Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Health and Energy Efficiency in Multi-Family Buildings

The intersection between health and the built environment has long been known. Since the 18 th century, public health officials have been targeting building issues, such as crowding, poor sanitation, and inadequate ventilation in efforts to reduce infectious diseases and fire hazards. More recently, federal agencies, such as the U.S. Environmental Protection Agency (EPA), the Centers for Disease Control and Prevention, HUD, and the DOE have been working to reduce or eliminate indoor building factors that are known to have adverse health impacts on Americans, including reducing lead in housing and indoor air pollution that causes respiratory disease, and ensuring access to adequate heating, cooling, and moisture control. PNNL, in support of FEMP’s HBI, undertook a review of literature and existing best practices to identify current activities and research on the intersection between traditional energy-efficiency measures and occupant health within multi-family buildings. While the HBI methodology has focused on traditional office building spaces, it is now expanding into additional building use types. This overview explores some of the most impactful resources to help property owners and managers understand more about multi-family residential buildings that are both healthy and energy efficient. The federal government provides direct oversight and operation across several types of multi-family residential housing, including dormitories, barracks, and senior community living centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability

In fall 2019, the National Association of Regulatory Utility Commissioners (NARUC) and the National Association of State Energy Officials (NASEO) initiated a joint Microgrids State Working Group (MSWG), funded by the U.S. Department of Energy (DOE) Office of Electricity (OE). The MSWG aims to bring together NARUC and NASEO members to explore the capabilities, costs, and benefits of microgrids; discuss barriers to microgrid development; and develop strategies to plan, finance, and deploy microgrids to improve resilience. This report, Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability, focuses specifically on how clean energy microgrids can achieve both resilience and clean energy benefits. The paper provides an overview of the challenges faced by clean energy microgrids, outlines benefits that clean energy microgrids can provide, and details economic and cost considerations for the development of clean energy microgrid projects. Outlined in the paper are the necessary technological components of a clean energy microgrid, including generation, storage, energy efficiency measures, and smart controls. Current technologies are highlighted, along with potential configurations of clean technologies that are approaching cost competitiveness with commercially available options. The paper concludes with both policy and regulatory considerations for State Energy Offices and Public Utility Commissions to enhance the development and deployment of clean energy microgrids. Although it touches on the clean energy microgrids’ role in integrating distributed energy resources (DERs) into the larger grid, this is not the focus of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal strategies for a cost-effective and reliable 100% renewable electric grid

This paper explores cost-optimal pathways to 100% renewable power systems for the U.S. building stock. We show that long-duration misalignments of supply and demand, spanning from multi-day to seasonal timescales, present a dominant challenge that must be addressed to meet real-time 100% renewable targets. While long-duration misalignments can be addressed through energy storage, we show that alternative and readily available solutions that are more cost-effective should be considered first. Through a techno-economic analysis, we identify cost-optimal, region-dependent, supply-side, and demand-side strategies that reduce, and in some U.S. regions eliminate, the otherwise substantial capacities and associated costs of long-duration energy storage. Investigated supply-side strategies include optimal mixes of renewable portfolios and oversized generation capacities. Considered demand-side strategies include building load flexibility and building energy efficiency investments. Our results reveal that building energy efficiency measures can reduce long-duration storage requirements at minimum total investment costs. In addition, oversizing and diversifying renewable generation can play a critical role in reducing storage requirements, remaining cost effective even when accounting for curtailed generation. We identify regionally dependent storage cost targets and show that for emerging long-duration energy storage innovations to achieve broad adoption, their costs will need to compete with the decreasing cost of renewables. The findings of this research are particularly important given that most long-duration storage technologies are currently either uneconomical, geologically constrained, or still underdeveloped.

100% renewable↗

ResStock 2024.2 Dataset [Slides]

In the ResStock 2024.2 dataset, ResStock runs are used to create "what-if" scenarios including energy efficiency measures such as heat pumps, envelope improvements, and electrification of appliances. This dataset release includes 15 measure packages across two weather years and incorporates ResStock improvements in variable speed heat pump modeling, geothermal heat pump modeling, and housing characteristic data updates from RECS 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EnergyPlus-MCP: A model-context-protocol server for ai-driven building energy modeling

Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.

AI↗

The Yucatan Peninsula Energy Assessment: Pathways for a Clean and Sustainable Power System

This report begins with an overview of the status of the power sector in Mexico's Yucatán peninsula, including key challenges, followed by policy and program solutions that pave the way for a cleaner, more sustainable power sector in the Yucatan. This work is intended to provide information to the states of the Yucatán peninsula - Yucatán, Campeche, and Quintana Roo - for prioritization and future technical assistance from the 21st Century Power Partnership (21CPP) program, in Mexico including data gathering, capacity building, modelling and analysis, program and policy setting to help the states and the region overall best utilize its resources to meet its electricity needs while implementing energy efficiency measures towards a more sustainable, clean, reliable system with lower prices. This report is also available in Spanish: https://www.nrel.gov/docs/fy21osti/81142.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Combined Thermal-Water Microgrid Model

SAND2022-3874 O The Combined Thermal-Water Microgrid Model is a set of three models combined with controls algorithms for a Water Thermal Storage (WTS), Ground Source Heat Pump (GSHP), and Thermal Bridge Loop (TBL) that serves a residential neighborhood. The model allows a parametric investigation of volume of water storage versus number of ground heat exchanger bore-holes versus seasonal energy efficiency measures. The code is being released as open source so that the entire study can be replicated per an open access journal publication. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Villa, Daniel↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

