Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

$\mathrm{SIM}$-$\mathrm{STEM}$ $\mathrm{Lab}$: Incorporating Compressed Sensing Theory for Fast STEM Simulation

We report recently it has been shown that precise dose control and an increase in the overall acquisition speed of atomic resolution scanning transmission electron microscope (STEM) images can be achieved by acquiring only a small fraction of the pixels in the image experimentally and then reconstructing the full image using an inpainting algorithm. In this paper, we apply the same inpainting approach (a form of compressed sensing) to simulated, sub-sampled atomic resolution STEM images. We find that it is possible to significantly sub-sample the area that is simulated, the number of g-vectors contributing the image, and the number of frozen phonon configurations contributing to the final image while still producing an acceptable fit to a fully sampled simulation. Here we discuss the parameters that we use and how the resulting simulations can be quantifiably compared to the full simulations. As with any Compressed Sensing methodology, care must be taken to ensure that isolated events are not excluded from the process, but the observed increase in simulation speed provides significant opportunities for real time simulations, image classification and analytics to be performed as a supplement to experiments on a microscope to be developed in the future

47 OTHER INSTRUMENTATION↗

Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging

Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.

42 ENGINEERING↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Microstructure Experiments-Enabled MARMOT Simulations of SiC/SiC-based Accident Tolerant Nuclear Fuel System

We have undertaken an experimental-computational project that addresses a few key technology gaps associated with the use of SiC/SiC composites for light water reactor fuel cladding. Two principal endeavors in this project are to assess the irradiation-induced microstructural changes and swelling in SiC/SiC composites, and to characterize and model the porous oxide surface layer (when exposed to steam) along SiC recession that is detrimental to the clad integrity under accident conditions. The project tasks are: (i) ion irradiation and characterization (University of Tennessee, Knoxville), (ii) mechanical tests and analysis (University of South Carolina), (iii) steam exposure tests (Oak Ridge National Laboratory), (iv) electron microscopy and spectroscopic characterization (NC State University), (v) x-ray microscopy and reconstruction (University of South Carolina and NC State University), (vi) phase field modeling and simulations (NC State University and Idaho National Laboratory). The effects of 10 MeV Au ion irradiation at 350°C on the microstructure evolution in SiC/SiC composites are investigated at doses up to 400 displacements per atom (dpa) at the University of Tennessee, Knoxville. Atomic force microscopy and optical profilometry reveal irradiation induced axial and radial shrinkage of the fibers for doses greater than 10 dpa. Based on detailed electron microscopy characterization, the primary cause of the fiber shrinkage is attributed to irradiation-induced loss of carbon packets. Additionally, the multilayer PyC interface is observed to portray high resistance to irradiation damage. The mechanical response and failure mechanisms of un-irradiated samples is also assessed through loading tests and X-ray imaging at the University of South Carolina. Steam exposure tests are performed at the Oak Ridge National Laboratory in a facility that represents a reactor pressure vessel under a loss-of-coolant-accident scenario. The samples that are analyzed methodically in this report are tested for 32/31 hours at 1200°C with a velocity of 0.25 cm/s for the pressures: 0.1 MPa, 0.45 MPa, 0.92 MPa and 1.38 MPa. Scanning/transmission electron microscopy analysis conducted at the NC State University (NCSU) shows that the oxide layer thickness increases with the steam pressure. While the oxide layer is crystalline (α- cristobalite) for the pressures 0.45 MPa, 0.92 MPa and 1.38 MPa, the layer is amorphous at 0.1 MPa. Results from Raman spectroscopy have also confirmed the formation of α-cristobalite phase of SiO₂. The abrupt increase in the integrated Raman intensity ratio between steam pressures 0.1 and 0.45 MPa suggests the onset of accelerated crystallization. Non-destructive three dimensional X-ray microscopy/tomography (XCT) and computational image processing techniques are employed by the University of South Carolina to probe the porous oxidation features on SiC samples at varying pressures. Interestingly, most pores are observed to be located away from the surface as well as the oxide-SiC interface. The average oxide layer thickness assessed from the XCT analysis is seen to be in excellent agreement with the values determined through scanning electron microscopy analysis for the highest pressures where the oxide layer is relatively more uniform. A phase-field model developed by the NC State University and Idaho National Laboratory for simulating oxidation of SiC by steam captures the paralinear kinetics of SiC oxidation with a high degree of fidelity. Results from quasi-one-dimensional and two dimensional simulations show that the pores with oxidizing species lead to a higher volatilization rate. These simulations indicate that the enhanced apparent volatilization rates at higher pressures observed in experiments can be rationalized by the increased volatilization from the pores. The project team has also successfully developed the capability to import images from experiments for realistic evolution of the oxidizing microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Upscaling X-ray nanoimaging to macroscopic specimens

