Search NASASearch

SEARCH · Search NASA

Results for “efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

271 records · Page 4

High entropy oxides prediction and discovery by the Mixed Enthalpy-Entropy Descriptor

The vast, high-dimensional composition space of high-entropy oxides (HEOs) offers exceptional opportunities for functional materials discovery, yet it also poses a fundamental challenge: the rational and efficient prediction of stable, synthesizable compositions and the corresponding structure–property relationships. Despite growing interest, the field still lacks broadly applicable, physically grounded descriptors capable of navigating various large chemical spaces. Here, we introduce a Mixed Enthalpy–Entropy Descriptor (MEED) that enables rapid, first-principles–based prediction of HEOs synthesizability across diverse chemistries. Using MEED, we perform high-throughput screening of two distinct HEO families: rocksalt oxides and perovskite oxides. The predicted top candidates in each family were experimentally validated. MEED reveals unifying thermodynamic and structural principles governing stability across both chemical compositions and polymorphs, providing mechanistic insight into the formation of high-entropy phases. This work significantly broadens the accessible chemical design space for HEOs and establishes a data-efficient framework for accelerating the discovery of next-generation functional materials.

Yu, Liping [University of Central Florida]

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped

A generative machine learning model for designing metal hydrides applied to hydrogen storage

Developing new metal hydrides is a critical step toward efficient hydrogen storage in carbon-neutral energy systems. However, existing materials databases, such as the Materials Project, contain a limited number of well-characterized hydrides, which constrains the discovery of optimal candidates. This work presents a framework that integrates causal discovery with a lightweight generative machine learning model to generate novel metal hydride candidates that may not exist in current databases. Using a dataset of 450 samples (270 training, 90 validation, and 90 testing), the model generates 1000 candidates. After ranking and filtering, six previously unreported chemical formulas and crystal structures are identified, four of which are validated by density functional theory simulations and show strong potential for future experimental investigation. Overall, the proposed framework provides a scalable and time-efficient approach for expanding hydrogen storage datasets and accelerating materials discovery.

generative model

Accessing the oceanic uranium reserve

The ocean contains a vast reserve of uranium that could satisfy global demand for generations. A newly proposed covalent organic framework utilizes structural asymmetry to increase uptake rates, enabling more efficient oceanic uranium recovery.

Wiechert, Alexander [ORNL]

A Self‐Healing System for Polydicyclopentadiene Thermosets

Self-healing offers promise for addressing structural failures, increasing lifespan, and improving durability in polymeric materials. Implementing self-healing in thermoset polymers faces significant manufacturing challenges, especially due to the elevated temperature requirements of thermoset processing. To introduce self-healing into structural thermosets, the self-healing system must be thermally stable and compatible with the thermoset chemistry. This article demonstrates a self-healing microcapsule-based system stable to frontal polymerization (FP), a rapid and energy-efficient manufacturing process with a self-propagating exothermic reaction (≈200 °C). A thermally latent Grubbs-type complex bearing two N-heterocyclic carbene ligands addresses limitations in conventional G2-based self-healing approaches. Under FP's elevated temperatures, the catalyst remains dormant until activated by a Cu(I) co-reagent, ensuring efficient polymerization of the dicyclopentadiene (DCPD) upon damage to the polyDCPD matrix. The two-part microcapsule system consists of one capsule containing the thermally latent Grubbs-type catalyst dissolved in the solvent, and another capsule containing a Cu(I) coagent blended with liquid DCPD monomer. Using the same chemistry for both matrix fabrication and healing results in strong interfaces as demonstrated by lap-shear tests. In an optimized system, the self-healing system restores the mechanical properties of the tough polyDCPD thermoset. Self-healing efficiencies greater than 90% via tapered double cantilever beam tests are observed.

36 MATERIALS SCIENCE

Role of Fluid and Temperature in Fracture Mechanics and Coupled THMC Processes for Enhanced Geothermal Systems

The ability to sustain high energy extraction efficiency from Enhanced Geothermal Systems (EGS) is affected by the ability to measure, characterize, and predict the effect of different perturbations that arise from fluid injection rates, fluid temperature, and shut-in conditions on existing and stimulated fracture systems throughout a subsurface reservoir’s lifecycle. The difficulty arises from limited knowledge of the interaction of fluid and temperature driven fractures with frictional interfaces that govern local deformation and frictional behavior in the surrounding rock. Thermo-poro-mechanical coupled processes tend to dominate this interaction and strongly affect the permeability and local stress distributions that impact efficiency and prevent optimal stimulation conditions over multi-decadal time frames.

