Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric resistance heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Temperature-induced valence-state transition in double perovskite Ba 2 - x Sr x TbIrO 6

In this paper, a temperature-induced valence-state transition is studied in a narrow composition range 0.2 ≤ x ≤ 0.375 of Ba 2 - x Sr x TbIrO 6 by means of x-ray and neutron powder diffraction, resonant inelastic x-ray scattering, magnetic susceptibility, electrical resistivity, and specific heat measurements. The valence-state transition involves an electron transfer between Tb and Ir leading to the valence-state change between Tb 3 + / Ir 5 + and Tb 4 + / Ir 4 + phases. This first-order transition has a dramatic effect on the lattice, transport properties, and the long-range magnetic order at low temperatures for both Tb and Ir ions. Ir 5 + ion has an electronic configuration of 5 d 4 ( J eff = 0 ), which is expected to be nonmagnetic. In contrast, Ir 4 + ion with a configuration of 5 d 5 ( J eff = 1/2) favors a long-range magnetic order. For x = 0.1 with Tb 3 + / Ir 5 + configuration to the lowest temperature (2 K) investigated in this paper, a spin-glass behavior is observed around 5 K indicating Ir 5 + ( J eff = 0 ) ions act as a spacer reducing the magnetic interactions between Tb 3 + ions. For x = 0.5 with Tb 4 + / Ir 4 + configuration below the highest temperature 400 K of this paper, a long-range antiferromagnetic order at T N = 40 K is observed highlighting the importance of Ir 4 + ( J eff = 1/2) ions in promoting the long-range magnetic order of both Tb and Ir ions. For 0.2 ≤ x ≤ 0.375, a temperature-induced valence-state transition from high-temperature Tb 3 + / Ir 5 + phase to low-temperature Tb 4 + / Ir 4 + phase occurs in the temperature range 180 K ≤ T ≤ 325 K and the transition temperature increases with x . The compositional dependence demonstrates the ability to tune the the valence state for a critical region of x that leads to a concurrent change in magnetism and structure. Furthermore, this tuning ability could be employed with suitable strain in thin films to act as a switch as the magnetism is manipulated.

36 MATERIALS SCIENCE↗

Magnetic order in the S eff =1/2 triangular-lattice compound NdCd 3 ⁢P 3

Here, we present and characterize a new member of the R⁢Cd 3 ⁢P 3 (R=rare earth) family of materials, NdCd 3 ⁢P 3 , which possesses Nd 3+ cations arranged on well-separated triangular lattice layers. Magnetic susceptibility and heat capacity measurements demonstrate a likely S eff =1/2 ground state, and also reveal the formation of long-range antiferromagnetic order at T N =0.34K. Via measurements of magnetization, heat capacity, and electrical resistivity, we characterize the electronic properties of NdCd 3 ⁢P 3 and compare results to density functional theory calculations.

36 MATERIALS SCIENCE↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

Importance of the Heat Treatment Scheme on Self-Reducing Reactive Silver Inks

Self-reducing reactive silver inks can print high-quality silver at reasonable temperatures. While numerous studies have explored the impact of processing temperature on electrical properties, the role of the heat treatment scheme has not yet been studied. Common heat treatment schemes include printing and drying inks at room temperature before heat treatment, performing heat treatments while the inks are still wet, and directly printing the inks onto heated substrates. Each scheme generates distinct heat transfer and mass transport kinetics that can affect the silver morphology and electrical properties. However, to date, the impact of different schemes has not been systematically investigated. To address this knowledge gap, this work investigates how different heat treatment schemes impact metal formation, sintering, and the resultant electrical properties of printed self-reducing reactive silver inks. Heat treatment on room-temperature dried inks and wet inks, with top-down (oven) and bottom-up (hot plate) heating sources, were compared. Inks dried at room temperature resulted in extremely porous films that required high heat treatment temperatures (>100 °C) for silver densification. However, these dried films could only densify locally, and their high initial porosities resulted in voids and high resistances (~0.6 Ω mm –1 ) even after heat treatments above 300 °C. Inks that were wet during heat treatment showed moderate improvements in electrical properties with resistances on the order of 0.4 Ω mm –1 at heat treatments of 250 °C. Printing reactive inks directly onto heated substrates yielded the best low-temperature results, with 0.46 Ω mm –1 (5.5 × bulk silver) line resistances achieved at only 90 °C. Overall, this work’s experimental results provide detailed insights into why printing onto a heated substrate results in superior electrical performance compared to more common heat treatment schemes. Additionally, controlling where the precipitation reaction occurs is critical to controlling the film morphology and properties. As a result, this work shows that even an ammonia-based silver reactive ink can achieve good, low-temperature electrical properties with the proper heat treatment scheme.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of non-stoichiometry and pressure on superconductivity in topological semimetal PdTe

