Search NASA⌕ Search

SEARCH · Search NASA

Results for “engineered sorbents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Water treatment based on atomically engineered materials: Atomic layer deposition and beyond

Global water stress and challenges for producing sufficient supplies of fit-for-purpose water are amplifying. Atomically engineered interfaces are emerging as a powerful tool in the fabrication of advanced water treatment materials. Atomic layer deposition (ALD) and recently developed related methods, such as sequential infiltration synthesis (SIS), offer a tremendously diverse library of chemistries for interface functionalization. Thickness, stoichiometry, and physicochemical properties can be manipulated with precision. We review their fundamental physical chemistry and processing factors. ALD/SIS engineering strategies, including direct deposition, growth with intermediate layers, and secondary treatment are presented with realization of efficient water treatment. We lay out a pathway to establishing an ALD/SIS-based universal functionalization platform for water treatment, including sensitization strategies, in situ regulation, secondary reactions, and simulation/machine learning. Furthermore, we also provide a perspective on ALD/SIS-based interface engineering via synergy with other widely used interface engineering techniques to develop facile, versatile, and energy-efficient strategies for tackling increasingly complex water challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prioritizing Off-Gas Metrics: A Guide for Comparable Off-Gas Capture Testing

The Material Recovery and Waste Form Development (MRWFD) off-gas team had a workshop, hosted by Idaho National Laboratory (INL), to align goals and expectations for off-gas research. The workshop included team members from four national laboratories. The workshop focused on defining distinct R&D phases with specific metrics, outlining standard test and measurement protocols for Iodine and Krypton/Xenon sorbents, brainstorming approaches to future disruptive technologies, and recognizing parameters with more inherent risk, requiring more rigorous evaluation. This report will serve as a guide for future off-gas work. Its purpose is to foster efficient collaboration across diverse research facilities and invite direct comparison of materials and results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Porous liquids: an integrated platform for gas storage and catalysis

Porous liquids (PLs) represent a new frontier in materials design, combining the unique features of fluidity in liquids and permanent porosity in solids. By engineering well-defined pores into liquids via designed structure modification techniques, the greatly improved free volume significantly enhances the gas transport and storage capability of PL sorbents. Triggered by the promising applications of PLs in gas separation, PLs are further explored in catalysis particularly to integrate the gas storage and catalytic transformation procedure. This emerging field has demonstrated promising progress to advance catalytic procedures using PLs as catalysts, with performance surpassing that of the pure liquid and porous host counterparts. In this perspective article, the recent discoveries and progress in the field of integrated gas storage and catalysis by leveraging the PL platforms will be summarized, particularly compared with the traditional homogeneous or heterogeneous catalytic procedures. The unique features of PLs endow them with combined merits from liquid and solid catalysts and beyond which will be illustrated first. This will be followed by the unique techniques being utilized to probe the porosity and active sites in PLs and the structural evolution during the catalytic procedures. The catalytic application of PLs will be divided by the reaction categories, including CO 2 -involving transformation, O 2 -involving reaction, H 2 S conversion, hydrogenation reaction, and non-gas involving cascade reactions. In each reaction type, the synthesis approaches and structure engineering techniques of PLs, structure characterization, catalytic performance evaluation, and reaction mechanism exploration will be discussed, highlighting the structure–performance relationship and the advancement benefiting from the unique features of PLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data‐Driven Analysis of Amine‐Based Sorbents for CO 2 Removal from the Atmosphere

Available data on amine-based sorbents used for the direct air capture (DAC) process were gathered and analyzed to identify the correlations between various aspects of these sorbents and the operating conditions they are used in. It is demonstrated that a moderately high temperature (∼ 50 °C) can help with higher CO 2 capture capacity. Furthermore, the effect of sorbent preparation method on its activity and stability was studied. Also, the influence of amine groups and support choice on amine efficiency and CO 2 capture capacity was discussed. The DAC process conditions proved to play a major role in determining the optimal sorbent. An outlook for characteristics to be sought for in future DAC sorbents for CO 2 removal is proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Sorption-Enhanced Haber–Bosch Process

The use of a liquid sorbent in a traditional Haber-Bosch process enables significant improvements in energy efficiency and potential cost savings for arguably the most important chemical process on the planet. The approach presented in this report employs an incompressible liquid sorbent that absorbs and releases ammonia (NH 3 ) under specific conditions. To achieve this, we investigate reactions of ammonia and pure phosphoric acid (H 3 PO 4 , PA), which rapidly neutralize to form an equilibrated solution of monoammonium phosphate (MAP) and diammonium phosphate (DAP) that functions as a reversible and regenerable sorbent. Through intimate contact of the gas-phase Haber-Bosch reaction mixture with this liquid absorbent, complete equilibrium uptake may be achieved in an appropriately sized separator, and facile separation occurs through the use of independent liquid and gas phases. Following depressurization and release of the ammonia product, only the incompressible fluid needs to be repressurized and returned to the reactor. This study documents proof-of-concept absorption and desorption experiments carried out in 75 mL batch reactors, predominantly charged with precise MAP and DAP mixtures that equilibrate at process-relevant temperatures and pressures. We then assemble the first thermodynamic relationships that underlie this advantaged separation strategy, validated by reactive force field (ReaxFF) interatomic potential simulations, and benchmarked with traditional separation routes via process modeling and technoeconomic analysis. The scale of energy consumption in the century-old Haber-Bosch process is massive, and the elegant liquid sorption approach reported here offers opportunities to enhance its energy efficiency for the next frontier of ammonia synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-economic and environmental life cycle assessment of next-generation fiber-encapsulated nanoscale hybrid materials for direct air carbon capture

