Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Observability and Estimation of Distributed Space Systems via Local Information-Exchange Networks

Spacecraft formation flying involves the coordination of states among multiple spacecraft through relative sensing, inter-spacecraft communication, and control. Most existing formation-flying estimation algorithms can only be supported via highly centralized, all-to-all, static relative sensing. New algorithms are proposed that are scalable, modular, and robust to variations in the topology and link characteristics of the formation exchange network. These distributed algorithms rely on a local information exchange network, relaxing the assumptions on existing algorithms. Distributed space systems rely on a signal transmission network among multiple spacecraft for their operation. Control and coordination among multiple spacecraft in a formation is facilitated via a network of relative sensing and interspacecraft communications. Guidance, navigation, and control rely on the sensing network. This network becomes more complex the more spacecraft are added, or as mission requirements become more complex. The observability of a formation state was observed by a set of local observations from a particular node in the formation. Formation observability can be parameterized in terms of the matrices appearing in the formation dynamics and observation matrices. An agreement protocol was used as a mechanism for observing formation states from local measurements. An agreement protocol is essentially an unforced dynamic system whose trajectory is governed by the interconnection geometry and initial condition of each node, with a goal of reaching a common value of interest. The observability of the interconnected system depends on the geometry of the network, as well as the position of the observer relative to the topology. For the first time, critical GN&C (guidance, navigation, and control estimation) subsystems are synthesized by bringing the contribution of the spacecraft information-exchange network to the forefront of algorithmic analysis and design. The result is a formation estimation algorithm that is modular and robust to variations in the topology and link properties of the underlying formation network.

Fathpour, Nanaz↗

Kalman-like estimation for static distributed systems Antenna shape from radiation measurements

This paper advances an approach to the determination of shape of static distributed systems. It also illustrates the application of the approach to the problems of surface diagnosis of large parabolic reflectors. The estimation methods developed combine in an optimal sense the information from an elliptic model of the structure and from measurements of the structural deflection and of the far-field pattern changes due to the structural deformation. The estimators have a predictor-corrector structure, quite similar to that of a Kalman filter. The system model is first used to obtain a predicted estimate. A correction term is then added to the prediction to obtain the final state estimate. The relative weighting between prediction and correction terms is determined by an estimator gain. As in a Kalman filter, the estimator gain can be expressed in terms of the state estimation error covariance.

Rodriguez, G.↗

A Robust Parallel Distributed State Estimation for Large Scale Distribution Systems

The growing need and interest in real-time monitoring of large distribution networks motivated by the rapid population of renewable sources, EVs and etc. demand a computationally efficient state estimation framework. Furthermore, this paper presents an improved computational framework for implementing a robust state estimator using a multi-core processor. The main contribution of the paper is the proposed computational framework along with two partitioning strategies which enable fast and robust state estimation for large scale radial and/or meshed distribution systems. Formulation of the proposed method and its implementation are described in detail. Performance of the estimator is tested by simulations first using a small 84-bus radial distribution system. Then the method’s scalability is demonstrated by simulations on two very large scale distribution networks one configured radially and the other meshed each containing over 12,500 buses.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable/Secure Cooperative Algorithms and Framework for Extremely-high Penetration Solar Integration (SolarExPert) (Final Technical Report)

This SolarExPert project has developed a Sustainable Grid Platform (SGP) with scalable architecture of distributed control and optimization. The SGP consists of the following major functions: 1) an advanced grid architecture with hierarchical and distributed communication and control, combined with the OpenFMB standard and implemented on the Multi-Agent OpenDSS (MA-OpenDSS) platform; 2) an online distributed stochastic optimal power flow; 3) an online distributed system state estimation algorithm; 4) the distributed Volt/VAR optimization and frequency control algorithms; 5) the distributed distribution system restoration strategy. The developed SGP together with advanced functions are tested in 1 million (1M)-node distribution system on the MA-OpenDSS platform. Furthermore, the models and algorithms are tested in 100,000-node system HiL simulation, and also in P-HiL implementation with 100 physical devices. The developed functions haven been validated and tested on the selected actual distribution feeder with the data collected from the field of Maui Meadows in Hawaii. The distributed PV hosting capacities with cooperative Volt/VAR and Volt/VAR/Watt control are estimated and compared to provide recommendations for customers and the utility company.

14 SOLAR ENERGY↗

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Multi-Area Model-Free State Estimation via Distributed Tensor Decomposition

This paper proposes a model-free method for distribution system state estimation based on tensor completion using canonical polyadic decomposition. In particular, we consider a setting where the network is divided into multiple areas. The measured physical quantities at buses located in the same area are processed by an area controller. A third-order tensor is constructed to collect these measured quantities. The measurements are analyzed locally to recover the full state information of the network. A closed-form iterative algorithm based on the alternating direction method of multipliers is developed to obtain the low-rank factors of the whole network state tensor where information exchange happens only between neighboring areas. To demonstrate the efficacy of the developed algorithm, numerical simulations are carried out using an IEEE test system.

alternating direction method of multipliers↗

Robust Distribution State Estimation for Reliable Locational Marginal Pricing under Cyber-Attacks

