Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Energy Codes at a Glance

Feeling dim from energy code confusion? Read on to give your inspections a charge. The U.S. Department of Energy’s Building Energy Codes Program addresses hundreds of inquiries from the energy codes community every year. This article offers clarification for topics of confusion submitted to BECP Technical Support of interest to electrical inspectors, focusing on the residential and commercial energy code requirements based on the most recently published 2006 International Energy Conservation Code® and ANSI/ASHRAE/IESNA1 Standard 90.1-2004.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 IECC Climate Zones

County mapping of the 2012 climate zones from the International Energy Conservation Code. Each county in the CONUS is assigned a temperature and moisture regime. This dataset contains the raw data, the mapped data in various formats, and plots of the output.

2012↗

A New State of the Art: Zero Energy Modular Multifamily Construction

In 2020, the U.S. Department of Energy's Building Technologies Office (BTO) launched the Advanced Building Construction (ABC) Initiative. This initiative aimed to integrate energy efficiency into high-production construction practices. One focus area of the initiative is off-site construction, an approach that may achieve scalable, efficient, and high-performing construction buildings through process standardization. This report presents the findings and recommendations from our ABC Initiative project: A New State of the Art: Zero-Energy Modular Multifamily Construction System. The objectives of the BTO-funded project are to: 1) Achieve energy performance 50% better than the 2018 International Energy Conservation Code (IECC). 2) Achieve this level of energy performance at no additional cost VEIC worked with Louisiana State University (LSU), National Renewal Energy Lab (NREL), [the project team], and industry partners at the Mod Coach, KBS, and Solar Home Factory to identify and analyze multifamily business designs and modular construction practices. These designs and processes hold the promise of achieving the goals set out by the DOE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Use Savings for a Typical New Residential Dwelling Unit Based on the 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) require a substantial improvement in energy efficiency compared to the 2006 IECC. This report averages the energy use savings for a typical new residential dwelling unit based on the 2009 and 2012 IECC compared to the 2006 IECC. Results are reported by the eight climate zones in the IECC and for the national average.

Lucas, Robert G.↗

Understanding the U.S. Commercial Building Stock: Building Envelope and HVAC Systems Characteristics Using 2012 CBECS Data Analysis

The U.S. Department of Energy (DOE) and its national labs developed a series of commercial reference building models in 2007. Over the past decade, the Pacific Northwest National Laboratory, in support of DOE’s Building Energy Codes Program, expanded these prototype building models to comply with multiple editions of national model codes and standards, including both ASHRAE Standard 90.1 and International Energy Conservation Code. The prototype building models established a credible foundation to develop new requirements in building codes and standards, track progress of codes and standards, and evaluate the energy saving potential of new technologies or systems in the commercial building sector. The 2003 Commercial Building Energy Consumption Survey (CBECS) was the primary data source used to develop the original models. Given the recent release of 2012 CBECS data, this paper characterizes the most representative design choices for building envelope and HVAC systems in recently-constructed commercial buildings. The results from this analysis provide actionable insight for future commercial building research in reflection of recent construction practices.

energy efficiency, building energy codes, CBECS, b↗

The Marriage of Residential Energy Codes and Rating Systems: Conflict Resolution or Just Conflict?

After three decades of coexistence at a distance, model residential energy codes and residential energy rating systems have come together in the 2015 International Energy Conservation Code. At the October, 2013, International Code Council’s Public Comment Hearing, a new compliance path based on an Energy Rating Index was added to the IECC. Although not specifically named in the code, RESNET’s HERS rating system is the likely candidate Index for most jurisdictions. While HERS has been a mainstay in various beyond-code programs for many years, its direct incorporation into the most popular model energy code raises questions about the equivalence of a HERS-based compliance path and the traditional IECC performance compliance path, especially because the two approaches use different efficiency metrics, are governed by different simulation rules, and have different scopes with regard to energy impacting house features. A detailed simulation analysis of more than 15,000 house configurations reveals a very large range of HERS Index values that achieve equivalence with the IECC’s performance path. This paper summarizes the results of that analysis and evaluates those results against the specific Energy Rating Index values required by the 2015 IECC. Based on the home characteristics most likely to result in disparities between HERS-based compliance and performance path compliance, potential impacts on the compliance process, state and local adoption of the new code, energy efficiency in the next generation of homes subject to this new code, and future evolution of model code formats are discussed.

