Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cathode and insulator materials for a 30 kW arcjet thruster

This paper describes past experience with 30 kW arcjet engines, emphasizing the operational parameters pertinent to the selection of new/alternate erosion-resistant materials to enhance lifetime. Mechanisms of mass loss from the electrodes and insulators are suggested, and ways of identifying potential processes for controlling cathode erosion and insulator degradation are proposed. The limitations of present materials used in critical arcjet thruster components are described. An outline is given of the criteria and the figure of merit on which the selection of candidate materials can be based. Potentially useful new/alternate materials are listed based on available thermophysical and other material properties.

Sokolowski, Witold↗

Fabrication and testing of silver-hydrogen cells

Silver electrodes containing various additives were fabricated and tested in single electrode cells in order to improve the electrochemical utilization of sintered silver cathodes in Ag-H2 aerospace batteries. A standard stack arrangement was used which featured a NASA-developed organic-inorganic separator. All cells were cycled in a regime designed to remove 75% of the cells nominal capacity based on 3.3 gms/AHr Ag utilization. In cases where performance degradation was observed, the main feature mode appeared to be corrosion of either the expanded silver current collector or the connection between the silver electrode and the electrode tab. Promising silver electrodes from single electrode studies were used in the construction of 35 AHr Ag-H2 cells. Two such cells were constructed and installed in heavy walled pressure vessels for testing. Based on the data obtained from all cells tested during the program, four lightweight 35 AHr cells were fabricated. During acceptance testing these cells yielded an average gravimetric energy density of 30 WHr/1b.

Debicarri, D. J.↗

Antireduction Insulator For Solid-Electrolyte Cell

Depletion of oxygen from electrolyte prevented. Proposed to add layer of electrical insulation between solid electrolyte and portion of porous negative electrode under negative metal contact in solid-electrolyte cell. Helps maintain efficiency of cell by preventing "shadow" effect degrading portion of electrolyte under negative contact and sometimes near seals.

Shlichta, Paul J.↗

Characterization of Commercial Li-ion Cells in Pouch Format

The li-ion pouch design cells exhibit similar behavior under off-nominal conditions as those in metal cans that do not have the internal safety devices. Safety should be well characterized before batteries are designed. Some of the li-ion pouch cell designs studied in this program reacted most violently to overcharge conditions at the medium rates but were tolerant to overcharge at very low rates. Some pouch cell designs have higher tolerance to vacuum exposures than some others. A comparison of the pouch material itself does not show a correlation between this tolerance and the number of layers or composition of the pouch indicating that this is a property of the electrode stack design inside the pouch. Reduced pressure (8 to 10 psi) test environments show that the extent of capacity degradation under reduced pressure environments is much less than that observed under vacuum conditions. Lithium-ion Pouch format cells are not necessarily true polymer cells.

Jeevarajan, Judith↗

Experimental study of the electrolysis of silicate melts

To produce oxygen from lunar resources, it may be feasible to melt and electrolyze local silicate ores. This possibility was explored experimentally with synthesized melts of appropriate compositions. Platinum electrodes were employed at a melt temperature of 1425 C. When silicon components of the melt were reduced, the platinum cathode degraded rapidly, which prompted the substitution of a graphite cathode substrate. Discrete particles containing iron or titanium were found in the solidified electrolyte after three hours of electrolysis. Electrolyte conductivities did not decrease substantially, but the escape of gas bubbles, in some cases, appeared to be hindered by high viscosity of the melt.

Keller, R.↗

Stabilizing platinum in phosphoric acid fuel cells

Platinum sintering on phosphoric acid fuel cell cathodes is discussed. The cathode of the phosphoric acid fuel cell uses a high surface area platinum catalyst dispersed on a conductive carbon support to minimize both cathode polarization and fabrication costs. During operation, however, the active surface area of these electrodes decreases, which in turn leads to decreased cell performance. This loss of active surface area is a major factor in the degradation of fuel cell performance over time.

Remick, R. J.↗

NiH2 Cycle Life Study

Cycle life studies have been performed at Eagle Picher Technologies (EPT), on HST Mantech design cells with various pedigrees of slurry and dry sinter processed electrodes, to evaluate peak load voltage performance during generic load profile testing. These tests provide information for determining voltage and capacity fade (degradation) mechanisms, and their impact on nickel hydrogen cell cycle life. Comparison of peak load voltage fade, as a function of State of Charge and cycle life, with capacity data from HST indicates that the cycle life limiting mechanism is due to impedance growth, and formation of a second discharge plateau. With a second plateau on discharge, capacity from the cell is still available, but at an unacceptable low voltage of 0.8 V per cell (17.6 V battery). Data shows that cell impedance increases with cycle number and depth of discharge, as expected.

Hollandsworth, Roger P.↗

Research on rechargeable oxygen electrodes.