Upscaling X-ray nanoimaging to macroscopic specimens has the potential for providing insights across multiple length scales, but its feasibility has long been an open question. By combining the imaging requirements and existing proof-of-principle examples in large-specimen preparation, data acquisition and reconstruction algorithms, the authors provide imaging time estimates for howX-ray nanoimaging can be scaled to macroscopic specimens. To arrive at this estimate, a phase contrast imaging model that includes plural scattering effects is used to calculate the required exposure and corresponding radiation dose. The coherent X-ray flux anticipated from upcoming diffraction-limited light sources is then considered. This imaging time estimation is in particular applied to the case of the connectomes of whole mouse brains. To image the connectome of the whole mouse brain, electron microscopy connectomics might require years, whereas optimized X-ray microscopy connectomics could reduce this to one week. Furthermore, this analysis points to challenges that need to be overcome (such as increased X-ray detector frame rate) and opportunities that advances in artificial-intelligence-based `smart' scanning might provide. While the technical advances required are daunting, it is shown that X-ray microscopy is indeed potentially applicable to nanoimaging of millimetre- or even centimetre-size specimens.

97 MATHEMATICS AND COMPUTING↗

AI-enabled high-resolution scanning coherent diffraction imaging

Ptychographic imaging is a powerful means of imaging beyond the resolution limits of typical x-ray optics. Capturing recovered images from raw ptychographic data, however, requires the solution of an inverse problem, namely, phase retrieval. Phase retrieval algorithms are computationally expensive, which precludes real-time imaging. In this work, we propose PtychoNN, an approach to solve the ptychography data inversion problem based on a deep convolutional neural network. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. Our results demonstrate the practical application of machine learning to recover high fidelity amplitude and phase contrast images of a real sample hundreds of times faster than current ptychography reconstruction packages. Furthermore, by overcoming the constraints of iterative model-based methods, we can significantly relax sampling constraints on data acquisition while still producing an excellent image of the sample. Besides drastically accelerating acquisition and analysis, this capability has profound implications for the imaging of dose sensitive, dynamic, and extremely voluminous samples.

47 OTHER INSTRUMENTATION↗

Object-space optimization of tomographic reconstructions for additive manufacturing

Volumetric 3D printing motivated by computed axial lithography enables rapid printing of homogeneous parts but requires a high dimensionality gradient-descent optimization to calculate image sets. Here we introduce a new, simpler approach to image-computation that algebraically optimizes a model of the printed object, significantly improving print accuracy of complex parts under imperfect material and optical precision by improving optical dose contrast between the target and surrounding regions. Quality metrics for volumetric printing are defined and shown to be significantly improved by the new algorithm. The approach is extended beyond binary printing to grayscale control of conversion to enable functionally graded materials. The flexibility of the technique is digitally demonstrated with realistic projector point spread functions, printing around occluding structures, printing with restricted angular range, and incorporation of materials chemistry such as inhibition. Finally, simulations show that the method facilitates new printing modalities such as printing into flat, rather than cylindrical packages to extend the applications of volumetric printing.

36 MATERIALS SCIENCE↗

Relaxing Direct Ptychography Sampling Requirements via Parallax Imaging Insights

Direct ptychography enables the retrieval of information encoded in the phase of an electron wave passing through a thin sample by deconvolving the interference effects of a converged probe with known aberrations. Under the weak phase object approximation, this permits the optimal transfer of information using noniterative techniques. However, the achievable resolution of the technique is traditionally limited by the probe step size—setting stringent Nyquist sampling requirements. At the same time, parallax imaging has emerged as a dose-efficient phase technique which relaxes sampling requirements and enables scan-upsampling. Here, we formulate parallax imaging as a quadratic approximation to part of the direct ptychography kernel and use this insight to enable upsampling in direct ptychography. We validate our analytical results numerically using simulated and experimental reconstructions.

direct ptychography, parallax imaging, scan Nyquis↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

The Role of Surface Hydroxyls in Dehydration and Dehydrogenation of Formic Acid on Fe 3 O 4 (001)

