Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

High-Resolution Imaging of Cellulose Organization in Cell Walls by Field Emission Scanning Electron Microscopy

Field emission scanning electron microscopy (FESEM) is a powerful tool for analyzing surface structures of biological and nonbiological samples. However, when it is used to study fine structures of nanometer-sized microfibrils of epidermal cell walls, one often encounters tremendous challenges to acquire clear and undistorted images because of two major issues: (1) Preparation of samples suitable for high resolution imaging; due to the delicateness of some plant materials, such as onion epidermal cell walls, many things can happen during sample processing, which subsequently result in damaged samples or introduce artifacts. (2) Difficulties to acquire clear images of samples which are electron-beam sensitive and prone to charging artifacts at magnifications over 100,000×. In this chapter we described detailed procedures for sample preparation and conditions for high-resolution FESEM imaging of onion epidermal cell walls. Lastly, the methods can be readily adapted for other wall materials.

59 BASIC BIOLOGICAL SCIENCES↗

Oxide Two‐Dimensional Electron Gas with High Mobility at Room‐Temperature

Abstract The prospect of 2‐dimensional electron gases (2DEGs) possessing high mobility at room temperature in wide‐bandgap perovskite stannates is enticing for oxide electronics, particularly to realize transparent and high‐electron mobility transistors. Nonetheless only a small number of studies to date report 2DEGs in BaSnO 3 ‐based heterostructures. Here, 2DEG formation at the LaScO 3 /BaSnO 3 (LSO/BSO) interface with a room‐temperature mobility of 60 cm 2 V −1 s −1 at a carrier concentration of 1.7 × 10 13 cm –2 is reported. This is an order of magnitude higher mobility at room temperature than achieved in SrTiO 3 ‐based 2DEGs. This is achieved by combining a thick BSO buffer layer with an ex situ high‐temperature treatment, which not only reduces the dislocation density but also produces a SnO 2 ‐terminated atomically flat surface, followed by the growth of an overlying BSO/LSO interface. Using weak beam dark‐field transmission electron microscopy imaging and in‐line electron holography technique, a reduction of the threading dislocation density is revealed, and direct evidence for the spatial confinement of a 2DEG at the BSO/LSO interface is provided. This work opens a new pathway to explore the exciting physics of stannate‐based 2DEGs at application‐relevant temperatures for oxide nanoelectronics.

2-dimensional electron gas↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Water content modulation enables selective ion transport in 2D MXene membranes

Separation membranes are critical for a range of processes, including but not limited to water desalination, chemical and fuel production, and recycling and recovery applications. Fundamentally, there are intrinsic trade-offs between permeability and selectivity. Local water organization and content can impact membrane structure (short- and long-range) in laminar transition metal carbide (MXene) membranes and impact selective ion permeation. Intercalation of chaotropic cesium (Cs + ) ions within the layers reduces the water content in the membrane and at the surface which cannot be found in the intercalation of other ions. Additionally, 3D imaging using focused ion beam scanning electron microscopy showed fewer defects in the Cs-MXene membrane, due to reduced local water content, leading to more efficient ion sieving. X-ray diffraction and density functional theory calculations on the nanochannel structure demonstrated that the chaotropic ion results in the smallest nanochannel size and induces a stronger resistance to water-induced nanochannel swelling. With a narrower nanochannel, the Cs-MXene membrane limits ion transport pathways, resulting in more selective transport of lithium over other metal cations, as evidenced in both experiment and molecular dynamics simulations. In conclusion, our findings highlight the potential for controlling the structural organization of 2D MXene membranes to enable on-demand transport of ions for diverse applications.

36 MATERIALS SCIENCE↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Visualizing defects and pore connectivity within metal–organic frameworks by X-ray transmission tomography

Metal–Organic Frameworks (MOFs) have the potential to change the landscape of molecular separations in chemical processes owing to their ability of selectively binding molecules. Their molecular sorting properties generally rely on the micro- and meso-pore structure, as well as on the presence of coordinatively unsaturated sites that interact with the different chemical species present in the feed. In this work, we show a first-of-its-kind tomographic imaging of the crystal morphology of a metal– organic framework by means of transmission X-ray microscopy (TXM), including a detailed data reconstruction and processing approach. Corroboration with Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) images shows the potential of this strategy for further (non-destructively) assessing the inner architecture of MOF crystals. By doing this, we have unraveled the presence of large voids in the internal structure of a MIL-47(V) crystal, which are typically thought of as rather homogeneous lattices. This challenges the established opinion that hydrothermal syntheses yield relatively defect-free material and sheds further light on the internal morphology of crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Correlative electron and ion beam analysis of the electrochemical performances of LiV 3 O 8 cathode films as a function of microstructures

