Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrolyte effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fluid and Electrolyte Balance model (FEB)

The effects of various oral input water loads on solute and water distribution throughout the body are presented in the form of a model. The model was a three compartment model; the three compartments being plasma, interstitial fluid and cellular fluid. Sodium, potassium, chloride and urea were the only major solutes considered explicitly. The control of body water and electrolyte distribution was affected via drinking and hormone levels.

Fitzjerrell, D. G.↗

Effect of Fluid Flow on Zinc Electrodeposits from Acid Chloride Electrolytes

Zinc was deposited potentiostatically from acid chloride baths. Once bath chemistry and electrochemistry were controlled, the study was focused on convective mass transfer at horizontal electrodes and its effect on cell performance. A laser schlieren imaging technique allowed in situ observations of flow patterns and their correlation with current transients. Convection was turbulent and mass transfer as a function of Rayleigh number was well correlated by: Sh = 0.14 R to the 1/3 power. Similarly, convection initiation time was correlated by DT/d squared = 38 Ra to the -2/3 power. Time scale of fluctuations was about half the initiation time. Taking the boundary layer thickness as a characteristic length, a critical Rayleigh number for the onset of convection was deduced: Ra sub CR = 5000. Placing the anode on the top of the cathode completely changed the flow pattern but kept the I-t curves identical whereas the use of a cathode grid doubled the limiting current. A well defined plateau in the current voltage curves suggested that hydrogen evolution has been successfully inhibited. Finally, long time deposition showed that convection at horizontal electrodes increased the induction time for dentrite growth by at least a factor of 2 with respect to a vertical wire.

Abdelmassir, A. A.↗

Prolonged fasting increases the response of the renin-angiotensin-aldosterone system, but not vasopressin levels, in postweaned northern elephant seal pups

The 8- to 12-week postweaning fast exhibited by northern elephant seal pups (Mirounga angustirostris) occurs without any apparent deleterious effects on fluid and electrolyte homeostasis. However, during the fast the role of vasopressin (AVP) has been shown to be inconclusive and the involvement of the renin-angiotensin-aldosterone system (RAAS) has yet to be examined. To examine the effects of prolonged fasting on these osmoregulatory hormones, 15 postweaned pups were serially blood-sampled during the first 49 days of their fast. Fasting did not induce significant changes in ionic or osmotic concentrations, suggesting electrolyte homeostasis. Total proteins were reduced by day 21 of fasting and remained depressed, suggesting a lack of dehydration. Aldosterone and plasma renin activity exhibited a correlated, linear increase over the first 49 days of the fast, suggesting an active RAAS. Aldosterone exhibited a parabolic trend over the fast with a peak at day 35, suggesting a shift in the sensitivity of the kidney to aldosterone later in the fast. AVP was elevated at day 49 only, but concentrations were relatively low. RAAS was modified during the postweaning fast in pups and appears to play a significant role in the regulation of electrolyte and, most likely, water homeostasis during this period. Copyright 2000 Academic Press.

NASA Discipline Regulatory Physiology↗

Safer Electrolytes for Lithium-Ion Cells

A number of nonvolatile, low-flammability liquid oligomers and polymers based on aliphatic organic carbonate molecular structures have been found to be suitable to be blended with ethylene carbonate to make electrolytes for lithium-ion electrochemical cells. Heretofore, such electrolytes have often been made by blending ethylene carbonate with volatile, flammable organic carbonates. The present nonvolatile electrolytes have been found to have adequate conductivity (about 2 mS/cm) for lithium ions and to remain liquid at temperatures down to -5 C. At normal charge and discharge rates, lithiumion cells containing these nonvolatile electrolytes but otherwise of standard design have been found to operate at current and energy densities comparable to those of cells now in common use. They do not perform well at high charge and discharge rates -- an effect probably attributable to electrolyte viscosity. Cells containing the nonvolatile electrolytes have also been found to be, variously, nonflammable or at least self-extinguishing. Hence, there appears to be a basis for the development of safer high-performance lithium-ion cells.

