Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

An Acid-Free, Temperature-Based Cation Contamination Removal Strategy for PEM Water Electrolysis

It is widely understood that the durability and reliability of polymer electrolyte membrane (PEM) water electrolyzers are heavily dependent on feedwater purity, with cation contaminants that originate from incomplete water purification and balance of plant materials significantly harming electrolyzer performance. However, contamination remains a challenge and a common cause of failure at the stack level, indicating the need for strategies to recover the performance of contaminated cells. In this study, we investigate the effects of temperature on the uptake, electrochemical impacts, and removal of contaminant calcium and iron cations. Lower operating temperatures increase the sensitivity of the cell performance to contaminant cations, while also decreasing cation uptake and promoting contaminant removal. Computational charge transfer modelling shows that lower temperature increases the concentration of contaminant at the cathode and facilitates their removal from the cell. By testing single cells under scenarios designed to mimic stack temperature dynamics, we investigate low-temperature operation as an approach to stack-relevant contaminant recovery. Together, these results demonstrate that the low-temperature recovery approach is a promising approach for acid-free contamination recovery for PEM water electrolysis to promote stack reliability and durability.

08 HYDROGEN↗

Regenerative Fuel Cell Test Rig at Glenn Research Center

The regenerative fuel cell development effort at Glenn Research Center (GRC) involves the integration of a dedicated fuel cell and electrolyzer into an energy storage system test rig. The test rig consists of a fuel cell stack, an electrolysis stack, cooling pumps, a water transfer pump, gas recirculation pumps, phase separators, storage tanks for oxygen (O2) and hydrogen (H2), heat exchangers, isolation valves, pressure regulators, interconnecting tubing, nitrogen purge provisions, and instrumentation for control and monitoring purposes. The regenerative fuel cell (RFC) thus formed is a completely closed system which is capable of autonomous cyclic operation. The test rig provides direct current (DC) load and DC power supply to simulate power consumption and solar power input. In addition, chillers are used as the heat sink to dissipate the waste heat from the electrochemical stack operation. Various vents and nitrogen (N2) sources are included in case inert purging is necessary to safe the RFC test rig.

Chang, Bei-Jiann↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Modular SOEC System for Efficient H 2 Production at High Current Density

The overall objective of the project was to demonstrate the potential of Solid Oxide Electrolysis Cell (SOEC) systems to produce hydrogen at a cost of $\$$2.00/kg H 2 or less (excluding delivery, compression, storage, and dispensing). An additional objective of the project was to enhance Solid Oxide Electrolysis Cell (SOEC) stack endurance and impart subsystem robustness for operation on load profiles compatible with intermittent renewable energy sources. The project was designed to achieve the overall objectives through a multi-disciplinary approach that included SOEC stack and materials development, systems development and optimization, techno-economic analyses, and ultimately the demonstration of a > 4 kg H 2 /day SOEC system. The scope of work included research and development efforts to develop an advanced, high temperature, water splitting (HTWS) system with superior performance and durability relative to the current state-of-the-art. In support of the aforementioned goals, the project activities included: 1) Develop and test cell materials with improved endurance at high current densities; 2) Design and fabricate a >4 kg H 2 /day SOEC stack optimized for high efficiency operation in the range of 1 - 2 A/cm 2 ; 3) Perform stack testing under simulated system conditions; 4) Perform systems analysis including configuration and parametric studies, to maximize SOEC system efficiency and minimize H 2 production costs; 5) Develop the conceptual design of a >4 kg H 2 /day thermally self-sustaining SOEC demonstration system including stack module and balance of plant (BoP).

