Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrochemical sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

2D Graphene Sheets as a Sensing Material for the Electroanalysis of Zileuton

Zileuton (ZLT) is an active oral inhibitor of enzyme 5-lipoxygenase, and long-term intake and overdose of ZLT cause adverse effects, leading to critical conditions in patients. This is a well-recognized issue that necessitates a better approach for ZLT sensing. Given the increasing interest in ZLT sensing and the limitations of previous techniques, there is a need for a highly sensitive, robust, and fast operation method that is inexpensive and easy to use. Thus, for the sensitive detection and determination of ZLT, an electrochemical sensor based on graphene was fabricated. Graphene has excellent properties, such as high surface area, low toxicity, conductivity, and electroactive conjugation with biomolecules, making it suitable for sensing. The electrocatalytic property of graphene promotes the redox-coupled reaction of ZLT. Electrochemical investigation of the modifier was carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). An optimization and analysis of the influence of different parameters on the electrochemical behavior of ZLT were carried out using the CV approach. The scan rate study aided in exploring the physicochemical properties of the electrode process, and two electrons with two protons were found to be involved in the electrooxidation of ZLT. The fabricated sensor showed a wide range of linearity with ZLT, from 0.3 µM to 100.0 µM, and the detection limit was evaluated as 0.03 µM under optimized conditions. The analysis of spiked urine samples, with good recovery values for percent RSD, provided support for the efficiency and applicability of the developed electrode.

2D Material↗

Single‐Atomic Site Catalyst with Heme Enzymes‐Like Active Sites for Electrochemical Sensing of Hydrogen Peroxide

Abstract Heme enzymes, with the pentacoordinate heme iron active sites, possess high catalytic activity and selectivity in biosensing applications. However, they are still subject to limited catalytic stability in the complex environment and high cost for broad applications in electrochemical sensing. It is meaningful to develop a novel substitute that has a similar structure to some heme enzymes and mimics their enzyme activities. One emerging strategy is to design the Fe‐N‐C based single‐atomic site catalysts (SASCs). The obtained atomically dispersed Fe‐N x active sites can mimic the active sites of heme enzymes effectively. In this work, a SASC (Fe‐SASC/NW) is synthesized by doping single iron atoms in polypyrrole (PPy) derived carbon nanowire via a zinc‐atom‐assisted method. The proposed Fe‐SASC/NW shows high heme enzyme‐like catalytic performance for hydrogen peroxide (H 2 O 2 ) with a specific activity of 42.8 U mg −1 . An electrochemical sensor based on Fe‐SASC/NW is developed for the detection of H 2 O 2 . This sensor exhibits a wide detection concentration range from 5.0 × 10 −10 m to 0.5 m and an excellent limit of detection (LOD) of 46.35 × 10 −9 m . Such excellent catalytic activity and electrochemical sensing sensitivity are attributed to the isolated Fe‐N x active sites and their structural similarity with natural metalloproteases.

Ding, Shichao↗

Metal–Organic Framework-Based Microfluidic Impedance Sensor Platform for Ultrasensitive Detection of Perfluorooctanesulfonate

The growing global concerns to public health from human exposure to perfluorooctanesulfonate (PFOS) requires rapid, sensitive, in-situ detection where current, state-of-the-art techniques are yet to adequately meet sensitivity and selectivity standards of the real-world. This work presents, for the first time, a synergistic approach for the targeted affinity-based capture of PFOS using a porous sorbent probe that enhances detection sensitivity by embedding it on a microfluidic conductive platform. This novel sorbent-containing platform functions as an electrochemical sensor to directly measure PFOS concentration through a proportional change in electrical response (increase in impedance). The extremely high surface area and pore volume of mesoporous metal-organic framework (MOF) Cr-MIL-101 is used as the probe for targeted PFOS capture based on the affinity of the chromium center towards both the fluorine tail groups as well as the sulfonate functionalities as demonstrated by spectroscopic (NMR and XPS) and microscopic (TEM) studies. Answering the need for an ultrasensitive PFOS detection technique, we are embedding these MOF capture probes inside a microfluidic channel, sandwiched between interdigitated microelectrodes (IDµE). The nanoporous geometry increases the signal to noise ratio of interdigitated microelectrodes tremendously increasing sensitivity; this in combination with the ability of the capture probes to interact with the PFOS at the molecular level and effectively transduce that response electrochemically has allowed us achieve a PFOS detection limit of 0.5 ng/L, which is unprecedented for in-situ analytical PFOS sensors and even comparable to quantification limits achieved using state-of-the-art ex situ techniques.