A research program is described which consisted of studying the effects of electrode cycling in very pure KOH solutions, with and without controlled additions of impurities, on oxide formation, oxygen evolution kinetics, oxygen reduction kinetics (including hydrogen peroxide formation), and changes in electrode structure. Bright platinum, platinized platinum, and Teflon-bonded platinum black electrodes were studied. Three main problem areas are identified: the buildup of a refractory anodic layer on prolonged cycling, which leads to a degradation of performance; the dissolution and subsequent deposition of dendritic platinum in the separator, leading to short-circuit ing and loss of electrocatalyst; and the disruptive effect of bubbling during gas evolution on charge. Each of these problem areas is analyzed, and remedial solutions are proposed.

Giner, J.↗

High voltage pulse ignition of mercury discharge hollow cathodes

A high voltage pulse generated by a capacitor discharge into a step-up transformer has been demonstrated capable of consistently igniting hollow cathode mercury discharges at propellant flows and heater power levels much below those required by conventional cathode starting. Results are presented for 3.2-mm diameter enclosed and open keeper cathodes. Starting characteristics are shown to depend on keeper voltage, mercury flow rate, heater power, keeper orifice size, emissive materials, and electrode to which the pulse is applied. This starting technique has been used to start a cathode over 10,000 times without any degradation of starting capability.

Wintucky, E. G.↗

High voltage pulse ignition of mercury discharge hollow cathodes

A high voltage pulse generated by a capacitor discharge into a step-up transformer has been demonstrated capable of consistently igniting hollow cathode mercury discharges at propellant flows and heater power levels much below those required by conventional cathode starting. Results are presented for 3.2-mm diameter enclosed and open keeper cathodes. Starting characteristics are shown to depend on keeper voltage, mercury flow rate, heater power, keeper orifice size, emissive materials, and electrode to which the pulse is applied. This starting technique has been used to start a cathode over 10,000 times without any degradation of starting capability. The starting reliability, propellant and power savings offered by the high voltage pulse start should favorably impact performance of electron bombardment thrusters in missions requiring many on-off duty cycles.

Wintucky, E. G.↗

Developments in Fullerene Ion Propulsion Research

Several reports of successful operation of DC discharges using fullerene vapor have been made. However, degradation of the propellant molecules in the vapor source and in contact with the filament cathode was observed in each case. Because disintegration of the fullerene cage could result in poor performance or thruster failure, we have developed an RF ion thruster for use with C 60 propellant to avoid the presence of electrodes inside the discharge chamber. Also, we conducted a series of experiments to ascertain the stability of fullerenes at high temperatures. We find that when C 60 and C 70 are maintained at temperatures above 1073 K, or are exposed to hot metal surfaces, significant degradation occurs. We find an activation energy of 261.5 kJ/mol for this process. At temperatures below 873 K, no breakdown of fullerenes can be detected, even after heating for 6 hours. The effect of these findings on C 60 ion thruster design is discussed.

fullerenes↗

Characterization of physiochemical properties of polymeric and electrochemical materials for aerospace flight

Nickel-cadmium rechargeable batteries are a vital and reliable energy storage source for aerospace applications. As the demand for longer life and more reliable space batteries increases, the understanding and solving of cell aging factors and mechanisms become essential. Over the years, many cell designs and manufacturing process changes have been developed and implemented. Cells fabricated with various design features were life cycled in a simulated low-Earth orbit regime. Following the test program, a comprehensive electrochemical analysis of cell components was undertaken to study cell degradation mechanisms. Discharge voltage degradation or voltage plateau has been observed during orbit cycling, but, its cause and explanation have been the subject of much discussion. A Hg/HgO reference electrode was used to monitor the reference versus each electrode potential during the discharge of a cycled cell. The results indicate that the negative electrode was responsible for the voltage plateau. Cell analysis revealed large crystals of cadmium hydroxide on the surface of the negative electrode and throughout the separator.

Rock, M.↗

Hughes advanced nickel-cadmium batteries: An update

After delivering a significant data base on boilerplate and prototype advanced nickel cadmium (Ni/Cd) battery cells, Hughes decided to start using the Advanced Ni/Cd batteries on several of their flight programs. The advanced cell can been operated at 80 percent depth of discharge (DOD) for more than 10 years, and possibly 15 years, in geosynchronous earth orbit (GEO) applications. This cell offers an important weight saving over the standard Ni/Cd cell that is usually only operated at 50 to 60 percent DOD in GEO applications. The negative and positive electrodes are manufactured using electrochemical deposition methods which reduce the sinter corrosion problems encountered by the chemical deposition process used in the standard cells. The degradable nylon separators used in standard cells was replaced by polymer impregnated Zirconia separators.