Research into topological superconductivity has been at the forefront of condensed matter physics due to both fundamental interest and potential applications in quantum computing. PdTe, is such a superconductor with a transition temperature T c ∼ 4.5 K and exhibits a nontrivial topological electronic structure, thus receiving significant attention. We report an experimental and theoretical investigation of the pressure effect on superconductivity by applying chemical non-stoichiometry and hydrostatic pressure. While T c decreases with increasing pressure through electrical resistivity, magnetization, and specific heat measurements, chemical pressure has a distinct impact from hydrostatic pressure, which could increase T c by creating negative pressure via non-stoichiometric Pd x Te with x > 1. Accompanied with this is a sign change of the Hall coefficient from negative at x < 1 to positive at x > 1. This indicates extreme sensitivity of the electronic structure to chemical non-stoichiometry, which occurs as a Pd vacancy for x < 1 and Pd interstitial for x > 1.

nonstoichiometry↗

MgPd 2 Sb : A Mg-based Heusler-type superconductor

Here, we report the synthesis and physical properties of a full Heusler compound, MgPd 2 Sb, which we found to show superconductivity below T c = 2.2 K . MgPd 2 Sb was obtained by a two-step solid-state reaction method and its purity and cubic crystal structure [Fm-3m, a = 6.4523(1) Å ] were confirmed by powder x-ray diffraction. Normal and superconducting states were studied by electrical resistivity, magnetic susceptibility, and heat capacity measurements. The results show that MgPd 2 Sb is a type-II, weak coupling superconductor ( λ e-p = 0.53 ). The observed pressure dependence of T c (ΔT c /p ≈ -0.23 K / GPa ) is one of the strongest reported for a superconducting Heusler compound. The electronic structure, phonons, and electron-phonon coupling in MgPd 2 Sb were theoretically investigated. The obtained results are in agreement with the experiment, confirming the electron-phonon coupling mechanism of superconductivity. We compare the superconducting parameters to those of all reported Heusler-type superconductors.

36 MATERIALS SCIENCE↗

High critical field superconductivity at ambient pressure in MoB 2 stabilized in the P6/mmm structure via Nb substitution

Recently it was discovered that, under elevated pressures, MoB 2 exhibits superconductivity at a critical temperature T c as high as 32 K. The superconductivity appears to develop following a pressure-induced structural transition from the ambient pressure $\text{R}\bar{3}$⁢m structure to an MgB 2 -like P6/mmm structure. This suggests that remarkably high T c values among diborides are not restricted to MgB 2 as previously appeared to be the case, and that similarly high T c values may occur in other diborides if they can be coerced into the MgB 2 structure. In this paper, we show that density functional theory calculations indicate that phonon free energy stabilizes the P6/mmm structure over the $\text{R}\bar{3}$⁢m at high temperatures across the Nb 1–x ⁢Mo x B 2 series. X-ray diffraction confirms that the synthesized Nb-substituted MoB 2 adopts the MgB 2 crystal structure. Finally, high magnetic field electrical resistivity measurements and specific heat measurements demonstrate that Nb x ⁢Mo 1–x⁢ B 2 exhibits superconductivity with T c as high as 8 K and critical fields approaching 6 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing putative orbital differentiation effects via Eu 2+ spin dynamics in Sr 1-x Eu x Fe 2 As 2

Here, in this work, we report x-ray powder diffraction, elemental analysis, electrical resistivity, magnetic susceptibility, specific heat, and electron spin resonance (ESR) in single crystals of Sr 1-x Eu x Fe 2 As 2 . We observed a breakdown of the previously reported scaling between the Eu 2+ Korringa relaxation rate obtained from ESR and the spin density wave temperature evolution for Sr-rich samples. This result suggests a distinct evolution of the orbital differentiation of the Fe 3d bands along the Sr-based series when compared to the Ba counterpart. We argue that this difference is related to a larger splitting between the structural (tetragonal-to-orthorhombic) and the Fe-driven spin density wave transitions induced by Eu doping in this series. In fact, our results indicate that the two transitions follow an opposite x-Eu dependence for Sr-concentrated samples. Our work shows that Sr 1-x Eu x Fe 2 As 2 series and the comparison with their Ba-based counterparts are exciting platforms to be explored for understanding the interplay among orbital differentiation, magnetism, and structural distortions in the iron pnictides

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing quantum criticality in ferromagnetic CeRh 6 Ge 4

CeRh 6 Ge 4 is unusual in that its ferromagnetic transition can be suppressed continuously to zero temperature, i.e., to a ferromagnetic quantum-critical point (QCP), through the application of modest hydrostatic pressure. This discovery has raised the possibility that the ferromagnetic QCP may be of the Kondo-breakdown type characterized by a jump in Fermi volume, to which thermopower S measurements should be sensitive. Further, though S/T changes both sign and magnitude around the critical pressure P c ≈ 0.8 GPa, these changes are not abrupt but extend over a pressure interval from within the ferromagnetic state up to P c . Together with temperature and pressure variations in electrical resistivity and previously reported heat capacity, thermopower results point to the near coincidence of two sequential effects near P c , delocalization of 4f degrees of freedom through orbital-selective hybridization followed by quantum criticality of itinerant ferromagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Efficiency Thermoelectric Clothes Dryer (CRADA Final Report)