Kejha, Joe↗

Direct Electrolysis of Molten Lunar Regolith for the Production of Oxygen and Metals on the Moon

When considering the construction of a lunar base, the high cost ($ 100,000 a kilogram) of transporting materials to the surface of the moon is a significant barrier. Therefore in-situ resource utilization will be a key component of any lunar mission. Oxygen gas is a key resource, abundant on earth and absent on the moon. If oxygen could be produced on the moon, this provides a dual benefit. Not only does it no longer need to be transported to the surface for breathing purposes; it can also be used as a fuel oxidizer to support transportation of crew and other materials more cheaply between the surface of the moon, and lower earth orbit (approximately $20,000/kg). To this end a stable, robust (lightly manned) system is required to produce oxygen from lunar resources. Herein, we investigate the feasibility of producing oxygen, which makes up almost half of the weight of the moon by direct electrolysis of the molten lunar regolith thus achieving the generation of usable oxygen gas while producing primarily iron and silicon at the cathode from the tightly bound oxides. The silicate mixture (with compositions and mechanical properties corresponding to that of lunar regolith) is melted at temperatures near 1600 C. With an inert anode and suitable cathode, direct electrolysis (no supporting electrolyte) of the molten silicate is carried out, resulting in production of molten metallic products at the cathode and oxygen gas at the anode. The effect of anode material, sweep rate, and electrolyte composition on the electrochemical behavior was investigated and implications for scale-up are considered. The activity and stability of the candidate anode materials as well as the effect of the electrolyte composition were determined. Additionally, ex-situ capture and analysis of the anode gas to calculate the current efficiency under different voltages, currents and melt chemistries was carried out.

Sirk, Aislinn H. C.↗

Basic investigation into the electrical performance of solid electrolyte membranes

The electrical performance of solid electrolyte membranes was investigated analytically and the results were compared with experimental data. It is concluded that in devices that are used for pumping oxygen the major power losses have to be attributed to the thin film electrodes. Relations were developed by which the effectiveness of tubular solid electrolyte membranes can be determined and the optimum length evaluated. The observed failure of solid electrolyte tube membranes in very localized areas is explained by the highly non-uniform current distribution in the membranes. The analysis points to a possible contact resistance between the electrodes and the solid electrolyte material. This possible contact resistance remains to be investigated experimentally. It is concluded that film electrodes are not appropriate for devices which operate with current flow, i.e., pumps though they can be employed without reservation in devices that measure oxygen pressures if a limited increase in the response time can be tolerated.

Richter, R.↗

Solid-state battery designed for electric aviation

The demand for higher energy density batteries increases as the demand for portable electronic devices and electric automotive increases, as well as a variety of other applications requiring substantially higher power and energy than attainable with current lithium-ion capabilities which includes the areas of high performance vehicles, military applications, and electric aviation. However, the improvement of energy density is insufficient alone for enabling electric aviation when considering the high flammability and risk of thermal runaway inherent in current state-of-the-art liquid electrolytes. The development of high energy, high power, and safe batteries are required to enable hybrid and fully electric aircraft. Next generation chemistries such as lithium-sulfur provide high theoretical specific energy density suitable for electric aviation without as strict of volumetric requirements observed in the automotive industry. However, due to the phase transition during discharge where sulfur generates a series of soluble intermediate polysulfides, which are lost to the liquid electrolyte, cause detrimental side effects, and severely limit cycle life battery performance is severely reduced. Additionally, the low electrical conductivity of sulfur requires a large amount of inactive carbon dramatically increasing parasitic mass. The dissolution issue make sulfur a desirable candidate to pair with a solid-state electrolyte in order to avoid polysulfide dissolution and shuttling. In addition, inorganic solid-electrolytes have low flammability providing the improved safety required. Combining this chemistry with a solid-state electrolyte provides a path for achieving the energy and safety required for electric aviation. The development of scalable thin solid-state electrolytes paired with lithium-sulfur chemistry will be discussed and how their development will aid in enabling a unique application.