Building Analytics Tool Deployment at Scale: Benefits, Costs, and Deployment Practices

Buildings are becoming more data-rich. Building analytics tools, including energy information systems (EIS) and fault detection and diagnostic (FDD) tools, have emerged to enable building operators to translate large amounts of time-series data into actionable findings to achieve energy and non-energy benefits. To expedite data analytics adoption and facilitate technology innovation, building owners, technology developers, and researchers need reliable cost–benefit data and evidence-based guidance on deployment practices. This paper fulfills these needs with the energy use and survey data from a wide-ranging research and industry partnership program that covers thousands of buildings installed with analytics tools. The paper indicates that after two years of implementation, organizations using FDD tools and EIS tools achieved 9% and 3% median annual energy savings, respectively. The median base cost and annual recurring cost for FDD are USD 0.65 per square meter (m2) (USD 0.06 per square foot [ft2]) and USD 0.22 per m2 (USD 0.02 per ft2), and are USD 0.11 per m2 (USD 0.01 per ft2) and USD 0.11 per m2 (USD 0.01 per ft2) for EIS. The common metrics and analyses that are used in the tools to support the discovery of energy efficiency measures are summarized in detail. Two best practice examples identified to maximize the benefits of tool implementation are also presented. Opportunities to advance the state of technology include simplified data integration and management, and more efficient processes for acting on analytics outputs. Compared with previous efforts in the literature, the findings presented in this paper demonstrate the effectiveness of building analytics tools with the largest known dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Level Model Articulation with BuildingSync and OpenStudio

The use of the BuildingSync schema for describing the contents of buildings is becoming more common with its recent integration into the Audit Template tool as well as ASHRAE’s Building Energy Quotient (bEQ) web portal. Although BuildingSync was initially created to store and transfer data related to building energy audits (as defined by ASHRAE Standard 211), it has since been expanded to store the data needed to articulate fully defined physics-based building energy models. BuildingSync combined with abstracted high-level input methods defined in OpenStudio’s Standards project and the newly developed BuildingSync gem allows BuildingSync eXtensible Markup Language (XML) (Bray, Paoli, Sperberg-McQueen, Maler, Eve (Sun Microsystems, & Francois, 2008) document to be converted into OpenStudio models. Automatic generation of a building energy model from data collected during an audit 1) eliminates the need to separately generate an energy model, 2) improves consistency between model generation, and 3) simplifies evaluation of various energy efficiency measures. This manuscript will discuss this open-source project, including: development of the validation infrastructure necessary to provide formalized expectations of informational requirements for BuildingSync documents; development of the BuildingSync gem for translation of BuildingSync documents to OpenStudio models as well as example implementations; and finally, the manuscript will elaborate on the advantages and disadvantages of using high-level models generated from BuildingSync as surrogates to detailed models.

30 DIRECT ENERGY CONVERSION↗

BETTER Together

The Standard Energy Efficiency Data (SEED) and Building Efficiency Targeting Tool for Energy Retrofits (BETTER) platforms are both developed by the Department of Energy and work better together. SEED is a database to manage building characteristics and performance data from a variety of sources. BETTER provides simple energy efficiency measure analyses based on high level data about the building or portfolio of buildings. A demonstration of each platform and their integration will be provided. The inputs for BETTER are building type, floor area, location, utility data, and whether PV shall be included in the analysis. The BETTER analysis can be manually set up through the web application or data can be uploaded with a BuildingSync XML file either directly or through the API. SEED can be the source of this data and the data can be sent to BETTER through the SEED application after the BETTER API token has been entered. The benefit of utilizing SEED is that it has connections to many other sources of data such as ENERGY STAR Portfolio Manager, Audit Template, and Salesforce. Therefore, it is likely that a user of SEED will already have the required inputs for BETTER in SEED already and can create BETTER analyses across their whole portfolio in a couple mouse clicks. This is a major time savings and enables decision makers an easy path to identify buildings that should undergo more detailed audits or retrofit pathways.

ASHRAE↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Assessment of the Yucatan Peninsula: Pathways to a Clean and Sustainable Energy System; Evaluación Energética de la Península de Yucatán: Vías para un Sistema Energético Limpio y Sustentable

Quintana Roo - for prioritization and future technical assistance from the 21st Century Power Partnership (21CPP) program, in Mexico including data gathering, capacity building, modelling and analysis, program and policy setting to help the states and the region overall best utilize its resources to meet its electricity needs while implementing energy efficiency measures towards a more sustainable, clean, reliable system with lower prices.; Este trabajo tiene como objetivo brindar información a los estados de la península de Yucatán - Yucatán, Campeche y Quintana Roo - para priorizar y dar asistencia técnica futura del programa 21st Century Power Partnership (21CPP), en México, incluyendo recolección de datos, desarrollo de capacidades, modelación y análisis, y el establecimiento de programas y políticas para ayudar a los estados y la región en general a utilizar mejor sus recursos, para satisfacer sus necesidades de energía eléctrica, implementando también medidas de eficiencia energética para obtener un sistema más sustentable, limpio y confiable con precios más bajos. This report is also available in English: https://www.nrel.gov/docs/fy21osti/79680.pdf.

21CPP↗