Distributed Monitoring and Management of Exascale Systems in the Argo Project
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
The development of active distribution grids requires more accurate and lower computational cost state estimation. In this paper, the authors investigate a decentralized learning-based distribution system state estimation (DSSE) approach for large distribution grids. The proposed approach decomposes the feeder-level DSSE into subarea-level estimation problems that can be solved independently. The proposed method is decentralized pruned physics-aware neural network (D-P2N2). The physical grid topology is used to parsimoniously design the connections between different hidden layers of the D-P2N2. Monte Carlo simulations based on one-year of load consumption data collected from smart meters for a three-phase distribution system power flow are developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares and state-of-the-art learning-based DSSE approaches. Numerical results show that the D-P2N2 outperforms the state-of-the-art methods in terms of estimation accuracy and computational efficiency.
The preliminary data of the environmental control and life support subsystem for a space construction base manufacturing module was reported. A space processing module, which is capable of performing production biological experiments, was chosen as a baseline configuration. The primary assemblies and components considered for use were humidity and temperature control, ventilation fan, cabin fan, water separator, condensate storage, overboard dumping, distribution system, contaminant monitoring, cabin sensors, and fire and smoke detection.
The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..
This report summarizes the activities of this project, which aims at design and testing a scalable, robust, and online framework that provides secure monitoring of photovoltaic generation in the face of potential cyber-attacks.
The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.
Future space explorations will require long term human presence in space. Space environments that provide working and living quarters for manned missions are becoming increasingly larger and more sophisticated. Monitor and control of the space environment subsystems by expert system software, which emulate human reasoning processes, could maintain the health of the subsystems and help reduce the human workload. The autonomous power expert (APEX) system was developed to emulate a human expert's reasoning processes used to diagnose fault conditions in the domain of space power distribution. APEX is a fault detection, isolation, and recovery (FDIR) system, capable of autonomous monitoring and control of the power distribution system. APEX consists of a knowledge base, a data base, an inference engine, and various support and interface software. APEX provides the user with an easy-to-use interactive interface. When a fault is detected, APEX will inform the user of the detection. The user can direct APEX to isolate the probable cause of the fault. Once a fault has been isolated, the user can ask APEX to justify its fault isolation and to recommend actions to correct the fault. APEX implementation and capabilities are discussed.
Artificial intelligence aids engineers and technicians in controlling and monitoring complicated systems. Operations Analyst for Distributed Systems (OPERA) software is developmental suite of expert-system computer programs helping engineers and technicians operating from number of computer workstations to control and monitor spacecraft during prelaunch and launch phases of operation. OPERA designed to serve as consultant to operating engineers and technicians. It preprocesses incoming data, using expertise collected from conglomerate of specialists in design and operation of various parts of system. Driven by menus and mouse-activated commands. Modified versions of OPERA used in chemical-processing plants, factories, banks, and other enterprises in which there are distributed-computer systems including computers that monitor or control other computers.
Neutron flux monitoring system forms an integral part of the design of a Generation IV sodium cooled fast reactor system. Diverse possibilities of detector systems installation have to be investigated with respect to practicality and feasibility according to the detection parameters. In this paper, we demonstrate the feasibility of using self powered neutron detectors as in-core detectors in fast reactors for detecting local change in neutron flux distribution. We show that the gamma contribution from fission products decay in the fuel and activation of structural materials is very small compared to the fission gammas. Thus, it is possible for the in-core SPND signal to follow changes in local neutron flux as they are proportional to each other. This implies that the signal from an in-core SPND can provide dynamic information on the neutron flux perturbations occurring inside the reactor core. (authors)
A user interface to the power distribution expert system for Space Station Freedom is discussed. The importance of features which simplify assessing system status and which minimize navigating through layers of information are examined. Design rationale and implementation choices are also presented. The amalgamation of such design features as message linking arrows, reduced information content screens, high salience anomaly icons, and color choices with failure detection and diagnostic explanation from an expert system is shown to provide an effective status-at-a-glance monitoring system for power distribution. This user interface design offers diagnostic reasoning without compromising the monitoring of current events. The display can convey complex concepts in terms that are clear to its users.
The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.
Efficient management and coordination of distributed energy resources with advanced automation schemes requires accurate distribution system modeling and monitoring. Big data from smart meters and photovoltaic (PV) micro-inverters can be leveraged to calibrate existing utility models. This paper presents computationally efficient distribution system parameter estimation algorithms to improve the accuracy of existing utility feeder radial secondary circuit model parameters. The method is demonstrated using a real utility feeder model with advanced metering infrastructure (AMI) and PV micro-inverters, along with alternative parameter estimation approaches that can be used to improve secondary circuit models when limited measurement data is available. Lastly, the parameter estimation accuracy is demonstrated for both a three-phase test circuit with typical secondary circuit topologies and single-phase secondary circuits in a real mixed-phase test system.
Control of on-orbit operation of a spacecraft requires retention and application of special purpose, often unique, knowledge of equipment and procedures. Real-time distributed expert systems (RTDES) permit a modular approach to a complex application such as on-orbit spacecraft support. One aspect of a human-machine system that lends itself to the application of RTDES is the function of satellite/mission controllers - the next logical step toward the creation of truly autonomous spacecraft systems. This system application is described.
We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.
Rainfall-driven hazards such as landslides, debris flows, and earthen dam failures often arise when water changes the internal strain within sand. This study evaluates the ability of distributed acoustic sensing to monitor these strain changes in real time. We embed a fiber-optic cable in a sand-filled glass cylinder and run controlled dry- and wet-sand experiments to measure how strain develops as water infiltrates, saturates, and drains from the sand. The sensing system detects uneven water movement in dry sand and enables millimeter-scale estimates of infiltration rates, and in wet sand it tracks rising water levels, delayed strain peaks after saturation, and abrupt strain shifts during drainage. These results show that fiber-optic sensing captures subtle strain evolution throughout the full water-sand interaction cycle. The study demonstrates that fiber-optic sensing offers promising potential for real-time and cost-effective monitoring and early warning of rainfall-induced geohazards.
In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.
The increasing distributed and renewable energy resources and controllable devices in distribution systems make fast distribution system state estimation (DSSE) crucial in system monitoring and control. We consider a large multi-phase distribution system and formulate DSSE as a weighted least squares (WLS) problem. We divide the large distribution system into smaller areas of subtree structure, and by jointly exploring the linearized power flow model and the network topology, we propose a gradient-based multi-area algorithm to exactly and efficiently solve the WLS problem. The proposed algorithm enables distributed and parallel computation of the state estimation problem without compromising any performance. Numerical results on a 4,521-node test feeder show that the designed algorithm features fast convergence and accurate estimation results. Comparison with traditional Gauss-Newton method shows that the proposed method has much better performance in distribution systems with a limited amount of reliable measurement. The real-time implementation of the algorithm tracks time-varying system states with high accuracy.