Search NASA⌕ Search

SEARCH · Search NASA

Results for “electret”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

64 records · Page 4

Free-field Calibration of the Pressure Sensitivity of Microphones at Frequencies up to 80 kHz

A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the non-uniformity of the sound field and, as applied here, uses a 1/2 -inch air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that often plague FF measurements. Calibrations were performed on 1/4-inch FF air-condenser, electret, and micro-electromechanical systems (MEMS) microphones in an anechoic chamber. The accuracy of this FF method is estimated by comparing the pressure sensitivity of an air-condenser microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration and is typically 0.3 dB (95% confidence), over the range 2-80 kHz.

Herring, G. C.↗

Collection of Infrasonic Sound From Sources of Military Importance

Extreme Endeavors is collaborating with NASA Langley Research Center (LaRC) in the development, testing and analysis of infrasonic detection system under a Space Act Agreement. Acoustic studies of atmospheric events like convective storms, shear-induced turbulence, acoustic gravity waves, microbursts, hurricanes, and clear air turbulence (CAT) over the past thirty years have established that these events are strong emitters of infrasound. Recently NASA Langley Research Center has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at locations where it was not possible previously, such as a mountain crag, inside a cave or on the battlefield. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Extreme Endeavors will present the findings from field testing using this portable infrasonic detection system. Field testing of the infrasonic detection system was partly funded by Greer Industries and support provided by the West Virginia Division of Natural Resources. The findings from this work illustrate the ability to detect structure and other information about the contents inside the caves. The presentation will describe methodology for utilizing infrasonic to locate and portray underground facilities.

Masterman, Michael↗

Extreme low frequency acoustic measurement system

The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

Shams, Qamar A.↗

Wind Noise Reduction in a Non-Porous Subsurface Windscreen

Measurements of wind noise reduction were conducted on a box-shaped, subsurface windscreen made of closed cell polyurethane foam. The windscreen was installed in the ground with the lid flush with the ground surface. The wind was generated by means of a fan, situated on the ground, and the wind speed was measured at the center of the windscreen lid with an ultrasonic anemometer. The wind speed was controlled by moving the fan to selected distances from the windscreen. The wind noise was measured on a PCB Piezotronics 3†electret microphone. Wind noise spectra were measured with the microphone exposed directly to the wind (atop the windscreen lid) and with the microphone installed inside the windscreen. The difference between the two spectra comprises the wind noise reduction. At wind speeds of 3, 5, and 7 m/s, the wind noise reduction is typically 15 dB over the frequency range of 0.1-20 Hz.

Zuckerwar, Allan J.↗

Extreme Low Frequency Acoustic Measurement System

The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

Shams, Qamar A.↗

ANC of Radiated Sound from a Small UAS Rotor using Virtual Error Sensors

Small unmanned aerial systems (UAS) are becoming increasingly common for private, military, and commercial use, increasing community noise exposure. Reducing the noise produced by UAS could help improve community acceptance. Active noise control (ANC) might be used to attenuate noise produced by UAS, however, traditional ANC systems require a physical sensor in the far-field, which is not feasible. This paper assesses a virtual error sensing (VES) method that eliminates the need for a far-field sensor. This paper describes the proposed VES strategy, and presents numerical simulations and experimental results that highlight the benefits and limitations of the approach. Results for the VES system alone and with an ANC approach are presented and discussed. Experimental testing focused on attenuating the tonal noise produced by one 2-bladed rotor with a tip radius of 11.9 cm. Pressure variations caused by blade rotation were measured in the near and far-field using electret microphones and externally polarized condenser microphones, respectively. The filtered-x least mean squares algorithm was used in conjunction with the VES system to attenuate the far-field response. Experimental results show reductions between 6-13 dB at varying far-field locations and rotation rates.

virtual error sensor↗

The SuperCam remote sensing instrument suite for the Mars 2020 rover mission: A preview

