SU-G-BRB-04: Automated Output Factor Measurements Using Continuous Data Logging for Linac Commissioning

Purpose: Linac commissioning is a time consuming and labor intensive process, the streamline of which is highly desirable. In particular, manual measurement of output factors for a variety of field sizes and energy greatly hinders the commissioning efficiency. In this study, automated measurement of output factors was demonstrated as ‘one-click’ using data logging of an electrometer. Methods: Beams to be measured were created in the recording and verifying (R&V) system and configured for continuous delivery. An electrometer with an automatic data logging feature enabled continuous data collection for all fields without human intervention. The electrometer saved data into a spreadsheet every 0.5 seconds. A Matlab program was developed to analyze the excel data to monitor and check the data quality. Results: For each photon energy, output factors were measured for five configurations, including open field and four wedges. Each configuration includes 72 fields sizes, ranging from 4×4 to 20×30 cm{sup 2}. Using automation, it took 50 minutes to complete the measurement of 72 field sizes, in contrast to 80 minutes when using the manual approach. The automation avoided the necessity of redundant Linac status checks between fields as in the manual approach. In fact, the only limiting factor in such automation is Linac overheating. The data collection beams in the R&V system are reusable, and the simplified process is less error-prone. In addition, our Matlab program extracted the output factors faithfully from data logging, and the discrepancy between the automatic and manual measurement is within ±0.3%. For two separate automated measurements 30 days apart, consistency check shows a discrepancy within ±1% for 6MV photon with a 60 degree wedge. Conclusion: Automated output factor measurements can save time by 40% when compared with conventional manual approach. This work laid ground for further improvement for the automation of Linac commissioning.

43 PARTICLE ACCELERATORS↗

Poster - 17: Characterization and correction of radiation induced background in scanning water tanks

Purpose: To characterize and correct for radiation-induced background (RIB) observed in the signals from a class of scanning water tanks. Methods: A method was developed to isolate the RIB through detector measurements in the background-free linac console area. Variation of the RIB against a large number of parameters was characterized, and its impact on basic clinical data for photon and electron beams was quantified. Different methods to minimize and/or correct for the RIB were proposed and evaluated. Results: The RIB is due to the presence of the electrometer and connection box in a low background radiation field (by design). The absolute RIB current with a biased detector is up to 2 pA, independent of the detector size, which is 0.6% and 1.5% of the central axis reference signal for a standard and a mini scanning chamber, respectively. The RIB monotonically increases with field size, is three times smaller for detectors that do not require a bias (e.g., diodes), is up to 80% larger for positive (versus negative) polarity, decreases with increasing photon energy, exhibits a single curve versus dose rate at the electrometer location, and is negligible for electron beams. Data after the proposed field-size correction method agree with point measurements from an independent system to within a few tenth of a percent for output factor, head scatter, depth dose at depth, and out-of-field profile dose. Manufacturer recommendations for electrometer placement are insufficient and sometimes incorrect. Conclusions: RIB in scanning water tanks can have a non-negligible effect on dosimetric data.

60 APPLIED LIFE SCIENCES↗

Saltation threshold detection in a wind tunnel by the measurement of the net electrostatic charge

The Mars surface wind tunnel (MARSWIT) is an open circuit wind tunnel used for aeolian studies and is located inside a large vacuum chamber allowing testing at Martian surface atmospheric pressure. Since direct access is not available to the tunnel during operation at low pressure, a remote method of saltation detection is needed. The bed is observed by means of closed circuit video, but it is often difficult to determine the initiation of threshold. The measurement by means of an electrometer of the net electric charge produced by the saltating particles has provided a reliable means of saltation threshold detection. Saltating particles become charged several ways, both in wind tunnels and in a natural environment. The most significant of these methods are tribo-charging and contact charging, which always occur. Fracture charging may also occur under the high velocities associated with particle transport on Mars or under simulated Martian conditions. Detection in MARSWIT is achieved by allowing the saltating particles to impinge on a planar conducting surface normal to the flow that is connected to ground through a Keithly electrometer. The signal from the electrometer is connected to a strip chart recorder along with the analog signal from the pitot tube transducer that is used to determine the wind velocity in the tunnel. Thus, a record of wind velocity and the initiation of particle saltation is conveniently displayed together. While both positive and negative charges are produced during saltation, this method measures only the net charge; thus the charge may be either positive or negative depending upon the particles being tested, the size and size distribution of the test material, and the wind velocity. This has proven to be a very trustworthy and sensitive method of saltation threshold detection, being especially useful with the smaller sized particles which are the most difficult to observe visually.

