Search NASA⌕ Search

SEARCH · Search NASA

Results for “district heating networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

56 records · Page 4

Exploring for Superhot Geothermal Targets in Magmatic Settings: 2022 Field Campaign at Newberry Volcano

This paper presents preliminary results from a subset of work carried out as part of a multinational research project entitled DErisking Exploration for multiple geothermal Plays in magmatic ENvironments (DEEPEN), supported by the U.S. Department of Energy (DOE) and Geothermica, a joint effort by EU member states and associated countries. The DEEPEN project will develop a customized approach to exploration for supercritical and superhot geothermal plays in magmatic systems, which will be applied to two demonstration sites. This paper summarizes field activities carried out at the U.S. demonstration site, Newberry Volcano in central Oregon. The objective of this work effort is to refine the subsurface model of Newberry Volcano, with special focus on deeper zones including the magmatic plumbing system and other key geologic elements. New data collection included gravity and wideband magnetotelluric (MT) surveys, as well as reinstallation of a seismic network. The National Renewable Energy Laboratory (NREL) and Enthalpion Energy LLC (Enthalpion) worked with the Deschutes National Forest Fort Rock District to use a low ground disturbance method of MT deployment to collect MT data inside the caldera and other restricted areas inside the National Volcanic Monument. This opened these areas to geophysical exploration for the first time in decades. Sites along and adjacent to the south rim of the volcano constituted the primary survey objectives. A team from Lawrence Berkeley National Laboratory (LBNL), the U.S. Geological Survey (USGS), and AltaRock also began the process of reinstalling the seismic network from the AltaRock enhanced geothermal system (EGS) demonstration in anticipation of further development activities at the site. The data ingestion, reduction, and analysis phase of the project is ongoing. We are currently processing the MT and gravity data and are developing a new, highly GPU-accelerated, 3D joint MT and gravity inversion to better localize the south rim/south flank conductive target and better understand its relationship to deep heat, fluid sources, and surface extrusive features. Joint inversions, which have not yet been undertaken at Newberry, will allow us to obtain constraints on the geologic model that cannot be determined from each method in isolation, improving our ability to image key geologic features at depth.

geophysics↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