Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pushing Green: Leveraging Home Energy Score to Promote Deep-Energy Retrofits in Portland, Oregon

In the United States, 39% of total energy is consumed by the building sector, 20% of which is attributed to residential buildings. Older homes, built before 1992 when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of residential building stock in the country and often have significant air leakage, inadequate insulation and inefficient heating & cooling systems. These older homes have long been the elephant in the room: how can programs effectively increase efficiency in all of the homes in need? Developed by DOE, the Home Energy Score was established to provide homeowners, buyers, and renters a comparable score measuring a home's energy use. Much like the MPG rating of automobiles, the Home Energy Score provides an overview of a residential building’s energy efficiency. In 2016, the City of Portland passed an ordinance requiring all residential properties to receive a Home Energy Score before being listed for sale, a mandate that was implemented January 1, 2018. Since 2018, more than 22,000 homes throughout the Portland Metro area have received Home Energy Scores (amounting to over 10% of Portland's single-family homes). This paper explores the sample of Home Energy Scores throughout Portland, including at the neighborhood level, identifies trends in efficiency measures, describes how the data has been used to date and proposes ways program administrators can use the Home Energy Score to increase the impact of energy efficiency programs on a city-scale.

Antonopoulos, Chrissi A.↗

Integrated Solutions for Optimized Performance (ISOP) Final Technical Report

The goal of this project was to demonstrate technical feasibility of an integrated approach for deep energy retrofits by packaging innovative technologies with smart communicating controls that represent the next generation of energy efficiency. The integrated solutions for optimized performance (ISOP) package integrates (i) advanced lighting and plug load controls; (ii) intelligent daylight harvesting through automated self-powered shades and window films; (iii) advanced HVAC controls sequences (ASHRAE Guideline (GDL) 36); and (iv) fault detection and diagnosis (FDD) and continuous commissioning (CCx) using advanced analytics. These technologies address energy use across multiple building end uses that represent more than 60% of the energy consumption in all commercial buildings. The project was structured to be implemented over three budget periods: Budget Period 1 scope included site selection, project design, site-specific customization of technology packages, procurement of technologies, initiation of installation of technologies, the development of a measurement and verification plan and collection of pre-retrofit data collection. The first year go/no-go decision was based on securing host sites representing 250,000 sq. ft. of occupied operational spaces, savings analysis, technology procurement and initiation of installation. Budget Period 2 planned to complete technology installations and initiate data collection of post-retrofit performance data. The second year go/no-go was to be the completion of technology installations and commissioning, metering and data collecting to support the requirements laid out in site specific M&V plans. Budget Period 3 planned to collect and analyze post-retrofit performance data and provide data and reporting to support energy efficiency rebate programs. After the team completed activities planned for Budget Period 1, the team reached a Go/No-Go Decision Point. At that point, TRC recommended that DOE discontinue the project without prejudice due to challenges with securing demonstration sites to meet the full 250,000 sf of occupied operational spaces and DOE concurred. In Budget Period 1, the TRC team developed criteria to recruit and evaluate potential demonstration host sites. TRC worked with Princeton University, the project demonstration partner, to identify buildings on their campus as potential candidates for the demonstration. Following the selection of demonstration sites, the TRC team customized energy technology packages according to the needs and characteristics of each site. TRC defined technology specifications, identified vendors, and conducted analysis to estimate energy and cost savings potential. The project team then developed schedules for technology procurement processes and scheduled for installation at all selected demonstration sites. The project team worked with Princeton University and DOE to develop an approach to verify energy savings achieved through measurement and verification (M&V) 2.0 methods. Princeton University initiated open bids to procure the necessary materials and installation contractors. Bid results came back higher than estimates due to a couple of factors – lack of familiarity of the bidders with the proposed technologies and lack of local trained installers to execute the installation of these new measures. Due to the higher bids, projects no longer met the internal cost-effectiveness criteria used by Princeton to proceed with procurement of the full suite of technologies as proposed in ISOP. Princeton had already procured parts of the ISOP package as part of a campus-wide initiative for FDD and lighting retrofits, but with the higher costs for other ISOP components, Princeton could no longer commit to the full ISOP package on the selected sites. Based on this, the team reached the Go/No-Go decision point, where they decided not to proceed with the project. Princeton is separately installing portions of the ISOP package where they individually meet Princeton’s payback criteria but on a different schedule than would have been needed for the DOE ISOP project. The team has learned several lessons from project progress in the first budget period. The team will utilize these lessons in future projects, as should any team which proceeds with a project around the ISOP technology. The first lesson is that more information about the proposed sites is required earlier in the process (perhaps even at the proposal stage) in order to have a successful demonstration. Technical details not evident earlier in the process (such as the TLED limitations for ALCS) can derail project execution. The second lesson is that pricing of emerging technologies is highly variable due to lack of familiarity of local installers and distributor with the proposed technologies as well as alternate bids using products they were more familiar with, but that cost more than the ones proposed by TRC. Finally, the last major lesson is that the host site’s internal project criteria is of critical importance. Based on these higher installed costs and lack of an informed installer base for the products proposed for this project, the project does not meet Princeton’s simple payback goals of five years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fermentation and purification processes for producing Glucaric Acid