Leach, Rodman N.↗

SU-E-T-156: Can Sr-90 Check Sources Replace Co-60 Measurements for Monitoring of Reference Chamber Stability?

Purpose: To determine the ultimate precision of a system for monitoring reference-class ion chamber stability using a commercial Sr-90 check source. Methods: A detailed investigation of a commercial Sr-90 check source (PTW48002) was carried out using a series of Farmer-type ionization chambers. Investigations included: positioning repeatability (angular variation as chamber is rotated in source, variation in ionization current with vertical alignment); chamber settling; short and long term repeatability Results: i) Measurement precision – the ionization current was typically 10 pA, and therefore a high-precision electrometer is required to prevent electrometer noise/resolution/leakage biaising the results. ii) Chamber settling - the chamber response stabilizes after approximately 10 minutes, which is longer than reported for linac beams and is likely due to the low doserate of the source.iii) The measured response depended at the 1 % level on the orientation of the chamber with respect to the source. However, consistent positioning resulted in repeatability at the 0.05 % level. Care was also required to ensure that the chamber was consistently positioned vertically with respect to the source. The sensitivity to vertical position was found to be > 1 % per mm.iv)With a uniform procedure the long-term (> 6 month) repeatability was found to be better than 0.1 % for multiple chamber types and potentially a precision of 0.05 % is achievable. Conclusion: A Sr-90 check source is easy to use and is a viable alternative to Co-60 for monitoring reference chamber stability.

60 APPLIED LIFE SCIENCES↗

Cryogenic CMOS circuits for single charge digital readout.

The readout of a solid state qubit often relies on single charge sensitive electrometry. However the combination of fast and accurate measurements is non trivial due to large RC time constants due to the electrometers resistance and shunt capacitance from wires between the cold stage and room temperature. Currently fast sensitive measurements are accomplished through rf reflectrometry. I will present an alternative single charge readout technique based on cryogenic CMOS circuits in hopes to improve speed, signal-to-noise, power consumption and simplicity in implementation. The readout circuit is based on a current comparator where changes in current from an electrometer will trigger a digital output. These circuits were fabricated using Sandia's 0.35 {micro}m CMOS foundry process. Initial measurements of comparators with an addition a current amplifier have displayed current sensitivities of < 1nA at 4.2K, switching speeds up to {approx}120ns, while consuming {approx}10 {micro}W. I will also discuss an investigation of noise characterization of our CMOS process in hopes to obtain a better understanding of the ultimate limit in signal to noise performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

Understanding Artifacts in Impedance Spectroscopy

Four-terminal measurements of impedance spectra have long been troubled by the presence of high frequency artifacts that typically indicate unphysically large inductive behavior. In this paper, we follow up on the observation of Fleig et al., that voltage and current are necessarily measured in different locations of the potentiostat circuit, and that, typically, the electrometer input is a virtual ground. In this case, the capacitance of coaxial cables that connect sample electrodes to the potentiostat provides a high frequency conduction path to ground, so that some of the current that passes through the sample bypasses the electrometer. In four-electrode measurements, this mechanism produces the observed inductive artifacts. We examine a variety of simulated samples, with calculations compared to measurements of relevant circuits, to quantitatively investigate the nature of the artifacts. Model results agree with measurements when the leakage capacitances are properly included in the circuit analyses. With understanding of the origin of the inductive artifacts, the four-electrode method can be effectively utilized, enabling a combination of two-, three- and four-electrode measurements to be used to best advantage. Finally, using this combination of electrode configurations, temperature dependent measurements of SrTiO 3 , Y 2 O 3 -stabilized ZrO 2 , and In 2 O 3 films deposited on YSZ substrates are presented.

