic controls currently developed for implementation in the LCLS-II project.
Abstract Not Provided
Abstract Not Provided
Abstract not provided
Abstract not provided
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.