Through DOE’s Bioenergy Technologies Office Industrial Seeding Program and the Energy Efficiency and Renewable Energy Small Business Voucher Program, Massachusetts-based Kalion received support to work with the ABPDU to reach full manufacturing-scale production of biobased glucaric acid. One of the “Top Value-Added Chemicals from Biomass” identified in a 2004 report, glucaric acid is most commonly found in detergents and can be a substitute for less environmentally friendly phosphates. Scaling up manufacturing processes is a common obstacle for small companies like Kalion. By working with the ABPDU, Kalion went from a 2-liter to a 300-liter run via fermentation and provided another point of validation to its investors.

09 BIOMASS FUELS↗

Valuing Residential Energy Efficiency: Analysis for a Prototypical Southeastern Utility [Slides]

The increasing amount of variable renewable energy resources and shifts towards more end-use and vehicle electrification suggests profound changes to power system planning and operation. Specifically, renewable energy is expected to shift net peak demand from late afternoon to early evening and end-use electrification may significantly increase winter peak demand. Residential energy efficiency is likely to align well with these shifts as it tends to produce savings in the early evening (e.g., from lighting measures) and coincident with heating loads (e.g., from envelope and space conditioning measures). Despite the opportunity to decrease system costs and emissions, residential energy efficiency is often limited by static valuation methods and its economic potential is considerably less than its technical potential. Using hourly residential energy efficiency characterizations, utility program cost data, and a capacity expansion model, we estimate the benefits of residential energy efficiency for a prototypical, summer-peaking utility in the Southeastern region. We first establish the cost-effective residential energy efficiency portfolio through “competition” with supply-side resources in a forward-looking capacity expansion model. Importantly, we then evaluate several scenarios intended to drive an increasing amount of cost-effective residential energy efficiency through measure cost reductions, increased customer adoption, policy goals (e.g., carbon price), and delivery of an integrated package of measures. The results quantify total system cost and emissions reductions, fossil-fuel plant retirements, and peak demand reductions. Results suggest the design and prioritization of policies and programs to access the untapped amount of cost-effective residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INTREPID program: technology and architecture for next-generation, energy-efficient, hyper-scale data centers [Invited]

The INTREPID program is developing power-efficient coherent optics for package-level integration with future switch integrated circuits as a path to realizing higher-radix switches for flatter networks. The link architecture is underpinned by coherent quadrature phase-shift keying (QPSK) polarization-multiplex transceivers at 200 Gb/s per λ <#comment/> , further enhanced with wavelength division multiplexing (WDM) to enable energy-efficient 800 or 1600 Gb/s inter-switch fiber connections. The technology is compatible with conventional three-level data center designs as well as a two-level data center design introduced here, which includes an added layer of passive, arrayed waveguide grating routers (AWGRs) or WDM circuit switches to further improve the cost, energy efficiency, and latency of the network.

Saleh, Adel A. M. (ORCID:0000000182451136)↗

Empirical Estimation of the Energy Impacts of Projects Installed through Residential Property Assessed Clean Energy Financing Programs in California

We examine the energy use impacts of energy efficiency and solar PV projects financed by residential property assessed clean energy (R-PACE) programs in California. We leverage household-level interval meter data to apply normalized metered energy consumption (NMEC) methods at significant scale—more than 25,000 electric meters and more than 15,000 gas meters. We develop a comparison group to account for non-project-related changes in usage. The projects include homes that replaced existing HVAC equipment with higher-efficiency units and homes that installed central heating or air conditioning equipment for the first time. We have limited information on pre-project household equipment stock so we develop a method to infer new installations. We find that projects that installed energy efficiency technologies reduce electricity consumption by approximately 3% and gas consumption by approximately 3.5% on average. When we remove homes that installed new cooling and heating equipment for the first time, savings rise to approximately 5% for electricity and approximately 6% for gas. Given the California climate and the results of an existing study of similar California projects, these results are in line with expectations. Solar PV projects produce electricity that offsets approximately 69% of household electricity consumption on average. We estimate that California R-PACE projects installed through the end of 2019 produce annual reductions in grid-tied electricity consumption of 506 GWh (equivalent to the electricity consumption of approximately 74,000 California households) and gas consumption reductions of 2 million therms (equivalent to the gas consumption of approximately 4700 California households) in a typical weather year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Program Innovation Cluster for Equity and Health in Grid-Interactive Efficient Buildings (Final Technical Report)