08 HYDROGEN↗

Introducing a novel technique for measuring hydrogen crossover in membrane-based electrochemical cells

Hydrogen crossover that is the unwanted hydrogen permeation across the membrane driven by the difference of gas concentrations causes a critical concern of safety and efficiency for electrochemical cells, such as fuel cells and electrolyzer cells. Although the hydrogen crossover measurement in fuel cells that employ platinum based catalysts is simple and widely used in laboratory settings, it is questionable to apply existing limiting current method to water electrolyzer cells and alkaline exchange membrane (AEM) systems, which is due to the typical catalyst materials used and membrane properties, respectively. In this work, we demonstrate the operation of a compact and low-cost method of measuring hydrogen crossover that works for both AEM and proton exchange membrane (PEM) systems. The method entails a tandem configuration that utilizes an upstream crossover cell with a downstream cell in hydrogen pump configuration to measure the crossover in the cell of interest. We have successfully measured the hydrogen crossover with different membranes at various differential pressures. The developed method can be applied to catalyst-free membranes (both PEM and AEM) as well as PGM free catalyst containing cells. It will be a promising technique for measuring hydrogen crossover in-situ for a real operating membraned-based electrochemical cell or stack.

08 HYDROGEN↗

H2@Scale - Validating an Electrolysis System with High Output Pressure: Cooperative Research and Development Final Report, CRADA Number CRD-18-00741

Electrolysis has been a commercially available product for a while and electrolyzers have been a proven capability to provide additional benefits (e.g. controllable load for grid services) in addition to production of hydrogen. The hydrogen output is typically compressed for storage and dispensing. Compression adds cost and decreases system reliability. Honda’s electrolyzer systems have been developed to include electrochemical compression to leverage the production system itself for at least partial compression. In this project, the team will evaluate Honda’s PEM based electrochemical compression system. The system is capable of compressing hydrogen up to 70 MPa electrochemically. Validation testing is the next step to accelerate this technology into the marketplace, as the validation will provide needed data under a variety of operation conditions and controls. These operating conditions and controls are based on over a decade of NLR research and development with low-temperature electrolysis. The validation testing will include preparing NLR’s site for third party evaluation, benchmark testing of Honda’s stack and system, and simulating operation connected to renewables or in a grid service profile. NLR’s Energy System Integration Lab will be the location for the electrolyzer validation research and integrated into the Hydrogen Infrastructure Test & Research Facility (HITRF). This will build into the existing retail style hydrogen fueling station for a fully integrated experimental setup.

08 HYDROGEN↗

Advanced Manifolds for Improved Solid Oxide Electrolyzer Performance

An investigation was conducted to see if additive manufacturing could be used to fabricate more efficient manifold designs for improved flow, reduced stresses, and decreased number of joints to be sealed for a solid oxide electrolyzer used to convert carbon dioxide to oxygen. Computational flow and mechanical modeling were conducted on a NASA Glenn Research Center patented cell and stack design with the potential to achieve a 3-4 times mass reduction. Various manifold designs were modeled, and two were downselected to be fabricated and tested. Some benefit was seen in a baffled manifold design, which directed incoming flow more effectively into the flow channels, compared to the original design, where the flow spent more time within the manifold itself. Flow measurements indicated some non-uniformity of flow across the channels at higher flow rates, which were not predicted by the model. Some possible explanations for the differences are discussed.

Linne, Diane L.↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Hydrogen Production Cost with Alkaline Electrolysis

Rigorous stakeholder-vetted techno-economic analysis was performed to assess the cost of hydrogen (H 2 ) produced using state-of-the-art Liquid Alkaline (LA) electrolysis. Projected high-volume, untaxed levelized cost of hydrogen (LCOH) range from 2020US $\$ 1.84$ to $\$ 2.88$/kg-H 2 depending on technology year, process design, and electrolyzer project scale, assuming an electricity price of $\$ 0.03$/kWh. The total installed capital cost for a LA electrolysis plant was estimated from bottom-up stack and installed cost models that account for purchased equipment, installation costs, site preparation, and general overhead costs. For this study, the LA electrolysis plant is assumed to be a stick-built, greenfield project developed by an EPC firm with electrolysis stacks purchased directly from an electrolysis stack manufacturer. The price of the electrolysis stacks is based on a bottom-up cost assessment with business markup for the electrolysis company fabricator. Methods from the Hydrogen Analysis (H 2 A) production model, a peer-reviewed national laboratory-developed discounted cash flow model, were used to calculate the LCOH production in 2020$/kg-H 2 . The baseline electricity price case ($\$ 0.03$/kWh) corresponds to average wholesale electricity prices currently possible in U.S. markets with plentiful wind. Similar low-cost electricity pricing is possible from solar Power Purchase Agreements (PPA) although these prices are typically limited by renewable energy capacity factors.