A typical clothes dryer in the US accounts for 7% of the average residential customer’s electric bill. Nationwide, consumers pay about $\$$9 billion annually for clothes drying. While energy efficiency for most household appliances has improved by a factor of 2 or more in recent decades, today’s clothes dryers perform similarly to units from the 1970s. Dryer efficiency is measured by the combined energy factor (CEF), with today’s units typically drying 3.73 lb of cloth per kWh consumed. An ENERGY STAR qualified unit must achieve 3.93 lb/kWh (for standard size electric units) and dry in less than 80 minutes. ORNL and CRADA partner Samsung Electronics America have developed an efficient prototype clothes dryer that uses thermoelectric heat pumps instead of electric resistance to dry the clothes. The prototype fabricated at ORNL successfully demonstrated in the laboratory a CEF of 6.89 lb/kWh at standard conditions of 75°F and 50% Relative Humidity (RH), exceeding the original project target of 6.0 lb/kWh. Additional trials on the same prototype achieved faster dry time with slightly lower CEF, meeting all requirements for ENERGY STAR product qualification. Deploying dryers with energy factor of 6 nationwide represents a technical potential of 234 TBtu/yr primary energy savings. The modeling and prototype development activities for the thermoelectric clothes dryer under this CRADA are summarized in this final report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Heat Pumps with Phase Change Thermal Storage: Flexible, Efficient, and Electrification Friendly

As we continue to electrify space- and water-heating, the electricity demand profile of many buildings will change significantly, and periods of high electricity demand will likely not align with renewable energy generation. We expect electricity demands will increase substantially in the winter, annual maximum electricity demands will increase, and more regions will experience annual peak electrical demands – and higher wholesale electricity prices – in the winter. This is especially important for cold climates where 60% of site energy use in buildings is for heating, and where heat pumps perform least efficiently. This paper focuses on one promising solution among the many paths to electrification: the use of phase change materials (PCM) for compact low-cost thermal energy storage (TES). We present the design and simulation of a combi heat pump and phase change thermal storage system used for space- and water-heating in a multifamily residence in a cold climate. To assess the benefits of this technology, we compare its annual performance to that of a current state-of-the-art air-to-air heat pump and separate heat pump water heater. Simulation results for IECC Climate Zone 6A reveal that the combi heat pump with phase change thermal storage can reduce the design size for heat pumps by 40-60%, reduce maximum electric demand by 30-50%, reduce electricity use during 4-12-hour load shed periods by 50%, and avoid the need for auxiliary electric resistance for both space- and water-heating. Tariff structures are highly varied between different utilities and currently reflect higher wholesale market prices for electricity during summer days. Consequently, although this system design provides large electric demand reductions during hypothetical 4-12-hour load shed periods, it does not provide energy cost reductions with current winter residential time-of-use tariffs.

Helmns, Dre↗

Microstructure, electrical resistivity, and tensile properties of neutron-irradiated Cu–Cr–Nb–Zr

High strength, high conductivity copper alloys that can resist creep at high temperatures are one of the primary candidates for efficient heat exchangers in fusion reactors. Cu–Cr–Nb–Zr (CCNZ) alloys, which were designed to improve the strength and creep life of ITER Cu–Cr–Zr (CCZ) reference alloys, have been found to have comparable electrical conductivity and tensile properties to CCZ alloys. The measured creep rupture times for these improved alloys is about ten times higher than the ITER reference alloys at 90–125 MPa at 500 °C. However, the effects of neutron irradiation on these alloys, and the ensuing material properties, have not been studied; thus, their utility in a fusion reactor environment is not well understood. This study characterizes the room temperature mechanical and electrical properties of a neutron-irradiated CCNZ alloy and compares them to a neutron-irradiated ITER reference heat sink CCZ alloy. Tensile specimens were neutron irradiated in the High Flux Isotope Reactor (HFIR) to 5 dpa between 250 °C and 325 °C. Post-irradiation characterization included electrical resistivity measurements, hardness, and tensile tests. Microstructural evaluation used scanning electron microscopy, energy dispersive x-ray spectroscopy, and atom probe tomography to characterize the irradiation-produced changes in the microstructure and investigate the mechanistic processes leading to post-irradiation properties. Transmutation calculations were validated with composition measurements from atom probe data and used to calculate contributions to the increased electrical resistivity measured after irradiation. Comparisons with CCZ alloys in the same irradiation heat found that the post-irradiated CCNZ and CCZ alloys had comparable electrical resistivity. Although CCNZ alloys suffered more irradiation hardening than CCZ, the overall tensile behavior deviated very little from non-irradiated values in the temperature range studied.

36 MATERIALS SCIENCE↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