36 MATERIALS SCIENCE↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Quantification of gas concentrations in NO/NO 2 /C 3 H 8 /NH 3 mixtures using machine learning

We employ machine learning to decode the composition of unknown gas mixtures from the output of an array of four electrochemical sensors. The sensors use metal oxide electrodes paired with a ceramic electrolyte, yttria-stabilized zirconia (YSZ), to produce voltage responses to the presence of gases in complex mixtures. The voltages from the sensor array serve as inputs to a machine learning pipeline which first carries out multi-class classification of mixtures into types based on which gases are present at non-zero concentrations, and subsequently predicts gas concentrations given the mixture type. Thus, our model is able to take a single reading from the sensor array in response to gas mixtures involving NO, NO 2 , C 3 H 8 , and NH 3 , and output a highly accurate prediction of which gases are present in the mixture, along with the concentrations of each constituent gas. Of note, our computational framework can be easily expanded to include additional gases and additional mixture types, allowing it to be used in numerous automotive, industrial and environmental monitoring settings.

47 OTHER INSTRUMENTATION↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measured Indoor Nitrogen Oxides in Homes with a Child with Asthma and Gas or Induction Electric Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study is a randomized control trial investigating the effects of replacing gas with induction electric ranges in the homes of children with asthma in California's San Joaquin Valley. Indoor air quality parameters and respiratory health indicators were measured over 2-week intensive at Baseline and after consecutive 3-month study phases, with half getting electric cooking at the start of Phase 1 and others in Phase 2. Indoor air measurements included time-integrated NO 2 and NO X by passive sampler and time-resolved NO 2 by electrochemical sensors. In the first 40 homes, data were collected during 61 intensives for gas cooking and 55 for induction. Cooking was identified using temperature sensors above the cooktop. Pollutant events were identified from sharp rises in concentrations Time integrated NOX species were lower with electric cooking, with mean differences of 14.2 ppb for NO 2 (95% CI: 9.6, 18.7; p < 0.001), 55.6 ppb for NO X (95% CI: 30.4, 80.9; p < 0.001), and 41.5 ppb for derived NO (95% CI: 19.7, 63.2; p < 0.001). A paired, within home analysis showed larger reductions in Group 2 (gas to induction) than Group 1 that remained electric across Phase 1 and Phase 2 for NO 2 (mean difference in As of 10.5 ppb; 95% CI: 5.6, 15.4; p < 0.001), NO X (32.3 ppb; 95% CI: 10.0, 54.5; p=0.007), and derived NO (21.8 ppb; 95% CI: 3.6, 40.0; p=0.022). Compared to electric cooking, gas had much higher rates of associated NO 2 events, and larger above-baseline NO 2 peaks. These preliminary results are consistent with prior findings that shifting to induction cooking can substantially lower indoor NO 2 compared with gas cooking.

