Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Monte Carlo Simulation with CAD Interface for Calculation of 3D Maps of Residual Dose (CRADA)

Objective: To develop an easy-to-use software application to predict and mitigate radiation effects in research environment, space instruments, nuclear plants and medical facilities and help nonproliferation and national security efforts. Tech-X will develop standalone software libraries and command-line tools for ( 1) translating CAD into tessellated surfaces and tetrahedral meshes in GDML (for Geant4 and MARS 15), ROOT (for MARS 15) and HDF5 (for compact representation and for the visualization) formats, (2) healing CAD geometries to make them suitable for Monte Carlo simulations; (3) creating uniform and variable Cartesian and cylindrical meshes for detailed scoring; and ( 4) efficient Monte Carlo navigation in CAD geometries. JLAB will finish automation of simulations of residual dose in CAD geometries and integrate Tech-X software into Geant4 and MARS15. Finally, Tech-X will develop a Graphical User Interface to set up and heal CAD geometries, create input files, run and visualize simulations for residual dose. This application will run on local desktops, local and remote clusters and supercomputers and will be made available through public clouds, such as Amazon Web Services.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Exceedance Distance Sensitivity Based on Parametric Uncertainty

Sandia National Laboratories (SNL) collaborated with the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Security and Incident Response (NSIR) and Office of Nuclear Regulatory Research (RES) to investigate the reasonable variability in the estimation of dose exceedance distances. SNL performed calculations using the MACCS code to elucidate the sensitivity of dose exceedance distances to variations in user input parameters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainty Analysis of Inhalation Dose Coefficients for Nuclear Incident Response

This study addressed the need to characterize variability in inhalation dose coefficients due to uncertainties in respiratory tract deposition, systemic biokinetics, and physiological parameters. A Python-based implementation of the International Commission on Radiological Protection Publication 66 Human Respiratory Tract Model was developed called the Radiological Exposure Dose Calculator (REDCAL) to propagate parameter uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

TA-54 Flanged Tritium Waste Container Operations, Radioactive Air Emissions Summary Volume 1: Stack Emissions & Off-Site Dose Consequence

In September 2025, pressure mitigation operations began on the four Flanged Tritium Waste Containers (FTWCs) that had been in storage at Los Alamos National Laboratory (LANL), Technical Area (TA-) 54, Area G, Building 1028. Each FTWC was opened at TA-54 and put into a stable configuration, then containers were moved to LANL’s Weapons Engineering Tritium Facility (WETF) for further processing in preparation for shipment off-site. Over the course of 13 operational days, the project had air emissions of 123 curies of tritium (hydrogen-3). The radiological dose to the hypothetical maximally exposed individual (MEI) member of the public from these emissions was 0.012 millirem. This is well within the limits established by the Environmental Protection Agency (EPA), which allows 10 millirem per year to any member of the public. Naturally occurring background radiation in Northern New Mexico averages about 300-400 millirem per year to residents. This report is intended to briefly summarize operations that took place in September and October 2025, provide documentation of the radionuclide air emissions from these operations, and summarize the off-site dose consequence to the public that resulted from these air emissions. Informal notifications addressing these areas were made via email to the EPA and NMED throughout the project, and summaries of these data were also posted on the LANL external web site 1 for FTWC operations.

54 ENVIRONMENTAL SCIENCES↗

Fitting the RESRAD External Dose Rate Coefficients Model to the FGR 15 Data

FGR15 (Bellamy et al. 2025) lists external dose rate coefficients for radionuclides in soil, water and air. It has five tables of coefficients for contaminated soil; one for radionuclides on the surface of the soil and one each for radionuclides in soil layers of 1 cm, 5 cm, 15 cm and infinite thickness. Each table contains 7512 coefficients, quantifying the external dose rate from each of the 1252 ICRP107 radionuclides, to each of the six reference persons of different ages.

54 ENVIRONMENTAL SCIENCES↗

Residual Dose Rates Analyses from Vent Lines Shield Block on the Target Cart at Spallation Neutron Source

The target carriage supports the mercury target vessel in the Spallation Neutron Source (SNS) in a cantilevered fashion and supplies the liquid mercury flowing to and from the target vessel. The target carriage is designed to move the target vessel into its target monolith position to receive the proton beam and then remove it horizontally back into an adjacent service cell, where the target vessel can be exchanged about 2-3 times per calendar year. At the time of the performed studies, the SNS mercury target can accept a proton beam at 1 GeV energy and 1.4 MW power; however, it will be upgraded to receive 1.3 GeV energy at 2 MW by the end of 2024 year [1]. The cart is practically a shield block on wheels to minimize fluxes and dose rates in the service cell downstream of the carriage. There are vent lines located inside a passage on top of the target carriage, and they are covered by a stepping-up steel shield block (vent lines shield block). Vent lines are permanently attached to the shield block. New vent lines with a different design are going to be installed. These lines are shielded by the new steel block to which the vent lines are attached. The estimate of the residual dose rates from the block after it is extracted from the target carriage is performed to estimate the radiation fields and to decide on the type of storage container to be used.