36 MATERIALS SCIENCE↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Development of the cosmic ray techniques

It has been found that most advances of cosmic-ray physics have been directly related to the development of observational techniques. The history of observational techniques is discussed, taking into account ionization chambers, refinements applied to ionization chambers to make them suitable for an effective use in the study of cosmic radiation, the Wulf-type electrometer, the electrometer designed by Millikan and Neher, the Geiger-Mueller counter, the experiment of Bothe and Kolhoerster, the coincidence circuit, and a cosmic-ray 'telescope'. Attention is given to a magnetic lens for cosmic rays, a triangular arrangement of Geiger-Mueller counters used to demonstrate the production of a secondary radiation, a stereoscopic cloud-chamber photograph of showers, the cloud-chamber picture which provided the first evidence of the positive electron, and arrangements for studying photon components, mu-mesons, and air showers.

Rossi, B.↗

The electrodynamometric balance of the small wind tunnel of the French Service of Aeronautical Research

This investigation shows the attempt to improve the electrodynamomoter designed by Mr. Villey. The force to be measured acts on a flexible steel plate which is placed in front of a fixed plate. The deformation varies the original thickness of the layer of air between the two plates, thus causing a more rapid variation in the coefficient of electrostatic attraction of the two plates than in the capacity of the condenser formed by the dynamometer. The measurements are made by a differential method. The capacity of the test dynamometer is compared with that of a similar instrument of constant capacity, this comparison being made by means of an electrometer. Diagrams are shown of the dynamometer, the electrometer, and the electrical connections.

Rebuffet, P↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Proposed Modifications to Engineering Design Guidelines Related to Resistivity Measurements and Spacecraft Charging

A key parameter in modeling differential spacecraft charging is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across the spacecraft, as well as the time scale for charge transport and dissipation. Existing spacecraft charging guidelines recommend use of tests and imported resistivity data from handbooks that are based principally upon ASTM methods that are more applicable to classical ground conditions and designed for problems associated with power loss through the dielectric, than for how long charge can be stored on an insulator. These data have been found to underestimate charging effects by one to four orders of magnitude for spacecraft charging applications. A review is presented of methods to measure the resistive of highly insulating materials, including the electrometer-resistance method, the electrometer-constant voltage method, the voltage rate-of-change method and the charge storage method. This is based on joint experimental studies conducted at NASA Jet Propulsion Laboratory and Utah State University to investigate the charge storage method and its relation to spacecraft charging. The different methods are found to be appropriate for different resistivity ranges and for different charging circumstances. A simple physics-based model of these methods allows separation of the polarization current and dark current components from long duration measurements of resistivity over day- to month-long time scales. Model parameters are directly related to the magnitude of charge transfer and storage and the rate of charge transport. The model largely explains the observed differences in resistivity found using the different methods and provides a framework for recommendations for the appropriate test method for spacecraft materials with different resistivities and applications. The proposed changes to the existing engineering guidelines are intended to provide design engineers more appropriate methods for consideration and measurements of resistivity for many typical spacecraft charging scenarios.

Dennison, J. R.↗

Charge-coupled-device parallel-to-serial converter

A CCD parallel-to-serial converter comprising two successions of charge transfer stages, recurrently side-loaded with respective ones of parallelly supplied charge packets, then serially unloaded by time-interleaved respective shift register operations. The charge packets converted to time-division-multiplexed serial form are supplied to a shared electrometer, and the electrometer response is de-multiplexed. Preferably, shift register operations are carried forward concurrently at the same rate, but with the final charge transfer stages clocked in phases staggered in time.

Tower, John R.↗

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