Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation methodology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Trace explosives sampling for security applications (TESSA) study: Evaluation of procedures and methodology for contact sampling efficiency

We report the detection of trace amounts of explosive materials is critical to the security at mass transit centers (e.g., airports and railway stations). In a typical screening process, a trap is used to probe a surface of interest to collect and transfer particulate residue to a detector for analysis. The collection of residues from the surface being probed is widely viewed as the limiting step in this process. A multi-institutional study was performed to establish a methodology for the evaluation of sampling media collection efficiencies. Dry deposited residues of 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), C-4 (an RDX-based explosive), and pentaerythritol tetranitrate (PETN) were harvested from acrylonitrile butadiene styrene (ABS) plastic, ballistic nylon (NYL), and uncoated aluminum surfaces using muslin, Texwipe cotton, and stainless-steel mesh traps. Transfer and collection efficiencies of the sample media were calculated based on liquid chromatography-mass spectrometry analysis. Dry transfer efficiencies (DTE%) to all tested surfaces were greater than 75%, with transfer to ABS plastic being the lowest. Collection efficiency (CE%) varied significantly across the traps and the surfaces, yet some conclusions can be drawn; nylon had the lowest CE% for all cases (~10%), and the stainless steel mesh had the lowest CE% for the evaluated traps (~20%). Though the testing parameters have been standardized among the participants to establish a framework for an independent comparison of contact sampling media and surfaces, substantial variations in the DTE% and the CE% were observed, suggesting that other variables can affect contact sampling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging

Abstract Ambient Noise Imaging (ANI) of subsurface structures relies on seismic interferometry of diffuse seismic wavefields. However, the lack of effective methods to quantify and identify highly diffuse waves hampers applications of ANI, particularly in evaluating seismic attenuation and monitoring structural changes with high temporal resolution. Conventional ANI approaches require data normalization, which effectively suppresses the non‐diffuse component with large amplitude but also results in significant loss of amplitude and phase information in the continuous seismic records. In this study, we propose a frequency domain method to quantitatively evaluate the degree of diffuseness of seismic wavefields by analyzing their statistical characteristics of modal amplitudes for stationarity and randomness. Tests on synthetic waveform and field nodal records show that the proposed method can effectively distinguish between diffuse and non‐diffuse waveforms for either single‐ or three‐component data. As an application, we identify a 60‐s‐long diffuse coda of a local M 2.2 earthquake recorded by a dense nodal array on the San Jacinto Fault Zone, and successfully extract high‐quality dispersion curve andQ‐value without performing data normalization. These results are consistent with those obtained by conventional methods that assess the correlation between coherency and the Green's function, and by modeling ballistic waves generated by road traffic. Our proposed method can advance the imaging of subsurface velocity and attenuation structures as well as monitoring temporal changes for scientific studies and engineering applications.

Geochemistry & Geophysics↗

Quality Guidelines for Energy System Studies: Performing a Techno-Economic Analysis for Carbon Conversion Technologies (Final Report)

This document provides DOE-FECM specific guidance for conducting techno-economic analysis (TEA) on carbon conversion technologies using NETL's established TEA methodology. The intent is to provide guidance to develop a consistent methodology for evaluating carbon conversion technologies within the DOE-FECM portfolio. The document provides guidance on the analysis methodology, evaluation metrics including performance, cost, emissions, and market considerations, and ample references to guide the end user in the development of consistent TEA of carbon conversion technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hardware-in-the-Loop Test Bed and Test Methodology for Microgrid Controller Evaluation

Increasing penetration levels of distributed energy resources are making the deployment of microgrids more feasible. Controllers that operate such microgrids are key to realizing the objectives of the microgrid owner or operator and there is a need to evaluate microgrid controller performance prior to field deployment. This paper describes a controller hardware-in-the-loop and power hardware-in-the-loop microgrid controller test bed that was designed and constructed to evaluate the capabilities of a microgrid controller for a proposed campus microgrid. This paper also presents a test methodology to evaluate microgrid controller functionality, and it describes how the controller was assessed through the application of different test scenarios. Results from the testing are presented to provide insight into the capabilities of the test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Workflow for Characterizing Legacy Wells as Potential Leakage Pathways for Integration to NRAP-Open-IAM