Fang, Yi↗

Combinatorial sputter deposition of ultrathick Au-Bi alloy films

We report gold-bismuth alloys are of interest as catalysts and catalytic sensing systems, electrochemical sensors, superconductors, and hohlraums for magnetically assisted inertial confinement fusion implosions. Radiation-hydrodynamics simulations with the Lasnex code of laser-driven hohlraums predict higher x-ray drive from Au-Bi alloys compared with cases of Au-Ta or pure Au and Bi hohlraums. Here, we use direct current magnetron sputtering in Ar gas, with co-sputtering from two elemental targets, to deposit Au-Bi alloys with Bi content of 9–77 at.% and thicknesses up to ~20 µm. Films are characterized by a combination of x-ray diffraction, Rutherford backscattering, scanning electron microscopy, substrate-curvature-based residual stress, and electronic transport measurements. Experiments are complemented by Monte Carlo simulations of ballistic sputtering and gas phase transport of depositing species and Ar gas atoms. Results show that all films are polycrystalline, with three distinct compositional regimes dominated by Au, Au 2 Bi, and Bi crystallographic phases. A metallic behavior of the temperature dependence of electrical resistivity is observed for all the films. Films with Bi content above ~30 at.% exhibit porosity, which is tolerable to hohlraum x-ray drive based on Lasnex simulations.

36 MATERIALS SCIENCE↗

Visualizing energy transfer between redox-active colloids

Redox-active colloids (RACs) represent a novel class of energy carriers that exchange electrical energy upon contact. Understanding contact-mediated electron transfer dynamics in RACs offers insights into physical contact events in colloidal suspensions and enables quantification of electrical energy transport in nonconjugated polymers. Redox-based electron transport was directly observed in monolayers of micron-sized RACs containing ethyl-viologen side groups via fluorescence microscopy through an unexpected nonlinear electrofluorochromism that is quantitatively coupled to the redox state of the colloid. Via imaging studies, using this electrofluorochromism, the apparent charge transfer diffusion coefficient D CT of the RAC was easily determined. The visualization of energy transport within suspensions of redox-active colloids was also demonstrated. Our work elucidates fundamental mechanisms of energy transport in colloidal systems, informs the development of next-generation redox flow batteries, and may inspire new designs of smart active soft matter including conductive polymers for applications ranging from electrochemical sensors and organic electronics to colloidal robotics.

Qu, Alan Subing [Univ. of Illinois at Urbana-Champ↗

Progression to Compatibility Evaluations in Flowing Molten Salts

Molten salt compatibility with structural alloys has been identified as a key issue for the development of Generation 3 concentrating solar power (CSP) systems with thermal storage. To accelerate this evaluation to pumped systems, the goal of this project was to conduct thermal convection loop (TCL) experiments with a peak temperature of ≥700°C and a typical temperature gradient of ~100°C. The experiments indicated that conventional ~16wt.%Cr Ni-based alloys are compatible up to 700°C with purified (i.e. low O) or dried (low H₂O) industrial-sourced Mg-K-Na chloride salt with <10 μm/yr loss. This two-year project was conducted based on the experimental and mechanistic understanding developed more than 60 years ago at Oak Ridge National Laboratory (ORNL). The first TCL experiment met the <15 μm/yr corrosion metric for this project with specimens of Ni-based alloy 600 exposed at 580°-700°C for 1000 h and post-exposure room temperature tensile tests showed minimal degradation. The second TCL experiment successfully deployed an electrochemical sensor from Argonne National Laboratory and had a peak temperature of 750°C but only ran for ~110 h due to a furnace failure. Both experiments used highly purified industrial-sourced salt with an O content of ~3 μg O/g salt and a Mg addition of 0.04 wt.%. In the second year, the Chloride Collective developed a more economical drying procedure such that the O content was much higher (>20,000 μg O/g salt). A third TCL experiment was conducted with a sensor and a peak temperature of 700°C using dried salt from the same industrial source and increased NaCl content (~20 wt.%). In addition to a 0.05% Mg addition to the salt, a Mg coupon was added in the coldest part of the loop which dissolved during the experiment. Again, small mass changes were noted for specimens of alloys 600 and C276 but the values were slightly higher than those measured in purified salt with Mg. A thin non-continuous and non-adherent oxide layer was deposited on most specimens containing Mg, Si and Al but Cr depletion also was observed. Both years included facilities qualification crucible experiments and then capsule experiments to confirm a baseline isothermal reaction rate. The first year capsule experiment led to the conclusion that the two-stage ORNL purification process using NH₄Cl and CCl₄ left the salt with a high Cl potential and a Mg addition (~0.05wt.%) was needed to lower the potential. The second year capsule experiments at 600° and 700°C found little difference in depth of attack for 0-0.25%Mg additions. In general, the complex reactions where salt can be trapped in the porous surface layer of metal indicated that mass change is an unreliable metric and average depth of Cr depletion is a better metric for assessing the extent of attack. These results have created a new baseline that is contrary to the recent published literature for chloride salts where mass losses have been reported that can be extrapolated to very significant annual metal loss rates. Chloride salt corrosion can be controlled and the results also indicate that salt purification to low O levels may not be necessary. However, additional TCL experiments are needed at different times and temperatures to generate important engineering information such as temperature dependent corrosion rates and reaction rate laws for extrapolation to long-term behavior and isolate the effect of salt additives and impurities.