Here this paper examines the impact of false data injection (FDI) cyber-attacks on distribution system state estimation (DSSE) and the resulting distribution locational marginal price (DLMP) in power markets. Two robust high-breakdown regression estimators, namely S- and MM- estimators, are implemented to provide resistance against FDI attacks targeting measurements and grid topology, creating leverage points. The introduced estimators are compared to the weighted least squares (WLS) with a bad data detection and rejection module (BDD) and the robust Huber M-estimator. The proposed estimators are shown to be effective and compare favorably to both existing Huber M- and the WLS with BDD in the presence of topology FDI attacks. Both the S- and MM-estimators provide good performance in the case of clean and corrupted measurements. Their performance is comparable in this case to the Huber M- and the WLS, followed by a BDD module. The simulation considered a modified distribution IEEE 13 and 34-bus systems where the impact of FDI attack scenarios is shown on the state and the DLMP pricing in the presence of distributed Generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

Distributed Frequency Divider for Power System Bus Frequency Online Estimation Considering Virtual Inertia From DFIGs

In this work, a distributed frequency divider is proposed to estimate power system bus frequency with a limited number of PMUs while considering the inertial contributions from double-fed induction generators (DFIGs). The key idea is to reformulate the original frequency divider by modeling the contributions of DFIGs with inertia emulation and external regional power system through Thevenin equivalents. The distributed frequency divider is general and able to estimate local bus frequencies in a distributed manner. Besides, only the knowledge of the rotor speeds of synchronous generator, boundary bus frequencies and terminal bus frequencies of DFIGs as well as the admittance matrix are required to estimate the frequencies at all buses. This is drastically different from existing approaches that require system observability by PMUs to monitor all bus frequencies. Numerical results carried out on the IEEE 39-bus and modified 118-bus power systems with DFIGs demonstrate and effectiveness and robustness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Adaptive-Importance-Sampling-Enhanced Bayesian Approach for Topology Estimation in an Unbalanced Power Distribution System

The reliable operation of a power distribution system relies on a good prior knowledge of its topology and its system state. Although crucial, due to the lack of direct monitoring devices on the switch statuses, the topology information is often unavailable or outdated for the distribution system operators for real-time applications. Apart from the limited observability of the power distribution system, other challenges are the nonlinearity of the model, the complicated, unbalanced structure of the distribution system, and the scale of the system. To overcome the above challenges, we, in this paper, propose a Bayesian-inference framework that allows us to simultaneously estimate the topology and the state of a three-phase, unbalanced power distribution system. Specifically, by using the very limited number of measurements available that are associated with the forecast load data, we efficiently recover the full Bayesian posterior distributions of the system topology under both normal and outage operation conditions. This is performed through an adaptive importance sampling procedure that greatly alleviates the computational burden of the traditional Monte-Carlo (MC)-sampling-based approach while maintaining a good estimation accuracy. The simulations conducted on the IEEE 123-bus test system and an unbalanced 1282-bus system reveal the excellent performances of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint Topology Identification and State Estimation in Unobservable Distribution Grids

Many distribution system operations (e.g., state estimation, control, fault detection/localization) rely on the assumption that the underlying topology is accurately defined. In general, topology identification is a challenging problem in distribution systems as these systems are unobservable with a very limited number of available measurements. In this paper, we tackle this problem by designing a compressive sensing framework that jointly estimates the systems states and network topology via an integrated mixed integer nonlinear program (MINLP) formulation. Here, two reformulations of the original MINLP problems are investigated. Firstly, in order to remove the nonlinearity in the MINLP formulation, a mixed integer linear programming (MILP) problem that employs auxiliary variables is derived. Furthermore, to achieve a faster solution, convex relaxation of the original formulation is derived. Finally, using a Markovian model for topology changes, prior information about system topology is used to improve topology identification particularly when a limited amount of measurements is available. Simulation results on IEEE 37-bus test feeder and IEEE 123-bus test feeder illustrate the efficiency and scalability of the proposed approaches from both state estimation and topology identification point of view (even with 30% of available data).

42 ENGINEERING↗

OEDI—Solar Grid Integration Data and Analytics Library

As a part of the Open Energy Data Initiative, this effort aims to develop and demonstrate novel distribution state estimation, control optimization, and transient analysis as well as provide access to data, data integration, and mapping information. More specifically, the focus of the effort will be on physics-based distribution system state estimation, hybrid (physics-based and machine learning) distribution optimal power flow, and event detection/analysis for solar integration and analytics. This work will enable reproducible, robust, replicable, and generalizable R&D in simulation and emulation of solar system integration. These test models and datasets will provide an integrated library for developing and testing power system operation technologies. To make the library user-friendly, this project will provide data curation tools such as data translators, mapping scripts and APIs, database schemas and metadata, interfaces and user dashboard, source code for the reference algorithms, description of the use-cases/scenarios, and comprehensive information on all the assumptions.

14 SOLAR ENERGY↗

Joint Matrix Completion and Compressed Sensing for State Estimation in Low-observable Distribution System

Limited measurement availability at the distribution grid presents challenges for state estimation and situational awareness. This paper combines the advantages of two sparsity-based state estimation approaches (matrix completion and compressive sensing) that have been proposed recently to address the challenge of unobservability. The proposed approach exploits both the low rank structure and a suitable transform domain representation to leverage the correlation structure of the spatio-temporal data matrix while incorporating the powerflow constraints of the distribution grid. Simulations are carried out on three phase unbalanced IEEE 37 test system to verify the effectiveness of the proposed approach. The performance results reveal - (1) the superiority over traditional matrix completion and (2) very low state estimation errors for high compression ratios representing very low observability.

Dahale, Shweta↗