Donald A. Dornbusch↗

Effects of 17 days of head-down bed rest on hydro-electrolytic regulation in men

Prolonged periods of head-down bed rest (HDBR) are commonly used to mimic the effects of microgravity. HDBR has been shown to produce, as in space, a cephalad redistribution of circulating blood volume with an increase in central blood volume which induces the early adaptations in blood volume regulating hormones. Changes in atrial natriuretic peptide (ANP), arginine vasopressin (AVP), renin activity and aldosterone have been observed. Many reports describe these endocrine adaptations but few investigations of rhythms are in the literature. We proposed to evaluate the circadian rhythms of the hormones and electrolytes involved in the hydro-electrolytic regulation during a HDBR study which was designed to simulate a 17-day spaceflight (Life and Microgravity Spacelab experiment, LMS, NASA).

NASA Center ARC↗

Human cardiovascular response to sympathomimetic agents during head-down bed rest: the effect of dietary sodium

Changes in sympathoadrenal function and cardiovascular deconditioning have long been recognized as a feature of the physiological adaptation to microgravity. The deconditioning process, coupled with altered hydration status, is thought to significantly contribute to orthostatic intolerance upon return to Earth gravity. The cardiovascular response to stimulation by sympathomimetic agents before, during, and after exposure to simulated microgravity was determined in healthy volunteers equilibrated on normal or high sodium diets in order to further the understanding of the deconditioning process.

NASA Discipline Number 18-10↗

Replication of the Apparent Excess Heat Effect in a Light Water-Potassium Carbonate-Nickel Electrolytic Cell

Replication of experiments claiming to demonstrate excess heat production in light water-Ni-K2CO3 electrolytic cells was found to produce an apparent excess heat of 11 W maximum, for 60 W electrical power into the cell. Power gains range from 1.06 to 1.68. The cell was operated at four different dc current levels plus one pulsed current run at 1 Hz, 10% duty cycle. The 28 liter cell used in these verification tests was on loan from a private corporation whose own tests with similar cells are documented to produce 50 W steady excess heat for a continuous period exceeding hundreds of days. The apparent excess heat can not be readily explained either in terms of nonlinearity of the cell's thermal conductance at a low temperature differential or by thermoelectric heat pumping. However, the present data do admit efficient recombination of dissolved hydrogen-oxygen as an ordinary explanation. Calorimetry methods and heat balance calculations for the verification tests are described. Considering the large magnitude of benefit if this effect is found to be a genuine new energy source, a more thorough investigation of evolved heat in the nickel-hydrogen system in both electrolytic and gaseous loading cells remains warranted.

Niedra, Janis M.↗

Duration versus response to space-flight exposure

The duration of human expeditions into space has been as short as a few hours and as long as a year, and although we still need much more information, we can identify some trends indicating effects of flight duration on the physiologic response to space flight. Evidence suggests that after a period of dynamic change that varies for each physiologic system, some physiologic variable stabilize at levels that may differ from those at 1 G. Other variables appear to undergo change from time to time even after months in space, and others have not been observed to reach a plateau. Effects on the neurovestibular system begin very early and certain ones diminish rapidly. Effects of weightlessness on fluid and electrolyte physiology appear to reach a peak after that of neurophysiologic effects. It is possible that the initial responses of these two systems follow a more similar time course than is now apparent. Responses of the cardiovascular system reach a peak that approaches clinical significance after about 3 weeks. The mass of red blood cells is maximally altered after about a month. Bone mineral and lean body mass are lost gradually for at least 6 months, perhaps longer.

Leach, Carolyn S.↗

Influence of ultrasounds on electrolytic polishing

On the basis of study of the electrolytic polishing of metal pieces, the following conclusions can be drawn: (1) Utilization of ultrasonically irradiated electrolytes in the electrolytic polishing of copper and steel pieces leads to enhanced polishing quality. (2) Polishing time for the reference pieces was twice as long as for the test pieces. (3) The chemical attack exerted on the surface of the test pieces in order to get the structure of the respective metal lasted less than half as long and yielded superior qualitative results in the copper as well as in the OT 60-2 steel test pieces polished with ultrasonically irradiated electrolytes. (4) The utilization of higher polishing current densities can be explained by the fact that the cavitational effect that arises in the electrolyte owing to ultrasounds contributes to an increase in the solution's electrical conductivity and elimination of gases from the electrolyte.