Popova, Irina I↗

In-situ ion irradiation of a spent UO2 fuel: evolution of fission products and nanograins with radiation dose

This study investigates the behavior of fission gas bubbles, five metal precipitates (5MPs) (Mo, Ru, Rh, Tc, Pd) and nanograins in spent uranium dioxide (UO2) fuel under various ion irradiation doses, temperatures, and flux conditions. Utilizing in-situ ion irradiation and advanced transmission electron microscopy, we analyzed the evolution of fission gas bubbles, 5MPs and nanograins in UO2 samples from the Belgium Reactor 3 (BR-3). Our findings reveal significant shrinkage of fission gas bubbles and 5MPs with increasing irradiation dose, accompanied by a decrease in pair density. The study also reveals nanograin coarsening under irradiation. We demonstrate that ion irradiation induces a homogeneous re-solution process where individual atoms are ejected from bubbles and precipitates, leading to their dissolution and subsequent re-precipitation in the matrix. This study provides critical insights into the dynamic behavior of fission products and nanograins under irradiation, facilitating the development of predictive models and contributing to the optimization of nuclear fuel performance and safety.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗

Radiological Dose Consequence Modeling Parameters for Reactor and Nonreactor Nuclear Facilities

To assure consistency between DOE and NRC safety basis requirements this ECAR documents the DOE basis requirements for dose consequence assessments in accordance with Standard DOE-STD-3009-2014. The methodology in this ECAR outlines parameters for evaluating airborne radiological releases and provides a consistent basis for assessing current and future DOE NE facilities.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CFD Simulation of the Dosing Behavior within the Atomic Layer Deposition Feeding System

The effective operation of atomic layer deposition (ALD) feeding system is the premise of realizing specific ALD processes. In the present work, a detailed computational fluid dynamics (CFD) model of the feeding system has been developed and validated, which accounts for the roles of ALD valves and manifolds. A numerical simulation of the compressible fluid flow and heat/mass transfer within the feeding system was conducted. The dosing amounts and the spatiotemporal distributions of the precursors can be accurately predicted using the CFD model, as validated by experimental results. Different precursors, operating conditions, and structures of the feeding system were simulated and analyzed to examine the operating flexibility of the feeding system. The simulation results can be adopted as the upstream boundary conditions for simulations of the ALD process in the reaction chamber. The substrate-scale simulation indicates that the effect of the feeding system on the film deposition is highly related to the surface kinetics of ALD. The present work can serve as a guide for the development and optimization of different ALD-based processes via proper operation and even the design of the feeding system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards Mitigating Electron Beam-Induced Damage in MOFs Using Low Dose Electron Microscopy for In-Situ Room-Temperature Measurements

Metal-Organic Frameworks (MOFs) have emerged as a versatile class of materials with applications in gas storage and separation, catalysis, and drug delivery [1]. Understanding their damage mechanisms in under various environmental conditions is crucial for optimizing performance and stability [2]. This study employs a combination of Length Structural Coherence (LSC) analysis in electron scattering and Electron Energy Loss Spectroscopy (EELS) to elucidate the damage mechanisms in two representative MOFs. MIL101(Fe), and MIL101(Cr). Here, the primary objective is to reveal structural and chemical changes that occur under electron beam irradiation in Scanning Transmission Electron Microscopy (STEM), both in the pristine state and during in-situ CO and CO 2 adsorption. By combining LSC in Radial Distribution Function (RDF) analysis with EELS, comprehensive insights into the nanoscale alterations are obtained and correlated to the electron dose rate.

dos Santos, Gabriel T. [Northwestern University, E↗

Evaluating the impact of anatomical and physiological variability on human equivalent doses using PBPK models