Carbon capture and storage is a crucial component of climate change mitigation strategies, involving the capture of carbon dioxide (CO2) from point sources and its injection into permeable subsurface formation. Many suitable CO2 storage sites coincide with legacy wells since the conditions that kept hydrocarbons in-situ for thousands of years are also ideal for storage of carbon dioxide. To protect underground sources of drinking water (USDW) during greenhouse gas injection, the Environmental Protection Agency (EPA) mandates area of review evaluations. These evaluations ensure that drinking water sources would not be contaminated by injected fluids. They include identification of legacy wellbores, integrity assessments, and implementing any necessary corrective action. Previous assessment approaches of legacy wells include high-level scoring of regional data and well construction and abandonment evaluation. This work describes a novel methodology that evaluates well construction and abandonment, ranks them based on complexity, and performs a risk assessment with NRAP-Open-IAM. A workflow of the methodology is presented, highlighting its capabilities and limitations.

Wise, Jarrett↗

Performance Evaluation of Vertical Federated Machine Learning Against Adversarial Threats on Wide-Area Control System: Preprint

Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.

adversarial threats↗

Uncertainty in Thermal Modeling of Spent Nuclear Fuel Casks

Uncertainty is a key metric in computational modeling that must be evaluated for results to have wide ranging applicability. A well characterized uncertainty range is ideal with clear error bars on results that can be presented to stakeholders. In the field of spent fuel cask modeling, this ideal has been historically difficult to achieve in practice because of the computationally intensive nature of the models used and the difficulty assigning reasonable uncertainties to quantities in as-built systems. The work in this report has been conducted to evaluate the overall state of uncertainty and sensitivity in spent fuel cask models and develop methodologies for evaluating these uncertainties. These methodologies must be practical for engineering applications. They should not require excessive computational resources or calendar time to achieve results. In engineering, the model must be on a scale such that it can be changed and adapted throughout a project as new information is discovered and project goals evolve. This report covers three major modeling task areas that provide an overview of the types of sensitivity and uncertainty present in a spent fuel storage and transportation system. Section 3 discusses sensitivity and uncertainty analysis in the effective thermal conductivity model for the fuel region and applies these results to a single assembly model. Section 4 shows sensitivity analysis of a full cask model in the TN-32B and Section 5 demonstrates the overall uncertainty workflow using Coolant Boiling in Rod Arrays – Spent Fuel Storage and STAR-CCM+ developed from the sensitivity work in the preceding sections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ARDP Natrium Neutronic Methodology: Argonne Neutronic Assessment of ABR-1000

The Natrium Sodium-cooled Fast Reactor (SFR) concept developed by TerraPower, LLC was selected as one of the advanced reactor designs for demonstration under the Advanced Reactor Demonstration Program Natrium Demo project. In collaboration with TerraPower, the Argonne National Laboratory (ANL) team provide independent reviews of the neutronic methodology being used for the Natrium design. As part of this activity, both the TerraPower and ANL teams agreed to perform independent neutronics analyses of the ABR-1000 reactor problem as a demonstration on the usage of the neutronics methodologies. Comparison of the results from TerraPower and ANL would expose any methodological differences in the modeling approaches. This report describes and presents the Argonne analysis work on the ABR-1000, and will be provided to TerraPower, along with data files, to complete the comparison study. The comparison will cover the methodology to evaluate the reactivity coefficients for a safety analysis, the shutdown margin, and the reconstructed pin power distribution. The methods and models used to calculate the kinetic parameters and the reactivity coefficients (density, Doppler, axial/radial expansion, etc.) are described in detail with recommendations of specific method options and modelling techniques. The control system reactivity worth and the excess reactivity due to temperature defect are calculated for the shutdown margin analysis. The method to evaluate the excess reactivity is discussed in detail. The pin power reconstruction methodology used in SE2ANL, SE2RCT, and DASSH are discussed in this report. The pin power distribution evaluated by different methods are compared and discussed in the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Score-Based Physics-Informed Neural Networks for High-Dimensional Fokker–Planck Equations