Degradation mechanisms in LiV 3 O 8 cathode films (~500 nm) with different initial microstructures i.e., globular nanocrystals in amorphous matrix and needle-like nanocrystals, synthesized by annealing the cathodes at 150 °C and 300 °C for 6 h are studied by Transmission Electron Microscopy (TEM) and Auger Electron Spectroscopy (AES). In addition, a unique in-situ combination of TEM and Secondary Ion Mass Spectrometry (SIMS) imaging techniques, namely Parallel Ion and Electron beam Spectrometry (PIES) is carried out to measure the 3D distribution of V and Li with nanoscale resolution. These characterization studies focus on correlating the pre- and post-cycling microstructure to observed electrochemical performance. The LiV 3 O 8 cathode film with needle-like nanocrystals (300 °C) shows a higher initial capacity but it degrades rapidly compared to the film with globular nanocrystals embedded in amorphous matrix (150 °C). We observed that LiV 3 O 8 films with needle-like nanocrystals are more susceptible to cathode decohesion and vanadium dissolution than the films with globular nanocrystals embedded in amorphous matrix, explaining the differences in their electrochemical performance. The findings from this study have relevance to the development of thin film electrode microstructures for high capacity and cyclic stability.

25 ENERGY STORAGE↗

Electron-Beam-Related Studies of Halide Perovskites: Challenges and Opportunities

Electron beam microscopy and related characterization techniques play an important role in revealing the microstructural, morphological, physical, and chemical information of halide perovskites and their impact on associated optoelectronic devices. However, electron beam irradiation usually causes damage to these beam-sensitive materials, negatively impacting their device performance, and complicating this interpretation. Here, the electron microscopy and spectroscopy techniques are reviewed that are crucial for the understanding of the crystallization and microstructure of halide perovskites. In addition, special attention is paid to assessing and mitigating the electron beam-induced damage caused by these techniques. Since the halide perovskites are fragile, a protocol involving delicate control of both electron beam dose and dose rate, coupled with careful data analysis, is key to enable the acquisition of reliable structural and compositional information such as atomic-resolution images, chemical elemental mapping and electron diffraction patterns. Limiting the electron beam dose is critical parameter enabling the characterization of various halide perovskites. Novel methods to unveil the mechanisms of device operation, including charge carrier generation, diffusion, and extraction are presented in scanning electron microscopy studies combined with electron-beam-induced current and cathodoluminescence mapping. Future opportunities for electron-beam-related characterizations of halide perovskites are also discussed.

36 MATERIALS SCIENCE↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

From ground to excited electronic state dynamics of electron and ion irradiated graphene nanomaterials

Microscopes utilizing convergent electron and ion beams are emerging as powerful tools for both imaging and manipulating two-dimensional materials with atomic resolution, allowing the ultimate limits of nanofabrication to be realized. In this chapter, we detail the use of time-dependent electronic structure theory to determine the excited state properties and reactivity of functionalized graphene nanostructures. A time-dependent density functional theory treatment of electronic excitations of materials is presented, with specific emphasis on predicting the position-dependent electronic response of two-dimensional nanomaterials to electron beams. The method is demonstrated in a study highlighting the important role that electronic excitation can play in opening reaction pathways relevant to atomically precise defect manipulation in graphene. Finally, we provide some perspective on future development directions for methods of simulating nonequilibrium electronic and vibrational dynamics induced by electron/ion beams.

Lingerfelt, David↗

Optimizing Sub-Sampled STEM Imaging for Beam Sensitive Materials and Dynamic Processes

The goal of this research is to quantify how sub-sampling and inpainting (broadly classified as methods in Artificial Intelligence) can be used to obtain the highest resolution images under any experimental conditions, and to use this to reproducibly control dynamic in-situ processes in gases and liquids on the nanoscale. As atomic diffusion under non-extreme conditions is typically in the sub-ms time domain, the ability to use this sub-sampling approach to reduce the effect of the electron beam and to speed-up the imaging process represents the optimum combination of spatial and temporal resolution achievable in a conventional microscope. This LDRD funding demonstrated the feasibility of imaging dynamics in complex energy systems using this methodology by establishing the optimum experimental sampling conditions (optimizing the number of pixels, speed, contrast and resolution) for each experiment. For in-situ liquid cell experiments this analysis shows that simply by distributing the same dose and dose rate maximally in space and time, the kinetics for radiolysis products can be modified significantly. The final stage of this work, i.e. the experimental demonstration of its use for nucleation and growth, was severely curtailed by issues with COVID19. However, all the experiments are designed and currently underway, with the goal to complete the final demonstration and publication as soon as safety concerns for laboratory access are met.

36 MATERIALS SCIENCE↗