Understanding the role of surface structure and hydroxylation in catalytic reactions on metal oxide surfaces is important for developing a mechanistic insight into the complex interface processes. Here, we investigate the reactivity of formic acid on reconstructed Fe 3 O 4 (001) using a combination of X-ray photoelectron spectroscopy, infrared reflection absorption spectroscopy, temperature-programmed reaction spectroscopy, low energy electron diffraction, and electronic structure calculations. We find that formic acid initially dissociates at low temperatures (< 80 K) into bidentate formate and a hydroxyl up to an initial dosed coverage of two HCOOH per Fe 3 O 4 (001) unit cell. At higher temperatures (> 450 K), formate largely decomposes along the dehydration pathway, producing CO and H 2 O, with dehydrogenation to CO 2 being a minority side reaction. As a first step, water formation leads to surface oxygen extraction via the Mars-van Krevelen mechanism. Computational studies reveal formate embedded in oxygen vacancies as a key intermediate in the CO formation mechanism. CO formation proceeds via two reaction pathways with desorption that peaks at 530 K on the hydroxyl-rich surface and 560 K on the hydroxyl-deficient surface. Atomic hydrogen coadsorption experiments and ab initio calculations reveal that the presence of surface hydroxyls reduces the CO formation barrier. Furthermore, these results highlight the complex interactions between substrate and intermediate species occurring during reactions on metal oxide surfaces.

Adsorption↗

Parallel evaluation of alternative skin barrier models and excised human skin for dermal absorption studies in vitro

Skin permeation is a primary consideration in the safety assessment of cosmetic ingredients, topical drugs, and human users handling veterinary medicinal products. While excised human skin (EHS) remains the ‘gold standard’ for in vitro permeation testing (IVPT) studies, unreliable supply and high cost motivate the search for alternative skin barrier models. In this study, a standardized dermal absorption testing protocol was developed to evaluate the suitability of alternative skin barrier models to predict skin absorption in humans. Under this protocol, side-by-side assessments of a commercially available reconstructed human epidermis (RhE) model (EpiDerm-200-X, MatTek), a synthetic barrier membrane (Strat-M, Sigma-Aldrich), and EHS were performed. The skin barrier models were mounted on Franz diffusion cells and the permeation of caffeine, salicylic acid, and testosterone was quantified. Transepidermal water loss (TEWL) and histology of the biological models were also compared. EpiDerm-200-X exhibited native human epidermis-like morphology, including a characteristic stratum corneum, but had an elevated TEWL as compared to EHS. The mean 6 h cumulative permeation of a finite dose (6 nmol/cm2) of caffeine and testosterone was highest in EpiDerm-200-X, followed by EHS and Strat-M. Salicylic acid permeated most in EHS, followed by EpiDerm-200-X and Strat-M. Altogether, evaluating novel alternative skin barrier models in the manner outlined herein has the potential to reduce the time from basic science discovery to regulatory impact.

60 APPLIED LIFE SCIENCES↗

Automatic parameter selection for electron ptychography via Bayesian optimization

Abstract Electron ptychography provides new opportunities to resolve atomic structures with deep sub-angstrom spatial resolution and to study electron-beam sensitive materials with high dose efficiency. In practice, obtaining accurate ptychography images requires simultaneously optimizing multiple parameters that are often selected based on trial-and-error, resulting in low-throughput experiments and preventing wider adoption. Here, we develop an automatic parameter selection framework to circumvent this problem using Bayesian optimization with Gaussian processes. With minimal prior knowledge, the workflow efficiently produces ptychographic reconstructions that are superior to those processed by experienced experts. The method also facilitates better experimental designs by exploring optimized experimental parameters from simulated data.

42 ENGINEERING↗

Growth and characterization of α-Sn thin films on In- and Sb-rich reconstructions of InSb(001)

α-Sn thin films can exhibit a variety of topologically nontrivial phases. Both studying the transitions between these phases and making use of these phases in eventual applications requires good control over the electronic and structural quality of α-Sn thin films. α-Sn growth on InSb often results in out-diffusion of indium, a p-type dopant. By growing α-Sn via molecular beam epitaxy on the Sb-rich c(4×4) surface reconstruction of InSb(001) rather than the In-rich c(8×2), we demonstrate a route to substantially decrease and minimize this indium incorporation. The reduction in indium concentration allows for the study of the surface and bulk Dirac nodes in α-Sn via angle-resolved photoelectron spectroscopy without the common approaches of bulk doping or surface dosing, simplifying topological phase identification. In this study, the lack of indium incorporation is verified in angle-resolved and angle-integrated ultraviolet photoelectron spectroscopy as well as in clear changes in the Hall response.