36 MATERIALS SCIENCE↗

Applying Anodic Stripping Voltammetry to Complex Wastewater Streams for Rapid Metal Detection (Final Report)

The overall objective of this project is the development of a lab-on-a-chip (LOC) electrochemical sensor capable of accurately measuring heavy metal (lead (Pb), cadmium (Cd), and arsenic (As)) concentrations in complex aqueous streams such as wastewater. The specific goals include: i) identify how heavy metal speciate and transform during the different stages of the wastewater treatment train, and explore pre-treatment methods that will de-complex heavy metals, making them available to ASV, ii) develop appropriate electrodes for ASV using organic/inorganic nanomaterials, and iii) integrate pre-treatment steps and specialized electrodes into an LOC sensor device capable of autonomously determining heavy metal concentrations in complex wastewater streams.

99 GENERAL AND MISCELLANEOUS↗

Molecular Scale Tuning of Covalent Organic Frameworks for Enhanced Properties

Covalent organic frameworks (COFs) are a type of porous, extended structure material which has demonstrated utility in numerous applications, including sensing and separations. Judicious choice of the linker and node not only fine tune the size of the framework, but also the functionality. We seek to tailor COF materials for applications in gas capture and electrochemical sensing. Herein, we demonstrate the material properties of COFs can be fine-tuned via post-synthetic metal cation doping of the parent structures. We have synthesized several COF structures with varying linkers which allow for the incorporation of metal cations. Structures incorporating Zn 2+ , Mn 2+ , and Cu 2+ have demonstrated utility in improving the CO 2 uptake properties of the COFs, while Ag + doped structures show potential as electrochemical sensors for chloride anions.

36 MATERIALS SCIENCE↗

Proton exchange membrane material and methods of making the same

Hydrocarbon proton exchange membranes are disclosed that are composed of a material including a hydrophobic main chain, and acidic side chains. The main chain includes a polyaryl structure that is substantially free of ether linkages and also includes a fluoromethyl substituted carbon. The acidic side chains include a hydrocarbon tether terminated by a strongly acidic group, such as a fluoroalkyl sulfonate group. Chemical stability of the material is increased by removing the ether linkages from the main chain. The hydrophobic main chain and substantially hydrophilic side chains create a phase-separated morphology that affords enhanced transport of protons and water across the membrane even at low relative humidity levels. These materials are advantageous as membranes for use in fuel cells, redox flow batteries, water hydrolysis systems, sensors, electrochemical hydrogen compressors, actuators, water purifiers, gas separators, etc.

Bae, Chulsung↗

Zinc Oxide–Graphene Nanocomposite-Based Sensor for the Electrochemical Determination of Cetirizine

A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics

The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.

59 BASIC BIOLOGICAL SCIENCES↗