Gavrila, I.↗

Acutely elevated vasopressin increases circulating concentrations of cortisol and aldosterone in fasting northern elephant seal (Mirounga angustirostris) pups

The physiological actions of vasopressin (VP) in marine mammals are not well defined. To help elucidate its hormonal and renal effects in this group of mammals, northern elephant seal (Mirounga angustirostris) pups (N=7; 99+/-4 kg) were first infused with 0.9% saline (control; 220 ml), followed 24 h later with VP (as a 20 ng kg(-1) bolus, then 2 ng kg(-1) min(-1) for approximately 35 min in 225+/-16 ml saline). During both control and VP periods, blood samples were collected prior to infusion, and 15, 30, 60, 120 min and 24 h after infusion to examine the hormonal responses of the pups to VP. Renal responses were quantified from 24 h urine samples obtained prior to infusion (control) and 24 h post-infusion. Compared to the control period, infusion of VP increased plasma concentrations of cortisol over a 120 min period and aldosterone over 30 min, while plasma renin activity (PRA) was decreased for a 120 min period. The plasma urea:creatinine ratio was elevated following infusion of VP. Urine output and osmotic clearance were increased by 69+/-18% (mean +/- S.E.M.) and 36+/-10%, respectively, but free water clearance and glomerular filtration rate were not significantly altered 24 h post-infusion of VP. Solute (osmolality, Na(+), K(+) and Cl(-)) excretion and fractional excretion of electrolytes were also increased when compared to control values. The increase in cortisol concentration suggests that VP may possess corticotropin releasing hormone-like activity in elephant seals. If osmotic diuresis and natriuresis are typical consequences of elevated [VP] in fasting pups, then not increasing VP normally during the fast may serve as a protective mechanism to avoid the potential loss of Na(+) induced by elevated [VP]. Therefore, under natural fasting conditions, pups may be highly sensitive to small changes in [VP], resulting in the maintenance of water and electrolyte balance.

Non-NASA Center↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

Catalysts for electrochemical generation of oxygen

An investigation of more effective catalysts for the electrolytic evolution of oxygen was made to understand the mechanism and kinetics for the electrocatalysis in relation to the surface electronic and lattice properties of the catalyst. An understanding was obtained for the structural features of the electrocatalysts. The kinetics and mechanism of anodic generation of O2 under well defined conditions in relation to the properties of electrode surface were evaluated.

Ogrady, W. E.↗

Catalysts for electrochemical generation of oxygen

Single crystal surfaces of platinum and gold and transition metal oxides of the spinel type were studied to find more effective catalysts for the electrolytic evolution of oxygen and to understand the mechanism and kinetics for the electrocatalysis in relation to the surface electronic and lattice properties of the catalyst. The single crystal studies involve the use of low energy electron diffraction (LEED) and Auger electron spectroscopy as complementary tools to the electrochemical measurements. Modifications to the transfer system and to the thin-layer electrochemical cell used to facilitate the transfer between the ultrahigh vacuum environment of the electron surface physics equipment and the electrochemical environment with a minimal possibility of changes in the surface structure, are described. The electrosorption underpotential deposition of Pb onto the Au(111), (100) and (110) single crystal surfaces with the thin-layer cell-LEED-Auger system is discussed as well as the synthesis of spinels for oxygen evolution studies.

Hagans, P.↗

Alkyl Pyrocarbonate Electrolyte Additives for Performance Enhancement of Li Ion Cells

Lithium ion rechargeable batteries are being developed for various aerospace applications under a NASA-DoD Interagency program. These applications require further improvements in several areas, specifically in the cycle life for LEO and GEO satellites and in the low temperature performance for the Mars Lander and Rover missions. Accordingly, we have been pursuing research studies to achieve improvement in the low temperature performance, long cycle life and active life of Li ion cells. The studies are mainly focused on electrolytes, to identify newer formulations of new electrolyte additives to enhance Li permeability (at low temperatures) and stability towards the electrode. The latter approach is particularly aimed at the formation suitable SEI (solid electrolyte interphase) on carbon electrodes. In this paper, we report the beneficial effect of using alkyl pyrocarbonates as electrolyte additives to improve the low temperature performance of Li ion cells.

Smart, M. C.↗