36 MATERIALS SCIENCE↗

Pulse Radiolysis Investigation of Radicals Derived from Water-Soluble Cyanine Dyes: Implications for Super-resolution Microscopy

Light-induced blinking, an inherent feature of many forms of super-resolution microscopy, has been linked to transient reduction of the fluorescent cyanine dye used as an imaging agent. There is, however, only scant literature information related to one-electron reduced cyanine dyes, especially in an aqueous environment. Here, we examine a small series of cyanine dyes, possessing disparate π-conjugation lengths, under selective reducing or oxidizing conditions. The experiment allows recording of both differential absorption spectra and decay kinetics of the resultant one-electron reduced or oxidized transient species in water. Relative to the ground state, absorption transitions for the various radicals are weak and somewhat broadened but do allow correlation with the π-conjugation length. In all cases, absorption maxima lie to the blue of the main ground-state transition. Under anaerobic conditions, the transient species decay on the microsecond to millisecond time scale, with the mean lifetime depending on molecular structure, radiation dose, and dye concentration. The experimental absorption spectra recorded for the one-electron reduced radicals and the presumed dimer cation radical compare well to spectra obtained from time-dependent density functional theory calculations. Furthermore, the results allow conclusions to be drawn regarding the plausibility of the reduced species being responsible for light-induced blinking in direct stochastic optical reconstruction microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-supervised physics-informed generative networks for phase retrieval from a single X-ray hologram

X-ray phase contrast imaging significantly improves the visualization of structures with weak or uniform absorption, broadening its applications across a wide range of scientific disciplines. Propagation-based phase contrast is particularly suitable for time- or dose-critical in vivo/in situ/operando (tomography) experiments because it requires only a single intensity measurement. However, the phase information of the wave field is lost during the measurement and must be recovered. Conventional algebraic and iterative methods often rely on specific approximations or boundary conditions that may not be met by many samples or experimental setups. In addition, they require manual tuning of reconstruction parameters by experts, making them less adaptable for complex or variable conditions. Here we present a self-learning approach for solving the inverse problem of phase retrieval in the near-field regime of Fresnel theory using a single intensity measurement (hologram). A physics-informed generative adversarial network is employed to reconstruct both the phase and absorbance of the unpropagated wave field in the sample plane from a single hologram. Unlike most state-of-the-art deep learning approaches for phase retrieval, our approach does not require paired, unpaired, or simulated training data. This significantly broadens the applicability of our approach, as acquiring or generating suitable training data remains a major challenge due to the wide variability in sample types and experimental configurations. The algorithm demonstrates robust and consistent performance across diverse imaging conditions and sample types, delivering quantitative, high-quality reconstructions for both simulated data and experimental datasets acquired at beamline P05 at PETRA III (DESY, Hamburg), operated by Helmholtz-Zentrum Hereon. Furthermore, it enables the simultaneous retrieval of both phase and absorption information.

36 MATERIALS SCIENCE↗

Nonmonotonic Band Flattening near the Magic Angle of Twisted Bilayer MoTe 2

Twisted bilayer MoTe 2 (tMoTe 2 ) is an emergent platform for exploring exotic quantum phases driven by the interplay between nontrivial band topology and strong electron correlations. Direct experimental access to its momentum-resolved electronic structure is essential for uncovering the microscopic origins of the correlated topological phases therein. Here, we report angle-resolved photoemission spectroscopy measurements of tMoTe 2 , revealing pronounced twist-angle-dependent band reconstruction shaped by orbital character, interlayer coupling, and moiré potential modulation. Density functional theory captures the qualitative evolution, yet underestimates key energy scales across twist angles, highlighting the importance of electronic correlations. Notably, the hole effective mass at the 𝐾 point exhibits a nonmonotonic dependence on twist angle, peaking near 2°, consistent with band flattening at the magic angle predicted by continuum models. Via electrostatic gating and surface dosing, we further visualize the evolution of electronic structure versus doping, enabling direct observation of the conduction band minimum and confirm tMoTe 2 as a direct band gap semiconductor. These results establish a spectroscopic foundation for modeling and engineering emergent quantum phases in this moiré platform.

2D materials↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