A techno-economic and environmental life cycle assessment was conducted for manufacturing two novel types of solid sorbents used for direct air CO 2 capture (DAC). One type of solid sorbent comprised Polyacrylonitrile (PAN)/Organopolysilizane (OPSZ)/nanoscale organic hybrid materials (NOHM)(, and the other comprised polymers of intrinsic microporosity (PIM)/NOHM. These solid sorbents were assumed to be manufactured via an unconventional route: electrospinning as fibers. Economic analyses revealed that manufacturing costs for a 0.73 MT/year capacity plant was $\$$831 and $\$$1398/kg of electrospun fiber in the case ofPAN/OPSZ/NOHM and PIM/NOHM, respectively. The costs were higher for PIM/NOHM owing to high raw material prices (Spirobisindane and tetrafluoroterephthalonitrile), that are used only in manufacturing PIM. Scaling up the plant capacity from 0.73 to 30 MT/year plant decreased the manufacturing cost by nearly half from $\$$831 to $\$$379 in the case of PAN/OPSZ/NOHM, depicting the economies of scale of effect. An LCA of both types of solid sorbent was performed using OpenLCA software, the Ecoinvent v 3.5 database, and the TRACI LCI assessment method. The Global Warming Potential (GWP) ofPAN/OPSZ/NOHM and PIM/NOHM was observed to be 151 × 10 -3 and 166 × 10 -3 kg CO 2 per kg CO 2 captured in the DAC plant, respectively. In conclusion, these GWP values were nearly five times as high as those observed for other solid sorbents existing in the literature such as PEI on silica gel, carbonate on silica, and carbonate on activated carbon owing to large amounts of electricity used in electrospinning unit operation.

36 MATERIALS SCIENCE↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

Final Report: Process Intensification of Hydrogen Production through Sorption-Enhanced Gasification of Biomass

The University of Utah, in partnership with Idaho National Laboratory (INL), evaluated Sorption-Enhanced Gasification (SEG) as a transformative pathway for producing hydrogen with the potential for negative CO 2 emissions. SEG integrates gasification, water-gas shift, and in-situ carbon capture within a dual fluidized bed reactor to enable efficient clean hydrogen production. Key challenges related to biomass variability and process complexity were addressed through feedstock engineering, reaction optimization, and process validation. A co-pelletized biomass–limestone feedstock was developed to simplify feeding and introduction of makeup limestone. Kinetic and sorbent studies identified optimal operating conditions and confirmed the suitability of low-cost limestone, while catalysts were developed to reduce tar formation. Reactor modeling and techno-economic analysis indicated that SEG can achieve competitive hydrogen production costs, particularly when combined with carbon incentives, supporting its potential for scale-up and carbon-negative operation.

08 HYDROGEN↗

Integrated Direct Air Capture and H₂-Free CO₂ Valorization

This project advances fundamental understanding of a novel integrated direct air capture (DAC) and CO₂ conversion process that valorizes atmospheric CO₂ without external H₂. The research encompasses four critical components: (1) design of task-specific ionic liquids for efficient CO₂ capture under ambient conditions, (2) development of H₂-free tandem catalytic systems using ethane as a reductant, (3) advanced operando characterization to elucidate capture and conversion mechanisms, and (4) data science-driven predictive computation to accelerate material discovery. Over the project period, we developed five high-performance DAC sorbent systems—including CaO/superbase ionic liquid composites, Ni-MOF/Ionic Liquid (IL) hybrids, fluorinated covalent organic frameworks with ion-pair functional groups, defect-engineered UiO-66, and a validated kinetic model for humid-condition operation, achieving CO₂ capacities up to 1.86 mmol/g at 400 ppm with excellent cycling stability. For H₂-free conversion, we constructed atomically synergistic Zn–O–Cr binuclear catalytic sites that achieve 100% ethylene selectivity, ~9.6% ethane conversion, and 99% CO₂ utilization in equimolar co-conversion of ethane and CO₂. We further demonstrated downstream valorization pathways converting CO and C₂H₄ into polyketones and C₃ chemicals. These advances strengthen the scientific foundation for producing value-added materials from ambient CO₂.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