Bogner, R. Sam↗

Leakage Currents in Low-Voltage PME and BME Ceramic Capacitors

Introduction of BME capacitors to high-reliability electronics as a replacement for PME capacitors requires better understanding of changes in performance and reliability of MLCCs to set justified screening and qualification requirements. In this work, absorption and leakage currents in various lots of commercial and military grade X7R MLCCs rated to 100V and less have been measured to reveal difference in behavior of PME and BME capacitors in a wide range of voltages and temperatures. Degradation of leakage currents and failures in virgin capacitors and capacitors with introduced cracks has been studied at different voltages and temperatures during step stress highly accelerated life testing. Mechanisms of charge absorption, conduction and degradation have been discussed and a failure model in capacitors with defects suggested.

base metal electrode capacitor (BME)↗

High speed, nondestructive readout from thin-film ferroelectric memory

High-speed polarization-direction-dependent photoresponse from ferroelectric lead zirconate titanate (PbZr(0.53)Ti(0.47)O3) thin films sandwiched between conducting electrodes to form a memory capacitor is reported. Laser pulses with a full width at half maximum of around 10 ns at 532-nm wavelength are utilized to readout the photoresponse signal from individual polarized elements. Such readout is repeated over a million times, with no detectable degradation in the photoresponse or the remanent polarization suggesting its potential as a nondestructive readout (NDRO) of nonvolatile polarization state in thin-film ferroelectric memories. In principle both electronic as well as thermal mechanisms could be triggered by such photon exposure of ferroelectric thin films. A comparison of the photoresponse from capacitors with semitransparent and opaque top electrodes suggests that the observed NDRO signal is primarily due to thermally triggered mechanisms.

Thakoor, Sarita↗

Evaluation of Carbon Anodes for Rechargeable Lithium Cells

Both liquid phase intercalation technique and electrochemical intercalation technique were examined for the Li-carbon material preparation. The electrochemical techniques include a intermittent discharge method and a two step method. These two electrochemical techniques can ensure to achieve the maximum reversible Li capacity for common commercially available carbon materials. The carbon materials evaluated by the intercalacation method includes: pitch coke, petroleum cole, PAN fiber and graphite materials. Their reversible Li capacity were determined and compared. In this paper, we also demonstrate the importance of EPDM binder composition in the carbon electrode. Our results indicated that it can impact the Li intercalation and de-intercalation capacity in carbon materials. Finally, two possibilities that may help explain the capacity degradation during practical cell cycling were proposed.

carbon anodes rechargeable lithium cells material ↗

A laser microsurgical method of cell wall removal allows detection of large-conductance ion channels in the guard cell plasma membrane

Application of patch clamp techniques to higher-plant cells has been subject to the limitation that the requisite contact of the patch electrode with the cell membrane necessitates prior enzymatic removal of the plant cell wall. Because the wall is an integral component of plant cells, and because cell-wall-degrading enzymes can disrupt membrane properties, such enzymatic treatments may alter ion channel behavior. We compared ion channel activity in enzymatically isolated protoplasts of Vicia faba guard cells with that found in membranes exposed by a laser microsurgical technique in which only a tiny portion of the cell wall is removed while the rest of the cell remains intact within its tissue environment. "Laser-assisted" patch clamping reveals a new category of high-conductance (130 to 361 pS) ion channels not previously reported in patch clamp studies on plant plasma membranes. These data indicate that ion channels are present in plant membranes that are not detected by conventional patch clamp techniques involving the production of individual plant protoplasts isolated from their tissue environment by enzymatic digestion of the cell wall. Given the large conductances of the channels revealed by laser-assisted patch clamping, we hypothesize that these channels play a significant role in the regulation of ion content and electrical signalling in guard cells.

Non-NASA Center↗

Evaluation of Galvanic Vestibular Stimulation System

Microgravity exposure results in an adaptive central reinterpretation of information from multiple sensory sources to produce a sensorimotor state appropriate for motor actions in this unique environment, but this new adaptive state is no longer appropriate for the 1-g gravitational environment on Earth. During these gravitational transitions, astronauts experience deficits in both perceptual and motor functions including impaired postural control, disruption in spatial orientation, impaired control of locomotion that include alterations in muscle activation variability, modified lower limb kinematics, alterations in head-trunk coordination as well as reduced dynamic visual acuity. Post-flight changes in postural and locomotor control might have adverse consequences if a rapid egress was required following a long-duration mission, where support personnel may not be available to aid crewmembers. The act of emergency egress includes, but is not limited to standing, walking, climbing a ladder, jumping down, monitoring displays, actuating discrete controls, operating auxiliary equipment, and communicating with Mission Control and recovery teams while maintaining spatial orientation, mobility and postural stability in order to escape safely. The average time to recover impaired postural control and functional mobility to preflight levels of performance has been shown to be approximately two weeks after long-duration spaceflight. The postflight alterations are due in part to central reinterpretation of vestibular information caused by exposure to microgravity. In this study we will use a commonly used technique of transcutaneous electrical stimulation applied across the vestibular end organs (galvanic vestibular stimulation, GVS) to disrupt vestibular function as a simulation of post-flight disturbances. The goal of this project is an engineering human-in-the-loop evaluation of a device that can degrade performance of functional tasks (e.g. to maintain upright balance) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

Kofman, I. S.↗