Residential, Energy, Rating systems, HERS, 2015 IE↗

National Cost-Effectiveness of the Residential Provisions of the 2024 IECC

This analysis focuses on single-family and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). The IECC is developed by the International Code Council (ICC) on a 3-year cycle through a public development and consensus process. While proponents of code changes often include the energy and cost-effectiveness criteria for their respective code change, the IECC process does not include an energy or cost-effectiveness analysis of the entire edition of the code. PNNL evaluated the cost effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2024 edition of the IECC, hereafter referred as the 2024 IECC, compared to those in the prior edition, the 2021 IECC. The simulated performance path and the Energy Rating Index (ERI) path (introduced in the 2015 IECC) are not considered in this analysis due to the wide variation in building construction characteristics that are allowed.

2024 IECC↗

Nevada Compliance Implementation and Evaluation (CIE) Guide

This guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

Commercial buildings, residential buildings. code ↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program. A 2016 study looked more broadly at overall code impacts and this report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced emissions at the state level and at aggregated levels. In 2021, DOE conducted an interim and limited update to its 2016 study to evaluate potential building code updates using the 2016 methodology. That interim update includes estimated savings resulting from updates to the model energy codes, including the ANSI/ASHRAE/IES Standard 90.1-2016 (ASHRAE 90.1-2016) and 2019 editions, as well as the 2018 and 2021 International Energy Conservation Code (IECC). In 2023, DOE developed a fully updated report that includes code updates (ASHRAE 90.1-2019 and 2021 IECC), as well as additional enhancements and updates, including updated energy prices, annual floorspace additions, state code adoption dates, and emission factors, among others. This current version is another fully updated report that includes code updates (ASHRAE 90.1-2022 and 2024 IECC), as well as additional enhancements and updates, including updated energy prices, state code adoption dates, emission factors, and renewable energy contribution among others. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when the new code is implemented and builders, architects, and engineers are required to comply with the new provisions. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. The contributions of all three phases are crucial to the overall impact of codes and are considered in this assessment. Figure ES.1 schematically describes the analysis framework. Energy savings are expressed in terms of energy use intensity (EUI) in the figure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Idaho Residential Energy Code Field Study

A research project in the state of Idaho identified opportunities to reduce homeowner energy costs in residential single-family new construction by increasing compliance with the current state energy code. The study was initiated in January 2018; data collection began in March 2018 and continued through June 2018. During this period, research teams visited 127 homes during various stages of construction, resulting in a collection of data based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes and indicates nearly $500,000 in potential annual savings to Idaho homeowners that could result from increased compliance with the Idaho Energy Conservation Code.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guide to Determining Climate Zone by County: Building America and IECC 2021 Updates

This report describes the climate zone designations used by the U.S. Department of Energy (DOE) Building America Program. The report aims to help residential building stakeholders identify the appropriate climate zone designation for each county in the United States, including Hawaii and Alaska. Identifying the correct climate zone is important for many activities including residential construction projects, code compliance, energy analysis and modeling, and other analytical activities where climate zones impact the energy and moisture performance of residential buildings. This report supersedes the previous Building America publication: Guide to Determining Climate Regions by County, published in 2010. This report reflects climate designations used by the International Code Council (ICC) in the 2021 versions of the International Energy Conservation Code (IECC), the International Residential Code (IRC), and other codes produced by ICC. The information provided here and associated data should be used for the most up-to-date information regarding climate zone designations in the United States.

2021 IECC↗

National Energy and Cost Savings for New Single- and Multifamily Homes: A Comparison of the 2006, 2009, and 2012 Editions of the IECC

The 2009 and 2012 International Energy Conservation Code (IECC) yield positive benefits for U.S. homeowners and significant energy savings for the nation. Moving from a baseline of the 2006 IECC to the 2009 IECC reduces average annual energy costs by 10.8%, while moving from the same baseline to the 2012 IECC reduces them by 32.1%. These reductions amount to annual energy cost savings of $\$$168 and $\$$497, respectively. The 2012 IECC saves $\$$329 in energy costs compared to the 2009 IECC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects from the Reduction of Air Leakage on Energy and Durability

Buildings are responsible for approximately 40% of the energy used in the US. Codes have been increasing building envelope requirements, and in particular those related to improving airtightness, in order to reduce energy consumption. The main goal of this research was to evaluate the effects from reductions in air leakage on energy loads and material durability. To this end, we focused on the airtightness and thermal resistance criteria set by the 2012 International Energy Conservation Code (IECC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Evaluating Cost-effectiveness of Commercial Energy Code Changes

This document lays out the U.S. Department of Energy’s (DOE’s) method for evaluating the cost-effectiveness of energy code proposals and editions. The evaluation is applied to provisions or editions of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 90.1 and the International Energy Conservation Code (IECC). The method follows standard life-cycle cost (LCC) economic analysis procedures. Cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes, 2) evaluating the incremental and replacement costs related to the changes, and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Iowa Compliance Implementation and Evaluation Guide

This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

Cole, Pamala C.↗