The Fokker-Planck (FP) equation is a foundational partial differential equation (PDE) in stochastic processes involving Brownian motions. However, the curse of dimensionality (CoD) poses a formidable challenge when dealing with high-dimensional FP equations. Although Monte Carlo simulation and (vanilla) Physics-Informed Neural Networks (PINNs) have shown the potential to tackle CoD, both methods exhibit significant numerical errors in high dimensions when dealing with the probability density function (PDF) associated with Brownian motion. The point-wise PDF values tend to decrease exponentially as dimensionality increases, surpassing the precision of numerical simulations and resulting in substantial errors. In addition, due to its massive sampling, Monte Carlo fails to offer fast sampling. Modeling the logarithm likelihood (LL) via vanilla PINNs transforms the FP equation into a notoriously difficult Hamilton-Jacobi-Bellman (HJB) equation, which is impractical for PINN learning, whose error grows rapidly with dimension. To this end, we propose a novel approach utilizing a score-based solver to fit the score function in stochastic differential equations (SDEs). The score function, defined as the gradient of the LL, plays a fundamental role in inferring LL and PDF and enables fast SDE sampling, offering an effective means to overcome the CoD. Three fitting methods, Score Matching (SM), Sliced Score Matching (SSM), and Score-PINN, are introduced, each contributing unique advantages in computational complexity, accuracy, and generality. The proposed score-based SDE solver operates in two stages: first, employing score matching or Score-PINN to acquire the score function; and second, solving the LL via an ordinary differential equation (ODE) using the obtained score function. Comparative evaluations across these methods showcase varying trade-offs. The proposed methodology is evaluated across diverse SDEs, including anisotropic Ornstein-Uhlenbeck processes, geometric Brownian motion, and Brownian motion with varying eigenspace. We also test various distributions, including Gaussian, Log-normal, Laplace, and Cauchy distributions. The numerical results demonstrate the score-based SDE solver’s stability, speed, and performance across different experimental settings, solidifying its potential as a solution to CoD for high-dimensional FP equations.

97 MATHEMATICS AND COMPUTING↗

Development and Outcomes of Returning Polycyclic Aromatic Hydrocarbon Exposure Results in the Washington Heights, NYC Community

Report-back of research results (RBRR) is becoming standard practice for environmental health research studies. RBRR is thought to increase environmental health literacy (EHL), although standardized measurements are limited. For this study, we developed a report back document on exposure to air pollutants, Polycyclic Aromatic Hydrocarbons, during pregnancy through community engaged research and evaluated whether the report increased EHL. We used focus groups and surveys to gather feedback on the report document from an initial group of study participants (Group 1, n = 22) and then sent the revised report to a larger number of participants (Group 2, n = 168). We conducted focus groups among participants in Group 1 and discussed their suggested changes to the report and how those changes could be implemented. Participants in focus groups demonstrated multiple levels of EHL. While participant engagement critically informed report development, a survey comparing feedback from Group 1 (initial report) and Group 2 (revised report) did not show a significant difference in the ease of reading the report or knowledge gained about air pollutants. We acknowledge that our approach was limited by a lack of EHL tools that assess knowledge and behavior change, and a reliance on quantitative methodologies. Future approaches that merge qualitative and quantitative methodologies to evaluate RBRR and methodologies for assessing RBRR materials and subsequent changes in knowledge, attitudes, and behavior, may be necessary.

Children’s Environmental Health↗

A New Probability Table Methodology with Covariances on Probability Tables

Through this work, we test a new methodology of evaluating probability tables informed by a combination of physics models and experimental data. This methodology uses generalized least squares to produce a joint mean and covariance for average cross sections and probability tables. This methodology has been tested and validated using total Monte Carlo. Attempts were made to parameterize the probability table using a formulation provided in. Although the normal inverse Gaussian fit was successful for the total cross section probability distribution, the rational-function fit to the capture, inelastic, and fission cross sections was unsuccessful due to time constraints.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Resonance Fitting for Nuclear Data Evaluation