08 HYDROGEN↗

High-Temperature Alkaline Water Electrolysis

Hydrogen production for mobile and energy storage applications from water electrolysis is attractive due to its high efficiency, fast ramp rates, and potential for the clean energy economy. However, current hydrogen production from electrolysis comprises only a small fraction of the global hydrogen market due to the high cost associated with expensive stack materials (membrane, catalyst, and bipolar plates) and electricity consumption of the commercial electrolysis systems. In this project, we aimed to develop a high temperature alkaline water electrolyzer (HTAWE) that can simultaneously reduce the electrolyzer cost (by adopting cheap material) and improve energy efficiency (by enabling high-temperature operation).

08 HYDROGEN↗

A comprehensive modeling method for proton exchange membrane electrolyzer development

Hydrogen attracts significant interests as an effective energy carrier that can be derived from renewable sources. Hydrogen production using a proton-exchange membrane (PEM) electrolyzer can efficiently convert renewable power via water splitting in wide scales—from large, centralized generation to on-site production. Mathematical models with multiple scales and fidelities facilitate the continuing improvements of PEM electrolyzer development to improve performance, cost, and reliability. The model scopes and methods are presented in this paper, which also introduces a comprehensive PEM electrolysis modeling tool based on computational fluid dynamics (CFD) software, ANSYS/Fluent. The modeling tool incorporates electrochemical model of a PEM electrolysis cell to simulate the performance of coupled thermal-fluid, species transport, and electrochemical processes in a product-scale cell or stack by leveraging the powerful meshing generation and CFD solver of ANSYS/Fluent. The thermal-fluid modeling includes liquid water/gas two-phase flow and simulates a PEM electrolysis cell by using Fluent user-defined functions as add-on modules accounting for PEM-specific species transport and electrochemical processes. The modeling outcomes expediate PEM electrolyzer scaling up from basic material development and laboratory testing.

08 HYDROGEN↗

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab↗

Hydrogen Production Cost with Anion Exchange Membrane Electrolysis

Rigorous stakeholder-vetted techno-economic analysis was performed to assess the cost of hydrogen (H 2 ) produced using state-of-the-art Anion Exchange Membrane (AEM) electrolysis. Projected high-volume, untaxed and unsubsidized levelized cost of hydrogen (LCOH)1 range from 2020 $\$$1.78 to $\$$3.68/kg H 2 depending on technology year, process design, and electrolyzer project scale, assuming an electricity price of $\$$0.03/kWh and a capacity factor of 97%. The total installed capital cost for an AEM electrolysis plant was estimated from bottom-up stack and process plant cost models. The stack cost model accounts for manufacturing equipment, equipment maintenance, material, tooling, cycle time, yield, labor, utilities and general overhead. The process plant cost model accounts for purchased equipment, installation costs, site preparation, and general overhead costs. For this study, the AEM electrolysis plant is assumed to be a stick-built, greenfield project developed by an engineering, procurement, and construction (EPC) firm with electrolysis stacks purchased directly from an electrolysis stack manufacturer. The price of the electrolysis stacks is based on a bottom-up cost assessment with business markup for the electrolysis company fabricator. Methods from the Hydrogen Analysis (H2A) production model, a peer-reviewed national laboratory-developed discounted cash flow (DCF) model, were used to calculate the production LCOH in 2020 $\$$/kg H 2 . The baseline electricity price case ($\$$0.03/kWh) corresponds to average wholesale electricity prices currently possible in U.S. markets with plentiful wind. Similar low-cost electricity pricing is possible from solar Power Purchase Agreements (PPA) although these prices are typically limited by renewable energy capacity factors.

08 HYDROGEN↗