We present that the SuperCam remote sensing instrument suite under development for the National Aeronautics and Space Administration’s (NASA) Mars 2020 rover performs laser-induced breakdown spectroscopy (LIBS), remote Raman spectroscopy, visible and infrared (VISIR) reflectance spectroscopy, acoustic sensing, and high-resolution color imaging. The instrument builds on the successful architecture of the ChemCam instrument, which provides LIBS and panchromatic images on the Curiosity rover, adding remote Raman spectroscopy by frequency doubling the laser and using a gated intensified detector to obtain Raman signals at distances to 12 m. To the visible reflectance spectroscopy used by ChemCam, an acousto-optic tunable filter (AOTF)-based IR spectrometer is added to cover the 1.3–2.6 µm range that contains important mineral signatures. A complementary metal-oxide semiconductor (CMOS) detector provides color (Bayer filter) images at a pixel resolution of 19 µrad and an optical resolution of 30 µrad. Sounds are recorded via a Knowles Electret microphone, which is the same one that was included but not used on two earlier missions. The acoustic signals of the LIBS plasmas will provide information on the hardness of the targets, while other sounds (wind, rover sounds) will also be recorded. The laser, telescope, IR spectrometer, and camera reside on the rover’s mast and are provided by the Centre national d’etudes spatiales (CNES), while the LIBS, Raman, and VIS spectrometers and data processing unit are built by Los Alamos National Laboratory (LANL) and reside in the rover body. A calibration target assembly provided by the University of Valladolid, Spain, resides on the back of the rover. Lastly, the overall mass of the instrument suite is 10.7 kg.

47 OTHER INSTRUMENTATION↗

Comparison of Radon Results in 4- Versus 6-Plex Townhouse Units

In this work, to determine whether there were any significant differences in radon frequency between 4-unit (4-plex) and 6- unit (6-plex) multifamily buildings, an analysis was performed on three different populations of townhouses: one located within an Environmental Protection Agency (EPA) Radon Zone 1 site (Population A) and two others, both located in an EPA Radon Zone 3 site (Populations B and C). Within their respective population grouping, all units were two stories, identical in construction and floor plan, and were constructed by the same contractor over a 1- to 2-year period. In addition, each unit had its own separate, ducted forced-air heat pump. Long-term radon testing was performed using alpha track detectors (ATDs) for a period of 180 days. All detectors were placed in accordance with EPA residential sampling protocols (EPA 402-R-92-003) along the centerline of each unit. Followup testing (short-term, 7-day electret) was performed in all units in which the ATD test results were ≥4 pCi/L, and all elevated results were confirmed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards a better understanding of dielectric barrier discharges in ferroelectrets: Paschen breakdown fields in micrometer sized voids

Charged cellular polypropylene foams (i.e., ferro- or piezoelectrets) demonstrate high piezoelectric activity upon being electrically charged. When an external electric field is applied, dielectric barrier discharges (DBDs) occur, resulting in a separation of charges which are subsequently deposited on dielectric surfaces of internal micrometer sized voids. This deposited space charge is responsible for the piezoelectric activity of the material. Previous studies have indicated charging fields larger than predicted by Townsend's model of Paschen breakdown applied to a multilayered electromechanical model; a discrepancy which prompted the present study. The actual breakdown fields for micrometer sized voids were determined by constructing single cell voids using polypropylene spacers with heights ranging from 8 to 75 μm, “sandwiched” between two polypropylene dielectric barriers and glass slides with semi-transparent electrodes. Subsequently, a bipolar triangular charging waveform with a peak voltage of 6 kV was applied to the samples. The breakdown fields were determined by monitoring the emission of light due to the onset of DBDs using an electron multiplying CCD camera. The breakdown fields at absolute pressures from 101 to 251 kPa were found to be in good agreement with the standard Paschen curves. Additionally, the magnitude of the light emission was found to scale linearly with the amount of gas, i.e., the height of the voids. Emissions were homogeneous over the observed regions of the voids for voids with heights of 25 μm or less and increasingly inhomogeneous for void heights greater than 40 μm at high electric fields.

36 MATERIALS SCIENCE↗

Vibration-based energy harvesting with stacked piezoelectrets

Vibration-based energy harvesters with multi-layer piezoelectrets (ferroelectrets) are presented. Using a simple setup with nine layers and a seismic mass of 8 g, it is possible to generate a power up to 1.3 µW at 140 Hz with an input acceleration of 1g. With better coupling between seismic mass and piezoelectret, and thus reduced damping, the power output of a single-layer system is increased to 5 µW at 700 Hz. Simulations indicate that for such improved setups with 10-layer stacks, utilizing seismic masses of 80 g, power levels of 0.1 to 1 mW can be expected below 100 Hz.

36 MATERIALS SCIENCE↗