Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of Surface Texture on Pinhole Formation in SiO x -Based Passivated Contacts for High-Performance Silicon Solar Cells

High-efficiency silicon solar cells rely on some form of passivating contact structure to reduce recombination losses at the crystalline silicon surface and losses at the metal/Si contact interface. One such structure is polycrystalline silicon (poly-Si) on oxide, where heavily doped poly-Si is deposited on a SiO x layer grown directly on the crystalline silicon (c-Si) wafer. Depending on the thickness of the SiO x layer, the charge carriers can cross this layer by tunneling (<2 nm SiO x thickness) or by direct conduction through disruptions in the SiOx, often referred to as pinholes, in thicker SiO x layers (>2 nm). In this work, we study structures with tunneling- or pinhole-like SiO x contacts grown on pyramidally textured c-Si wafers and expose variations in the SiOx layer properties related to surface morphology using electron-beam-induced current (EBIC) imaging. Using EBIC, we identify and mark regions with potential pinholes in the SiO x layer. We further perform high-resolution transmission electron microscopy on the same areas, thus allowing us to directly correlate locally enhanced carrier collection with variations in the structure of the SiO x layer. Our results show that the pinholes in the SiO x layer preferentially form in different locations based on the annealing conditions used to form the device. With greater understanding of these processes and by controlling the surface texture geometry, there is potential to control the size and spatial distribution of oxide disruptions in silicon solar cells with poly-Si on oxide-type contacts; usually, this is a random phenomenon on polished or planar surfaces. Such control will enable us to consistently produce high-efficiency devices with low recombination currents and low junction resistances using this contact structure.

14 SOLAR ENERGY↗

New Convex Grating Types for Concentric Imaging Spectrometers

The properties of convex gratings fabricated by electron-beam lithography are investigated. Three grating types are shown. These gratings allow the optical designer to fully realize the considerable advantages of concentric spectrometer forms.

spectrometers concentric imaging electron beam↗

Imaging Secondary Electron Emission from a Single Atomic Layer

Graphene-based devices hold promise for a wide range of technological applications. Yet characterizing the structure and the electrical properties of a material that is only one atomic layer thick still poses technical challenges. Recent investigations indicate that secondary-electron electron-beam-induced current (SE-EBIC) imaging can reveal subtle details regarding electrical conductivity and electron transport with high spatial resolution. Here, it is shown that the SEEBIC imaging mode can be used to detect suspended single layers of graphene and distinguish between different numbers of layers. Pristine and contaminated areas of graphene are also compared to show that pristine graphene exhibits a substantially lower SE yield than contaminated regions. In conclusion, this SEEBIC imaging mode may provide valuable information for the engineering of surface coatings where SE yield is a priority.

36 MATERIALS SCIENCE↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Earth Observing System (EOS) synthetic aperture radar (SAR)

The evolution of the Spaceborne Imaging Radar (SIR) has led to a multipolarization, multifrequency SAR with variable imaging geometry which will be ready for flight on the Space Station Earth Observing System (EOS). Nominally, this SAR will be a three-frequency (L-, C-, and X-band) system with quad polarization available for the L and C bands. It will be capable of acquiring multiincidence-angle data using electronic beam steering, and other imaging geometries by mechanically pitching, yawing, and rolling the antenna. The capabilities of the EOS SAR, particularly acquisition of cross-polarized and high-incidence-angle data, depend on the altitude of the platform on which the SAR flies and improve significantly at lower altitudes. The EOS SAR will provide a unique new data set and will play a key role in understanding the earth's global processes, alone and synergistically with other EOS instruments.

Cimino, Jobea↗

Correlation of EBIC and SWBXT Imaged Defects and Epilayer Growth Pits in 6H-SiC Schottky Diodes

We show the first direct experimental correlation between the presence of closed core screw dislocations in 6H-SiC epilayers with recombination centers, as well as with some of the small growth pits on the epilayer surface in lightly-doped 6H-SiC Schottky diodes. At every Synchrotron White-Beam X-ray Topography (SWBXT)-identified closed core screw dislocation, an Electron Beam Induced Current (EBIC) image showed a dark spot indicating a recombination center, and Nomarski optical microscope and Atomic Force Microscope (AFM) images showed a corresponding small growth pit with a sharp apex on the surface of the epilayer.

Schnable, C. M.↗

The EOS SAR program

The goal of the Spaceborne Imaging Radar (SIR) program is to develop a multipolarization, multifrequency synthetic aperture radar (SAR) with variable imaging geometry which will be ready for flight on the Earth Observing System (EOS) in the mid 1990's. Nominally, this SAR will be a three frequency (L-, C- and X-band) system with quad-polarization available for the L- and C-bands and dual polarization for the X-band system. It will be capable of acquiring multiincidence angle data using electronic beam steering and other imaging geometries by mechanically pitching, yawing and rolling the antenna. The EOS SAR will play a key role along with the other EOS instruments in understanding the earth as a system.

Cimino, Jobea↗

The spaceborne imaging radar experiments

The Spaceborne Imaging Radar (SIR), a multifrequency multipolarization synthetic aperture radar (SAR) with variable image geometry, is being developed, as part of the Space Station's Earth Observing System (Eos), for the launching of the SIR-C and SIR-D planned for the early 1990's. This SAR will operate in L-band, C-band and X-band, with quadpolarization available for the L-band and C-band. Multiincidence data will be acquired using electronic beam steering and other imaging geometries by mechanically pitching, yawing, and rolling the antenna. The present SIR-C design includes a bandwidth of 20 MHz, to provide better resolution than that available on SIR-B with four looks, and a 10-MHz bandwidth for a low resolution mode which will increase the swath for a given available data rate.