Abstract Addressing human anatomical and physiological variability is a crucial component of human health risk assessment of chemicals. Experts have recommended probabilistic chemical risk assessment paradigms in which distributional adjustment factors are used to account for various sources of uncertainty and variability, including variability in the pharmacokinetic behavior of a given substance in different humans. In practice, convenient assumptions about the distribution forms of adjustment factors and human equivalent doses (HEDs) are often used. Parameters such as tissue volumes and blood flows are likewise often assumed to be lognormally or normally distributed without evaluating empirical data for consistency with these forms. In this work, we performed dosimetric extrapolations using physiologically based pharmacokinetic (PBPK) models for dichloromethane (DCM) and chloroform that incorporate uncertainty and variability to determine if the HEDs associated with such extrapolations are approximately lognormal and how they depend on the underlying distribution shapes chosen to represent model parameters. We accounted for uncertainty and variability in PBPK model parameters by randomly drawing their values from a variety of distribution types. We then performed reverse dosimetry to calculate HEDs based on animal points of departure for each set of sampled parameters. Corresponding samples of HEDs were tested to determine the impact of input parameter distributions on their central tendencies, extreme percentiles, and degree of conformance to lognormality. This work demonstrates that the measurable attributes of human variability should be considered more carefully and that generalized assumptions about parameter distribution shapes may lead to inaccurate estimates of extreme percentiles of HEDs.

Toxicology↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Revealing the electronic structure of van der Waals antiferromagnetic NiPS 3 through synchrotron-based 𝜇-ARPES and alkali metal dosing

Antiferromagnetic NiPS 3 has recently emerged as a quantum material of considerable interest, thanks to the discovery of multiple new couplings involving electrons, spins, orbitals, phonons, and magnons. However, controversies and open questions persist concerning the fundamental origins of these couplings. A critical piece of information required to advance the understanding is the precise electronic band structure of NiPS 3 . Angle-resolved photoemission spectroscopy (ARPES), combined with alkali metal dosing (AMD), can enable us to directly observe the subtle electronic states that appear around the Fermi surface, offering valuable insights into the intriguing quantum properties and interplays of the examined material. Here, in this study, we present a comprehensive characterization and analysis of the band structure of van der Waals layered antiferromagnet NiPS 3 , leveraging state-of-the-art μ-ARPES measurements supported by density functional theory (DFT) calculations. Theoretical DFT results identify the orbital contributions to the observed bands, providing a precise understanding of the experimental ARPES data. Crucially, AMD enables the observation of conduction band and defect-related states above the valence band maximum in NiPS 3 . Furthermore, temperature dependent ARPES results across the Néel transition temperature of NiPS 3 reveal that the paramagnetic and antiferromagnetic phases have nearly identical band structures, underlining the highly localized character of Ni d states. These findings substantially deepen our understanding of the electronic properties of NiPS 3 and lay a vital foundation for exploring the intriguing quantum phenomena it exhibits.

Cao, Yifeng [Boston Univ., MA (United States); Law↗

Ketone monoester plus high‐dose glucose supplementation before exercise does not affect immediate post‐exercise erythropoietin concentrations versus glucose alone

Abstract The objective of this study was to examine the effect of consuming ketone monoester plus a high dose of carbohydrate from glucose (KE + CHO) on the change in erythropoietin (EPO) concentrations during load carriage exercise compared with carbohydrate (CHO) alone. Using a randomized, crossover design, 12 males consumed KE + CHO (573 mg KE/kg body mass, 110 g glucose) or CHO (110 g glucose) 30 min before 4 miles of self‐paced treadmill exercise (KE + CHO:51 ± 13%, CHO: 52 ± 12% V̇O 2peak ) wearing a weighted vest (30% body mass; 25 ± 3 kg). Blood samples for analysis were obtained under resting fasted conditions before (Baseline) consuming the KE + CHO or CHO supplement and immediately after exercise (Post). βHB increased ( p < 0.05) from Baseline to Post in KE + CHO, with no change in CHO. Glucose and glycerol increased ( p < 0.05) from Baseline to Post in CHO, with no effect of time in KE + CHO. Insulin and lactate increased ( p < 0.05) from Baseline to Post independent of treatment. EPO increased ( p < 0.05) from Baseline to Post in KE + CHO and CHO with no difference between treatments. Although KE + CHO altered βHB, glucose, and glycerol concentrations, results from this study suggest that KE + CHO supplementation before load carriage exercise does not enhance immediate post‐exercise increases in EPO compared with CHO alone.

Howard, Emily E.↗

RADIATION DOSE SIMULATIONS FOR JEFFERSON LAB’S PERMANENT MAGNET RESILIENCY LDRD STUDY

In late 2023, Thomas Jefferson National Accelerator Facil- ity (Jefferson Lab) funded a Laboratory Directed Research and Development (LDRD) grant dedicated to investigating the impact of radiation on permanent magnet materials. This research initiative is specifically geared towards assessing materials slated for use in the CEBAF energy upgrade. The experimental approach involves strategically placing perma- nent magnet samples throughout the accelerator, exposing them to varying radiation doses. The simulation code BD- SIM is used to first validate the data and then to simulate the effects on future higher energy passes to study the degra- dation effects on the permanent magnets. In this paper we present the progress of that work.

Deitrick, K.↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