Pyrak-Nolte, Laura [Purdue Univ., West Lafayette,

Photovoltage behaviour of p-Sb 2 S 3 photocathodes for hydrogen evolution: effect of n-In 2 S 3 passivation layers

The 1.76 eV band gap of antimony(iii) sulphide (Sb 2 S 3 ) makes this semiconductor material a promising light absorber for photoelectrochemical water splitting, but scalable fabrication approaches to efficient devices are still lacking. Here we show that compact Sb 2 S 3 films on FTO can be obtained by electrochemical growth from aqueous colloidal sulphur and antimony trichloride solutions, followed by mild annealing. These films can be converted into hydrogen evolution photocathodes after coating with In 2 S 3 passivation layers and the addition of Pt proton reduction co-catalysts. For the first time, vibrating Kelvin probe surface photovoltage (VKP-SPV) spectroscopy is used to observe the carrier dynamics in such photoelectrodes. While the bare Sb 2 S 3 films suffer from high surface recombination rates and poor electron extraction, the In 2 S 3 overlayer is found to raise the photovoltage and cathodic photocurrent density, due to passivation of surface defects and formation of a p–n heterojunction. In thick In 2 S 3 films, these benefits are offset by shading and slow electron transfer. Also, we find that O 2 strongly affects the band bending in the Sb 2 S 3 –air and In 2 S 3 –air junctions and their photovoltage. The optimised devices evolve H 2 at 77.5% Faradaic efficiency and with 0.084% applied bias photon-to-current efficiency (ABPE) at 0.12 V vs. RHE. The low ABPE value is attributed to Sb 2 S 3 sub-bandgap defects visible in SPV spectra, the random orientation of Sb 2 S 3 crystallites in the films, which inhibits charge transport, the absence of crystal facets of Sb 2 S 3 , and a detrimental Schottky junction at the FTO|Sb 2 S 3 interface.

de Araújo, Moisés A. [University of California, Da

Three-chamber electrochemical reactor for selective lithium extraction from brine

Efficient lithium recovery from geothermal brines is crucial for the battery industry. Current electrochemical separation methods struggle with the simultaneous presence of Na + , K + , Mg 2+ , and Ca 2+ because these cations are similar to Li + , making it challenging to separate effectively. We address these challenges with a three-chamber reactor featuring a polymer porous solid electrolyte in the middle layer. This design improves the transference number of Li + (t Li+ ) by 2.1 times compared to the two-chamber reactor and also reduces the chlorine evolution reaction, a common side reaction in electrochemical lithium extraction, to only 6.4% in Faradaic Efficiency. Employing a lithium-ion conductive glass ceramic (LICGC) membrane, the reactor achieved high t Li+ of 97.5% in LiOH production from simulated brine, while the concentrations of Na + K + , Mg 2+ , and Ca 2+ are below the detection limit. Electrochemical experiments and surface analysis elucidated the cation transport mechanism, highlighting the impact of Na + on Li + migration at the LICGC interface.

Science & Technology - Other Topics

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Tensorized Interior Radiative Heat Transfer for a Scalable and Calibrated Building Energy Simulator

Building energy simulation is a critical tool for developing and testing advanced control strategies, such as Reinforcement Learning (RL), to provide demand flexibility and affordable energy costs. The recently introduced Smart Buildings Control Suite (sbsim) provides a lightweight, scalable, and data-calibrated simulation environment based on a 2D finite-difference model. However, the initial model primarily focused on conductive and convective heat transfer, neglecting the significant impact of long-wave radiative heat exchange between interior surfaces. This paper presents a significant extension to the sbsim framework by incorporating a physically-grounded model for interior radiative heat transfer. Our primary contribution is the development and integration of a fully tensorized radiative heat transfer module, which preserves the computational efficiency and scalability of the original simulator. This was achieved by developing a pipeline for view factor calculation, including an algorithm to identify directly seeing surfaces within complex floor plans, and formulating the net radiation equations for efficient execution on modern hardware accelerators. We validate the numerical accuracy of our tensorized implementation by comparing its results against a traditional iterative approach, demonstrating identical outcomes. This enhancement increases the physical fidelity of sbsim, enabling more accurate training of RL agents for building energy optimization.

Ham, Sang woo

Low-Temperature Gold Deposition Improves CdTe Back Contacts

Improved back contacts can benefit CdTe photovoltaics (PV). In this work, Cd(Se,Te) PV absorbers are cooled during Au evaporation to thermally quench a chemical reaction occurring between gold and CdTe and the generation of a reaction product that lowers device efficiency. Reducing substrate temperature enhances PV power conversion efficiency via open-circuit voltage and fill factor increases. X-ray photoelectron spectroscopy (XPS) reveals that lower temperature also reduces chemical perturbations of the CdTe, potentially linking back contact formation to a CdTe degradation product that hinders PV performance. Comparing reaction enthalpy and substrate heating energy shows that back contact formation by sputtering elemental metals onto ZnTe may exhibit a degradation pathway analogous to that of CdTe/Au reported here. Degradation-diminishing contact formation processes are therefore of general interest for optoelectronic devices, and the reduced substrate temperature in this study is one example.