Global and national efforts to deliver high-quality nuclear data to users have a wide-ranging impact, affecting applications in national security, reactor operations, basic science, medicine, and more. Cross section evaluation is a major part of this effort, combining theory and experimentation to produce recommended values and uncertainties for reaction probabilities. Resonance region evaluation is a specialized type of nuclear data evaluation that can require significant manual effort and months of time from expert scientists. In this article, non-convex non-linear optimization methods are combined with concepts of inferential statistics to infer a resonance model from experimental data in an automated manner that is not dependent on prior evaluation(s). This methodology aims to enhance the workflow of a resonance evaluator by minimizing time, effort, and the potential for bias from prior assumptions, while enhancing reproducibility and documentation, thereby addressing well-known challenges in the field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A ranking methodology for the coupling of pressurized water nuclear reactors and molten salt thermal energy storage

Thermal energy storage (TES) systems are a proposed solution to electricity market demand fluctuations and can be coupled to nuclear power plants to enable load following. Here, this work focuses on developing a methodology for evaluating potential designs for integrating a TES system into an existing pressurized water nuclear power plant. The proposed ranking methodology allows a group of experts to postulate and weigh designs based on ranking criteria derived from literature. The methodology developed in this study can aid in the final selection of a TES design for an existing nuclear power plant. The same process could be used to analyze other TES and nuclear reactor designs. The determined optimum design from this methodology was to place the TES system after the steam generator and to utilize the steam generated from the nuclear power plant to heat a molten salt TES unit. Another conclusion of this research was that human bias is prevalent during design selection, and actions such as standardized ranking criteria and large groups of experts should be used to minimize this error.

25 ENERGY STORAGE↗

AviSense: A Real-time System for Detection, Classification, and Analysis of Aviation Signals

We present AviSense, an SDR-based real-time, versatile system for monitoring aviation bands. AviSense detects and characterizes signal activities to enable practical and effective anomaly detection. We identify and tackle the challenges posed by a diverse set of critical aviation bands and technologies. We evaluate our methodology with real-world aviation signal measurements and demonstrate that we can classify aviation signals as normal with 99% accuracy. We also provide an exhaustive evaluation of our anomalous signal detection capability and show that we can accurately classify anomalous signals with 99% accuracy, with few exceptions. We also demonstrate that AviSense can effectively distinguish between different types of anomalies. We build a prototype implementation of AviSense for distributed monitoring.

42 ENGINEERING↗

Consistent Evaluation of the Prompt-fission Neutron Spectrum and Multiplicity for n+ 235,238 U and n+ 239 Pu

This report was written to satisfy a FY20 NCSP milestone on 235,238 U and 239 Pu. The milestone requires to “finalize a report assessing our methodology to evaluate prompt-fission neutron spectrum (PFNS) and multiplicity consistently”. More specifically, we study whether the code CGMF can reproduce ENDF/B-VIII.0 evaluated PFNS and average prompt-fission neutron multiplicities, $\bar{v}$, for 235,238 U and 239 Pu using one joint parameter set per isotope. If CGMF is shown to be able to reasonably reproduce ENDF/B-VIII.0 within its model-parameter space, this code could be used for future consistent evaluations of PFNS and $\bar{v}$. To answer this question, we explore here the parameter space of CGMF and its impact on calculated values and whether they are close to evaluated and experimental data. We also list experimental data that would enter a future evaluation and statistics method that could be used to obtain evaluated data and covariances. We conclude that values of $\bar{v}$ calculated by CGMF are reasonably close to ENDF/B-VIII.0 data, while more work on modeling the PFNS is needed (parameter optimization and model improvements) to reliably use it for evaluations.

07 ISOTOPE AND RADIATION SOURCES↗

Design Guidelines for Predicting Stress in Cemented Doublets Undergoing Temperature Change, Part 2

This work builds on prior work that developed a methodology for evaluating thermal stress in cemented doublets. The prior studies were limited by a paucity of actual test data, particularly from thermally tested cemented doublets. This follow-on study uses the existing methodology to estimate stresses in cemented doublets that have been tested for a temperature range from –40°C to 85°C and establishes safe stress levels using actual data. We also discuss limitations and concerns that we need to address to improve our understanding of cemented doublet failure.

36 MATERIALS SCIENCE↗