The EPIC Buildings program was created to target Central New York’s (CNY) Energy Program Innovation Cluster, focused on developing energy hardware innovations for next-generation grid-interactive efficient buildings (GEB). The goals of the program were to establish and grow a sustainable regional innovation cluster for GEB in CNY and support the ambitious transition to achieve net-zero emissions by 2050.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Income Energy Affordability Data (LEAD) Tool

The Low-income Energy Affordability Data (LEAD) tool was created to provide data, such as energy burden, to stakeholders to make data driven decisions. The LEAD Tool provides a starting point for local governments, NGOs, companies, etc. to find areas with higher energy burden and cost to inform decisions about funding distribution and program qualifications. This presentation was given to energy efficiency and conservation block grant program applicants to explain how this tool can help them develop their energy efficiency and conservation strategy.

ENERGY PLANNING, POLICY, AND ECONOMY↗

MEP Core Tools

This slide deck provides an update on the progress of the project titled "MEP Core Tools" funded by the Energy Efficient Mobility Systems program in the Vehicle Technologies Office at the Department of Energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

Inventory of Clean Energy Education and Workforce Programs in Connecticut's I-91 Corridor

This document reports on the findings of an inventory of the educational and workforce development resources in a four-county area on the I-91 corridor in Connecticut. The overarching goal of this exercise is to help the local workforce leaders in Bridgeport, Connecticut to optimize their training programs to support the county's clean energy transition. The inventory generally finds that Fairfield County, where Bridgeport is located, lacks adequate education and training programs compared to other surrounding counties with similar populations. More than half of Fairfield County's programs occur through high school or career technical education programs, suggesting that there are minimal opportunities for workers who are not currently high school students. Much of the existing focus within Fairfield County is on general construction or plumbing and electrical skills. There is room to expand by offering more programs focusing on energy efficiency and renewable energy skills. The document outlines some potential next steps and questions for consideration for the local workforce leaders in Bridgeport. Bridgeport is a city located within Fairfield County in southwestern Connecticut. It is the largest city in Connecticut with an estimated population of 150,000. Through the Department of Energy-funded Communities LEAP program, NREL conducted an analysis of existing education and workforce development (EWD) programs located in Fairfield County that align with (or could support) the worker pipeline for occupations related to building energy efficiency (EE), renewable energy (RE), and clean energy manufacturing. The analysis also looked at EWD offerings in other counties in Connecticut as a point of comparison.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Consumer Benefits of Clean Energy: Energy Efficiency

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief focuses on energy efficiency benefits, and builds on prior analysis from Berkeley Lab’s Cost of Saved Energy database. We show that energy efficiency remains a low-cost energy and capacity resource; the levelized cost of saving energy for the programs included in the analysis is $\$0.02$/kilowatt-hour and the cost of saving peak demand is less $\$120$/kilowatt. Understanding the impact of the program mix, portfolio size, and duration of implementation for customer-funded energy efficiency portfolios can guide regulatory oversight of these programs, help utilities better utilize energy efficiency as a resource, and inform building energy decarbonization policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Core Modeling & Decision Support Capabilities: FASTSim, RouteE, T3CO & OpenPATH

These are the slides on NREL's Core Modeling and Decision Support Capabilities project for presentation at the 2023 Annual Merit Review for the U.S. Department of Energy, Vehicle Technologies Office. The project is funded by the Energy-Efficient Mobility Systems program to support four core tools: the Future Automotive Systems Technology Simulator (FASTSim), the Route Energy Prediction Model (RouteE), the Transportation Technology Total Cost of Ownership (T3CO) tool, and the Open Platform for Agile Trip Heuristics (OpenPATH).

ADVANCED PROPULSION SYSTEMS↗

Energy Efficiency and Renewable Energy Resources for State and Local Leaders

The Weatherization and Intergovernmental Programs Office (WIP) is part of DOE’s Office of Energy Efficiency and Renewable Energy (EERE) and supports DOE’s mission to create greater energy affordability, security, and resilience. WIP’s mission is to enable strategic investments in energy efficiency and renewable energy technologies using innovative practices across the United States in partnership with a wide range of stakeholders, including state and local organizations and community-based nonprofits. WIP supports DOE’s strategic objective to lower energy bills while expanding cost-effective energy choices for all Americans through the Weatherization Assistance Program (WAP) and State Energy Program (SEP). This resource guide highlights resources and publications from the State and Local Solution Center website and across EERE programs.

cost-effective energy, energy efficiency, tools an↗