14 SOLAR ENERGY

Physical thickness characterization of the FRIB production targets

The FRIB heavy-ion accelerator, commissioned in 2022, is a leading facility for producing rare isotope beams (RIBs) and exploring nuclei beyond the limits of stability. These RIBs are produced via reactions between stable primary beams and a graphite target. Approximately 20–40% of the primary beam power is deposited in the target, requiring efficient thermal dissipation. Currently, FRIB operates with a primary beam power of up to 20 kW. To enhance thermal dissipation efficiency, a single-slice rotating graphite target with a diameter of approximately 30 cm is employed. The effective target region is a 1 cm-wide outer rim of the graphite disc. To achieve high RIB production rates, the areal thickness variation must be constrained within 2%. This paper presents physical thickness characterizations of FRIB production targets with various nominal thicknesses, measured using a custom-built non-contact thickness measurement apparatus.

Instrumentation for radioactive beams (fragmentati

Oxidant-assisted methane pyrolysis

Adding small amounts of CO 2 or H 2 O to methane pyrolysis boosts hydrogen and carbon yieldsviacyclic catalyst regeneration, enabling efficient low-carbon hydrogen and crystalline carbon production.

Chemistry

Additive‐Free Oxidized Spiro‐MeOTAD Hole Transport Layer Significantly Improves Thermal Solar Cell Stability

Perovskite solar cells are among the most promising new solar technologies, already surpassing polycrystalline silicon solar cell efficiencies. The stability of the highest efficiency devices at elevated temperature is, however, poor. These cells typically use Spiro-MeOTAD as the hole transporting layer. It is generally believed that additives, required for enhancing electrical conductivity and optimizing energy level alignment, are responsible for the reduced stability—inferring that Spiro-MeOTAD based hole transporting layers are intrinsically unstable. Here, a reliable noble metal free synthesis of Spiro-MeOTAD (bis(trifluoromethane)sulfonimide) 4 is presented which is used as the oxidizing agent. No additives are added to the partially oxidized Spiro-MeOTAD hole-transporting layer. Device efficiencies up to 24.2% are achieved. Electrical conductivity is largely developed by the first 1% oxidation. Further oxidation shifts the energy levels away from the vacuum level, which allows tuning of the energy level alignment without the use of additives—contradicting the current understanding of this system. Without additives, devices demonstrate significant improvement in stability at elevated temperatures up to 85 °C under one sun over 1400 h continuous illumination. The remaining degradation is pinpointed to ion migration and reactions in the perovskite layer which may be further suppressed with compositional engineering and adequate ion barrier layers.

14 SOLAR ENERGY

Polynomial-time preparation of low-temperature Gibbs states for two-dimensional toric code

In this work, we propose a polynomial-time algorithm for preparing the Gibbs state of the two-dimensional toric code Hamiltonian at any temperature, starting from any initial state, significantly improving upon prior estimates that suggested exponential scaling with inverse temperature. We prove that fast mixing at low temperature for the two-dimensional toric code can be achieved by augmenting local jump operators with simple global jump operators, which enable efficient transitions between logical sectors. To establish tight lower bounds on the spectral gap, we introduce a new reduction method that eventually maps the problem to estimating the spectral gap of a perturbed graph Laplacian on a stair graph. Our proof also shows that the Lindblad dynamics with a digitally implemented low-temperature local Davies generator is able to efficiently drive the quantum state toward the ground state manifold.

97 MATHEMATICS AND COMPUTING

Large language model-driven database for thermoelectric materials

Thermoelectric materials have the ability to convert waste heat into electricity, offering a valuable solution for energy harvesting. However, their widespread use is hindered by low conversion efficiency, the reliance on expensive rare earth elements, and the environmental and regulatory concerns associated with lead-based materials. A fast and cost-effective way to identify highly efficient thermoelectric materials is through data-driven methods. These approaches rely on robust and comprehensive datasets to train models. Although there are several databases on thermoelectric materials, there is still a need to collect and integrate experimental data from peer-reviewed research articles to capture diverse compositions and properties of materials. Here, in this work, we developed a comprehensive database of 7,123 thermoelectric compounds, containing key information such as chemical composition, structural detail, seebeck coefficient, electrical and thermal conductivity, power factor, and figure of merit (ZT). We used the GPTArticleExtractor workflow, powered by large language models (LLM), to extract and curate data automatically from the scientific literature published in Elsevier journals. This process enabled the creation of a structured database that addresses the challenges of manual data collection. The open access database could stimulate data-driven research and advance thermoelectric material analysis and discovery.

Database