Cimino, J. B.↗

Atomic‐Resolution Imaging of Halide Perovskites Using Electron Microscopy

Abstract Atomic‐resolution imaging of halide perovskites (HPs) using transmission electron microscopy (TEM) is challenging because of the sensitivity of their structures to the electron beam. In this article, recent achievements in this area are reviewed, covering both all‐inorganic and organic–inorganic hybrid HPs, with an emphasis on the specific imaging conditions that have proven to be effective in avoiding electron beam‐induced structural damage. The discussion focusses on the total electron dose that HPs can bear before being damaged and the effects of different imaging modes, accelerating voltages, and temperatures. The crucial role of a direct‐detection electron‐counting camera in reducing the required electron dose is outlined, which is indispensable for imaging extremely sensitive organic–inorganic hybrid perovskites. In addition to reviewing published works, the results of initial attempts to perform atomic‐resolution elemental mapping for an all‐inorganic HP and image a hybrid HP using scanning TEM are introduced. The preparation of a TEM specimen from macroscopic crystals or devices of HPs, which is very important for practical applications but has not yet received attention, is also discussed. This article aims to provide guidance on the acquisition of atomic‐resolution TEM images of HPs and inspire the development of more imaging technologies for sensitive materials.

Song, Kepeng↗

Highly efficient photoelectric effect in halide perovskites for regenerative electron sources

Electron sources are a critical component in a wide range of applications such as electron-beam accelerator facilities, photomultipliers, and image intensifiers for night vision. We report efficient, regenerative and low-cost electron sources based on solution-processed halide perovskites thin films when they are excited with light with energy equal to or above their bandgap. We measure a quantum efficiency up to 2.2% and a lifetime of more than 25 h. Importantly, even after degradation, the electron emission can be completely regenerated to its maximum efficiency by deposition of a monolayer of Cs. The electron emission from halide perovskites can be tuned over the visible and ultraviolet spectrum, and operates at vacuum levels with pressures at least two-orders higher than in state-of-the-art semiconductor electron sources.

36 MATERIALS SCIENCE↗

Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination

To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D-to-3D image translation of complex nanoporous volumes using generative networks

Image-based characterization offers a powerful approach to studying geological porous media at the nanoscale and images are critical to understanding reactive transport mechanisms in reservoirs relevant to energy and sustainability technologies such as carbon sequestration, subsurface hydrogen storage, and natural gas recovery. Nanoimaging presents a trade off, however, between higher-contrast sample-destructive and lower-contrast sample-preserving imaging modalities. Furthermore, high-contrast imaging modalities often acquire only 2D images, while 3D volumes are needed to characterize fully a source rock sample. In this work, we present deep learning image translation models to predict high-contrast focused ion beam-scanning electron microscopy (FIB-SEM) image volumes from transmission X-ray microscopy (TXM) images when only 2D paired training data is available. We introduce a regularization method for improving 3D volume generation from 2D-to-2D deep learning image models and apply this approach to translate 3D TXM volumes to FIB-SEM fidelity. We then segment a predicted FIB-SEM volume into a flow simulation domain and calculate the sample apparent permeability using a lattice Boltzmann method (LBM) technique. Results show that our image translation approach produces simulation domains suitable for flow visualization and allows for accurate characterization of petrophysical properties from non-destructive imaging data.

58 GEOSCIENCES↗

Comparison of PID Shunting in Polycrystalline and Single-Crystal Silicon Modules via Multi-Scale, Multi-Technique Characterization

We used the methods we reported last year to investigate potential-induced degradation (PID). We have now applied these methods to single-crystalline silicon modules that have degraded during field deployment, as well as in minimodules stressed in the laboratory. We will compare these results to the polycrystalline results presented last year. Small cores have been removed from the modules and subjected to analysis. We use a combination of photoluminescence and dark lock-in thermography imaging, laser marking, electron-beam induced current measurements, and subsequent focused ion-beam marking to allow analysis of individual defects via time-of-flight secondary-ion mass spectrometry (TOF-SIMS) to investigate the root-cause mechanism for PID shunting. We see a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiN/Si interface and is consistently observed at a concentration of 0.1%-1% in shunted areas. TOF-SIMS data taken on degraded and non-degraded single-crystalline sample areas show a similar trend as in the polycrystalline samples: more sodium is seen in the degraded areas.

14 SOLAR ENERGY↗

Nonuniform Charge Collection in SiOx-Based Passivated-Contact Silicon Solar Cells

In this contribution, we report on the charge-collection characteristics of silicon photovoltaic devices using passivated contacts based on the c-Si/SiO x /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiO x layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The apexes of the pyramids exhibit reduced EBIC signal whereas the valleys between adjacent pyramids show the strongest collection. Our results indicate that charge collection in c-Si/SiO x /poly-Si structures can be influenced by both the properties of the SiO x layer and surface texture.

14 SOLAR ENERGY↗

Revealing the Nano-Scale Structure and Properties of Pinholes in SiOx Layers for POLO Contacts

In this contribution, we report on the charge collection characteristics of silicon photovoltaic devices with passivated contacts based on the c-Si/SiOx /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiOx layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The locations where we observe preferential collection of excess carriers is very sensitive to the processing conditions used to grow and breakup the SiOx passivation layer. In some cases the apexes of the pyramids exhibit reduced EBIC signal as the valleys between adjacent pyramids show the strongest collection. Other conditions yield enhanced charge collection at well defined spots on pyramid faces with no observable collection in the valleys.

EBIC↗