SEARCH · Search NASA
Results for “duration”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Method to estimate the economy-wide consequences of widespread, long duration electric power interruptions
Not provided.
Investigating long-duration plasma operation with the international multi-machine CICLOP database
Explore the source record for details and available documents.
An Analysis of the Duration and Severity of Power Outages During Weather Events Across U.S. Counties
Explore the source record for details and available documents.
Long-duration quiescent high-β hydrogen plasmas
Explore the source record for details and available documents.
A 13‐Year Record Indicates Differences in the Duration and Depth of Soil Carbon Accrual Among Potential Bioenergy Crops
Six years after replacing a maize/soybean cropping system, perennial grasses miscanthus (Miscanthus × giganteus) and switchgrass (Panicum virgatum), and a 28-species restored prairie increased particulate organic carbon in surface soils without increasing soil organic carbon (SOC). To resolve potential changes in the quantity and distribution of SOC, soils were resampled after seven to thirteen years to measure bulk density, carbon (C) content, and stable C isotopes to a depth of 1 m. SOC stocks increased between 1.75 and 2.5 Mg ha −1 year −1 in all perennial crops between 2008 and 2016 (nine growing seasons). Despite relatively low litter inputs and belowground biomass, the highest rate of SOC accrual was in restored prairie (2.5 Mg ha −1 year −1 ), followed by miscanthus (2.0 Mg ha −1 year −1 ) and switchgrass (1.75 Mg ha −1 year −1 ). The change in SOC in maize/soybean was not significant. After 2016, total SOC decreased in maize/soybean and miscanthus, resulting in slower overall rates of SOC accumulation over the full sampling period for miscanthus (0.8 Mg ha −1 year −1 ). The rate of SOC accumulation was greatest below 50 cm depth for restored prairie and switchgrass but in the top 10 cm for miscanthus. Stable isotope analysis showed 13 C enrichment in all depths of switchgrass soils, an indication of new organic C accumulation, but mixed results in all other crops. Planting perennial crops on land formerly in an annual maize/soybean cropping system can slow or reverse soil carbon losses, with the greatest increases in SOC from species-rich prairie.
An Assessment of Resource Drought Events as Indicators for Long-Duration Energy Storage Needs
This report includes quantitative assessment of energy deficits from prolonged low or no generation from variable energy resources - energy droughts (dunkelflaute). The assessment is done for various regions in North America, Europe, and Australia with contributing authors from those regions.
Leveraging Existing Assets for Long Duration Energy Storage
Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.
Liquid organic hydrogen carriers for long-duration energy storage
Liquid organic hydrogen carrier (LOHC) systems are an excellent alternative to pressurized gas and liquid hydrogen storage technologies due to their high volumetric storage capacities and straightforward adaptation to existing infrastructure. Here, we investigate various molecular and heterogenized Ru, Mn, and Fe catalysts for the reversible (de)hydrogenation of polyols. Mn catalysts, Mn-MACHO(Ph) (1) and Mn-MACHO(iPr)BH 4 (2-BH 4 ) were found to maintain catalytic activity for hydrogen production comparable to the Ru analogs, with greater than 98% conversion of 1,4 butanediol and quantitative hydrogen production. Furthermore, to assess the viability of utilizing heterogenized molecular catalysts for 1,4 butanediol (de)hydrogenation, molecular catalysts, Mn-MACHO(Ph), Ru-MACHO(Ph), and Ru-9, were polymerized to form Mn-MACHO-Poly, Ru-MACHO-Poly, and Ru-9-Poly respectively. These catalysts were then used to assess (de)hydrogenation of polyols, ethylene glycol and 1,4 butanediol. These studies reveal that Ru-MACHO-Poly is an efficient dehydrogenation catalyst with 99% conversion and a hydrogen percent yield of 96%. In addition, Ru-MACHO-Poly is a competent hydrogenation catalyst with approximately 98% conversion back to 1,4 butanediol based on quantitative NMR measurements. Overall, the data suggest these molecular and heterogenized catalysts have potential for practical use in polyalcohol-based LOHC systems.
Rethinking Long-Duration Energy Storage Use Cases
Explore the source record for details and available documents.
Securing a Resilient & Reliable Energy Grid with Long Duration Energy Storage
Explore the source record for details and available documents.
The GRB Intrinsic Duration Distribution Suggests Progenitor Differences at Low and High Redshifts
Explore the source record for details and available documents.
Duration of Highly Pathogenic Avian Influenza Virus and Newcastle Disease Virus Infectivity in Dried Ornithologic Study Skins
Not provided.
Supercritical CO2-Based Power Cycles and Long-Duration Electrical Energy Storage
Long term energy storage using sCO2
EXTENDED DURATION OPERATION OF A PILOT-SCALE SUPERCRITICAL CO2 TEST LOOP
Operating a 1.5 MWth sCO2 test loop fired on solid fuel
Discrete versus continuous: Enhancing battery optimization in capacity expansion models
This study compares two battery modeling approaches for capacity expansion models: discrete-duration and continuous-duration formulations. In the discrete approach, battery duration is fixed, and power capacity is optimized. In the continuous approach, both power and energy capacities are decision variables, allowing storage duration to be optimized endogenously. Although both discrete-duration and continuous-duration battery formulations are used in long-term power system planning models, the literature has provided limited direct, systematic comparisons of their implications within a common modeling framework. To address this gap, this study implements both approaches in the Regional Energy Deployment System (ReEDS TM ) capacity expansion model using two resource adequacy methods, across a range of future system conditions, and with varying battery cost projections. Results show continuous-duration and high-resolution discrete approaches produce similar capacity expansion outcomes. The continuous formulation achieves faster runtimes compared to discrete-duration runs with many discrete-duration options. However, the discrete-duration approach allows users to choose to have limited fidelity for storage duration options, which in some cases can outperform the continuous formulation. The continuous formulation has the lowest overall system costs, indicating its ability to fine-tune storage duration to better meet specific system needs. This study's findings provide a side-by-side evaluation of discrete and continuous battery modeling approaches and offer guidance for improving the representation of real-world systems, flexibility, and computational efficiency for representing energy storage in long-term power system planning models.
Analysis of Historical Power Outages of the United States and the National Risk Index
Several works have been documented in the literature to study the societal effect of power outages and to analyze their correlation with the Social Vulnerability Index (SVI). However, the relationship between National Risk Index (NRI) and power outages is yet to be explored. This work analyzes the NRI indices such as Risk, Expected Annual Loss, Social Vulnerability, and Community Resilience with several resilience metrics such as event duration, impact duration, recovery duration, impact level, impact rate, recovery rate, recovery to impact ratio, and area under the outage curves to see the correlation of NRI indices with the resilience metrics. The results show that NRI indices such as Risk and Expected Annual Loss increase with the increase of event duration, impact duration, and recovery duration. All Other metrics are indifferent to the change in the Risk and EAL ratings. The results also show that there is no strong relationship between all the metrics and community resilience and social vulnerability. This work also performed the sensitivity analysis of the extreme event selection process. This sensitivity analysis reveals that the way of identifying extreme events has a significant impact on the evaluation of the events.
Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power
Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.